Lenin Vadugapalayam Rangasamy
Lenin Vadugapalayam Rangasamy has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Chinthalacheruvu Venkata Krishna Reddy
Department of Electrical and Electronics Engineering, Chaitanya Bharathi Institute of Technology, Hyderabd, India
1 shared publication - Kanthapitchai Paul Joshua
Department of Electronics and Communication Engineering, Sri Shanmugha College of Engineering and Technology, Sangagiri, Salem, India
1 shared publication M. Raja
Government College of Engineering
1 shared publicationRaja Muthu
Government College of Engineering
1 shared publication- Rajangam Veeruchinnan
Department of Mechanical Engineering, Panimalar Engineering College, Chennai, India
1 shared publication S. Sivalakshmi
Government College of Engineering
1 shared publication
Latest Publications
- 28 July 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 239 (20) , 8484-8498
System evaluation of temperature swing adsorption dryer with heat regeneration modes for air dehumidification
Moisture-free compressed air is essential in many engineering and industrial processes, and temperature swing adsorption (TSA) dryers are widely used to achieve ultra-low dew points. However, scaling TSA systems from laboratory to industrial capacities introduces challenges that numerical models alone may not fully capture, including uneven airflow and heat distribution. This study addresses these limitations by experimentally evaluating three heat regeneration modes-internal heating, external heating, and compressed air heating-at pilot-to-industrial scale. The experimental data, validated against established numerical methods, assess dryer performance across flow rates of 1000–5000 m 3 /h, pressures of 5 × 10 5 –10 × 10 5 N/m 2 , and feed air temperatures between 25°C and 45°C. The results show specific electrical energy requirements of 0.176, 0.342, and 0 kW/m 3 /min for internal, external, and compressed air heating, respectively. Compressed air heating also eliminates the need for dried regeneration air. Under typical operating conditions (35°C, 8 × 10 5 N/m 2 , 3000 m 3 /h), all three modes exhibit similar total energy and capital costs. However, compressed air heating provides the lowest operational energy demand, making it the most efficient option. This study offers practical guidance for selecting regeneration strategies and underscores the essential role of experimental methods in validating models and optimizing full-scale TSA systems.
- 28 July 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 239 (20) , 8484-8498
System evaluation of temperature swing adsorption dryer with heat regeneration modes for air dehumidification
Moisture-free compressed air is essential in many engineering and industrial processes, and temperature swing adsorption (TSA) dryers are widely used to achieve ultra-low dew points. However, scaling TSA systems from laboratory to industrial capacities introduces challenges that numerical models alone may not fully capture, including uneven airflow and heat distribution. This study addresses these limitations by experimentally evaluating three heat regeneration modes-internal heating, external heating, and compressed air heating-at pilot-to-industrial scale. The experimental data, validated against established numerical methods, assess dryer performance across flow rates of 1000–5000 m 3 /h, pressures of 5 × 10 5 –10 × 10 5 N/m 2 , and feed air temperatures between 25°C and 45°C. The results show specific electrical energy requirements of 0.176, 0.342, and 0 kW/m 3 /min for internal, external, and compressed air heating, respectively. Compressed air heating also eliminates the need for dried regeneration air. Under typical operating conditions (35°C, 8 × 10 5 N/m 2 , 3000 m 3 /h), all three modes exhibit similar total energy and capital costs. However, compressed air heating provides the lowest operational energy demand, making it the most efficient option. This study offers practical guidance for selecting regeneration strategies and underscores the essential role of experimental methods in validating models and optimizing full-scale TSA systems.
- 30 November 2023
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (3) , 3045-3059
Energy management of solar photovoltaic fed water pumping system based BLDC motor drive using NBO–SDRN approach
- 30 November 2023
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (3) , 3045-3059
Energy management of solar photovoltaic fed water pumping system based BLDC motor drive using NBO–SDRN approach
- 24 September 2020
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 47 (1) , 231-251
A study on the residential building construction information, thermal sensation and the behavior of households in Tamilnadu State – a questionnaire survey
India, our country, has five different climatic zones. The government has launched Energy Conversion and Building Codes for Residential buildings (ECBE-R) recently. National building codes are not adequate to address the climatic diversity across the country. So far, the buildings are being constructed without any recommended standards. Finding a common solution for the same over the country may not be much reliable. Also, building construction and behavior of the people are different from one part of the country to another in a diverse way like clothing insulation and food. This part of the research work aimed to find the existing building construction details, its energy consumption, overall thermal sensation, and the behavior of households in Tamilnadu through a questionnaire survey. Results indicated that most of the buildings are flat concrete roofs, walls are well constructed with redbrick with cement plaster, single floor, and age of the building is less than 20 years. The majority of the occupants stayed in the night time and they were using ceiling fans to have comfort conditioning. They also had a feeling of thermal discomfort during the summer most of the time. The source of discomfort is mainly due to building enclosures and incoming sun rays. Finally, over 70% of the occupants were willing to do minor rejuvenation in their buildings to have thermal comfort. Furthermore, this research work presents the possibility of adopting suitable cooling and ventilation techniques in order to improve air quality and also thermal comfort in existing residential buildings in hot and humid region of Tamilnadu, India.
- 24 September 2020
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 47 (1) , 231-251
A study on the residential building construction information, thermal sensation and the behavior of households in Tamilnadu State – a questionnaire survey
India, our country, has five different climatic zones. The government has launched Energy Conversion and Building Codes for Residential buildings (ECBE-R) recently. National building codes are not adequate to address the climatic diversity across the country. So far, the buildings are being constructed without any recommended standards. Finding a common solution for the same over the country may not be much reliable. Also, building construction and behavior of the people are different from one part of the country to another in a diverse way like clothing insulation and food. This part of the research work aimed to find the existing building construction details, its energy consumption, overall thermal sensation, and the behavior of households in Tamilnadu through a questionnaire survey. Results indicated that most of the buildings are flat concrete roofs, walls are well constructed with redbrick with cement plaster, single floor, and age of the building is less than 20 years. The majority of the occupants stayed in the night time and they were using ceiling fans to have comfort conditioning. They also had a feeling of thermal discomfort during the summer most of the time. The source of discomfort is mainly due to building enclosures and incoming sun rays. Finally, over 70% of the occupants were willing to do minor rejuvenation in their buildings to have thermal comfort. Furthermore, this research work presents the possibility of adopting suitable cooling and ventilation techniques in order to improve air quality and also thermal comfort in existing residential buildings in hot and humid region of Tamilnadu, India.
- 22 November 2018
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 136 (1) , 367-379
Optimization of window type and vent parameters on single-sided natural ventilation buildings
- 22 November 2018
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 136 (1) , 367-379
Optimization of window type and vent parameters on single-sided natural ventilation buildings