YWYixian Wang

Yixian Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yixian Wang has a total of 101 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Teaching the Concepts of Donnan Potential and Liquid-Junction Potential by Evaluating Homemade pH and Ion-Sensitive Probes Constructed Using Commercial Ion-Exchange Membranes and Reference Electrodes

    by William Gaieck, Anni Zhang, Ashley C. Sabatose, Madison T. Ngo, Gaurav Jha, Eric Schwartz, William White, Simon Luo, Peter McPartlan, Leanna Schulte, et al.

    Transport of ions across membranes or separators can result in electric potential differences that are sensed in most electrochemical experiments and impact the interpretation of the experimental results. To assist in comprehending the underlying causes and expected values of these electric potential differences, we designed, implemented, and evaluated hands-on laboratory experiments that were performed by undergraduate and graduate students in electroanalytical chemistry courses. The experiments require that students construct a simple two-compartment electrochemical cell using plastic cuvettes, a polymeric ion-exchange membrane, two reference electrodes placed in aqueous electrolytes that wet each side of the membrane, and a voltmeter or a potentiostat to measure the open-circuit potential between the electrodes. Open-circuit potentials measured between commercially available Ag/AgCl reference electrodes report on total Donnan and liquid-junction potentials. These electric potential differences are dictated by the composition of ions in each liquid electrolyte through interactions with the ion-exchange membrane and porous frits at the tip of each reference electrode. When reference electrodes consist of wires immersed directly in the liquid electrolytes, measured open-circuit potentials include contributions from Nernst potentials, which arise from electric double layer charging at each electrode interface driven by chemical potentials of redox-active species in the liquid electrolytes. While these experiments are suitable for most upper-level undergraduate students in STEM, the concepts of Donnan and liquid-junction electric potential differences and chemical potentials are advanced enough to educate graduate students and senior researchers alike. Student feedback obtained using surveys administered before and after the laboratory experiments provides additional guidance to instructors who plan to implement these experiments.

  • Open Access

    Spatially Resolved Biosensing of Localized Dopamine Release via Its Electropolymerization Using Plasmonic Electrochemical Microscopy

    by Christian Martinez, Samuel Groysman, Madison Ngo, Yixian Wang

    The precise spatiotemporal monitoring of dopamine is critical for understanding neurotransmission and neurodegenerative pathologies. While traditional electrochemical methods offer excellent temporal resolution, they lack the spatial resolution required to map network-wide dynamic events. To address this, we adapted a wide-field plasmonic electrochemical microscopy (PEM) platform to spatially image localized electrochemical reactions. Specifically, we leveraged the anodic electropolymerization of dopamine into a surface-confined polydopamine nanofilm to enable label-free, pixel-level optical quantification. Bulk solution testing demonstrated highly uniform sensor sensitivity, yielding an estimated single-pixel limit of detection of 14 pM. Furthermore, utilizing a custom injection system, we successfully imaged the real-time localized delivery of micromolar dopamine concentrations and demonstrated qualitative responsiveness of the integrated optical signal to delivered dopamine as a proof-of-concept for the platform. The platform functions as a spatially resolved mass integrator while simultaneously decoupling this chemical signal from transient hydrodynamic mechanical deformations caused by dopamine injection flow. Ultimately, this platform establishes the fundamental methodology required for future high-throughput spatial monitoring of complex neurotransmitter release dynamics across cellular networks.

