Cheng-Huang Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Cheng-Huang Lin has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
Ju‐Tsung Liu
4 shared publicationsDerrick Ethelbhert Yu
Department of Chemistry, De La Salle University, Manila, Philippines
3 shared publicationsGil Nonato Santos
Department of Physics, De La Salle University, Manila, Philippines
3 shared publicationsJu-Tsung Liu
Department of Defense, Forensic Science Center, Military Police Command, Taipei, Taiwan
3 shared publicationsToshio Kasai
Department of Chemistry National Taiwan University Taipei Taiwan
3 shared publicationsChien-Chung Chen
Graduate Institute of Biomedical Materials and Tissue Engineering, Taipei Medical University
2 shared publications
Latest Publications
- 19 March 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (14) , 2147-2151
Capillary action-driven surface-enhanced Raman spectroscopy (SERS) for the identification of phthalocyanine blue in modern paintings based on the BPG spot test
A method for the extraction and accumulation of Ag nanoparticles utilizing capillary action through a piece of triangular-shaped cotton paper is reported. This method allowed the integration of SERS and the BPG spot test, which are typically employed for examining pigments on paper or in books. Malachite green oxalate was used as the model material for investigating the extent of enhancement when SERS was applied. The dynamic behavior of the Ag nanoparticles was also studied. When the cotton paper was pre-treated with malachite green oxalate, Ag nanoparticles could be extracted and accumulated on the triangular top, resulting in a dramatic SERS improvement. When malachite green oxalate (at a concentration of 10−6 M) was applied using this method, a dramatic analytical enhancement factor of approximately 3000% was obtained. Finally, the method developed in this study was successfully applied to the analysis of pigments in paintings from a university collection. The findings revealed that phthalocyanine blue was a popular pigment used in numerous paintings during the 1950s.
- 19 March 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (14) , 2147-2151
Capillary action-driven surface-enhanced Raman spectroscopy (SERS) for the identification of phthalocyanine blue in modern paintings based on the BPG spot test
A method for the extraction and accumulation of Ag nanoparticles utilizing capillary action through a piece of triangular-shaped cotton paper is reported. This method allowed the integration of SERS and the BPG spot test, which are typically employed for examining pigments on paper or in books. Malachite green oxalate was used as the model material for investigating the extent of enhancement when SERS was applied. The dynamic behavior of the Ag nanoparticles was also studied. When the cotton paper was pre-treated with malachite green oxalate, Ag nanoparticles could be extracted and accumulated on the triangular top, resulting in a dramatic SERS improvement. When malachite green oxalate (at a concentration of 10−6 M) was applied using this method, a dramatic analytical enhancement factor of approximately 3000% was obtained. Finally, the method developed in this study was successfully applied to the analysis of pigments in paintings from a university collection. The findings revealed that phthalocyanine blue was a popular pigment used in numerous paintings during the 1950s.
- 10 January 2024
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 71 (8) , 925-931
Color analysis and tracking of the reduction of an indigo solution in real‐time using LabVIEW and machine vision
- 10 January 2024
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 71 (8) , 925-931
Color analysis and tracking of the reduction of an indigo solution in real‐time using LabVIEW and machine vision
- 2 January 2024
- Published by Springer Nature in Analytical Sciences
- Vol. 40 (3) , 489-499
Quantification of peracetic acid (PAA) in the H2O2 + acetic acid reaction by the wavelength shift analysis in near-UV/visible absorption region
In our study, we present an innovative method for the analysis and real-time monitoring of peracetic acid (PAA) formation within the near-UV/Vis (visible) wavelength region. PAA's absorption spectrum, influenced by its presence in a complex quaternary equilibrium mixture with hydrogen peroxide (H2O2), acetic acid, and water, lacks discernible peaks. This inherent complexity challenges conventional analytical techniques like Beer's law, which rely on absorption intensity as a foundation. To address this challenge, we introduce a novel approach that centers on the analysis of blue shifts in absorption wavelengths, particularly at an absorbance of 0.8 a.u. This method significantly enhances the precision of calibration curves for both diluted PAA and H2O2, unveiling an exponential correlation between wavelength and the logarithm of concentration for both components. Significantly, our approach allows for real-time and accurate measurements, especially during the dynamic PAA formation reaction. Our results exhibit excellent agreement with data obtained from Fourier-transform infrared (FT-IR) spectroscopy, validating the reliability of our method. It's noteworthy that under stable PAA concentration conditions (after 12 h of solution interaction), both traditional absorption method and our approach closely align with the FT-IR method. However, in dynamic scenarios (0−12 h), the absorption method exhibits higher error rates compared to our approach. Additionally, the increased concentration of a catalyst, sulfuric acid (H2SO4), significantly reduces the errors in both methods, a finding that warrants further exploration. In summary, our study not only advances our understanding of PAA and its spectral behavior but also introduces innovative and precise methods for determining PAA concentration in complex solutions. These advancements hold the potential to revolutionize the field of chemical analysis and spectroscopy. Graphical abstract
