Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lars Rene Lindvold has a total of 91 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Pedestal High-Contrast Gratings for Biosensing

    by Leonid Yu. Beliaev, Peter Groth Stounbjerg, Giovanni Finco, Ada-Ioana Bunea, Radu Malureanu, Lars René Lindvold, Osamu Takayama, Peter E. Andersen, Andrei V. Lavrinenko

    High-contrast gratings (HCG) are an excellent candidate for label-free detection of various kinds of biomarkers because they exhibit sharp and sensitive optical resonances. In this work, we experimentally show the performance of pedestal HCG (PHCG), which is significantly enhanced in comparison with that of conventional HCG. PCHGs were found to provide a 11.2% improvement in bulk refractive index sensitivity, from 482 nm/RIU for the conventional design to 536 nm/RIU. The observed resonance was narrower, resulting in a higher Q-factor and figure of merit. By depositing Al2O3, HfO2, and TiO2 of different thicknesses as model analyte layers, surface sensitivity values were estimated to be 10.5% better for PHCG. To evaluate the operation of the sensor in solution, avidin was employed as a model analyte. For avidin detection, the surface of the HCG was first silanized and subsequently functionalized with biotin, which is well known for its ability to bind selectively to avidin. A consistent red shift was observed with the addition of each of the functional layers, and the analysis of the spectral shift for various concentrations of avidin made it possible to calculate the limit of detection (LoD) and limit of quantification (LoQ) for the structures. PHCG showed a LoD of 2.1 ng/mL and LoQ of 85 ng/mL, significantly better than the values 3.2 ng/mL and 213 ng/mL respectively, obtained with the conventional HCG. These results demonstrate that the proposed PHCG have great potential for biosensing applications, particularly for detecting and quantifying low analyte concentrations.


  • Open Access

    Characterization of a Radiofluorogenic Polymer for Low-Energy Electron Beam Penetration Depth Visualization

    by Magdalena Maria Skowyra, Christina Ankjærgaard, Liyun Yu, Lars René Lindvold, Anne Ladegaard Skov, Arne Miller

    Low-energy (80–300 keV) electron beam accelerators are gaining in importance in the radiation processing industry due to their ease of use and wide range of applications (e.g. product surface sterilizations or polymer curing and cross-linking). Due to their very low penetration depth (tens to hundreds of microns), currently used film dosimeters exhibit dose gradients over their thickness and do not resolve the dose response in the first microns of the irradiated material. Hence, the surface dose, defined as the dose in the first micron Dµ, cannot be measured directly. This study presents a polymer material as a dosimeter candidate for high-dose low-energy electron beam irradiations. The readout of the dose-dependent fluorescence intensity, originating from a pararosaniline dye reaction when irradiated, is measured using fluorescence microscopy. So far, no in-depth characterization of the material has been performed, leaving the stability and fluorescence properties of the material not fully optimized. We describe the improvements in polymer composition and the fabrication method, and characterize the material properties in terms of the thermal stability, glass transition temperature, refractive index, hardness, rheological behavior, and water affinity. All of these create a complex set of requirements a polymer needs to fulfill to become an effective dosimeter when measuring using confocal microscopy. The fluorescence readout procedure will be addressed in further studies.


  • Open Access

    Guided‐mode resonance on pedestal and half‐buried high‐contrast gratings for biosensing applications

    by Giovanni Finco, Mehri Ziaee Bideskan, Larissa Vertchenko, Leonid Y. Beliaev, Radu Malureanu, Lars René Lindvold, Osamu Takayama, Peter E. Andersen, Andrei V. Lavrinenko

    Optical sensors typically provide compact, fast and precise means of performing quantitative measures for almost any kind of measurand that is usually probed electronically. High‐contrast grating (HCG) resonators are known to manifest an extremely sharp and sensitive optical resonance and can constitute a highly suitable sensing platform. In this paper we present two advanced high‐contrast grating designs improving the sensing performances of conventional implementations. These configurations, namely pedestal and half‐buried HCGs, allow to enhance the shift of the photonic resonance while maintaining the spectral features of the standard configuration. First, the spectral feature of the HCGs was numerically optimized to express the sharpest possible resonance when the structure is immersed in serum. Second, the sensing properties of conventional and advanced HCG implementations were studied by modelling the biological entities to be sensed as a thin dielectric coating layer of increasing thickness. Pedestal HCGs were found to provide a ∼12% improvement in sensitivity and a six‐fold improvement in resonance quality factor ( Q ‐factor), while buried HCGs resulted in a ∼58% improvement in sensitivity at the expense of a slightly broader resonance. Such structures may serve as an improved sensitive biosensing platform for near‐infrared spectroscopy.


