Miriam Farid Ayad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Miriam Farid Ayad has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Maha F. Abdel Ghany
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Cairo, 11566, Egypt
8 shared publications - Mariam M. Tadros
Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Abbassia, Cairo 11566, Egypt
8 shared publications - Nermine Victor Fares
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Abbassia, Cairo 11566, Egypt
8 shared publications Omar Abdel-Aziz
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Abbassia, Cairo, Egypt
8 shared publicationsMaha F. Abdel-Ghany
Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Ain Shams University, Cairo, Egypt
5 shared publicationsLobna A. Hussein
Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Ain Shams University, Cairo, Egypt
4 shared publications
Latest Publications
- 10 December 2025
- Published by Wiley in Luminescence
- Vol. 40 (12) , e70383
Toward Practical and Sensitive Fluorescence Analysis: Factorial Design‐Optimized o ‐Phthalaldehyde Derivatization for Synchronous Spectrofluorimetric Determination of Modafinil in Plasma and Dosage Form
The current research discusses a simple, sensitive, and practical spectrofluorimetric method for Modafinil (MDF) analysis. MDF can improve the fatigue symptoms associated with amyotrophic lateral sclerosis. MDF's aliphatic primary amide moiety can undergo base‐catalyzed condensation with o ‐phthalaldehyde to give a highly fluorescent isoindoline derivative measured at 445 nm using synchronous spectrofluorimetry with Δλ of 110 nm. Different factors were studied using a two‐level factorial design to reach the optimum conditions for the analysis. The method validation was carried out following the International Conference on Harmonization guidelines. The calibration curve was established to illustrate how relative fluorescence intensity varies with MDF concentration, and linearity was attained over the range of 10–7000 ng mL −1 , with an average recovery of 100.51% ± 0.91%. The limit of detection (LOD) was determined to be 3.21 ng mL −1 while the quantitation limit (LOQ) was found to be 9.74 ng mL −1 . The developed method demonstrated its effectiveness in determining MDF in tablets and spiked human plasma with recoveries of 100.43% ± 0.16 and 96.07% ± 1.55, respectively. MoGAPI, AGREE, and BAGI assessments yielded scores of 72, 0.62, and 70, respectively. The results show that the method is user‐friendly and can be used in routine applications.
- 10 December 2025
- Published by Wiley in Luminescence
- Vol. 40 (12) , e70383
Toward Practical and Sensitive Fluorescence Analysis: Factorial Design‐Optimized o ‐Phthalaldehyde Derivatization for Synchronous Spectrofluorimetric Determination of Modafinil in Plasma and Dosage Form
The current research discusses a simple, sensitive, and practical spectrofluorimetric method for Modafinil (MDF) analysis. MDF can improve the fatigue symptoms associated with amyotrophic lateral sclerosis. MDF's aliphatic primary amide moiety can undergo base‐catalyzed condensation with o ‐phthalaldehyde to give a highly fluorescent isoindoline derivative measured at 445 nm using synchronous spectrofluorimetry with Δλ of 110 nm. Different factors were studied using a two‐level factorial design to reach the optimum conditions for the analysis. The method validation was carried out following the International Conference on Harmonization guidelines. The calibration curve was established to illustrate how relative fluorescence intensity varies with MDF concentration, and linearity was attained over the range of 10–7000 ng mL −1 , with an average recovery of 100.51% ± 0.91%. The limit of detection (LOD) was determined to be 3.21 ng mL −1 while the quantitation limit (LOQ) was found to be 9.74 ng mL −1 . The developed method demonstrated its effectiveness in determining MDF in tablets and spiked human plasma with recoveries of 100.43% ± 0.16 and 96.07% ± 1.55, respectively. MoGAPI, AGREE, and BAGI assessments yielded scores of 72, 0.62, and 70, respectively. The results show that the method is user‐friendly and can be used in routine applications.
