KLKyeoReh Lee

KyeoReh Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


KyeoReh Lee has a total of 96 co-authors. Here are the top co-authors by number of shared publications:

  • YongKeun Park

    Department of Physics Korea Advanced Institute of Science and Technology (KAIST) Daejeon Republic of Korea

    42 shared publications
  • Kyoohyun Kim

    Department of Physics, Korea Advanced Institutes of Science and Technology, Daejeon 34141, South Korea

    10 shared publications
  • Seungwoo Shin

    Department of Physics, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, South Korea

    7 shared publications
  • Jongchan Park

    Department of Physics, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea

    6 shared publications
  • YongKeun Park

    Department of Physics, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea

    6 shared publications
  • YoonSeok Baek

    Department of Physics, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, South Korea

    6 shared publications

Latest Publications

  • Open Access

    Tailored speckle illumination microscopy with enhanced sectioning and image quality

    by SeungYun Han, KyeoReh Lee, Young Seo Kim, Chuan Li, Nicholas Bender, Kabish Wisal, Taeyun Ku, Jerome Mertz, Hui Cao

    Optical speckle patterns have been widely used for illumination in computational imaging, optical sectioning microscopy, and superresolution imaging. However, commonly used speckles satisfy Rayleigh statistics, which are not ideal for diverse imaging applications. Here we tailor three-dimensional speckle intensity statistics for dynamic speckle illumination microscopy based on linear fluorescence. Optical sectioning is enhanced by axially varying speckle contrast, and image reconstruction noise is minimized with in-focus speckles of binary intensities. The customized speckle statistics are shown to tolerate sample-induced aberration and scattering. We apply tailored speckle illumination to mouse brain vascular imaging and demonstrate much improved image quality than optical-sectioning structured illumination. These results establish customization of speckle intensity statistics as a promising strategy for robust, high-throughput fluorescence imaging in thick, scattering biological specimens.

  • Wavefront shaping enables high-power multimode fiber amplifier with output focus

    by Stefan Rothe, Chun-Wei Chen, Peyman Ahmadi, KyeoReh Lee, Kabish Wisal, Mert Ercan, Nathan Vigne, A. Douglas Stone, Hui Cao

    High-power fiber lasers are powerful tools used in science, industry, and defense. A major roadblock for further power scaling of single-frequency fiber laser amplifiers is stimulated Brillouin scattering. Efforts have been made to mitigate this nonlinear process, but these were mostly limited to single-mode or few-mode fiber amplifiers, which have good beam quality. Here, we explored a highly multimode fiber amplifier in which stimulated Brillouin scattering was greatly suppressed due to a reduction of light intensity in a large fiber core and a broadening of the Brillouin scattering spectrum by multimode excitation. By applying a spatial wavefront shaping technique to the input light of a nonlinear amplifier, the output beam was focused to a diffraction-limited spot. Our multimode fiber amplifier can operate at high power with high efficiency and narrow linewidth, which ensures high coherence. Optical wavefront shaping enables coherent control of multimode laser amplification, with potential applications in coherent beam combining, large-scale interferometry and directed energy delivery.


  • Open Access

    Direct high-resolution X-ray imaging exploiting pseudorandomness

    by KyeoReh Lee, Jun Lim, Su Yong Lee, YongKeun Park

    Owing to its unique penetrating power and high-resolution capability, X-ray imaging has been an irreplaceable tool since its discovery. Despite the significance, the resolution of X-ray imaging has largely been limited by the technical difficulties on X-ray lens making. Various lensless imaging methods have been proposed, but are yet relying on multiple measurements or additional constraints on measurements or samples. Here we present coherent speckle-correlation imaging (CSI) using a designed X-ray diffuser. CSI has no prerequisites for samples or measurements. Instead, from a single shot measurement, the complex sample field is retrieved based on the pseudorandomness of the speckle intensity pattern, ensured through a diffuser. We achieve a spatial resolution of 13.9 nm at 5.46 keV, beating the feature size of the diffuser used (300 nm). The high-resolution imaging capability is theoretically explained based on fundamental and practical limits. We expect the CSI to be a versatile tool for navigating the unexplored world of nanometer.


  • Full-field quantitative X-ray phase nanotomography via space-domain Kramers–Kronig relations

    by KyeoReh Lee, Jun Lim, YongKeun Park

    Given the low absorption contrast of X-rays, phase shift has been playing an important role as an alternative source of contrast in X-ray nanoimaging. Numerous phase-measuring techniques have been proposed, most of which, however, are based on significant assumptions or sample translations. In this study, we propose the application of Kramers–Kronig (KK) relations in the spatial domain as a solution to allow the X-ray quantitative phase image to be directly calculated from the measured intensity image without any additional requirements. Based on this straightforward principle, we have presented KK nanotomography by introducing a spatial-frequency cutoff filter into a conventional tomographic setup. The robustness and versatility of the proposed method were experimentally verified based on various sample tomograms. We expect KK nanotomography to be widely adopted as a powerful and easy-to-adapt phase quantification solution for X-ray microscopes.