- 2 January 2024
- Published by Springer Nature in Analytical Sciences
- Vol. 40 (3) , 489-499
Quantification of peracetic acid (PAA) in the H2O2 + acetic acid reaction by the wavelength shift analysis in near-UV/visible absorption region
In our study, we present an innovative method for the analysis and real-time monitoring of peracetic acid (PAA) formation within the near-UV/Vis (visible) wavelength region. PAA's absorption spectrum, influenced by its presence in a complex quaternary equilibrium mixture with hydrogen peroxide (H2O2), acetic acid, and water, lacks discernible peaks. This inherent complexity challenges conventional analytical techniques like Beer's law, which rely on absorption intensity as a foundation. To address this challenge, we introduce a novel approach that centers on the analysis of blue shifts in absorption wavelengths, particularly at an absorbance of 0.8 a.u. This method significantly enhances the precision of calibration curves for both diluted PAA and H2O2, unveiling an exponential correlation between wavelength and the logarithm of concentration for both components. Significantly, our approach allows for real-time and accurate measurements, especially during the dynamic PAA formation reaction. Our results exhibit excellent agreement with data obtained from Fourier-transform infrared (FT-IR) spectroscopy, validating the reliability of our method. It's noteworthy that under stable PAA concentration conditions (after 12 h of solution interaction), both traditional absorption method and our approach closely align with the FT-IR method. However, in dynamic scenarios (0−12 h), the absorption method exhibits higher error rates compared to our approach. Additionally, the increased concentration of a catalyst, sulfuric acid (H2SO4), significantly reduces the errors in both methods, a finding that warrants further exploration. In summary, our study not only advances our understanding of PAA and its spectral behavior but also introduces innovative and precise methods for determining PAA concentration in complex solutions. These advancements hold the potential to revolutionize the field of chemical analysis and spectroscopy. Graphical abstract
- 24 May 2023
- Published by Springer Nature in Analytical Sciences
- Vol. 39 (9) , 1607-1612
The use of RGB-tracking of color changes during indigo-reduction processes based on LabVIEW machine vision
The use of an RGB-tracking chart for monitoring the reduction of indigo (color changes) based on the LabVIEW machine vision is demonstrated for the first time. In contrast to a normal analytical chromatographic chart, the time scale is used on the X-axis, but the sum of “RGB-pixels” is used on the Y-axis, instead of “signal intensity”. The RGB-tracking chart was obtained from an investigation of the process involved in the reduction of indigo, in which a PC camera was used as a detector and LabVIEW machine vision was simultaneously operated. As a result, when sodium dithionite (Na2S2O4) and yeast were used, respectively, during the indigo-reduction processes, two types of reduction processes were found; the optimized timing for dyeing can be easily determined from the RGB-tracking charts. Furthermore, based on the changes in HSV (hue, saturation, lightness), the use of sodium dithionite provides a higher number of hue and saturation when clothes & fabric were dyed. In contrast to this, a longer time was required for the yeast solution to reach the same high number for hue and saturation. After comparing several series of dyed fabrics, we found that the use of an RGB-tracking chart is indeed a reliable novel tool for measuring color changes that occur during the chemical reactions that are associated with this process. Graphical abstract
- 24 May 2023
- Published by Springer Nature in Analytical Sciences
- Vol. 39 (9) , 1607-1612
The use of RGB-tracking of color changes during indigo-reduction processes based on LabVIEW machine vision
The use of an RGB-tracking chart for monitoring the reduction of indigo (color changes) based on the LabVIEW machine vision is demonstrated for the first time. In contrast to a normal analytical chromatographic chart, the time scale is used on the X-axis, but the sum of “RGB-pixels” is used on the Y-axis, instead of “signal intensity”. The RGB-tracking chart was obtained from an investigation of the process involved in the reduction of indigo, in which a PC camera was used as a detector and LabVIEW machine vision was simultaneously operated. As a result, when sodium dithionite (Na2S2O4) and yeast were used, respectively, during the indigo-reduction processes, two types of reduction processes were found; the optimized timing for dyeing can be easily determined from the RGB-tracking charts. Furthermore, based on the changes in HSV (hue, saturation, lightness), the use of sodium dithionite provides a higher number of hue and saturation when clothes & fabric were dyed. In contrast to this, a longer time was required for the yeast solution to reach the same high number for hue and saturation. After comparing several series of dyed fabrics, we found that the use of an RGB-tracking chart is indeed a reliable novel tool for measuring color changes that occur during the chemical reactions that are associated with this process. Graphical abstract
