TITimur E. Imaev

Timur E. Imaev

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Timur E. Imaev has a total of 107 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Radial force of thoracic stent graft: an experimental study of mechanical properties and potential clinical implications

    by T. N. Khafizov, V. V. Kataev, I. M. Enikeev, T. E. Imaev, Т. Н. Хафизов, В. В. Катаев, И. М. Еникеев, Т. Э. Имаев

    Relevance . Thoracic endovascular aortic repair (TEVAR) is rapidly evolving, with expanding clinical indications. These include Stanford type B aortic dissection, aortic arch pathology (non-A, non-B type) managed with endovascular and hybrid techniques (including debranching), as well as aneurysms, penetrating atherosclerotic ulcers, and thoracic aortic ruptures. Objective . To investigate the mechanical properties of different types of stent grafts and to assess their potential clinical implications. Materials and Methods. The study included two types of thoracic endografts available on the available commercially medical device market, differing by graft material: polytetrafluoroethylene (PTFE) and polyester. Considering that oversizing (i.e., selecting an endograft diameter exceeding that of the native vessel) is used during procedural planning to ensure sealing, an experimental assessment of the degree of radial compression of stent grafts was performed using a mechanical press. The force required to deform the devices was evaluated as an indirect indicator of radial force on the aortic wall. Results . Minimal radial force values were observed in the proximal uncovered segments of the endografts, followed by an increase toward the distal direction within the covered portion. The radial force values were recorded in the distal segments of the stent graft with monofilament polyester covering, whereas the lowest values were observed in the proximal region of the PTFE-covered device.Conclusion. Radial load in the covered segments of the stent graft exceeds that in the uncovered proximal portion. This finding supports the need to position the proximal part of the endograft within the least diseased segment of the aorta to reduce the risk of complications.

  • Myocardial electrical dyssynchrony following right ventricular pacing in patients with proximal left bundle branch block after transcatheter aortic valve implantation: data from noninvasive cardiac activation mapping

    by E.V. Kukharchuk, E.M. Rimskaya, S.A. Gaman, T.E. Imaev, S.P. Golitsyn

    Objective. To compare characteristics of myocardial electrical dyssynchrony in patients with long-term right ventricular pacing and iatrogenic left bundle branch block (LBBB) following transcatheter aortic valve implantation (TAVI) using non-invasive activation cardiac mapping (NIAM); to evaluate the effect of pacing electrode location on cardiac activation maps. Material and methods. The study included 50 patients. The main group consisted of 30 patients with implanted pacemakers and right ventricular pacing (RVCP) rate of 100%. The control group consisted of 20 patients with LBBB after TAVI (TAVI-LBBB group). All patients underwent NIAM to construct isochronous maps. We assessed ventricular endo- and epicardium activation time (AT), activation time difference (ATD), localization of late activation points (LAPs), and conduction block lines (CBLs). In the RVCP group, additional analysis of activation map formation was performed with different stimulating electrode positions (apical, middle third of interventricular septum, basal). Results. The RVCP group was characterized by more severe electrical dyssynchrony: QRS duration 157 versus 140 ms (p=0.001), interventricular activation delay on the epicardium 17.8 versus 12 ms (p<0.001). Ventricular myocardial activation maps in the RVCP group were highly variable. LAP zone typical for LBBB was detected in only 30% of patients (versus 90% in the TAVI-LBBB group), and conduction block line was absent in 20% of cases. Full compliance with LBBB criteria according to NIAM data was found in only 10% of patients with RVCP. Within the RVCP group, electrode position did not affect topography of LAP and CBL. However, apical pacing resulted in the shortest endocardial interventricular activation delay (18 ms) compared to basal and mid-positions (41 ms and 50 ms; p=0.035, respectively). Conclusion. Ventricular electrical activation during cardiac pacing is not equivalent to that in LBBB after TAVI. These processes are characterized by more severe electrical dyssynchrony and variability of activation maps. Apical electrode position, despite small endocardial conduction delay, creates effect of “pseudosynchrony of onset” followed by significant slowing of impulse propagation across the epicardium. These differences indicate that ventricular pacing forms independent pathophysiological model of ventricular myocardial electrical dyssynchrony distinct from that in proximal LBBB after TAVI.