- 1 September 2025
- Published by Springer Nature in Nature Chemical Biology
- Vol. 21 (11) , 1667-1670
Mass spectrometry and enzyme assays refute histone tyrosine sulfation
- 1 September 2025
- Published by Springer Nature in Nature Chemical Biology
- Vol. 21 (11) , 1667-1670
Mass spectrometry and enzyme assays refute histone tyrosine sulfation
- Open Access
- 23 November 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (12) , 246
Development of All-Solid-State Potentiometric Sensors for Monitoring Carbendazim Residues in Oranges: A Degradation Kinetics Investigation
Monitoring fungicide residues in orange fruits is vital, as fungicides for orange cultivation are increasingly used to prevent yield loss. At the same time, increasing restrictions are added by regulatory organizations. For facile on-site monitoring of the fungicide carbendazim (MBC), five ion-selective potentiometric sensors are proposed and compared. The first two sensors were prepared with a precipitation-based technique using molybdate (sensor 1) and tetraphenylborate (TPB) (sensor 2), respectively. Furthermore, two ionophore-based sensors were prepared using β-cyclodextrin as ionophore together with TPB (sensor 3) and tetrakis(4-chlorophenyl)borate (TpClPB) (sensor 4) as ion-exchanger. Further incorporation of multi-walled carbon nanotubes (MWCNTs) between the graphite rod and the sensing membrane of sensor 4 (sensor 5) further improved the stability and significantly lowered the limit of detection (LOD). Their performance was evaluated according to IUPAC recommendations, revealing linear response in the concentration range 1 × 10−4–1 × 10−2 M, 1 × 10−5–1 × 10−2 M, 1 × 10−5–1 × 10−3 M, 1 × 10−6–1 × 10−3 M, and 1 × 10−7–1 × 10−3 M with a Nernstian slope of 54.56, 55.48, 56.00, 56.85, and 57.34 mV/decade, respectively. The LOD values for the five sensors were found to be 7.92 × 10−5, 9.98 × 10−6, 9.72 × 10−6, 9.61 × 10−7, and 9.57 × 10−8 M, respectively. The developed potentiometric sensors were successfully applied to determine the residue and degradation rate of MBC in orange samples. After the researched fungicide was applied to the orange trees, the preharvest interval (PHI) could be calculated based on the MBC degradation kinetics determined in the tested orange samples.
- 23 November 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (12) , 246
Open AccessDevelopment of All-Solid-State Potentiometric Sensors for Monitoring Carbendazim Residues in Oranges: A Degradation Kinetics Investigation
Monitoring fungicide residues in orange fruits is vital, as fungicides for orange cultivation are increasingly used to prevent yield loss. At the same time, increasing restrictions are added by regulatory organizations. For facile on-site monitoring of the fungicide carbendazim (MBC), five ion-selective potentiometric sensors are proposed and compared. The first two sensors were prepared with a precipitation-based technique using molybdate (sensor 1) and tetraphenylborate (TPB) (sensor 2), respectively. Furthermore, two ionophore-based sensors were prepared using β-cyclodextrin as ionophore together with TPB (sensor 3) and tetrakis(4-chlorophenyl)borate (TpClPB) (sensor 4) as ion-exchanger. Further incorporation of multi-walled carbon nanotubes (MWCNTs) between the graphite rod and the sensing membrane of sensor 4 (sensor 5) further improved the stability and significantly lowered the limit of detection (LOD). Their performance was evaluated according to IUPAC recommendations, revealing linear response in the concentration range 1 × 10−4–1 × 10−2 M, 1 × 10−5–1 × 10−2 M, 1 × 10−5–1 × 10−3 M, 1 × 10−6–1 × 10−3 M, and 1 × 10−7–1 × 10−3 M with a Nernstian slope of 54.56, 55.48, 56.00, 56.85, and 57.34 mV/decade, respectively. The LOD values for the five sensors were found to be 7.92 × 10−5, 9.98 × 10−6, 9.72 × 10−6, 9.61 × 10−7, and 9.57 × 10−8 M, respectively. The developed potentiometric sensors were successfully applied to determine the residue and degradation rate of MBC in orange samples. After the researched fungicide was applied to the orange trees, the preharvest interval (PHI) could be calculated based on the MBC degradation kinetics determined in the tested orange samples.
