Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ayman M. Okeil has a total of 104 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Calibration of Resistance Factors for CFRP Pretensioned and Post-Tensioned Bridge Girders

    by Bo-Tong Zheng, Bora Gencturk, Abdeldjelil Belarbi, Ayman Okeil, Mahmoud R. Manaa

    This paper presents a comprehensive reliability analysis of concrete bridge girders reinforced with bonded pretensioned and unbonded post-tensioned carbon fiber–reinforced polymer (CFRP) reinforcement. Recognizing the distinct mechanical behavior of pretensioned and post-tensioned girders, separate analyses were conducted to calibrate their respective flexural resistance factors. Both analyses were based on the widely accepted load model incorporated in the AASHTO Load and Resistance Factor Design (LRFD) Bridge Design Specifications for girder design. For pretensioned girders, this study extends prior reliability research by updating the probabilistic parameters of the prestressing CFRP and recalibrating the professional factor using newly available experimental and numerical data. A flexural resistance factor of 0.75 is proposed for tension-controlled failure within the current AASHTO LRFD reliability framework based on the primary target reliability index of β = 3.5. The results corresponding to β = 4.0 are also reported as a conservative reference for less ductile CFRP rupture-controlled failure mode for a bridge structure with high importance and low redundancy. This work also marks the first reliability analysis in the literature for unbonded CFRP post-tensioned girders. A flexural resistance factor of 0.75 is recommended for compression-controlled failure, and because the unbonded CFRP tendons experience limited stress increase under flexural action, tension-controlled failure is difficult to achieve and therefore it was not considered in this study. These results provide guidance for the design of CFRP-prestressed concrete girders, contributing to advancements in bridge engineering and the implementation of CFRP in structural applications.

  • Finite element modeling of mixed adhesive layer fracture mode for FRP web strengthening of steel bridges

    by Ayman M. Okeil, Tuna Ülger

    Buckling of thin-walled web plates of steel girders can be delayed using bonded glass fiber reinforced plastic (GFRP) stiffeners using the strengthening-by-stiffening (SBS) strengthening technique. The stress state between the bonded adherents (steel web and GFRP stiffener) is complex, varies greatly pre- and post-buckling, and causes adhesion- and/or cohesion-dominant failure modes. Full-scale experiments of SBS-strengthened steel beams showed a need to investigate the fracture mode of the adhesive layer. A finite element model of the full-scale beams was built to study the adhesive layer using sub-modeling techniques considering different steel plate thicknesses, epoxy types, and initial crack to determine the phase angle shift during web buckling. It was observed that the SBS failure is controlled by a mixed mode that starts initially with a phase angle of 29°; i.e., Mode II is the dominant failure mode during the linear phase. Thereafter, Mode I with a 59° phase angle became prevalent during the nonlinear phase of the behavior implying that the buckling-driven failure of web plate changes the phase angle.

  • Shear Performance of Steel Beams with Bonded GFRP Stiffeners: Weathering and Cyclic Load Effects

    by Tuna Ulger, Ayman M. Okeil

    Strengthening-by-stiffening (SBS) is a technique for enhancing the shear performance of buckling-prone webs of steel beams by bonding glass fiber–reinforced polymer (GFRP) stiffeners. This paper focuses on changes in load capacity, ductility, and mode of failure of SBS under cyclic loading and after exposure to weathering conditions for 1 year. First, weathering effects on mechanical properties of the adhesive used in bonding the GFRP stiffeners are presented. The ductility of the epoxy was significantly reduced; however, the ultimate stress increased by about 68% over the ultimate stress of the nonweathered coupons. Furthermore, weathering led to the formation of a thin film of rust that propagated around the edges of the bonding adhesive for the full-scale beams. Consequently, the ultimate load capacity of the weathered beam dropped about 11% after 1 year of environmental exposure. Cyclic loading, however, resulted in negligible change in the ultimate load capacity. For all tested beams, the ductile adhesive used in bonding the GFRP stiffeners prevented a sudden drop in load capacity due to debonding of the GFRP stiffener in all tests.


