Hervé Tatenguem
Hervé Tatenguem has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Davide Bertozzi
University of Ferrara, Italy
8 shared publicationsMorten Hoppe
Sacher Lasertechnik GmbH, Hedwig-Jahnow-Straße 12, D-35037 Marburg, Germany
8 shared publicationsTobias Milde
Sacher Lasertechnik GmbH, Rudolf-Breitscheid-Straße 5, 35037 Marburg, Germany
8 shared publicationsJoachim Sacher
Sacher Lasertechnik GmbH, Hedwig-Jahnow-Straße 12, D-35037 Marburg, Germany
7 shared publicationsAlberto Ghiribaldi
University of Ferrara, Italy
6 shared publications- Joachim Sacher
Sacher Lasertechnik GmbH (Germany)
6 shared publications
Latest Publications
- 1 January 2024
- Published by Optica Publishing Group
- p. AF3I.3
A Feed Forward Digital PID Controller with Auto-relocking Features for Sub-kHz External Cavity Diode Lasers
Narrow linewidth lasers with high stability are a key enabling technology in high-impact applications such as quantum technologies and laser surgery. Stabilizing such lasers requires the design of efficient Proportional-Integral-Derivative (PID) controllers. In order to tackle this design challenge, we successfully designed and used a PID to stabilize a VBG based external-cavity diode lasers with ultra-narrow linewidth.
- 1 January 2024
- Published by Optica Publishing Group
- p. AF3I.3
A Feed Forward Digital PID Controller with Auto-relocking Features for Sub-kHz External Cavity Diode Lasers
Narrow linewidth lasers with high stability are a key enabling technology in high-impact applications such as quantum technologies and laser surgery. Stabilizing such lasers requires the design of efficient Proportional-Integral-Derivative (PID) controllers. In order to tackle this design challenge, we successfully designed and used a PID to stabilize a VBG based external-cavity diode lasers with ultra-narrow linewidth.
- 1 January 2024
- Published by Optica Publishing Group
- p. ATh1E.4
QCL-QEPAS sensor for Rapid Multispecies Detection in the MIR region: Case studies CH4, C2H2, NH3 and N2O
To meet the requirements for multi-species gas analysis, quartz-enhanced photoacoustic spectroscopy (QEPAS) is used in combination with a QC-based external cavity laser system. Especially high scan rates are of great importance for the analysis and monitoring of multiple species in a sample, where the composition can change rapidly. By integrating piezoelectric actuators extremely high sampling rates can be achieved. In this work, results on the detection of multiple trace gases by sequential quasi-simultaneous measurements are presented. The requirements of multi-species detection, widely tuning range, fast switching, and low-cost system are met by our work.
- 1 January 2024
- Published by Optica Publishing Group
- p. ATh1E.4
QCL-QEPAS sensor for Rapid Multispecies Detection in the MIR region: Case studies CH4, C2H2, NH3 and N2O
To meet the requirements for multi-species gas analysis, quartz-enhanced photoacoustic spectroscopy (QEPAS) is used in combination with a QC-based external cavity laser system. Especially high scan rates are of great importance for the analysis and monitoring of multiple species in a sample, where the composition can change rapidly. By integrating piezoelectric actuators extremely high sampling rates can be achieved. In this work, results on the detection of multiple trace gases by sequential quasi-simultaneous measurements are presented. The requirements of multi-species detection, widely tuning range, fast switching, and low-cost system are met by our work.
- 1 January 2023
- Published by Optica Publishing Group
- p. JW2A.72
Design of a Digital PID with High Bandwidth for Locking DFB Laser to an Absorption line of CH4
Analog PID controllers, although offering higher bandwidth than digital PIDs, generally suffer from a lack of features such as variable parameter tuning. We report on enhancing bandwidth of digital PID and their application in methane absorption line stability.