- Open Access
Established Sulfopeptide Tandem Mass Spectrometry Behavior and Sulfotransferase Assays Refute Tyrosine Sulfation as a Histone Mark
Tyrosylprotein sulfotransferases (TPST1 and TPST2) are only known to exist in the Golgi 1 . Thus, Yu et al.’s findings that histone H3 sulfation occurs in the cytosol are surprising. Cytosolic sulfotransferase SULT1B1, which sulfates phenolic small molecules, was proposed to catalyze H3Y99 sulfation with 3′-phosphoadenosine 5′-phosphosulfate (PAPS) as SO 3 donor. Bottom-up liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based proteomic analyses were key to this conclusion. Such experiments appear to have been mainly performed following standard protocols, including reduction (reagent unknown), alkylation with iodoacetamide (IAA), and proteolytic digestion prior to nanoflow LC (nanoLC) separation of proteolytic peptides and data-dependent higher energy collision dissociation (HCD) to generate sequence-informative peptide fragments. However, the published HCD MS/MS spectra do not match established sulfopeptide fragmentation behavior. We present reannotation of these spectra and additional experiments that found a lack of evidence to support H3Y99 sulfation.
Open AccessEstablished Sulfopeptide Tandem Mass Spectrometry Behavior and Sulfotransferase Assays Refute Tyrosine Sulfation as a Histone Mark
Tyrosylprotein sulfotransferases (TPST1 and TPST2) are only known to exist in the Golgi 1 . Thus, Yu et al.’s findings that histone H3 sulfation occurs in the cytosol are surprising. Cytosolic sulfotransferase SULT1B1, which sulfates phenolic small molecules, was proposed to catalyze H3Y99 sulfation with 3′-phosphoadenosine 5′-phosphosulfate (PAPS) as SO 3 donor. Bottom-up liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based proteomic analyses were key to this conclusion. Such experiments appear to have been mainly performed following standard protocols, including reduction (reagent unknown), alkylation with iodoacetamide (IAA), and proteolytic digestion prior to nanoflow LC (nanoLC) separation of proteolytic peptides and data-dependent higher energy collision dissociation (HCD) to generate sequence-informative peptide fragments. However, the published HCD MS/MS spectra do not match established sulfopeptide fragmentation behavior. We present reannotation of these spectra and additional experiments that found a lack of evidence to support H3Y99 sulfation.
- Open Access
- 30 June 2022
- Published by European Journal of Chemistry in European Journal of Chemistry
- Vol. 13 (2) , 214-223
Critical assessment of smart calculation-based spectroscopy versus chemometric-assisted methods: Application to combined antibiotic formulations
This work describes a comparative study of two multivariate chemometric and univariate spectrophotometric methods for the determination of a ternary drug mixture containing oxytetracycline HCl, bromhexine HCl, and lidocaine HCl. All methods show high sensitivity and similar linearity range. Meanwhile, the chemometric method has the advantage of higher accuracy, higher specificity and better regression parameters. The two spectrophotometric methods are constant multiplication coupled with spectrum subtraction and successive ratio subtraction coupled with spectrum subtraction while the chemometric method used partial least square and principal component regression models. In addition, a spiking technique was used to increase the concentration of bromhexine HCl in the dosage form, allowing its determination despite its low contribution. Methods were successfully applied in the dosage form Oxyclear® veterinary injection in pure powder as well as in its pharmaceutical formulation. Statistical comparison showed no significant difference between the developed methods and the reference method.
