Mohammad Mahdi Hosseini-Biyouki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohammad Mahdi Hosseini-Biyouki has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Hossein Askarian Abyaneh
Amirkabir University of Technology
4 shared publications - Aydin Zaboli
Department of Electrical and Computer Engineering, University of MichiganDearborn, Dearborn, MI, USA
3 shared publications Sasan Yousefi
Department of Electrical Engineering, Amirkabir University of Technology, Tehran, Iran
3 shared publications- Behrooz Vahidi
Department of Electrical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
2 shared publications Mehdi Zareian Jahromi
Department of Electrical and Computer Engineering, Kerman Graduate University of Technology, Iran
2 shared publicationsRoohollah Fadaeinedjad
Department of Electrical and Computer Engineering, Kerman Graduate University of Technology, Iran
2 shared publications
Latest Publications
- 2 October 2017
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 45 (16) , 1762-1772
Impact of Optimal Unified Power Flow Controller in Electrical Transmission Systems in Reducing Transmission Cost
This paper presents an approach to optimal placement of optimal unified power flow controller (OUPFC) in electrical transmission systems utilizing genetic algorithm (GA), while reducing transmission systems cost using MATLAB and MATPOWER. The proposed approach is based on optimal power flow (OPF) considering optimization of power systems operation conditions. In order to determine the appropriate place for installation of OUPFC, while considering power injection model of this controller, OPF is utilized to obtain multi-objective function of the optimization problem. In this regard, the objective function comprises generation cost, transmission cost, and OUPFC installation cost. The proposed approach is applied to IEEE 30-bus test system, where the obtained results demonstrate remarkable reduction in overall cost of power system.
- 2 October 2017
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 45 (16) , 1762-1772
Impact of Optimal Unified Power Flow Controller in Electrical Transmission Systems in Reducing Transmission Cost
This paper presents an approach to optimal placement of optimal unified power flow controller (OUPFC) in electrical transmission systems utilizing genetic algorithm (GA), while reducing transmission systems cost using MATLAB and MATPOWER. The proposed approach is based on optimal power flow (OPF) considering optimization of power systems operation conditions. In order to determine the appropriate place for installation of OUPFC, while considering power injection model of this controller, OPF is utilized to obtain multi-objective function of the optimization problem. In this regard, the objective function comprises generation cost, transmission cost, and OUPFC installation cost. The proposed approach is applied to IEEE 30-bus test system, where the obtained results demonstrate remarkable reduction in overall cost of power system.
- Top Cited Papers
- 20 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 66 (2) , 974-980
Evaluation and Control of Stray Current in DC-Electrified Railway Systems
In urban electric railway transit systems, rails are used to navigate trains, as well as to provide the returning path of the train's electric current to the traction power substation (TPS). Due to electrical resistance of rails and the rail-to-ground conductivity, a part of the train's returning current to the TPS flows into the ground, which is called stray current, which causes different problems such as an increase of rail potential. In this regard, a model of an electric train with a TPS, running rail, and third rail is simulated in MATLAB/Simulink. In the simulated model, the amounts of stray currents in different soil types, with and without collection mats, are compared. Afterward, to calculate the amount of stray current in the presence of the stray current control method considering different soil types through finite-element (FE) method (FEM), a UIC54 rail with insulated fastening equipment is modeled in FEMM 4.2 and analyzed with 2-D FEM. Finally, a comparison of efficiency of stray current collection mats in different soil models for both simulation in MATLAB/Simulink and FEM is also presented. The obtained results verify the accuracy of the simulated and modeled system in real conditions of electric railways.
