Maik Eichelbaum
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Maik Eichelbaum has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
Robert Schlögl
Department of Inorganic Chemistry, Fritz-Haber-Institut der Max-Planck-Gesellschaft, 14195 Berlin, Germany
10 shared publicationsChristian Heine
Department of Inorganic Chemistry, Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, 14195 Berlin, Germany.
8 shared publicationsAnnette Trunschke
Department of Inorganic Chemistry, Fritz-Haber-Institut der Max-Planck-Gesellschaft, 14195 Berlin, Germany
7 shared publications- Klaus Rademann
ZEITSCHRIFT FÜR PHYSIKALISCHE CHEMIE INTERNATIONAL JOURNAL
6 shared publications Michael Hävecker
Department of Inorganic Chemistry
6 shared publicationsFrank Rosowski
BasCat, UniCat BASF JointLab, TU Berlin, Marchstraße 6, 10587 Berlin (Deutschland)
5 shared publications
Latest Publications
- Open Access
- 9 September 2026
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 6 (5) , 1809-1824
Electrical Impedance Tomography for Spatial Conductivity Mapping of PEM Fuel Cell Components
Electrical impedance tomography (EIT) was assessed as a measurement approach for spatial conductivity mapping of electrochemical energy system materials such as polymer electrolyte membrane fuel cell components. Polymer electrolyte membranes were selectively activated or deactivated, and defined artificial defects were introduced into catalyst-coated membranes (CCMs) and gas diffusion layers to evaluate the sensitivity and diagnostic capability of EIT. Reconstructed conductivity distributions were independently verified using scanning electrochemical microscopy to confirm spatial contrast and reconstruction accuracy. EIT enabled rapid, nondestructive detection of large-area variations in activation state and degradation. Localized defects were reliably detected, with the methodology prioritizing spatial localization and fault identification providing a distinct advantage over electrical impedance spectroscopy, which lacks the spatial context to distinguish between localized and global degradation. Reproducibility studies on CCMs showed that measurement variability and sample remounting effects remained sufficiently low for consistent defect identification, with defect and background signals clearly separated for different confidence intervals. Simulation studies with different electrode counts and positions, defect arrangements, and sample sizes including a realistic fuel cell application-scale CCM sample were performed as a qualitative design illustration for possible future EIT applications. This development constitutes an important methodological step toward fast nondestructive electrochemical imaging of fuel cell materials and may provide a powerful tool for in-line, in situ, and operando investigations of localized activation, degradation, defects, and heterogeneities in electrochemical energy devices.
- 9 September 2026
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 6 (5) , 1809-1824
Open AccessElectrical Impedance Tomography for Spatial Conductivity Mapping of PEM Fuel Cell Components
Electrical impedance tomography (EIT) was assessed as a measurement approach for spatial conductivity mapping of electrochemical energy system materials such as polymer electrolyte membrane fuel cell components. Polymer electrolyte membranes were selectively activated or deactivated, and defined artificial defects were introduced into catalyst-coated membranes (CCMs) and gas diffusion layers to evaluate the sensitivity and diagnostic capability of EIT. Reconstructed conductivity distributions were independently verified using scanning electrochemical microscopy to confirm spatial contrast and reconstruction accuracy. EIT enabled rapid, nondestructive detection of large-area variations in activation state and degradation. Localized defects were reliably detected, with the methodology prioritizing spatial localization and fault identification providing a distinct advantage over electrical impedance spectroscopy, which lacks the spatial context to distinguish between localized and global degradation. Reproducibility studies on CCMs showed that measurement variability and sample remounting effects remained sufficiently low for consistent defect identification, with defect and background signals clearly separated for different confidence intervals. Simulation studies with different electrode counts and positions, defect arrangements, and sample sizes including a realistic fuel cell application-scale CCM sample were performed as a qualitative design illustration for possible future EIT applications. This development constitutes an important methodological step toward fast nondestructive electrochemical imaging of fuel cell materials and may provide a powerful tool for in-line, in situ, and operando investigations of localized activation, degradation, defects, and heterogeneities in electrochemical energy devices.
