JBJovan Bojkovski

Jovan Bojkovski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jovan Bojkovski has a total of 117 co-authors. Here are the top co-authors by number of shared publications:

  • Janko Drnovšek

    University of Ljubljana

    6 shared publications
  • Igor Pušnik

    Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia

    3 shared publications
  • J. Drnovšek

    Metrology Institute of the Republic of Slovenia/University of Ljubljana-Faculty of Electrical Engineering/Laboratory of Metrology and Quality (MIRS/UL-FE/LMK), Ljubljana, Slovenia

    3 shared publications
  • Samo Beguš

    Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia

    3 shared publications
  • V. Batagelj

    Metrology Institute of the Republic of Slovenia/University of Ljubljana-Faculty of Electrical Engineering/Laboratory of Metrology and Quality (MIRS/UL-FE/LMK), Ljubljana, Slovenia

    3 shared publications
  • Vincencij Žužek

    Metrology Institute of the Republic of Slovenia/University of Ljubljana-Faculty of Electrical Engineering/Laboratory of Metrology and Quality (MIRS/UL-FE/LMK)

    3 shared publications

Latest Publications

  • Open Access

    Dopant-free Fabry-Pérot interferometer temperature sensors based on coreless optical fiber for high-temperature applications

    by Simon Pevec, Matej Njegovec, Vedran Budinski, René Eisermann, Stephan Krenek, Jovan Bojkovski, Vincencij Žužek, Denis Đonlagić

  • Open Access

    Development and Validation of an Argon Triple Point Apparatus with a Novel Automatic Pressure Control System

    by Ivan Matas, Lovorka Grgec Bermanec, Danijel Šestan, Jovan Bojkovski, Vincencij Žužek

    This paper describes the development and validation of an apparatus for the realization of the triple point of argon (83.8058 K), with a novel automatic pressure control system for the liquid nitrogen cryostat. The automatic pressure controller, together with custom-made software, was developed and tested in the Laboratory for Process Measurement at the Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb (FSB-LPM). Performance testing and characterization of the automatic pressure controller confirmed its suitability for precise and reliable control of gauge pressure in the cryostat. The characteristics and uncertainty of the measurement setup for the realization of the triple point of argon were validated through a bilateral hybrid comparison with the Laboratory of Metrology and Quality at the Faculty of Electrical Engineering, University of Ljubljana (MIRS/UL-FE/LMK). A long-stem quartz-sheathed standard platinum resistance thermometer was used as a transfer standard. The realizations of the International Temperature Scale (ITS-90) were compared in the subrange from the triple point of argon to the triple point of water. The comparison results show that resistance ratio (W) values determined by FSB-LPM at the fixed points of argon and mercury deviate from the MIRS/UL-FE/LMK values, within the determined combined uncertainty of the comparison.

  • EURAMET.T-K9 regional key comparison ITS-90 SPRT calibration from the Ar TP to the Zn FP

    by Fernando Sparasci, Lara Risegari, Catherine Martin, Yves Hermier, Giuseppina Lopardo, Petrus Paulus Maria Steur, Jonathan Pearce, Lars Bünger, Steffen Rudtsch, Conny de Bruin-Barendregt, et al.

    Main text: This is a report to the Technical Committee for Thermometry of EURAMET (EURAMET TC-T) on the regional key comparison EURAMET.T-K9 of SPRT calibration on the International Temperature Scale of 1990 (ITS-90), from 83.8058 K (the Ar triple point) to 692.677 K (the Zn fixed point). The transfer standards used are long-stem SPRTs. EURAMET.T-K9 is an RMO key comparison linked to the CIPM key comparison CCT-K9. The comparison is organized in five separate collapsed Stars, each one having a CCT-K9 participant as pilot, which provides the link to the KCRV of CCT-K9. Four to five participating laboratories are involved in each Star. The pilots of the five Stars are LNE-Cnam, PTB, INRiM, VSL, NPL. LNE-Cnam is also the coordinator of the comparison, in charge of the collection of the measurement reports from all participants and the preparation of the final report. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • Open Access

    Sound-card-based Johnson noise thermometer

    by Rok Tavčar, Jovan Bojkovski, Samo Beguš


  • Open Access

    Model for Quantitative Estimation of Functionality Influence on the Final Value of a Software Product

    by Gregor Molan, Gregor Dolinar, Jovan Bojkovski, Radu Prodan, Andrea Borghesi, Martin Molan

    Purpose: The gap between software development requirements and the available resources of software developers continues to widen. This requires changes in the development and organization of software development. Objectives: Presented is a model introducing a quantitative software development management methodology that estimates the relative importance and risk of functionality retention or abundance, which determines the final value of the software product. Method: The final value of the software product is interpreted as a function of the requirements and functionalities, represented as a computational graph (called a software product graph). The software product graph allows the relative importance of functionalities to be estimated by calculating the corresponding partial derivatives of the value function. The risk of not implementing the functionality is estimated by reducing the final value of a product. Validation: This model has been applied to two EU projects: CareHD and vINCI. In vINCI, the functionalities with the most significant added value to the application were developed based on the implemented model and those that brought the least value were abandoned. Optimization was not implemented in the CareHD project and proceeded as initially designed. Consequently, only 71% of the CareHD’s potential value has been realized. Conclusions: Presented model enables rational management and organization of software product development with real-time quantitative evaluation of functionalities impacts, assessment of the risks of omitting them without a significant impact. A quantitative evaluation of the impacts and risks of retention or abundance is possible based on the proposed algorithm, which is the core of the model. This model is a tool for rational organization and development of software products.