  • Calibration of Temperature Gradient Load Factor for Service Limit State Design of Concrete Slab-on-Girder Bridges

    by Ahmed Elshoura, Ayman M. Okeil

    Design factors in load and resistance factor design (LRFD) codes are determined using structural reliability theory to account for the uncertainties in loads and resistance. The calibration of load factors for strength limit states has been investigated during the development of AASHTO LRFD bridge design specifications (BDS). In comparison, sparse efforts can be found for calibrating service limit state load factors. Temperature variations affect all types of bridges and cause additional stresses, deformations, and moments in different bridge components. Calibration of load factors for vertical temperature gradients appear to be lacking for both strength and service limit states. This paper focuses on calibrating positive vertical temperature gradient load factors for the Service III limit state. A design space consisting of 70 two-span continuous bridges with different bridge configurations is established and designed for severe corrosive exposure conditions. Design stresses for various load cases are first calculated. Using the first-order reliability method (FORM) and considering the sources of uncertainties due to materials, fabrication, and load effects, temperature gradient load factors were then calibrated for different risk levels. The results show that vertical temperature gradient load factors between 1.00 and 1.40 should be used for the Service III limit state.


  • Simplified method for estimating restraint moment induced by vertical temperature gradient in continuous prestressed concrete bridges and verification using AASHTO BDS

    by Ahmed Elshoura, Ayman M. Okeil

    Diurnal and seasonal temperature variations cause uniform temperature changes, vertical temperature gradients, and horizontal temperature gradients. Vertical temperature gradients occur when the bridge deck absorbs heat due to solar radiation more than the bottom parts of bridge girders. Consequently, the vertical temperature gradient causes redistribution of bearing reactions, and induces additional flexural stresses in continuous spans. Estimating the vertical temperature gradient effect on continuous concrete bridges requires knowledge of thermal analysis of statically indeterminate structures or advanced three-dimensional (3 D) finite element (FE) analysis. Therefore, this article focuses on developing a simplified analysis method for estimating vertical temperature variations effects on continuous prestressed concrete bridge girders, which is required for bridge design. Restraint moments induced by vertical temperature gradients are investigated using 3 D FE analysis. A total of 115 bridges with different configurations (number of spans, girder spacing, and girder type) were analyzed to estimate the positive thermal moments at support locations. Results from these analyses were then used to develop simplified equations for estimating the positive restraint moments due to vertical temperature gradients from AASHTO LRFD Bridge Design Specifications (BDS). The developed equations are validated using John James Audubon Bridge #2 field data, and for other AASHTO LRFD temperature zones.


  • Study of Statistical Uncertainties for Temperature Gradients in Concrete Bridges

    by Ahmed Elshoura, Ayman M. Okeil

    The philosophy currently adopted by AASHTO Bridge Design Specifications (BDS) is based on considering uncertainties inherent in the structural design process by proposing load and resistance factors. Factors used in the load and resistance factor design (LRFD) method are calibrated using theory of reliability. Research efforts to calibrate load factors for gravity loads can be found in the literature; however, calibration of load factors for temperature loads has not received similar attention. Temperature loads are inevitable environmental loads that affect bridges on a daily and diurnal basis, causing additional stresses and deformations. The first step in conducting such a calibration is to understand the uncertainties inherent therein. This study established a methodology for determining the probability distribution of maximum daily temperature gradient in slab-on-girder concrete bridges using temperature data from the John James Audubon Bridge in south Louisiana. Field data from a finite monitoring time period of 5 years were analyzed statistically and then extrapolated to obtain the largest extreme values over the expected design life of the bridge using extreme value theory. Recorded data were used to investigate the best-fit distribution type for maximum daily temperature differences, which revealed that the beta distribution type is the best fit for maximum daily temperature data. The largest extreme maximum daily temperature difference values were determined using the peak over threshold (POT) method. Extrapolated temperature gradients, that is, the largest extreme maximum daily temperature difference values, were found to be best represented by a Gumbel distribution.