  • Open Access

    Real-Time and Spatially Resolved Analysis of Ion (De)Intercalation in Nickel Hexacyanoferrate Nanofilms Using Plasmonic Electrochemical Microscopy

    by Adaly Garcia, Samuel Groysman, Tiffany Smith, Matthew Serrano, Christian Martinez, Alston Tang, John Christopher Bachman, Yixian Wang

    Nickel hexacyanoferrate (NiHCF), a Prussian blue analog, is a promising electrode material for energy storage and ion separation technologies. Studying the ion (de)intercalation process in NiHCF films is critical because the reversible insertion and removal of ions into its crystal lattice governs the material's performance in applications such as sodium-ion batteries, electrochromic devices, and selective ion sensing. However, conventional analytical techniques are limited to bulk measurements, which average the electrochemical response and obscure the critical role of local heterogeneities, such as defects and grain boundaries. To overcome this, we employ plasmonic electrochemical microscopy (PEM), a technique that spatially resolves refractive index changes, to study NiHCF films with high resolution. We demonstrate the unique capabilities of PEM to monitor the electrodeposition process in real time, visualize heterogeneous ion (de)intercalation dynamics and their correlation with film thickness and local ion concentrations, and generate a spatially resolved electrochemical impedance map of NiHCF. This provides unprecedented insight into local charge transfer kinetics and establishes PEM as a powerful methodology for deconvoluting complex, localized phenomena in energy storage materials, paving the way for the rational design of more efficient electrodes.


  • Proton-Transfer Kinetics at Liquid–Liquid Interfaces

    by Nick D’aNtona, Joseph Kelly, Nadia Barnard, Shane Ardo, Yixian Wang, Yogesh Surendranath, Thomas E. Markland, Paul A. Kempler, Shannon W. Boettcher

    Proton transfer at electrochemical interfaces is fundamentally important across science and technology, yet kinetic measurements of this elementary step at electrode|electrolyte interfaces are convoluted with other electron-transfer steps and by inhomogeneous electrode surfaces. We use facilitated proton transfer at the interface between two immiscible electrolyte solutions (ITIES) as a platform to study proton-transfer kinetics in the absence of interfacial electron transfer and without the defects at solid|electrolyte interfaces. Diffusion-controlled micropipette voltammetry revealed that 2,6-diphenylpyridine (DPP) facilitates proton transfer across the HCl(aq)|trifluorotoluene interface, while voltammetry at nanopipette-supported interfaces yielded activation-controlled ion-transfer currents. We extract kinetic parameters kapp0 and αapp, 3.0 ± 1.8 cm/s and 0.3 ± 0.2, respectively, for DPP-facilitated proton transfer by fitting quasi-reversible voltammograms to a mixed diffusive-kinetic model. Finite-element simulations highlighted regimes of direct proton transfer and sequential proton transfer, where the current divided between these two possible pathways was shown to favor direct proton transfer when the neutral partitioning step DPP(org) → DPP(aq) was rate-determining. Atomistic molecular-dynamics simulations were used to compute the free energy change to move DPP and its protonated analogue within, and across, the liquid|liquid interface. The most-likely location for proton transfer is predicted to be in the surface region where significant interpenetration of the two liquids occurs. Understanding the kinetics of ion transfer at the ITIES illustrated here is important in the development of general theories of ion transfer in electrochemical science and technology.


  • Open Access

    Proton-transfer kinetics at liquid-liquid interfaces

    by Nick D'ANtona, Joseph Kelly, Nadia Barnard, Shane Ardo, Yixian Wang, Yogesh Surendranath, Tom Markland, Paul Kempler, Shannon Boettcher

