ZSZongqian Shi

Zongqian Shi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zongqian Shi has a total of 161 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Experimental investigation on the motion characteristics of multi-cathode spot of free-burning vacuum arc

    by Jinhong Liu, Yongpeng Mo, Junhao Niu, Siyuan Ju, Zongqian Shi, Shixin Xiu

    The motion of cathode spots of vacuum arc is highly complex, and mutual interactions exist among individual spots. In order to achieve a more comprehensive investigation of the motion characteristics of multiple cathode spots, triggered arc experiments using the plate contacts were conducted in this work to study the evolution behavior of multiple cathode spots. Furthermore, a multi-target tracking algorithm based on the region growing and intersection over union was proposed, enabling the localization and motion tracking of multiple cathode spots. Experimental results indicate that, under free-burning arc conditions, the self-generated transverse magnetic field (TMF) of cathode spots is consistent with the motion behavior of cathode spots. When the TMF is relatively weak, cathode spots tend to exhibit random motion. When the TMF increases, the retrograde motion of cathode spots occurs. The TMF at cathode spots located closer to the contact center is relatively weak, whereas the TMF is stronger at cathode spots farther from the center. As a result, cathode spots near the contact center are more likely to exhibit random motion, while those farther from the center tend to exhibit retrograde motion, that is, to diffuse outward. The diffusion of cathode spots is associated with the retrograde motion and splitting of spots located farther from the contact center. Larger peak current may accelerate the diffusion process by increasing the average cathode spot current to enhance the magnetic field and promoting cathode spot splitting.

  • A novel contactless detection approach for vacuum pressure based on the Pirani-permanent magnet principle

    by Xutong Jin, Zongqian Shi, Yongpeng Mo, Jiajia Sun

    Vacuum system finds increasingly widespread application across diverse industries. Precise measurement of vacuum pressure is essential for ensuring the safe and reliable operation of technologies and equipment. For fully sealed or online-operating vacuum chambers, detecting and assessing the internal vacuum state without compromising the structure or functionality of the chamber holds significant importance. This paper proposes a novel contactless online vacuum detection method that combines the temperature characteristics of permanent magnets, electromagnetic induction and the Pirani principle. The AC coil outside the vacuum chamber heats the internal permanent magnet by generating eddy currents. By detecting variations in the electromagnetic force between the permanent magnet and the external DC coil during the cooling process, vacuum pressure is determined. Slower changes in electromagnetic force indicate lower vacuum pressure. This approach offers simpler operation, lower cost, and broader applicability without requiring complex instrumentation. Based on theoretical research and COMSOL simulation design, the proposed contactless vacuum detection method is expected to detect vacuum pressures as low as 10 −2 Pa–10 Pa.

  • Fe3O4@Au Magnetic–Plasmonic Nanoparticles Self-Assembled into Gammadion-Shaped Nanostructures in a Gradient Magnetic Field for High-Sensitivity Optical Sensing

    by Jiajia Sun, Xinxiao Shui, Zongqian Shi, Wanyi Du, Shumin Xin, Ruixuan Zhao, Ruichen Wang, Qinyuan Xian, Xinran Shen, Yan Wang

    Most of the bottom-up approaches, such as light-induced, capillarity-assisted, and electric or magnetic field-assisted assembly methods, have been carried out in fabricating crystalline structures, which can exhibit unique optical, magnetic, or electrical properties. Among them, the magnetic field-driven self-assembly of magnetic–plasmonic nanoparticles (Fe3O4@Au) provides an adaptive approach for constructing metamaterials with peculiar optical and photothermal properties due to their localized surface plasmon resonance and magnetic drivability. Here, a microfluidic and magnetic template-assisted self-assembly protocol is proposed to form a gammadion-shaped nanostructure consisting of magnetic–plasmonic nanoparticles. This approach leverages strong magnetic field gradients and the mechanical constraints of specially designed traps to precisely control the assembly process of Fe3O4@Au nanoparticles. Lagrangian–Eulerian analysis and full-wave field theory are combined to investigate the self-assembly and optical behaviors of the nanostructure, respectively. These gammadion-shaped nanostructures can be transferred onto various substrates and exhibit remarkable tunability in optical responses. Experimentally, micronano fabrication techniques were employed to fabricate gammadion-shaped magnetic templates, and Fe3O4@Au nanoparticle assemblies were obtained under an external bias magnetic field, with SEM characterization preliminarily confirming the feasibility of the proposed strategy. Numerical simulations further reveal that, under external illumination, strong near-field coupling between adjacent nanoparticles generates significant localized electric field enhancement, making these structures promising candidates for high-sensitivity optical sensing and potential SERS-based molecular detection. Specifically, when transferred onto a glass substrate, the maximum field intensity at the interparticle “hot spots” reaches 8 × 109 V·m–1. Furthermore, when the structure is transferred onto a dielectric Al2O3 layer with an Au backplate, this metal–insulator–metal (MIM) structure achieves near-perfect absorption of light (absorptivity enhanced to 0.97) at a resonance wavelength of 2 μm, and the sensitivity at 2.34 μm reaches 1777.8 nm/RIU. This research provides a pathway for the efficient construction of asymmetric nanostructures and lays a solid theoretical foundation for the development of multifunctional metamaterials.