- 30 June 2022
- Published by European Journal of Chemistry in European Journal of Chemistry
- Vol. 13 (2) , 214-223
Open AccessCritical assessment of smart calculation-based spectroscopy versus chemometric-assisted methods: Application to combined antibiotic formulations
This work describes a comparative study of two multivariate chemometric and univariate spectrophotometric methods for the determination of a ternary drug mixture containing oxytetracycline HCl, bromhexine HCl, and lidocaine HCl. All methods show high sensitivity and similar linearity range. Meanwhile, the chemometric method has the advantage of higher accuracy, higher specificity and better regression parameters. The two spectrophotometric methods are constant multiplication coupled with spectrum subtraction and successive ratio subtraction coupled with spectrum subtraction while the chemometric method used partial least square and principal component regression models. In addition, a spiking technique was used to increase the concentration of bromhexine HCl in the dosage form, allowing its determination despite its low contribution. Methods were successfully applied in the dosage form Oxyclear® veterinary injection in pure powder as well as in its pharmaceutical formulation. Statistical comparison showed no significant difference between the developed methods and the reference method.
- 1 June 2022
- Published by Egyptian Knowledge Bank in Archives of Pharmaceutical Sciences Ain Shams University
- Vol. 6 (1) , 60-73
Comparison between molecularly imprinted polymers and β-cyclodextrin as ionophores, in presence of nano carbon dots water channels and application in marketed product and environmental samples
Large molecules pass the biological membranes through accessory elements, either carriers (ionophores) and/or water channels. Ionophores shield the charge of the target ion, enabling it to cross the membrane to be released on the other side. This may consume time and some huge structures need a bulky ionophore. However, water channels enable the passage of many ions with a high rate without the need of carriers that may limit the ion transfer rate. Simulation of living cell membrane in engulfing large molecules through channels is a very interesting mechanism to enhance permselectivity of fabricated polyvinyl chloride (PVC) membrane sensors. Green synthesis of carbonaceous nanoparticles to play this role was fulfilled in nano carbon dots (CD). The polymerization of β-cyclodextrin with acrylates, either imprinted with the target molecule (in molecularly imprinted polymer, MIP) or not (in non-imprinted polymer, NIP) provided a good enhancement of binding selectivity, in comparison with β-cyclodextrin alone as ionophore. Application of both inventions in fabrication of three sensors (1; CD/βCD, 2; CD/NIP and 3; CD/MIP) enabled trace analysis of azoxystrobin fungicide in ranges (10-11 -10-4, 10-13 -10-4 and 10-13 -10-4 M), respectively, with high selectivity.
- 1 June 2022
- Published by Egyptian Knowledge Bank in Archives of Pharmaceutical Sciences Ain Shams University
- Vol. 6 (1) , 60-73
Comparison between molecularly imprinted polymers and β-cyclodextrin as ionophores, in presence of nano carbon dots water channels and application in marketed product and environmental samples
Large molecules pass the biological membranes through accessory elements, either carriers (ionophores) and/or water channels. Ionophores shield the charge of the target ion, enabling it to cross the membrane to be released on the other side. This may consume time and some huge structures need a bulky ionophore. However, water channels enable the passage of many ions with a high rate without the need of carriers that may limit the ion transfer rate. Simulation of living cell membrane in engulfing large molecules through channels is a very interesting mechanism to enhance permselectivity of fabricated polyvinyl chloride (PVC) membrane sensors. Green synthesis of carbonaceous nanoparticles to play this role was fulfilled in nano carbon dots (CD). The polymerization of β-cyclodextrin with acrylates, either imprinted with the target molecule (in molecularly imprinted polymer, MIP) or not (in non-imprinted polymer, NIP) provided a good enhancement of binding selectivity, in comparison with β-cyclodextrin alone as ionophore. Application of both inventions in fabrication of three sensors (1; CD/βCD, 2; CD/NIP and 3; CD/MIP) enabled trace analysis of azoxystrobin fungicide in ranges (10-11 -10-4, 10-13 -10-4 and 10-13 -10-4 M), respectively, with high selectivity.