    Proton transfer at electrochemical interfaces is fundamentally important across science and technology, yet kinetic measurements of this elementary step at electrode|electrolyte interfaces are convoluted with other electron-transfer steps and by inhomogeneous electrode surfaces. We use facilitated proton transfer at the interface between two immiscible electrolyte solutions (ITIES) as a platform to study proton-transfer kinetics in the absence of interfacial electron-transfer and without the defects at solid|electrolyte interfaces. Diffusion-controlled micropipette voltammetry revealed that 2,6-diphenylpyridine (DPP) facilitates proton-transfer across the HCl(aq)|trifluorotoluene interface while voltammetry at nanopipette-supported interfaces yielded activation-controlled ion-transfer currents. We extract kinetic parameters k_app^0 and α_app, 3.0 +/- 1.8 cm/s and 0.3 +/- 0.2, respectively, for DPP-facilitated proton transfer by fitting quasi-reversible voltammograms to a mixed diffusive-kinetic model. Finite-element simulations highlighted regimes of direct proton transfer and sequential proton transfer, where the current divided between these two possible pathways was shown to favor direct proton transfer when the neutral partitioning step DPP(org) DPP(aq) was rate determining. Atomistic molecular-dynamics simulations were used to compute the free-energy change to move DPP and its protonated analogue within, and across, the liquid|liquid interface. The most likely location for proton transfer is predicted to be in the surface region where significant interpenetration of the two liquids occurs. Understanding the kinetics of ion transfer at the ITIES illustrated here is important in the development of general theories of ion transfer in electrochemical science and technology.

  • Open Access

    Teaching the concepts of Donnan potential and liquid-junction potential by evaluating homemade pH and ion-sensitive probes constructed using commercial ion-exchange membranes and reference electrodes

    by William Gaieck, Anni Zhang, Ashley Sabatose, Madison Ngo, Eric Schwartz, William White, Simon Luo, Leanna Schulte, Yixian Wang, Shane Ardo

    Transport of ions across semipermeable membranes, like ion-exchange membranes, and salt bridges, like porous frits, can each results in electric potential differences that are sensed in most electrochemical experiments. While often neglected by electrochemists, these electric potential differences can significantly impact the interpretation of experimental results. To assist in comprehension of these concepts, which are pertinent to the electrochemistry of many aqueous chemical systems, we designed, implemented, and evaluated a several-hours-long hands-on laboratory activity that we performed with undergraduate and graduate students in electroanalytical chemistry courses. The activity requires that students construct a simple two-compartment electrochemical cell from inexpensive and readily available disposable plastic cuvettes, commercially available polymeric ion-exchange membranes, two nominally identical reference electrodes placed in liquid electrolytes that wet each side of the membrane, and a voltmeter or a potentiostat to measure the open-circuit potential between the reference electrodes, i.e. the cell potential. Using commercially available reference electrodes, each consisting of a wire (e.g. Ag/AgCl) immersed in a fritted tube containing an aqueous electrolyte, measured open-circuit potentials report on the magnitude of both Donnan and liquid-junction electric potential differences. These electric potentials are dictated by the composition of ions in each electrolyte, through interactions with the ion-exchange membrane and porous frits at the tip of each reference electrode. When a cation-exchange membrane separates aqueous solutions consisting of different concentrations of hydrochloric acid (HCl) or potassium hydroxide (KOH), the cell responds like a pH or pK probe, respectively, because the membrane interfaces are more sensitive to the activity of H+ and K+ over Cl– and OH–, respectively. Analogously, when an anion-exchange membrane is used, the cell should respond like a pCl or pOH probe, respectively, because the membrane interfaces are more sensitive to the respective activity of Cl– and OH– over H+ and K+. When the solutions contain large concentrations of multiple types of ions, measured open-circuit potentials typically deviate from values dominated by Donnan potential differences and are instead dominated by liquid-junction-like effects where electric potentials within and across ion-exchange membranes form due to differences in permeabilities of the ions. When reference electrodes consist of wires immersed directly into the aqueous electrolytes that wet the membranes, and not in fritted tubes, measured open-circuit potentials also include contributions from the chemical potential of redox-active species that are present in the aqueous electrolytes as Nernst potentials. While this hands-on laboratory activity is suitable for most upper-level undergraduate students in physical science and engineering disciplines, the concepts of Donnan electric potential, liquid-junction electric potential, and species chemical potential are advanced enough to educate graduate students and senior researchers alike. Student feedback obtained using surveys given before and after the laboratory activity provides additional guidance to instructors who plan to implement our activity.