  • Histological changes of the aortic wall in the area of the proximal neck of an aneurysm upon rupture

    by T.N. Khafizov, V.V. Kataev, A.M. Shumkin, S.V. Shchekin, B.I. Zagidullin, V.R. Manylova, R.R. Khafizov, T.E. Imaev

  • Transcatheter edge-to-edge mitral valve repair using G4 clips in the treatment of patients with central and noncentral severe primary mitral regurgitation

    by M.I. Makeev, M.A. Saidova, I.V. Kuchin, A.E. Komlev, T.E. Imaev

    Objective. To evaluate in-hospital outcomes in patients with central and noncentral severe primary mitral regurgitation (PMR) after transcatheter edge-to-edge mitral valve repair (TMVR). Material and methods. The study included 62 high risk patients with severe symptomatic PMR: group 1 — 45 (72.6%) patients with central mitral regurgitation (MR), group 2 — 17 (27.4%) patients with noncentral MR. Mean age was 75 [68; 83] years, and 58.1% of patients were men. MitraClip G4 devices were implanted. Left ventricular (LV) volumetric dimensions, ejection fraction, and central hemodynamic parameters were assessed using echocardiography at baseline and 4-5 days after intervention. A detailed quantitative analysis of MR was performed, and mean mitral valve pressure gradient was calculated. Results. In early postoperative period, MR significantly reduced in both groups (p<0.001). Technical success rate was comparable in both cohorts (95.6% in central MR and 82.4% in noncentral MR, p=0.12). Hemodynamic efficacy of TMVR was more obvious in the 1st group as evidenced left ventricular end-diastolic volume (LVEDV) and LV central hemodynamic parameters. LVEDV decreased in the first group from 140 [103; 161] to 113 [87; 140] ml (p<0.001), in the second group — from 118 [94; 170] to 110 [83; 166] ml (p=0.015). Chordae tendineae rupture did not affect technical success of TMVR, but was associated with implantation of two clips (p=0.03). The number of clips did not differ between patients with central (1.56) and noncentral (1.53) MR (p=0.88). TMVR increased mean mitral valve pressure gradient in both cohorts of patients. However, this parameter was similar in postoperative period in both groups with increased number of clips. Conclusion. Transcatheter edge-to-edge mitral valve repair using G4 clips is an effective correction of central and noncentral severe primary mitral regurgitation.

  • Heterotopic bicaval implantation of transcatheter system for the treatment of severe tricuspid regurgitation

    by T.E. Imaev, A.Z. Khulamkhanova, A.E. Komlev, M.A. Saidova, P.M. Lepilin, A.S. Kolegaev, I.V. Kuchin, D.V. Salichkin

    The authors describe the first case of heterotopic bicaval implantation of transcatheter valve system in Russia for correction of severe tricuspid regurgitation in a patient with extremely high surgical risk and contraindication for redo surgery under cardiopulmonary bypass. The patient did not meet anatomical criteria for transcatheter edge-to-edge tricuspid valve repair. This case demonstrates the effectiveness of heterotopic bicaval implantation for tricuspid valve disease in high-risk patient with better control of chronic heart failure and positive reverse right ventricular remodeling over a 12-month follow-up.

  • Surgical treatment of a patient with severe aortic stenosis and hereditary factor XI deficiency

    by E.V. Kozlova, O.S. Bulkina, N.I. Zozulya, V.V. Lopukhova, A.E. Komlev, A.S. Kolegaev, N.S. Maslennikova, T.E. Imaev, Yu.A. Karpov

    Surgery is the only effective treatment for severe aortic stenosis. Previously, valve replacement was only performed under cardiopulmonary bypass. Minimally invasive transcatheter aortic valve implantation (TAVI) is currently available for high-risk patients, including elderly ones. However, there is a risk of hemorrhagic complications even in minimally invasive procedures. In general population, the incidence of bleeding requiring transfusion after TAVI is 6—9%. The risk of bleeding is even higher in patients with clotting disorders. We present successful management of a patient with hereditary factor XI deficiency who required surgical treatment for severe symptomatic aortic stenosis.

  • Open Access

    Cardiology and cardiac surgery – a symbiosis of successful treatment of heart failure

    by Tatiana M. Uskach, Valeria A. Amanatova, Darin F. Ardus, Oleg V. Sapelnikov, Timur E. Imaev, Sergey N. Tereshchenko, Терещенко Сергей Николаевич

    Currently, the proportion of patients with heart failure is progressively increasing. Despite the progress in drug therapy, additional manipulations are often necessary to correct cardiovascular pathology in these patients. Given the high comorbidity, the use of classical surgical techniques is impossible in some cases. Implantation of high-tech devices, catheter ablation of arrhythmogenic areas, transcatheter mitral valve plastic surgery are minimally invasive surgical methods. Proper interaction between a cardiologist and a cardiovascular surgeon allows for the maximum personalization of the approach to the treatment of each patient, achieving maximum results with significantly reduced risks.