- 28 April 2023
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 70 (6) , 1427-1434
Kinetic and equilibrium analysis of peracetic acid formation at 1753 cm−1 mid‐infrared absorption peak using facile attenuated total reflection Fourier transform Infrared technique
Introduction: Peracetic acid (PAA) is a highly effective disinfectant against a wide range of viruses and bacteria. Its versatility, cost‐effectiveness, and ability to quickly decontaminate large areas make it an ideal choice. PAA is also environmentally friendly and safe, as it does not produce any harmful by‐products. However, to ensure its efficacy, it is crucial to maintain the optimal concentration of PAA in the solution.Objective: The objective of the study is to investigate the use of attenuated total reflection Fourier transform infrared (ATR‐FTIR) spectroscopy as a method for quantifying the concentration of peracetic acid (PAA), which comes in quaternary equilibrium mixture in commercial formulation. The study also aims to determine the rate constants and equilibrium constant for the production of PAA in various conditions, including the presence of catalyst and stabilizer.Methods: The spectra of all chemicals in PAA solution obtained in FT‐IR Spectrometer were compared to identify the characteristic peaks of PAA, which were then computed using normal mode analysis at B3LYP/6‐31G(d) level by Gaussian 09. The ATR‐FTIR was used to measure time‐dependent PAA signals until they reached equilibrium in three different conditions: (1) Acetic acid (10 to 17.4 M) and hydrogen peroxide (5 M), (2) with sulfuric acid as catalyst, and (3) with phosphoric acid as stabilizer. The collected data was analyzed through regression analysis, in which curves and rate law formulas were fitted to obtain the rate constants for peracetic acid synthesis and hydrolysis.Results: This study shows that ATR‐FTIR spectroscopy can detect and quantify peracetic acid with a characteristic peak at 1753 cm−1. The proposed method is applicable to all peracetic acid solutions, including those with stabilizers and catalysts. The ATR‐FTIR method offers advantages such as short detection time, simple operation, small sampling volume, and accurate measurement. Moreover, the accuracy of this quantitative method is confirmed by the fact that the reaction rate constants deduced from the fitted curves are more consistent with the actual reaction rate constants than those of the reference data based on KI titration method.
- 28 April 2023
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 70 (6) , 1427-1434
Kinetic and equilibrium analysis of peracetic acid formation at 1753 cm−1 mid‐infrared absorption peak using facile attenuated total reflection Fourier transform Infrared technique
Introduction: Peracetic acid (PAA) is a highly effective disinfectant against a wide range of viruses and bacteria. Its versatility, cost‐effectiveness, and ability to quickly decontaminate large areas make it an ideal choice. PAA is also environmentally friendly and safe, as it does not produce any harmful by‐products. However, to ensure its efficacy, it is crucial to maintain the optimal concentration of PAA in the solution.Objective: The objective of the study is to investigate the use of attenuated total reflection Fourier transform infrared (ATR‐FTIR) spectroscopy as a method for quantifying the concentration of peracetic acid (PAA), which comes in quaternary equilibrium mixture in commercial formulation. The study also aims to determine the rate constants and equilibrium constant for the production of PAA in various conditions, including the presence of catalyst and stabilizer.Methods: The spectra of all chemicals in PAA solution obtained in FT‐IR Spectrometer were compared to identify the characteristic peaks of PAA, which were then computed using normal mode analysis at B3LYP/6‐31G(d) level by Gaussian 09. The ATR‐FTIR was used to measure time‐dependent PAA signals until they reached equilibrium in three different conditions: (1) Acetic acid (10 to 17.4 M) and hydrogen peroxide (5 M), (2) with sulfuric acid as catalyst, and (3) with phosphoric acid as stabilizer. The collected data was analyzed through regression analysis, in which curves and rate law formulas were fitted to obtain the rate constants for peracetic acid synthesis and hydrolysis.Results: This study shows that ATR‐FTIR spectroscopy can detect and quantify peracetic acid with a characteristic peak at 1753 cm−1. The proposed method is applicable to all peracetic acid solutions, including those with stabilizers and catalysts. The ATR‐FTIR method offers advantages such as short detection time, simple operation, small sampling volume, and accurate measurement. Moreover, the accuracy of this quantitative method is confirmed by the fact that the reaction rate constants deduced from the fitted curves are more consistent with the actual reaction rate constants than those of the reference data based on KI titration method.