  • Open Access

    Sensitive Imaging of Electroactive Species in Plasmonic Electrochemical Microscopy Enabled by Nanoconfinement

    by Samuel Groysman, Yisi Chen, Adaly Garcia, Christian Martinez, Kevin Diego-Perez, Miriam Benavides, Yi Chen, Zijian Wan, Shaopeng Wang, Rujia Liu, et al.

    Spatially resolved sensing is a burgeoning area of electrochemistry that, in contrast to traditional electrochemical techniques, allows for the analysis of heterogeneous systems such as neurotransmitter release from cells. Of these techniques, optical microscopy methods are valued for real-time high throughput sensing. However, improving the sensitivity of many optical techniques remains a challenge. Here, we modify the gold (Au) electrode of the standard plasmonic electrochemical microscopy (PEM) setup with a mesoporous silica film (MSF) to achieve sensitive imaging of the electroactive species. Sensitivity enhancement occurs via species nanoconfinement from the attraction of ions to the negatively charged silica films, thereby increasing the local concentration change and magnifying the PEM signal. The performance of Au-MSF electrodes in the PEM setup was investigated using 1,1′-ferrocenedimethanol, whose oxidized form carries a positive charge. Results revealed enhancement of the sensing signal, with up to 37-fold improvement in the detection limit and up to 23 times improvement in the sensitivity. Importantly, Au-MSF electrodes allowed for the quantification of detected concentrations, in contrast to Au electrodes, for which R2 values were unacceptably low. Furthermore, Au-MSF electrodes also showed increased sensitivity for dopamine detection compared to Au electrodes and were able to visualize localized dopamine release, showing this setup’s great promise for biological applications, such as real-time imaging of the neurotransmitter release.


  • Open Access

    Prussian blue nanofilm-sensitized plasmonic electrochemical microscopy for spatially resolved detection of the localized delivery of hydrogen peroxide

    by Adaly Garcia, Christina Dhoj, Samuel Groysman, Kinsley Wang, Stellina Ao, Aimee Anguiano, Tony Tran, Dianlu Jiang, Yixian Wang


  • Scanning ion conductance microscopy reveals differential effect of PM2.5 exposure on A549 lung epithelial and SH-SY5Y neuroblastoma cell membranes

    by Christina Dhoj, Adaly Garcia, Artur Manasyan, Miriam Benavides, Dana Abou Abbas, Cindy Toscano, Edith Porter, Yixian Wang

    Numerous studies have linked a wide range of diseases including respiratory illnesses to harmful particulate matter (PM) emissions indoors and outdoors, such as incense PM and industrial PM. Because of their ability to penetrate the lower respiratory tract and the circulatory system, fine particles with diameters of 2.5 µm or less (PM2.5) are believed to be more hazardous than larger PMs. Despite the enormous number of studies focusing on the intracellular processes associated with PM2.5 exposure, there have been limited reports studying the biophysical properties of cell membranes, such as nanoscale morphological changes induced by PM2.5. Our study assesses the membrane topographical and structural effects of PM2.5 from incense PM2.5 exposure in real time on A549 lung carcinoma epithelial cells and SH-SY5Y neuroblastoma cells that had been fixed to preclude adaptive cell responses. The size distribution and mechanical properties of the PM2.5 sample were characterized with atomic force microscopy (AFM). Nanoscale morphological monitoring of the cell membranes utilizing scanning ion conductance microscopy (SICM) indicated statistically significant increasing membrane roughness at A549 cells at half an hour of exposure and visible damage at 4 h of exposure. In contrast, no significant increase in roughness was observed on SH-SY5Y cells after half an hour of PM2.5 exposure, although continued exposure to PM2.5 for up to 4 h affected an expansion of lesions already present before exposure commenced. These findings suggest that A549 cell membranes are more susceptible to structural damage by PM2.5 compared to SH-SY5Y cell membranes, corroborating more enhanced susceptibility of airway epithelial cells to exposure to PM2.5 than neuronal cells. Graphical abstract