- 20 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 66 (2) , 974-980
Top Cited PapersEvaluation and Control of Stray Current in DC-Electrified Railway Systems
In urban electric railway transit systems, rails are used to navigate trains, as well as to provide the returning path of the train's electric current to the traction power substation (TPS). Due to electrical resistance of rails and the rail-to-ground conductivity, a part of the train's returning current to the TPS flows into the ground, which is called stray current, which causes different problems such as an increase of rail potential. In this regard, a model of an electric train with a TPS, running rail, and third rail is simulated in MATLAB/Simulink. In the simulated model, the amounts of stray currents in different soil types, with and without collection mats, are compared. Afterward, to calculate the amount of stray current in the presence of the stray current control method considering different soil types through finite-element (FE) method (FEM), a UIC54 rail with insulated fastening equipment is modeled in FEMM 4.2 and analyzed with 2-D FEM. Finally, a comparison of efficiency of stray current collection mats in different soil models for both simulation in MATLAB/Simulink and FEM is also presented. The obtained results verify the accuracy of the simulated and modeled system in real conditions of electric railways.
- 7 April 2015
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 43 (7) , 733-746
A Stochastic Programming to Volt/VAR/Total Harmonic Distortion Control in Distribution Networks Including Wind Turbines
—This article presents a stochastic methodology for volt/VAR/total harmonic distortion control to reduce power losses while satisfying the main recommended power quality standards and optimizing dispatch schedules for the switchable shunt capacitor and on-load tap-changer in distribution networks. The main aim is to find proper dispatch schedules for on-load tap-changer tap positions, substation capacitors, and along feeder capacitors. For this purpose, distribution network uncertainties, including load demand and wind power generation, are considered to provide a robust control scheme. A new scenario reduction method based on the highest potential cluster center is used to decrease the huge number of probable states. A new scenario-based probabilistic time-interval division framework, over a 24-hr period on both load curve and wind power output, is introduced to reduce effects of forecast plan uncertainty and switching operations in the on-load tap-changer. A genetic algorithm solution method is applied to find the best solution corresponding to various scenarios. To improve search ability, a method guaranteeing the suppression of maximum allowable daily substation capacitors switching and effectively correcting the convergence process is utilized. The proposed stochastic approach is tested on an IEEE 123-bus distribution network containing a number of non-linear loads and wind energy generation systems.
- 7 April 2015
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 43 (7) , 733-746
A Stochastic Programming to Volt/VAR/Total Harmonic Distortion Control in Distribution Networks Including Wind Turbines
—This article presents a stochastic methodology for volt/VAR/total harmonic distortion control to reduce power losses while satisfying the main recommended power quality standards and optimizing dispatch schedules for the switchable shunt capacitor and on-load tap-changer in distribution networks. The main aim is to find proper dispatch schedules for on-load tap-changer tap positions, substation capacitors, and along feeder capacitors. For this purpose, distribution network uncertainties, including load demand and wind power generation, are considered to provide a robust control scheme. A new scenario reduction method based on the highest potential cluster center is used to decrease the huge number of probable states. A new scenario-based probabilistic time-interval division framework, over a 24-hr period on both load curve and wind power output, is introduced to reduce effects of forecast plan uncertainty and switching operations in the on-load tap-changer. A genetic algorithm solution method is applied to find the best solution corresponding to various scenarios. To improve search ability, a method guaranteeing the suppression of maximum allowable daily substation capacitors switching and effectively correcting the convergence process is utilized. The proposed stochastic approach is tested on an IEEE 123-bus distribution network containing a number of non-linear loads and wind energy generation systems.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 287-292
Different hybrid filters configurations impact on an AC 25 kV electric train's harmonic mitigation
Nowadays power quality is one of the crucial issues in power systems. Among power quality issues, harmonics caused by nonlinear loads are of great importance as causing great problems in power systems such as malfunction of electrical devices, efficiency reduction as well as reduction of effective lifetime of electrical devices. Electric railways utilizing thyristor rectifiers in order to control speed consume enormous lead current and inject huge harmonic to the grid. In order to eliminate harmonic and compensate reactive power in electric railways, it is proper to use hybrid filters. Hybrid filters are a combination of active and passive filters. Regarding the way active and passive filters are connected in hybrid filters, they have different structures. In this paper, harmonic model of electric railway as well as some of the hybrid filters configurations are evaluated and their performance in electric railways are simulated in MATLAB/SIMULINK. Finally, performances of different configurations are compared to demonstrate their advantages and disadvantages in reducing current total harmonic distortion (THD).