- 1 January 2023
- Published by Optica Publishing Group
- p. JW2A.72
Design of a Digital PID with High Bandwidth for Locking DFB Laser to an Absorption line of CH4
Analog PID controllers, although offering higher bandwidth than digital PIDs, generally suffer from a lack of features such as variable parameter tuning. We report on enhancing bandwidth of digital PID and their application in methane absorption line stability.
- 9 April 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (15) , C55-C59
QEPAS sensor in a butterfly package and its application
Molecular gases are highly relevant in healthcare, production control, safety, and environmental monitoring. They often appear in small concentrations. The measurement of trace gases has increasingly become a key technique in those domains. Quartz-enhanced photoacoustic spectroscopy (QEPAS) is a suitable method that can provide the required low detection limits in such applications at comparatively low cost and small size. For mobile implementation, the size of an entire sensor unit matters. In this paper, we present a QEPAS sensor that fits into a standard butterfly package, its characterization, and its application on C H 4 and C O 2 .
- 9 April 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (15) , C55-C59
QEPAS sensor in a butterfly package and its application
Molecular gases are highly relevant in healthcare, production control, safety, and environmental monitoring. They often appear in small concentrations. The measurement of trace gases has increasingly become a key technique in those domains. Quartz-enhanced photoacoustic spectroscopy (QEPAS) is a suitable method that can provide the required low detection limits in such applications at comparatively low cost and small size. For mobile implementation, the size of an entire sensor unit matters. In this paper, we present a QEPAS sensor that fits into a standard butterfly package, its characterization, and its application on C H 4 and C O 2 .
- 1 January 2020
- Published by Optica Publishing Group
- p. LTh3F.2
Carbon Monoxide (CO) Detection based on a Miniaturized QEPAS Sensor
QEPAS is a modem and compact technique suitable for trace gas detection. Currently limitations originate from bulky control-electronics, like lock-in-amplifiers. We report on reducing size and energy of FPGA-based devices with application in CO detection.
- 1 January 2020
- Published by Optica Publishing Group
- p. LTh3F.2
Carbon Monoxide (CO) Detection based on a Miniaturized QEPAS Sensor
QEPAS is a modem and compact technique suitable for trace gas detection. Currently limitations originate from bulky control-electronics, like lock-in-amplifiers. We report on reducing size and energy of FPGA-based devices with application in CO detection.
- 1 January 2020
- Published by Optica Publishing Group
- p. AW3K.4
Miniaturized QEPAS Detector Concept for Methane
QEPAS enables very compact detectors due to the small detection volume. Currently limitations originate from bulky control electronics, like lock-in amplifiers. We report on reducing size and energy of FPGA based devices and their application in methane detection.
- 1 January 2020
- Published by Optica Publishing Group
- p. AW3K.4
Miniaturized QEPAS Detector Concept for Methane
QEPAS enables very compact detectors due to the small detection volume. Currently limitations originate from bulky control electronics, like lock-in amplifiers. We report on reducing size and energy of FPGA based devices and their application in methane detection.
- 18 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 25 (6) , 1-9
Construction and Characterization of External Cavity Diode Lasers Based on a Microelectromechanical System Device
Widely tunable external cavity diode lasers (ECDLs) with a narrow linewidth have become a powerful tool for a variety of applications. The difficulty of the present generation of ECDLs is that they are designed as laboratory instruments and are limited due to their size, high costs, and sensitivity to external influences. In this paper, we present our new ECDL design based on a microelectromechanical system (MEMS) device. This design overcomes the previous drawbacks and offers an outstanding improvement of the most important properties. Moreover, it can be adapted to any wavelength of interest and by using MEMS technology, costs can be reduced.
- 18 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 25 (6) , 1-9
Construction and Characterization of External Cavity Diode Lasers Based on a Microelectromechanical System Device
Widely tunable external cavity diode lasers (ECDLs) with a narrow linewidth have become a powerful tool for a variety of applications. The difficulty of the present generation of ECDLs is that they are designed as laboratory instruments and are limited due to their size, high costs, and sensitivity to external influences. In this paper, we present our new ECDL design based on a microelectromechanical system (MEMS) device. This design overcomes the previous drawbacks and offers an outstanding improvement of the most important properties. Moreover, it can be adapted to any wavelength of interest and by using MEMS technology, costs can be reduced.