  • Open Access

    Study on the reignition phase and magnetic field simulation of drawn vacuum arc in 126 kV axial magnetic field contacts

    by Yiming Ding, Zongqian Shi, Yongpeng Mo, Ruiqi Liu, Junhao Niu, Benfu Zhu, Qinyuan Xian

    With the increase in breaking voltage level, studying the evolution characteristics of reignition of high-current vacuum arc plays an important role to improve the breaking capacity of vacuum circuit breakers. In order to analyze the characteristics of the arc in the reignition phase of 126 kV axial magnetic field (AMF) contacts, drawn vacuum arc experiments were conducted in a detachable vacuum chamber and magnetic field simulations were performed under corresponding conditions. By analyzing the arc images and arc-voltage characteristic of high-current interruption experiments with a pair of 140-mm-diameter cup-type six-slot AMF contact, the arcing reignition process in the second half-wave can be divided into four stages, i.e., reignition stage, disordered movement stage, dispersed arc stage, transition stage, and diffused arc stage. Combined with the magnetic field simulation analysis, at the beginning of the second half-wave just after current zero, the axial magnetic field is weak, resulting in poor control over the arc, while the transverse magnetic field is strong, promoting rotational motion of the arc along the contact surface. In this process, the arc voltage presents significant noise. As the current increases and the axial magnetic field strengthens, the control of the arc gradually improves. The arc transitions from dispersed mode to diffused mode after the current peak. At the same time, cathode spots continuously spread on the contact surface, the arc voltage gradually becomes stable, and the arc extinguishes at the second current zero.


  • Open Access

    Numerical and Experimental Analysis of Microparticle Focusing and Separation in Split–Recombination Microchannel

    by Shuang Chen, Jiajia Sun, Zongqian Shi, Lijie Sun, Junxiong Guo

    Inertial microfluidics has obtained attention for its good performance in microparticle manipulation. It has the advantages of simplicity, high throughput, and a lack of external fields. In this paper, a simple microfluidic device is described, which contains several split and recombination structures. The design takes advantage of microparticle migration based on inertial lift and the Dean drag force. Two forces drive microparticles to move laterally and arrive at equilibrium positions in a split–recombination microchannel. Based on the numerical and experimental analysis, the trajectories of microparticles are described, and microparticles are focused and form two narrow streams. In addition, the focusing of microparticles is enhanced significantly with the increase in angle. Finally, two sizes of microparticles are separated in experiments. The simple device and high throughput offered by this passive microfluidic approach make it attractive in biomedical and environmental applications.

  • Study on the Influence of Electrode Materials in the Low-Voltage Pulsed Submerged Arc Plasma Degradation of Methylene Blue

    by Yongpeng Mo, Zhang Jiajian, Xi Yu, Jinhong Liu, Honghao Chen, Rongzhao Jia, Zongqian Shi

    Low-voltage pulsed submerged arc (SA) plasma discharge is promising for water treatment due to its cost-effectiveness and high degradation efficiency. This study investigated methylene blue (MB) degradation with different electrode pairs, including graphite and iron as anodes, and iron, titanium, and tungsten as cathodes. A maximum removal ratio of 99.39% was achieved with a tungsten cathode and iron anode in 70 seconds. The experimental results indicated that electrode erosion might contributes to MB removal through adsorption and chemical reactions. Besides, the iron ion hydrolysis produced flocculent precipitates, which will further improve the MB degradation. This study provides insights into electrode material selection and the mechanisms influencing MB degradation.