  • Open Access

    One-year results of transcatheter implantation using the "valve-in-valve" technique for mitral valve degeneration

    by A. Z. Khulamkhanova, T. E. Imaev, I. V. Sergienko, A. E. Komlev, P. M. Lepilin, A. S. Kolegaev

    Objective . To evaluate the efficacy and safety of this method in patients with severe dysfunction of the mitral valve prosthesis. Materials and methods . From May 2015 to March 2024, 25 patients with mitral valve prosthesis failure due to degenerative changes were treated in the Department of Cardiovascular Surgery. The patients underwent transapical implantation of the prosthesis in the mitral position using the valve-in-valve technique using the Edwards Sapien XT (Edwards Lifesciences USA – California) and Myval (Meril Life Sciences, Vapi, India) valve systems via transfemoral access. Results .Implantation was successful in all cases, no conversion to open intervention was registered. Comparison of preoperative and postoperative echocardiographic parameters revealed a statistically significant decrease in the level of mean and maximum transprosthetic pressure gradients (12 [9.5; 16.2] versus 6 [4.7; 6] and 29.5 [22; 33.5] versus 12 [10; 14.75], respectively, pConclusion . Transcatheter implantation in the mitral position using the "valvein-valve" technique for the treatment of patients with high surgical risk with degeneration of the mitral valve prosthesis is an effective and safe technique. An important stage in this intervention is careful preoperative planning with the selection of a prosthesis of the required size and assessment of an unfavorable clinical outcome depending on the anatomical features of the patient.

  • Open Access

    Change in the electrical axis of the heart during inspiration as an additional sign of the presence of pulmonary hypertension in patients with aortic stenosis

    by T. A. Sakhnova, E. V. Blinova, A. E. Komlev, M. A. Saidova, T. V. Martynyuk, T. E. Imaev, D. V. Drozdov

    The aim of the study was to evaluate the possibility of using an inspiratory electrocardiogram to detect pulmonary hypertension (PH) in patients with severe aortic stenosis (AS). Materials and methods. The study included 166 patients with severe AS aged 73±8 years. Pulmonary artery systolic pressure (PASP) was determined by echocardiography. The position of the heart electrical axis (HEA) was assessed during quiet breathing (HEAq) and deep inspiration (HEAin). Results. In 93 (56%) patients, PASP was <35 mmHg, in 45 (27%) from 35 to 44 mmHg, and in 28 (17%) patients ≥45 mmHg. In groups with PASP<45 mmHg, on inspiration, there was a shift in the HEA to the right of the initial value (p<0.0001), and at PASP ≥45 mm Hg, these changes did not reach statistical significance (p = 0.05). In the ROC analysis, the HEAq, HEAin, and the difference between them made it possible to separate the groups of patients with PASP<35 mm Hg and ≥35 mm Hg. The optimal threshold values were HEAq ≤-19° (sensitivity 34%, specificity 85%), HEAin ≤16° (sensitivity 49%, specificity 76%), and the difference between HEAin and HEAq <18° (sensitivity 70%, specificity 66%). Only the difference between the HEAq and HEAin with an optimal threshold value of <16° (sensitivity 79%, specificity 60%) allowed us to separate the groups of patients with PASP<45 mm Hg and ≥45 mm Hg. Conclusions. In patients with severe AS, there is a shift of the HEA to the right from the initial value during inhalation, which is most pronounced in patients without PH. A lesser degree of shift of the HEA to the right from the initial value during inhalation allowed us to distinguish both the patients with PASP ≥35 mmHg and ≥45 mmHg with a sensitivity of 70-79% and a specificity of 60-66%.

  • Open Access

    Myocardial work in electrical dyssynchrony due to left bundle branch block

    by E. M. Rimskaya, S. V. Dobrovolskaya, E. V. Kukharchuk, S. Yu. Kashtanova, N. A. Mironova, Г. С. Тарасовский, A. E. Komlev, T. E. Imaev, M. A. Saidova, S. P. Golitsyn

    Aim. To evaluate myocardial function in different groups of patients with left bundle branch block (LBBB) and the LBBB "model" — right ventricular pacing (RVP).Material and methods. Global longitudinal strain (GLS) and myocardial function parameters, such as global constructive work (GCW), global wasted work (GWW), global work index (GWI), and global work efficiency (GWE), were measured in 25 patients with dilated cardiomyopathy (DCM) and LBBB (DCM-LBBB group), 20 patients with DCM and a narrow QRS complex (DCM-nonLBBB group), 15 patients with LBBB developed after transcatheter aortic valve implantation (TAVI LBBB group), 12 patients with idiopathic LBBB (I-LBBB group), 27 patients with permanent RVP, and 10 healthy volunteers (HVs). The segments with maximum and minimum GWI were determined in all patients.Results. The GLS, GWI and GCW values were comparable in the I-LBBB and RVP groups, and were significantly lower in the TAVI-LBBB and both DCM groups than in HVs (p=0,049, 0,006, 0,025; pConclusion. Despite the fact that all patients with an electrical activation pattern corresponding to LBBB are characterized by significant wasted work, its contribution to the global myocardial work is significant only in patients with DCM. Lost work does not lead to a decrease in constructive work in patients with I-LBBB and RVP and normal left ventricular systolic function.