- 11 April 2022
- Published by Springer Nature in Analytical Sciences
- Vol. 38 (4) , 711-716
Investigation of optimal conditions needed for the production of indigo and subsequent dyeing using CO2/O2 sensors and a cellphone camera
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 11 April 2022
- Published by Springer Nature in Analytical Sciences
- Vol. 38 (4) , 711-716
Investigation of optimal conditions needed for the production of indigo and subsequent dyeing using CO2/O2 sensors and a cellphone camera
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 1 March 2022
- Published by Springer Nature in Analytical Sciences
- Vol. 38 (3) , 483-495
Comparison and characterization of pigments and dyes by Raman spectroscopy
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 1 March 2022
- Published by Springer Nature in Analytical Sciences
- Vol. 38 (3) , 483-495
Comparison and characterization of pigments and dyes by Raman spectroscopy
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 8 September 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (19) , 12763-12768
A Dynamic Data Correction Method for Enhancing Resolving Power of Integrated Spectra in Spectroscopic Analysis
A dynamic data correction method embedded in the process of data acquisition improves spectral quality. The method minimizes the impact of random errors in spectroscopic measurements by correcting peak positions in every single-scan spectrum. The method is fast enough to facilitate on-line data correction. Integration of corrected spectra improves resolving power and signal-to-noise ratio. The correction method can apply to most analytical spectra. In mass spectrometry and Raman spectroscopy, observations show that it improved the average resolving power by roughly 40 – 150% and revealed unresolved spectral features.
- 8 September 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (19) , 12763-12768
A Dynamic Data Correction Method for Enhancing Resolving Power of Integrated Spectra in Spectroscopic Analysis
A dynamic data correction method embedded in the process of data acquisition improves spectral quality. The method minimizes the impact of random errors in spectroscopic measurements by correcting peak positions in every single-scan spectrum. The method is fast enough to facilitate on-line data correction. Integration of corrected spectra improves resolving power and signal-to-noise ratio. The correction method can apply to most analytical spectra. In mass spectrometry and Raman spectroscopy, observations show that it improved the average resolving power by roughly 40 – 150% and revealed unresolved spectral features.
- 10 January 2020
- Published by Springer Nature in Analytical Sciences
- Vol. 36 (6) , 739-743
Non-invasive and Time-dependent Blood-sugar Monitoring via Breath-derived CO2 Correlation Using Gas Chromatograph with a Milli-whistle Gas Analyzer
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 10 January 2020
- Published by Springer Nature in Analytical Sciences
- Vol. 36 (6) , 739-743
Non-invasive and Time-dependent Blood-sugar Monitoring via Breath-derived CO2 Correlation Using Gas Chromatograph with a Milli-whistle Gas Analyzer
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 1 July 2018
- Published by Elsevier in International Journal of Mass Spectrometry
- Vol. 430, 104-109
Rapid on-line microextraction method for the analysis of glyphosate in soy and pepper based on fiber-spray/mass spectrometry
- 1 July 2018
- Published by Elsevier in International Journal of Mass Spectrometry
- Vol. 430, 104-109
Rapid on-line microextraction method for the analysis of glyphosate in soy and pepper based on fiber-spray/mass spectrometry