  • Study on the Drawn Vacuum Arc Characteristics of the 126 kV Axial Magnetic Field Contacts

    by Jiaxi Shi, Yongpeng Mo, Haibo Su, Siyuan Ju, Tao Tan, Rongzhao Jia, Yisheng Li, Yiming Ding, Zongqian Shi, Shenli Jia

    During the current interruption process, the vacuum arc evolution characteristics are crucial in determining whether a vacuum circuit breaker can interrupt the current successfully. In order to analyze the expansion characteristics of cathode spots (CSs) on the 126 kV axial magnetic field (AMF) contacts, the drawn vacuum arc experiments were conducted. To observe more characteristics of the drawn vacuum arc, two high-speed cameras were used simultaneously to capture the dynamics of both the vacuum arc and CSs. The experimental results indicated that the vacuum arc column could not expand sufficiently to cover the entire contact surface. Additionally, multiple types of vacuum arc column modes occurred in the experiments, and the number of ignition positions also affected both the appearance of vacuum arc and the diffusion process of CSs. Moreover, the magnetic field distribution under different vacuum arc column modes was simulated. In the contact surface near the contact edge, the AMF components are smaller than the transverse magnetic field (TMF) components and these lead a rapid radial expansion of CSs. Furthermore, significant deflection occurs for CSs located in central area on both cup-type AMF contact and coil-type contacts. However, the CSs of these two types of contacts show different deflection directions. When the total arc area remains constant but the number of arc columns increases, the TMF components decreases and radial velocity of CSs also decrease. The simulation results also indicated that the variation in the number of arc columns has a relatively small impact on the distribution of the AMF component.


  • Dual-Band Terahertz Toroidal Metamaterial Biosensor for Detection of Bovine Serum Albumin (BSA) With Ultrahigh Sensitivity

    by Xiaofeng Liu, Jiajia Sun, Zongqian Shi, Chenglin Yang, Yushan Hou, Liuyang Zhang, Shixin Xiu

    The terahertz (THz) metamaterial sensor represents an innovative technology designed to achieve superior sensitivity for trace detection by combining the advantages of THz spectroscopy and metamaterials. Specially, the THz metamaterial sensors based on toroidal dipole resonances effectively reduce the radiative loss, making them highly promising for sensing applications. In this study, we propose a novel dual-band toroidal metamaterial consisting of an array of two sets of three strips, which induces strong field confinement between the metal strips. The electric field analysis at the resonant frequencies and the scattered power distributions of multipoles illustrate the generation of the toroidal dipole and enhanced sensing performance. Furthermore, the proposed dual-band toroidal metamaterial sensor exhibits high sensitivity to environmental perturbations, reaching up to 58GHz/RIU at mode I and 71 GHz/RIU at mode II under a 100 nm coating analyte thickness, outperforming the sensitivity of metal-insulator-metal (MIM) metamaterial. In addition, the metamaterial sample is fabricated using a maskless laser direct write lithography system, and its resonant spectra are measured using terahertz time-domain spectroscopy (THz-TDS). The sensing performance of the proposed dual-band toroidal metamaterial sensor is experimentally demonstrated through detecting SiO2 layers with varying thicknesses, with results showing strong agreement with simulations. Furthermore, the proposed sensor is utilized for detecting bovine serum albumin (BSA) concentrations in the range of 0.1 μg/mL to 100 μg/mL with a LOD of 5.4 pg/mL for mode I and 3.4 pg/mL for mode II. The proposed dual-band metamaterial sensor provides a powerful approach for THz sensing, significantly improving biosensing sensitivity.


  • Study on the Removal of Methylene Blue by a Low-Voltage Submerged Arc Generated by the Graphite Electrodes

    by Xi Yu, Yongpeng Mo, Honghao Chen, Jiajian Zhang, Shenli Jia, Zongqian Shi

    Plasma generated by a submerged arc has great potential in wastewater treatment. Carbon is widespread in nature. It is easily acquired and biocompatible. In this article, a low-voltage submerged arc generated by contact-separate of two electrodes is proposed to decompose methylene blue (MB). The process achieved a removal efficiency of 92.9% after 15 min treatment. The emission spectrum of the submerged arc indicated that active particles such as $\cdot $ OH radicals, oxygen atoms, and hydrogen peroxide (H2O2) have been produced. Additionally, in the process of arc treatment, the wavelength of the absorption peak of MB solution shifted toward ultraviolet region. It indicated the demethylation of the MB molecules. The eroded particles from the graphite electrodes were also examined, and the carbon quantum dots were observed. Furthermore, micro-scale fibrous entangled particles and layered particles with abundant pore structures were observed. These results demonstrate that the eroded particles own an absorption ability for MB, continuing decolorization of the treated solution without additional active particles generated by the submerged arc plasma.