- 26 March 2019
- Published by Optica Publishing Group in Applied Optics
- Vol. 58 (10) , C84-C91
Comparison of the spectral excitation behavior of methane according to InP, GaSb, IC, and QC lasers as excitation source by sensor applications
The MIR wavelength regime promises better gas detection possibilities than the NIR or the visible region because of the higher absorbencies simulated by HITRAN. In the MIR region are many important absorption lines of significant gases, which are relevant in healthcare, production supervision, and safety and environmental monitoring. One of those gases is methane. CH4 shows significant variations in absorbance with a maximum at 3.3 μm, which results in low detection limits in the range of low ppm. Interband-cascade- and quantum-cascade-based lasers emit at higher wavelengths, where the absorbencies of methane are higher. The comparison is done by analyzing the performance of two spectroscopy applications: tunable diode laser absorption spectroscopy and quartz-enhanced photoacoustic spectroscopy.
- 26 March 2019
- Published by Optica Publishing Group in Applied Optics
- Vol. 58 (10) , C84-C91
Comparison of the spectral excitation behavior of methane according to InP, GaSb, IC, and QC lasers as excitation source by sensor applications
The MIR wavelength regime promises better gas detection possibilities than the NIR or the visible region because of the higher absorbencies simulated by HITRAN. In the MIR region are many important absorption lines of significant gases, which are relevant in healthcare, production supervision, and safety and environmental monitoring. One of those gases is methane. CH4 shows significant variations in absorbance with a maximum at 3.3 μm, which results in low detection limits in the range of low ppm. Interband-cascade- and quantum-cascade-based lasers emit at higher wavelengths, where the absorbencies of methane are higher. The comparison is done by analyzing the performance of two spectroscopy applications: tunable diode laser absorption spectroscopy and quartz-enhanced photoacoustic spectroscopy.
- 1 January 2019
- Published by Optica Publishing Group
- p. ATh3K.7
High Speed Measurements and Enhancement of QEPAS Sensitivity: Quartz Resonance Frequency Tracking
This study reports on the development of a platform based-on a Field-Programmable Gate Arrays (FPGAs) and suitable for high speed measurements and enhancement of QEPAS sensitivity.
- 1 January 2019
- Published by Optica Publishing Group
- p. ATh3K.7
High Speed Measurements and Enhancement of QEPAS Sensitivity: Quartz Resonance Frequency Tracking
This study reports on the development of a platform based-on a Field-Programmable Gate Arrays (FPGAs) and suitable for high speed measurements and enhancement of QEPAS sensitivity.
- 27 March 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (10) , C120-C127
QEPAS sensor for breath analysis: a behavior of pressure
The measurement of trace gases has increasingly become a key technique in healthcare and other medical applications. Quartz-enhanced photoacoustic spectroscopy (QEPAS) is a suitable method that can provide the required characteristics in such applications for a comparatively low cost and small size. The quantitative detection and a low detection limit are also required by applications. In this paper, we present new results on sensing biomedically relevant gases using the on-beam QEPAS technique with some newly developed tunable high-power single-mode laser diodes based on GaSb material. The data processing and detection limit determination are done by a field programmable gate array device, as well as an automatic measurement of the resonance frequency.
- 27 March 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (10) , C120-C127
QEPAS sensor for breath analysis: a behavior of pressure
The measurement of trace gases has increasingly become a key technique in healthcare and other medical applications. Quartz-enhanced photoacoustic spectroscopy (QEPAS) is a suitable method that can provide the required characteristics in such applications for a comparatively low cost and small size. The quantitative detection and a low detection limit are also required by applications. In this paper, we present new results on sensing biomedically relevant gases using the on-beam QEPAS technique with some newly developed tunable high-power single-mode laser diodes based on GaSb material. The data processing and detection limit determination are done by a field programmable gate array device, as well as an automatic measurement of the resonance frequency.