  • Room‐Temperature, High‐SNR Upconversion Spectrometer in the 6–12 µm Region

    by Peter John Rodrigo, Lasse Høgstedt, Søren Michael Mørk Friis, Lars René Lindvold, Peter Tidemand‐Lichtenberg, Christian Pedersen

    Mid‐infrared (MIR) spectroscopy, which has important applications in medicine, environmental monitoring, materials, and food science, is widely performed using Fourier transform infrared (FTIR) spectrometers as gold standard. Despite decades of development, FTIR systems are vulnerable to vibration and have limited temporal resolution due to reliance on mechanically scanned mirrors and MIR direct detectors that have a slower response than their near‐infrared counterparts. Using cryogenically cooled detectors, state‐of‐the‐art FTIR systems have reached a signal‐to‐noise ratio (SNR) of ≈6000 at 1 s integration time (at 4 cm−1 spectral resolution). Here, a novel MIR upconversion spectrometer (MIRUS) is presented with a record‐high SNR > 10 000 at 1 s (6 cm−1 resolution), outperforming FTIR systems by circumventing the need for sophisticated cooling and any moving part, thus enabling operation in harsh environments. It has a spectral coverage of 6–12 µm—the broadest for an upconversion spectrometer to date. The MIRUS uses broadband intracavity upconversion to convert the signal spanning the MIR fingerprint region to the near‐infrared where sensitive Si‐detector based spectrometers operate with rates easily reaching kilo spectra per second. Applications of MIRUS for gas sensing, plastic identification, and rapid photopolymerization monitoring are demonstrated.


  • Direct Injection of Ultrashort Electron Bunches Into a Solid Material Using Terahertz-Driven Electron Field Emission

    by Simon L. Lange, Lars Rene Lindvold, Peter U. Jepsen

    We present here how terahertz (THz)-driven electron field emission from gold antennas can be directly injected into a solid material without any intermediate vacuum path. Simulations show that an ultrashort sub-ps driving THz laser pulse results in even shorter sub-ps electron bunches with up to 420 eV energies under vacuum conditions. An experiment shows that these electron bunches can be formed and accelerated directly inside the bulk of a solid under standard laboratory conditions (SLC). This is observed via the interaction of the electrons with scintillating molecules, which are placed inside the solid. Our result is a key step towards building a novel platform for femtochemistry driven by ultrashort electron bunches.

  • Radiochromic and radiofluorogenic 3D solid polymer dosimeter; effect of the photoinitiator

    by M.R. Bernal-Zamorano, N.H. Sanders, L. Lindvold, C.E. Andersen


  • Open Access

    Radiochromic and radiofluorogenic 3D solid polymer dosimeter: initial results for high doses

    by María del Rocío Bernal Zamorano, Nicolai Højer Sanders, Lars René Lindvold, Claus E. Andersen

    The complexity of dose distributions has increased with the advent of intensity modulated radiation therapy (IMRT). For that reason, experimental measurements using 3D dosimeters with high spatial resolution are required to check the delivered dose. In this study a new 3D solid polymer dosimeter with absorbance and fluorescence responses to radiation is presented. Measuring fluorescence instead of absorbance improves the spatial resolution and eases the read out of the dosimeter. The proposed dosimeter is tissue-equivalent and can be moulded in any shape by a controllable and fast photopolymerization process.


  • Open Access

    Optimization of laboratory illumination in optical dating

    by Reza Sohbati, Andrew Murray, Lars Lindvold, Jan-Pieter Buylaert, Mayank Jain