- Open Access
- 21 May 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 684
Prediction of MEA degradation in fuel cells for heavy-duty vehicle applications based on driving cycle analysis and component-specific accelerated stress testing
- 21 May 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 684
Open AccessPrediction of MEA degradation in fuel cells for heavy-duty vehicle applications based on driving cycle analysis and component-specific accelerated stress testing
- Open Access
- 29 October 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Fuel Cell Degradation Prediction for Heavy-Duty Vehicle Applications Based on Driving Cycle Analysis and Component-Specific Accelerated Stress Testing
To enable the long-term deployment of polymer electrolyte membrane fuel cells (PEMFCs) in heavy-duty vehicle applications, a deep understanding of degradation mechanisms under realistic operating conditions is essential. Especially in this sector, fuel cell systems must withstand high loads, fluctuating environmental conditions, and long operating hours, placing high demands on material durability and system design. In this study, a commercial single-cell MEA, which was specifically designed for usage in heavy-duty applications, was subjected to two distinct accelerated stress test (AST) protocols: the All Component Aging Test (ACAT) and the Truck Driving Cycle Test (TDCT). The ACAT is based on a synthetic voltage profile with broad variations in temperature and humidity, while the TDCT reflects real-world driving data and includes moderate environmental conditions but applies elevated and differential pressure. Additionally, standardized Department of Energy (DoE) component-specific aging tests were performed for comparison. The two ASTs revealed clear component-specific limitations: catalyst layer degradation dominated in ACAT, indicated by a significant platinum electrochemically active surface area loss and voltage drop, whereas membrane degradation was dominant in TDCT, as evidenced by an early increase in hydrogen crossover current. As for the DoE tests, the investigated MEA met most of the defined stability criteria. Hence, these standardized tests alone did not reveal which components are most prone to aging under realistic conditions. The findings demonstrate that generic, standardized test procedures are of limited use when it comes to estimating the real-world durability of fuel cells in heavy-duty applications. To obtain meaningful predictions and understand critical degradation mechanisms, AST protocols are additionally required to reflect the specific operating conditions of the intended application.
- 29 October 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessFuel Cell Degradation Prediction for Heavy-Duty Vehicle Applications Based on Driving Cycle Analysis and Component-Specific Accelerated Stress Testing
To enable the long-term deployment of polymer electrolyte membrane fuel cells (PEMFCs) in heavy-duty vehicle applications, a deep understanding of degradation mechanisms under realistic operating conditions is essential. Especially in this sector, fuel cell systems must withstand high loads, fluctuating environmental conditions, and long operating hours, placing high demands on material durability and system design. In this study, a commercial single-cell MEA, which was specifically designed for usage in heavy-duty applications, was subjected to two distinct accelerated stress test (AST) protocols: the All Component Aging Test (ACAT) and the Truck Driving Cycle Test (TDCT). The ACAT is based on a synthetic voltage profile with broad variations in temperature and humidity, while the TDCT reflects real-world driving data and includes moderate environmental conditions but applies elevated and differential pressure. Additionally, standardized Department of Energy (DoE) component-specific aging tests were performed for comparison. The two ASTs revealed clear component-specific limitations: catalyst layer degradation dominated in ACAT, indicated by a significant platinum electrochemically active surface area loss and voltage drop, whereas membrane degradation was dominant in TDCT, as evidenced by an early increase in hydrogen crossover current. As for the DoE tests, the investigated MEA met most of the defined stability criteria. Hence, these standardized tests alone did not reveal which components are most prone to aging under realistic conditions. The findings demonstrate that generic, standardized test procedures are of limited use when it comes to estimating the real-world durability of fuel cells in heavy-duty applications. To obtain meaningful predictions and understand critical degradation mechanisms, AST protocols are additionally required to reflect the specific operating conditions of the intended application.
- Open Access
- 12 August 2025
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 5 (5) , 740-750
Spatially Resolved Differentiation of Functional Degradation and Perforating Structural Defects in Membrane Electrode Assemblies Using Diffusion-Cell Coupled DC-SECM
In order to increase the lifetime of polymer electrolyte membrane (PEM) fuel cells (PEMFCs) and water electrolyzers (PEMWEs), understanding local degeneration processes in membrane electrode assemblies (MEAs) is crucial. By a combination of scanning electrochemical microscopy (SECM) with a flow-through diffusion cell (DiffC-DC-SECM) and ferrocyanide and protons as redox mediators, a spatially resolved analytical method was developed that can differentiate between different functional and structural degeneration phenomena in the aging process of a membrane. An SECM scan at cathodic potential detects the diffusion of protons through the membrane and thus its through-plane proton conductivity, while a second SECM scan at anodic potential visualizes the diffusion of the iron complex through the membrane, thus perforating structural damage such as cracks and holes. The method was successfully validated for the spatially resolved differentiation of membrane damage in pristine PEMs and catalyst-coated membranes (CCMs) with artificial holes, chemically aged CCMs, and MEAs in fully assembled operational PEMFCs aged by an open-circuit voltage membrane accelerated stress test. DiffC-DC-SECM thus provides a powerful technique with high local resolution for membrane integrity testing under realistic operation conditions to develop long-term durable materials for PEMFCs and PEMWEs.