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 287-292
Different hybrid filters configurations impact on an AC 25 kV electric train's harmonic mitigation
Nowadays power quality is one of the crucial issues in power systems. Among power quality issues, harmonics caused by nonlinear loads are of great importance as causing great problems in power systems such as malfunction of electrical devices, efficiency reduction as well as reduction of effective lifetime of electrical devices. Electric railways utilizing thyristor rectifiers in order to control speed consume enormous lead current and inject huge harmonic to the grid. In order to eliminate harmonic and compensate reactive power in electric railways, it is proper to use hybrid filters. Hybrid filters are a combination of active and passive filters. Regarding the way active and passive filters are connected in hybrid filters, they have different structures. In this paper, harmonic model of electric railway as well as some of the hybrid filters configurations are evaluated and their performance in electric railways are simulated in MATLAB/SIMULINK. Finally, performances of different configurations are compared to demonstrate their advantages and disadvantages in reducing current total harmonic distortion (THD).
- 1 January 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 59-63
Design of a new structure for hybrid filters to eliminate harmonics of 25 kV AC electric railways
In electric railways, thyristor rectifiers are used in order to control the speed. As a consequence in addition to substantial input lead current, an enormous amount of harmonics is injected into the grid. To avoid such harmonics as well as reactive power compensation, reactive power hybrid filters consisting of active and passive filters are utilized. Hybrid filters have several different structures. Since electric railway has a non-linear and variable nature, a novel hybrid filter structure is designed that compensates reactive power and eliminates harmonics to attain desired harmonic level regarding the conventional allowable harmonics level standards. The designed filter model is simulated in MATLAB/SIMULINK and then applied to a harmonic model of an electric railway.
- 1 January 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 59-63
Design of a new structure for hybrid filters to eliminate harmonics of 25 kV AC electric railways
In electric railways, thyristor rectifiers are used in order to control the speed. As a consequence in addition to substantial input lead current, an enormous amount of harmonics is injected into the grid. To avoid such harmonics as well as reactive power compensation, reactive power hybrid filters consisting of active and passive filters are utilized. Hybrid filters have several different structures. Since electric railway has a non-linear and variable nature, a novel hybrid filter structure is designed that compensates reactive power and eliminates harmonics to attain desired harmonic level regarding the conventional allowable harmonics level standards. The designed filter model is simulated in MATLAB/SIMULINK and then applied to a harmonic model of an electric railway.
- 1 January 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 64-70
Implementation of a high speed cumulative determinant-based fault detection algorithm for power system relaying
A high speed cumulative determinant-based fault detection algorithm is presented in this paper. The proposed algorithm is proven to be faster and more reliable than other conventional sample-based methods such as sample to sample, cycle to cycle and cumulative sum based algorithms especially for high impedance faults. In the developed methodology, the impact of important parameters such as noise, frequency deviation, current spikes and sudden load changes as well as fault detection speed are considered to evaluate the algorithm applicability. The algorithm is applied to a single line to ground (SLG) fault in a simple two source model as well as a SLG in MANESHT to ESLAMABAD-E-GHARB 230kV power transmission line of Iran national grid as a real case.
- 1 January 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 64-70
Implementation of a high speed cumulative determinant-based fault detection algorithm for power system relaying
A high speed cumulative determinant-based fault detection algorithm is presented in this paper. The proposed algorithm is proven to be faster and more reliable than other conventional sample-based methods such as sample to sample, cycle to cycle and cumulative sum based algorithms especially for high impedance faults. In the developed methodology, the impact of important parameters such as noise, frequency deviation, current spikes and sudden load changes as well as fault detection speed are considered to evaluate the algorithm applicability. The algorithm is applied to a single line to ground (SLG) fault in a simple two source model as well as a SLG in MANESHT to ESLAMABAD-E-GHARB 230kV power transmission line of Iran national grid as a real case.