  • Pulse-to-pulse field characterization at x-ray free-electron lasers using a speckle-correlation scattering matrix

    by KyeoReh Lee, Jun Lim, YongKeun Park

    In coherent diffraction experiments, knowledge of the incident field is important to extract pure sample-induced data from measured diffraction patterns. However, this becomes challenging in x-ray free-electron lasers (XFELs), as incident fields vary from pulse to pulse due to the stochastic nature of self-amplified stimulated emission. Despite various proposed field retrieval methods, single-shot characterization of each pulse remains elusive. To address this, we propose the speckle-correlation scattering matrix as a solution. Our method directly reconstructs the complex field without sample constraints or multiple acquisitions by introducing a designed diffuser before the detector. We demonstrate the robustness of our approach through successful field reconstructions in various experimental configurations. Based on the retrieved field results, pulse-to-pulse variations in pulse intensity, position, illumination angle, and shape were analyzed. We believe our method can readily serve as an on-field and real-time pulse diagnostic tool at XFELs and improve the overall quality of all experiments performed at XFELs.


  • Non-resonant lasing in a deep-hole scattering cavity

    by ChulMin Oh, Ho Jin Ma, KyeoReh Lee, Do Kyung Kim, YongKeun Park

    Random lasers are promising in the spectral regime, wherein conventional lasers are unavailable, with advantages of low fabrication costs and applicability of diverse gain materials. However, their practical application is hindered by high threshold powers, low power efficiency, and difficulties in light collection. Here, we demonstrate a power-efficient easy-to-fabricate non-resonant laser using a deep hole on a porous gain material. The laser action in this counterintuitive cavity was enabled by non-resonant feedback from strong diffuse reflections on the inner surface. Additionally, significant enhancements in slope efficiency, threshold power, and directionality were obtained from cavities fabricated on a porous Nd:YAG ceramic.


  • Single‐Shot Reference‐Free Holographic Imaging using a Liquid Crystal Geometric Phase Diffuser

    by Jeonghun Oh, KyeoReh Lee, YongKeun Park

    It has been recently demonstrated that wavefront information can be directly measured using the speckle‐correlation scattering method. The realization of speckle‐correlation scattering requires the use of a diffusive layer; however, it poses technical challenges in characterizing the transmission matrix of the diffusive layer or precisely fabricating an engineered random metasurface. Herein, liquid crystal geometric phase diffusers are exploited for single‐shot reference‐free holographic imaging based on speckle‐correlation scattering. It is demonstrated that the use of a commercial geometric phase diffuser provides precise holographic measurements in a simple imaging setup, with no calibration required. This low‐cost, simple, and high‐resolution wavefront sensing approach inspired by liquid crystal materials may find direct applications in metrology, industrial inspection, and biophotonics.


  • Open Access

    Non-resonant power-efficient directional Nd:YAG ceramic laser using a scattering cavity

    by KyeoReh Lee, Ho Jin Ma, Fabian Rotermund, Do Kyung Kim, YongKeun Park

    Non-resonant lasers exhibit the potential for stable and consistent narrowband light sources. Furthermore, non-resonant lasers do not require well-defined optics, and thus has considerably diversified the available types of laser gain materials including powders, films, and turbid ceramics. Despite these intrinsic advantages, the practical applications of non-resonant lasers have been limited so far, mainly because of their low power efficiency and omnidirectional emission. To overcome these limitations, here we propose a light trap design for non-resonant lasers based on a spherical scattering cavity with a small entrance. Using a porous Nd3+:YAG ceramic, directional laser emission could be observed with significant enhancements in the slope efficiency and linewidth (down to 32 pm). A theoretical model is also developed to describe and predict the operation characteristics of proposed non-resonant laser.


  • Low-coherence optical diffraction tomography using a ferroelectric liquid crystal spatial light modulator

    by Chansuk Park, KyeoReh Lee, Yoonseok Baek, YongKeun Park

    Optical diffraction tomography (ODT) is a three-dimensional (3D) label-free imaging technique. The 3D refractive index distribution of a sample can be reconstructed from multiple two-dimensional optical field images via ODT. Herein, we introduce a temporally low-coherence ODT technique using a ferroelectric liquid crystal spatial light modulator (FLC SLM). The fast binary-phase modulation provided by the FLC SLM ensures the high spatiotemporal resolution. To reduce coherent noise, a superluminescent light-emitting diode is used as an economic low-coherence light source. We demonstrate the performance of the proposed system using various samples, including colloidal microspheres and live epithelial cells.


  • Open Access

    Speckle-Correlation Scattering Matrix Approaches for Imaging and Sensing through Turbidity

    by YoonSeok Baek, KyeoReh Lee, Jeonghun Oh, YongKeun Park

    The development of optical and computational techniques has enabled imaging without the need for traditional optical imaging systems. Modern lensless imaging techniques overcome several restrictions imposed by lenses, while preserving or even surpassing the capability of lens-based imaging. However, existing lensless methods often rely on a priori information about objects or imaging conditions. Thus, they are not ideal for general imaging purposes. The recent development of the speckle-correlation scattering matrix (SSM) techniques facilitates new opportunities for lensless imaging and sensing. In this review, we present the fundamentals of SSM methods and highlight recent implementations for holographic imaging, microscopy, optical mode demultiplexing, and quantification of the degree of the coherence of light. We conclude with a discussion of the potential of SSM and future research directions.