- 12 August 2025
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 5 (5) , 740-750
Open AccessSpatially Resolved Differentiation of Functional Degradation and Perforating Structural Defects in Membrane Electrode Assemblies Using Diffusion-Cell Coupled DC-SECM
In order to increase the lifetime of polymer electrolyte membrane (PEM) fuel cells (PEMFCs) and water electrolyzers (PEMWEs), understanding local degeneration processes in membrane electrode assemblies (MEAs) is crucial. By a combination of scanning electrochemical microscopy (SECM) with a flow-through diffusion cell (DiffC-DC-SECM) and ferrocyanide and protons as redox mediators, a spatially resolved analytical method was developed that can differentiate between different functional and structural degeneration phenomena in the aging process of a membrane. An SECM scan at cathodic potential detects the diffusion of protons through the membrane and thus its through-plane proton conductivity, while a second SECM scan at anodic potential visualizes the diffusion of the iron complex through the membrane, thus perforating structural damage such as cracks and holes. The method was successfully validated for the spatially resolved differentiation of membrane damage in pristine PEMs and catalyst-coated membranes (CCMs) with artificial holes, chemically aged CCMs, and MEAs in fully assembled operational PEMFCs aged by an open-circuit voltage membrane accelerated stress test. DiffC-DC-SECM thus provides a powerful technique with high local resolution for membrane integrity testing under realistic operation conditions to develop long-term durable materials for PEMFCs and PEMWEs.
- Open Access
- 16 June 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Spatially Resolved Differentiation of Functional Degradation and Perforating Structural Defects in Membrane Electrode Assemblies Using Diffusion-Cell Coupled DC-SECM
In order to increase the lifetime of polymer electrolyte membrane (PEM) fuel cells (PEMFCs) and water electrolyzers (PEMWEs), the understanding of local degeneration processes in membrane electrode assemblies (MEAs) is crucial. By combining scanning electrochemical microscopy (SECM) with a flow-through diffusion cell (DiffC-DC-SECM) and ferrocyanide and protons as redox mediators, a spatially resolved analytical method was developed that can differentiate between different functional and structural degeneration phenomena in the aging process of a membrane. An SECM scan at cathodic potential detects the diffusion of protons through the membrane and thus its through-plane proton conductivity, while a second SECM scan at anodic potential visualizes the diffusion of the iron complex through the membrane and thus perforating structural damage such as cracks and holes. The method was successfully validated for the spatially resolved differentiation of membrane damage in pristine PEMs and catalyst-coated membranes (CCMs) with artificial holes, chemically aged CCMs and of MEAs in fully assembled operational PEMFCs aged by an open-circuit voltage membrane accelerated stress test. DiffC-DC-SECM thus provides a powerful technique with high local resolution for membrane integrity testing under realistic operation conditions to develop long-term durable materials for PEMFCs and PEMWEs.
- 16 June 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessSpatially Resolved Differentiation of Functional Degradation and Perforating Structural Defects in Membrane Electrode Assemblies Using Diffusion-Cell Coupled DC-SECM
In order to increase the lifetime of polymer electrolyte membrane (PEM) fuel cells (PEMFCs) and water electrolyzers (PEMWEs), the understanding of local degeneration processes in membrane electrode assemblies (MEAs) is crucial. By combining scanning electrochemical microscopy (SECM) with a flow-through diffusion cell (DiffC-DC-SECM) and ferrocyanide and protons as redox mediators, a spatially resolved analytical method was developed that can differentiate between different functional and structural degeneration phenomena in the aging process of a membrane. An SECM scan at cathodic potential detects the diffusion of protons through the membrane and thus its through-plane proton conductivity, while a second SECM scan at anodic potential visualizes the diffusion of the iron complex through the membrane and thus perforating structural damage such as cracks and holes. The method was successfully validated for the spatially resolved differentiation of membrane damage in pristine PEMs and catalyst-coated membranes (CCMs) with artificial holes, chemically aged CCMs and of MEAs in fully assembled operational PEMFCs aged by an open-circuit voltage membrane accelerated stress test. DiffC-DC-SECM thus provides a powerful technique with high local resolution for membrane integrity testing under realistic operation conditions to develop long-term durable materials for PEMFCs and PEMWEs.