- 1 November 2013
- Published by Elsevier in Journal of Power Sources
- Vol. 242, 122-131
An implementation of particle swarm optimization to evaluate optimal under-voltage load shedding in competitive electricity markets
- 1 November 2013
- Published by Elsevier in Journal of Power Sources
- Vol. 242, 122-131
An implementation of particle swarm optimization to evaluate optimal under-voltage load shedding in competitive electricity markets
- 16 November 2012
- Published by Springer Nature in Electrical Engineering
- Vol. 95 (4) , 341-355
A combinatorial artificial intelligence real-time solution to the unit commitment problem incorporating V2G
- 16 November 2012
- Published by Springer Nature in Electrical Engineering
- Vol. 95 (4) , 341-355
A combinatorial artificial intelligence real-time solution to the unit commitment problem incorporating V2G
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 661-666
Transmission and generation expansion planning considering loadability limit using game theory & ANN
Transmission and generation expansion planning (TEP and GEP) considering loadability limit of power system is studied in this paper. Artificial neural network (ANN) technique is used to evaluate loadability limit of the power system because of its sensitivity characteristic. Power system restructuring and separation of decision-making organizations of transmission and generation expansion, make coordination between generation and transmission companies more crucial. On the other hand, voltage stability is one of the indicators of power system security level. In this paper, first the load pattern of a six-bus power system is improved and then the best bus for load increment is determined using sensitivity characteristic of ANN. Afterwards the strategic interaction between transmission company (TransCo) and generation company (GenCo) for TEP and GEP in a competitive electricity market is proposed using Game Theory (GT). The proposed algorithm comprises three optimization levels to determine Nash equilibrium such that the most profitable strategy for both sides of the game can be found out in an expansion planning game.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 661-666
Transmission and generation expansion planning considering loadability limit using game theory & ANN
Transmission and generation expansion planning (TEP and GEP) considering loadability limit of power system is studied in this paper. Artificial neural network (ANN) technique is used to evaluate loadability limit of the power system because of its sensitivity characteristic. Power system restructuring and separation of decision-making organizations of transmission and generation expansion, make coordination between generation and transmission companies more crucial. On the other hand, voltage stability is one of the indicators of power system security level. In this paper, first the load pattern of a six-bus power system is improved and then the best bus for load increment is determined using sensitivity characteristic of ANN. Afterwards the strategic interaction between transmission company (TransCo) and generation company (GenCo) for TEP and GEP in a competitive electricity market is proposed using Game Theory (GT). The proposed algorithm comprises three optimization levels to determine Nash equilibrium such that the most profitable strategy for both sides of the game can be found out in an expansion planning game.
- 1 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 676-681
Simulation of a stirling engine solar power generation system using Simulink
In order to fully study a Stirling engine based solar power generation system, a detailed model that considers all thermal, mechanical, and electrical aspects of the system should be used. Research in the area of Stirling engine systems has been performed either without considering the electrical parts, or with a simple model for the electrical parts. Hence, the effects of interactions between electrical and mechanical components are neglected. In this paper, simulation of a solar-powered Stirling engine system is proposed that considers all thermal, mechanical, and electrical aspects of the system. The system is mainly composed of two parts that are the mechanical and electrical parts. The mechanical part includes the Stirling engine that is modeled using thermal and mechanical equations in Matlab/Simulink environment. The electrical part consists of a synchronous generator, an ac/dc converter, a battery, and an electrical dc load that are simulated using Simulink blocks.
- 1 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 676-681
Simulation of a stirling engine solar power generation system using Simulink
In order to fully study a Stirling engine based solar power generation system, a detailed model that considers all thermal, mechanical, and electrical aspects of the system should be used. Research in the area of Stirling engine systems has been performed either without considering the electrical parts, or with a simple model for the electrical parts. Hence, the effects of interactions between electrical and mechanical components are neglected. In this paper, simulation of a solar-powered Stirling engine system is proposed that considers all thermal, mechanical, and electrical aspects of the system. The system is mainly composed of two parts that are the mechanical and electrical parts. The mechanical part includes the Stirling engine that is modeled using thermal and mechanical equations in Matlab/Simulink environment. The electrical part consists of a synchronous generator, an ac/dc converter, a battery, and an electrical dc load that are simulated using Simulink blocks.