Takashi Hori
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Takashi Hori has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Junya Fukuoka
Department of Pathology Informatics, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
4 shared publications Eiichi Nakayama
2 shared publicationsKoji Kurose
2 shared publicationsMidori Isobe
2 shared publications- Mikio Oka
Department of Immuno-Oncology, Kawasaki Medical School, Kurashiki, Japan
2 shared publications Ryohei Nozawa
2 shared publications
Latest Publications
- Open Access
- 29 August 2013
- Published by Wiley in BioMed Research International
- Vol. 2013, 1-5
Difference of Morphology and Immunophenotype between Central and Peripheral Squamous Cell Carcinomas of the Lung
Background. Recent agents, that is, pemetrexed and bevacizumab, have shown reproductive negative association between squamous histology. According to these agents' effectiveness, ruling out of the squamous histology is a significant issue for surgical pathologists. Several articles have proposed the distinction of peripheral type from central type of squamous cell carcinoma (SqCC) due to its similarity to adenocarcinoma, although little evidence to support the difference between these two types was published. In this study, we compared the clinicopathologic findings of central and peripheral pulmonary SqCCs.Material and Methods. 15 central and 35 peripheral types of SqCC from 2005 to 2010 were examined. Twelve morphological features were scored based on their intensity in the original H&E slides, and then, tissue microarray holding triplicated cores from 43 cases was immunohistochemically examined for cytokeratin (CK)7, CK14, TTF-1, Napsin A, p63, CK34βE12, CK5/6, and p53.Result. Most of the histological findings did not separate central and peripheral SqCCs; only the presence of emphysema, interstitial fibrosis, and entrapped pneumocytes inside the tumor showed statistic predominance in peripheral SqCC. This is the first immunophenotypic research in the central and peripheral types of SqCC.
- 29 August 2013
- Published by Wiley in BioMed Research International
- Vol. 2013, 1-5
Open AccessDifference of Morphology and Immunophenotype between Central and Peripheral Squamous Cell Carcinomas of the Lung
Background. Recent agents, that is, pemetrexed and bevacizumab, have shown reproductive negative association between squamous histology. According to these agents' effectiveness, ruling out of the squamous histology is a significant issue for surgical pathologists. Several articles have proposed the distinction of peripheral type from central type of squamous cell carcinoma (SqCC) due to its similarity to adenocarcinoma, although little evidence to support the difference between these two types was published. In this study, we compared the clinicopathologic findings of central and peripheral pulmonary SqCCs.Material and Methods. 15 central and 35 peripheral types of SqCC from 2005 to 2010 were examined. Twelve morphological features were scored based on their intensity in the original H&E slides, and then, tissue microarray holding triplicated cores from 43 cases was immunohistochemically examined for cytokeratin (CK)7, CK14, TTF-1, Napsin A, p63, CK34βE12, CK5/6, and p53.Result. Most of the histological findings did not separate central and peripheral SqCCs; only the presence of emphysema, interstitial fibrosis, and entrapped pneumocytes inside the tumor showed statistic predominance in peripheral SqCC. This is the first immunophenotypic research in the central and peripheral types of SqCC.
- 15 April 2012
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 72 (8_Suppleme) , 2377
Abstract 2377: New micro-fluidic devices with polymeric materials for isolation of circulating tumor cells
Introduction: Circulating tumor cells (CTCs) have been isolated from peripheral blood of cancer patients using cell detection and capture system, however the machine itself and the running costs are expensive. Thus a low cost device has been desired. Recently, a micro-fluidic device has been introduced. In this study, we would like to present a new micro-fluidic device with polymeric materials for isolation of circulating tumor cells. The IRB approval number was #21-88. Materials & Methods: We prepared a micro-fluidic device with the structures imprinted using a mold on the resin followed by UV-light curing in a couple of minutes. The resin contained a monomer having an epoxy group which enabled the device surface to react with other functional groups for immobilization of antibodies. The antibodies were immobilized not directly but with polymers to the surface. Polyacrylic acid (Mw:5,000) was grafted to the device surface by the reaction of the carboxyl group and the surface epoxy group, then IgG antibodies were covalently bonded to the polymer with the condensation agent for amino and carboxyl groups. Finally, EpCAM antibodies were attached to the IgG antibodies in the polymer. Results: Esophageal cancer cells KYSE220 dispersed in phosphate buffered saline (PBS) at a concentration of 1000 cells/ml were flowed through the CTC capture device described above at a rate of 1ml/hour. After cells passed, we observed many cells captured on the microstructure of the device, whereas no cells were seen without EpCAM antibodies on the device surface. We could evaluate the trapped cells by a quick cell stain method or fluorescent staining. We also detected KYSE220 cells in the healthy whole blood or selected nuclear cell separation. We have just started to evaluate this for detection of CTC in cancer patients. The cost of the new device was 10 dollar for each chip excluding the cost of the antibody. Conclusion: We developed a new micro-fluidic device with polymeric materials for isolation of circulating tumor cells. This new chip may be useful for isolation of CTC at a low cost. Citation Format: {Authors}. {Abstract title} [abstract]. In: Proceedings of the 103rd Annual Meeting of the American Association for Cancer Research; 2012 Mar 31-Apr 4; Chicago, IL. Philadelphia (PA): AACR; Cancer Res 2012;72(8 Suppl):Abstract nr 2377. doi:1538-7445.AM2012-2377
- 15 April 2012
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 72 (8_Suppleme) , 2377
Abstract 2377: New micro-fluidic devices with polymeric materials for isolation of circulating tumor cells
Introduction: Circulating tumor cells (CTCs) have been isolated from peripheral blood of cancer patients using cell detection and capture system, however the machine itself and the running costs are expensive. Thus a low cost device has been desired. Recently, a micro-fluidic device has been introduced. In this study, we would like to present a new micro-fluidic device with polymeric materials for isolation of circulating tumor cells. The IRB approval number was #21-88. Materials & Methods: We prepared a micro-fluidic device with the structures imprinted using a mold on the resin followed by UV-light curing in a couple of minutes. The resin contained a monomer having an epoxy group which enabled the device surface to react with other functional groups for immobilization of antibodies. The antibodies were immobilized not directly but with polymers to the surface. Polyacrylic acid (Mw:5,000) was grafted to the device surface by the reaction of the carboxyl group and the surface epoxy group, then IgG antibodies were covalently bonded to the polymer with the condensation agent for amino and carboxyl groups. Finally, EpCAM antibodies were attached to the IgG antibodies in the polymer. Results: Esophageal cancer cells KYSE220 dispersed in phosphate buffered saline (PBS) at a concentration of 1000 cells/ml were flowed through the CTC capture device described above at a rate of 1ml/hour. After cells passed, we observed many cells captured on the microstructure of the device, whereas no cells were seen without EpCAM antibodies on the device surface. We could evaluate the trapped cells by a quick cell stain method or fluorescent staining. We also detected KYSE220 cells in the healthy whole blood or selected nuclear cell separation. We have just started to evaluate this for detection of CTC in cancer patients. The cost of the new device was 10 dollar for each chip excluding the cost of the antibody. Conclusion: We developed a new micro-fluidic device with polymeric materials for isolation of circulating tumor cells. This new chip may be useful for isolation of CTC at a low cost. Citation Format: {Authors}. {Abstract title} [abstract]. In: Proceedings of the 103rd Annual Meeting of the American Association for Cancer Research; 2012 Mar 31-Apr 4; Chicago, IL. Philadelphia (PA): AACR; Cancer Res 2012;72(8 Suppl):Abstract nr 2377. doi:1538-7445.AM2012-2377