  • An Improved Design of Synthetic Loading Method for a Rapid In-Wheel Motor Characterization in Different Operating Points

    by Jernej Herman, Jovan Bojkovski, Rastko Fiser, Klemen Drobnic

    In-wheel motors (IWMs) as a crucial component of an electric vehicle need to be tested at the end of the production line, at service intervals, and during motor design validation. This article presents an improved synthetic loading (SL) method for the rapid characterization of the IWMs. The proposed method emulates mechanical loading at a specific operating point by current harmonic injection. We introduce a novel algorithm for the current reference setting that is based on the manufacturer’s motor design data and accounts for the motor’s nonlinearities. Also, the method features a trapezoidal reference instead of a sinusoidal, which lowers the instantaneous peak current of the converter and, thereby, increases the attainable torque–speed range. The performance of the proposed SL method is comparable to the classic back-to-back (BB) testing method, which is confirmed by the theoretical analysis, simulations, and experimental results. The difference in motor efficiency measured with the BB and the improved SL method is smaller than 1% in most operating points. The proposed method offers considerable time and cost savings for the manufacturer—eliminating the mechanical coupling/decoupling operation—and can be applied to surface-mounted permanent magnet synchronous machines in general.


  • Open Access

    Optimization of a Single Tube Practical Acoustic Thermometer

    by Rok Tavčar, Janko Drnovšek, Jovan Bojkovski, Samo Beguš

    When designing a single tube practical acoustic thermometer (PAT), certain considerations should be addressed for optimal performance. This paper is concerned with the main issues involved in building a reliable PAT. It has to be emphasised that a PAT measures the ratio of the time delay between the single temperature calibration point (ice point) and any other temperature. Here, we present different models of the speed of sound in tubes, including the effects of real gases and an error analysis of the most accurate model with a Monte Carlo simulation. Additionally, we introduce the problem of acoustic signal overlap and some possible solutions, one of which is acoustic signal cancellation, which aims to eliminate the unwanted parts of an acoustic signal, and another is to optimize the tube length for the parameters of the gas used and specific temperature range.


  • Novel Method for Direct Measurement of Air Gap Anomalies in Direct-Drive Electrical Motors

    by Jernej Herman, Samo Begus, Polona Mihalic, Jovan Bojkovski

    The paper presents a novel measuring system for detecting air gap anomalies in direct-drive electrical motors. The air gap anomalies can be of different types of eccentricity which may in extreme cases result in a mechanical rub between the stator and rotor, potentially leading to a motor breakdown. A novel measuring method is proposed using a sensory system integrated in a motor air gap to measure its width directly either in a static or dynamic state. It uses an optical sensory system to measure reflection of the infrared radiation between the rotor and stator. The method is validated by using a parallel measuring system employing an analogue Hall sensory system that measures the change in the magnetic-flux density. The two measuring systems are calibrated by comparing them to a reference laboratory measuring system consisting of a camera and lenses. The calibration is performed in a laboratory in a motor static state within one mechanical rotation cycle of the rotor. Using different calibration techniques, the optimal system accuracy, with a maximum permissible error of 0.15 mm is obtained, in the measuring range between 0 mm and 2 mm. It covers most applications of the direct-drive electrical motors. The new measuring method is validated by using an experimental set-up consisting of the presented optical sensory system and validation system an analogue Hall integrated on a testing platform (Smart Fortwo car).


  • WMO Interlaboratory Comparison in Europe with Loops Linkage and Data Processing

    by Jovan Bojkovski, Janko Drnovšek, Drago Groselj, Joško Knez, Gaber Begeš

    This article describes the interlaboratory comparison (ILC) of meteorological and hydrological calibration laboratories in the field of temperature (−30° to 40°C), humidity (10%–95% RH at room temperature), and pressure (800–1100 hPa). The ILC was organized by the World Meteorological Organization (WMO) Regional Instrument Centre (RIC) at the Slovenian Environment Agency and University of Ljubljana, Faculty of Electrical Engineering, Laboratory of Metrology and Quality as an accredited interlaboratory comparison (proficiency testing) provider according to the ISO/IEC 17043:2010 standard. The ILC was organized in the target area of WMO Regional Association VI (Europe). The protocol and procedure for ILC were developed within European Metrology Research Project (EMRP) MetoMet2. The participants used their standardized procedures for calibration. Because of the large number of participating laboratories (18) from 17 countries, the ILC was organized in two loops, which were linked via four linking laboratories and evaluated using the En number. The equipment used in both loops exhibited stability and uncertainty, which enabled evaluation of the laboratories’ capabilities. The article presents the data processing, the linkage procedure, and the main results for all three categories (temperature, humidity, and pressure). It was observed that some of the laboratories had unusually low uncertainties. From the metrological point of view, the authors present some comments and suggestions to the laboratories, the results of which differ from the reference ones. The conclusions can help also other meteorological laboratories and organizations that did not participate in the ILC with their everyday work.