- 3 July 2024
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 128 (28) , 11845-11857
Charge Carrier Dynamics in Undoped and N-Doped Titania Nanolayers upon Ultraviolet and Visible Light Irradiation
- 3 July 2024
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 128 (28) , 11845-11857
Charge Carrier Dynamics in Undoped and N-Doped Titania Nanolayers upon Ultraviolet and Visible Light Irradiation
- Open Access
- 25 April 2024
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 14 (20) , 13748-13757
Scanning electrochemical microscopy for the differentiation of radical-induced degradation mechanisms in polymer electrolyte membranes
In this work, a spatially resolved analytical method based on scanning electrochemical microscopy (SECM) to distinguish different degradation phenomena in polymer electrolyte membranes was developed.
- 25 April 2024
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 14 (20) , 13748-13757
Open AccessScanning electrochemical microscopy for the differentiation of radical-induced degradation mechanisms in polymer electrolyte membranes
In this work, a spatially resolved analytical method based on scanning electrochemical microscopy (SECM) to distinguish different degradation phenomena in polymer electrolyte membranes was developed.
- Open Access
- 18 February 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-22
Dynamic accelerated stress test and coupled on-line analysis program to elucidate aging processes in proton exchange membrane fuel cells
The application of hydrogen proton exchange membrane fuel cells (PEMFC) in greenhouse gas emission free heavy-duty vehicles requires extremely durable PEMFC components with service lives in the range of 30,000 h. Hence suitable test and analysis methods are required that reflect realistic operation scenarios, but significantly accelerate aging. For this purpose, a dynamic accelerated stress test was developed, which is coupled with a comprehensive in-depth in-situ and ex-situ analysis program to determine the aging processes of a PEMFC membrane electrode assembly (MEA). The test comprehends dynamic cycling between low, moderate and high load, different temperature and humidity conditions as well as recovery sequences to distinguish between reversible and irreversible failure modes. All phases of the PEMFC system (i.e. solid, liquid and gaseous) are monitored on-line during aging by sophisticated electrochemical, mass spectrometric and ion chromatographic analytical methods. The structural and elemental composition of the MEA before and after the aging program (post-mortem) are investigated by X-ray fluorescence, scanning and transmission electron microscopy. This program was able to age a commercial PEMFC to end-of-life in 1000 h, while providing an accurate picture of the aging processes involved.
- 18 February 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-22
Open AccessDynamic accelerated stress test and coupled on-line analysis program to elucidate aging processes in proton exchange membrane fuel cells
The application of hydrogen proton exchange membrane fuel cells (PEMFC) in greenhouse gas emission free heavy-duty vehicles requires extremely durable PEMFC components with service lives in the range of 30,000 h. Hence suitable test and analysis methods are required that reflect realistic operation scenarios, but significantly accelerate aging. For this purpose, a dynamic accelerated stress test was developed, which is coupled with a comprehensive in-depth in-situ and ex-situ analysis program to determine the aging processes of a PEMFC membrane electrode assembly (MEA). The test comprehends dynamic cycling between low, moderate and high load, different temperature and humidity conditions as well as recovery sequences to distinguish between reversible and irreversible failure modes. All phases of the PEMFC system (i.e. solid, liquid and gaseous) are monitored on-line during aging by sophisticated electrochemical, mass spectrometric and ion chromatographic analytical methods. The structural and elemental composition of the MEA before and after the aging program (post-mortem) are investigated by X-ray fluorescence, scanning and transmission electron microscopy. This program was able to age a commercial PEMFC to end-of-life in 1000 h, while providing an accurate picture of the aging processes involved.
- Open Access
- 28 November 2023
- Published by Springer Nature in Research Square
Dynamic accelerated stress test and coupled on-line analysis program to elucidate aging processes in proton exchange membrane fuel cells
The application of hydrogen proton exchange membrane fuel cells (PEMFC) in greenhouse gas emission free heavy-duty vehicles requires extremely durable PEMFC components with service lives in the range of 30,000 hours. Hence suitable test and analysis methods are required that reflect realistic operation scenarios, but significantly accelerate aging. For this purpose, a dynamic accelerated stress test (AST) was developed, which is coupled with a comprehensive in-depth in-situ and ex-situ analysis program to determine the aging processes of a PEMFC membrane electrode assembly (MEA). The test comprehends dynamic cycling between low, moderate and high load, different temperature and humidity conditions as well as recovery sequences to distinguish between reversible and irreversible failure modes. All phases of the PEMFC system (i.e.solid, liquid and gaseous) are monitored on-line during aging by sophisticated electrochemical, mass spectrometric and ion chromatographic analytical methods. The structural and elemental composition of the MEA before and after the aging program (post-mortem) are investigated by X-ray fluorescence, scanning and transmission electron microscopy. This program was able to age a commercial PEMFC to end-of-life in 1,000 hours, while providing an accurate picture of the aging processes involved.
- 28 November 2023
- Published by Springer Nature in Research Square
Open AccessDynamic accelerated stress test and coupled on-line analysis program to elucidate aging processes in proton exchange membrane fuel cells
The application of hydrogen proton exchange membrane fuel cells (PEMFC) in greenhouse gas emission free heavy-duty vehicles requires extremely durable PEMFC components with service lives in the range of 30,000 hours. Hence suitable test and analysis methods are required that reflect realistic operation scenarios, but significantly accelerate aging. For this purpose, a dynamic accelerated stress test (AST) was developed, which is coupled with a comprehensive in-depth in-situ and ex-situ analysis program to determine the aging processes of a PEMFC membrane electrode assembly (MEA). The test comprehends dynamic cycling between low, moderate and high load, different temperature and humidity conditions as well as recovery sequences to distinguish between reversible and irreversible failure modes. All phases of the PEMFC system (i.e.solid, liquid and gaseous) are monitored on-line during aging by sophisticated electrochemical, mass spectrometric and ion chromatographic analytical methods. The structural and elemental composition of the MEA before and after the aging program (post-mortem) are investigated by X-ray fluorescence, scanning and transmission electron microscopy. This program was able to age a commercial PEMFC to end-of-life in 1,000 hours, while providing an accurate picture of the aging processes involved.
- Open Access
- 7 November 2022
- Published by MDPI AG in Electrochem
- Vol. 3 (4) , 728-745
Validation of Voltammetric Methods for Online Analysis of Platinum Dissolution in a Hydrogen PEM Fuel Cell Stack
Platinum dissolution in PEM fuel cells is an increasingly important indicator for the state-of-health and lifetime prediction of fuel cells in real applications. For this reason, portable online analysis tools are needed that can detect and quantify platinum with high sensitivity, selectivity, and accuracy in the product water of fuel cells. We validated the hanging mercury drop electrode (HMDE) and non-toxic bismuth film electrodes for the voltammetric determination of platinum for this purpose. Bismuth films were prepared by reductive deposition on both a glassy carbon solid state electrode and on a screen-printed electrode (film on-chip electrode). Both bismuth film electrodes could be successfully validated for the determination of platinum by adsorptive stripping voltammetry. An LOD of 7.9 μg/L and an LOQ of 29.1 μg/L were determined for the bismuth film solid state electrode, values of 22.5 μg/L for the LOD and of 79.0 μg/L for the LOQ were obtained for the bismuth film on-chip electrode. These numbers are still much higher than the results measured with the HMDE (LOD: 0.76 ng/L; LOQ: 2.8 ng/L) and are not sufficient to detect platinum in the product water of a fuel cell run in different load tests. The amount of dissolved platinum produced by a 100 W fuel cell stack upon dynamic and continuous high load cycling, respectively, was in the range of 2.9–4.1 ng/L, which could only be detected by the HMDE.
- 7 November 2022
- Published by MDPI AG in Electrochem
- Vol. 3 (4) , 728-745
Open AccessValidation of Voltammetric Methods for Online Analysis of Platinum Dissolution in a Hydrogen PEM Fuel Cell Stack
Platinum dissolution in PEM fuel cells is an increasingly important indicator for the state-of-health and lifetime prediction of fuel cells in real applications. For this reason, portable online analysis tools are needed that can detect and quantify platinum with high sensitivity, selectivity, and accuracy in the product water of fuel cells. We validated the hanging mercury drop electrode (HMDE) and non-toxic bismuth film electrodes for the voltammetric determination of platinum for this purpose. Bismuth films were prepared by reductive deposition on both a glassy carbon solid state electrode and on a screen-printed electrode (film on-chip electrode). Both bismuth film electrodes could be successfully validated for the determination of platinum by adsorptive stripping voltammetry. An LOD of 7.9 μg/L and an LOQ of 29.1 μg/L were determined for the bismuth film solid state electrode, values of 22.5 μg/L for the LOD and of 79.0 μg/L for the LOQ were obtained for the bismuth film on-chip electrode. These numbers are still much higher than the results measured with the HMDE (LOD: 0.76 ng/L; LOQ: 2.8 ng/L) and are not sufficient to detect platinum in the product water of a fuel cell run in different load tests. The amount of dissolved platinum produced by a 100 W fuel cell stack upon dynamic and continuous high load cycling, respectively, was in the range of 2.9–4.1 ng/L, which could only be detected by the HMDE.