William Wynell-Mayow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
William Wynell-Mayow has a total of 174 co-authors. Here are the top co-authors by number of shared publications:
- Abdus Samee Wasim1 shared publication
Abhinav Singh
Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK
1 shared publication- Abhinav Singh
Oxford University
1 shared publication - Adam Smith1 shared publication
- Adam Stoneham
Department of Orthopaedic Surgery, Northshore Hospital, Auckland, New Zealand
1 shared publication - Alastair Konarski
Department of Orthopaedic Surgery and Musculoskeletal Medicine, University of Otago, Christchurch, New Zealand
1 shared publication
Latest Publications
- Open Access
- 11 November 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 6 (11) , 1425-1435
Interobserver reliability of Coronal Plane Alignment of the Knee (CPAK) phenotype classification
Aims: Coronal Plane Alignment of the Knee (CPAK) phenotyping is gaining momentum in research and clinical practice to understand individualized knee alignments and predict knee balance in total knee arthroplasty (TKA). The nine CPAK classes are based on joint line obliquity (JLO) and arithmetic hip-knee-ankle angle (aHKA), which are calculated using the medial proximal tibial angle (MPTA) and lateral distal femoral angle (LDFA). This study aims to assess CPAK classification reproducibility, and analyze what level of angular error is associated with CPAK misclassification. Methods: Two readers labelled 75 long-leg radiographs (LLRs) from the Osteoarthritis Initiative database for analyses of CPAK inter-reader reproducibility. A single reader then labelled and classified phenotypes for an aggregate total of 1,128 LLRs. Finally, Monte Carlo simulations were run based on 1,128-patient phenotype distribution and the inter-reader reproducibility statistics to understand how CPAK agreement rates were affected by the reproducibility of MPTA and LDFA measurements. Results: There was excellent reproducibility in MPTA and LDFA measurements (mean absolute error: 0.41°/0.71°; and intraclass correlation coefficient: 0.96°/0.91°, respectively). These small angular deviations led to one-in-five disagreement in CPAK classification (20.0%; 95% CI 10.9% to 29.1%). An aHKA mean absolute error of < 0.1°, which is potentially unattainable, would be required to reduce inter-reader CPAK disagreement to below 95%. Conclusion: CPAK phenotyping from long-leg radiographs may result in clinically significant rates of misclassification. CT imaging may improve reliability, particularly in cases where aHKA and JLO are near to discriminatory values. Cite this article: Bone Jt Open 2025;6(11):1425–1435.
- 11 November 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 6 (11) , 1425-1435
Open AccessInterobserver reliability of Coronal Plane Alignment of the Knee (CPAK) phenotype classification
Aims: Coronal Plane Alignment of the Knee (CPAK) phenotyping is gaining momentum in research and clinical practice to understand individualized knee alignments and predict knee balance in total knee arthroplasty (TKA). The nine CPAK classes are based on joint line obliquity (JLO) and arithmetic hip-knee-ankle angle (aHKA), which are calculated using the medial proximal tibial angle (MPTA) and lateral distal femoral angle (LDFA). This study aims to assess CPAK classification reproducibility, and analyze what level of angular error is associated with CPAK misclassification. Methods: Two readers labelled 75 long-leg radiographs (LLRs) from the Osteoarthritis Initiative database for analyses of CPAK inter-reader reproducibility. A single reader then labelled and classified phenotypes for an aggregate total of 1,128 LLRs. Finally, Monte Carlo simulations were run based on 1,128-patient phenotype distribution and the inter-reader reproducibility statistics to understand how CPAK agreement rates were affected by the reproducibility of MPTA and LDFA measurements. Results: There was excellent reproducibility in MPTA and LDFA measurements (mean absolute error: 0.41°/0.71°; and intraclass correlation coefficient: 0.96°/0.91°, respectively). These small angular deviations led to one-in-five disagreement in CPAK classification (20.0%; 95% CI 10.9% to 29.1%). An aHKA mean absolute error of < 0.1°, which is potentially unattainable, would be required to reduce inter-reader CPAK disagreement to below 95%. Conclusion: CPAK phenotyping from long-leg radiographs may result in clinically significant rates of misclassification. CT imaging may improve reliability, particularly in cases where aHKA and JLO are near to discriminatory values. Cite this article: Bone Jt Open 2025;6(11):1425–1435.
- 1 December 2021
- Published by Elsevier in The Surgeon
- Vol. 19 (6) , e331-e337
Collaborative Overview of coronaVIrus impact on ORTHopaedic training in the UK (COVI - ORTH UK)
- 1 December 2021
- Published by Elsevier in The Surgeon
- Vol. 19 (6) , e331-e337
Collaborative Overview of coronaVIrus impact on ORTHopaedic training in the UK (COVI - ORTH UK)
- Open Access
- 25 November 2021
- Published by Elsevier in JSES International
- Vol. 6 (3) , 447-453
A lower critical coracoid process angle is associated with type-B osteoarthritis: a radiological study of normal and diseased shoulders
- 25 November 2021
- Published by Elsevier in JSES International
- Vol. 6 (3) , 447-453
Open AccessA lower critical coracoid process angle is associated with type-B osteoarthritis: a radiological study of normal and diseased shoulders
- 14 March 2018
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 28 (6) , 1177-1182
Much ado about nothing: the effect of tourniquet time on an accelerated rehabilitation programme following total knee replacement (TKR)
Background The WHO includes osteoarthritis as a disease of priority, owing to its significant impact on quality of life, and globally increasing prevalence. Hospital budgets are under pressure to ration knee replacements and shorten inpatient stays. Prolonged tourniquet application has been hypothesised to extend recovery through pain and reduced mobility. Patients and methods A total of 123 elective total knee replacements meeting inclusion criteria took place from July 2015 to October 2017 at the Royal Free Hospital. Cases were standardised by method of TKR, implant, physiotherapy and analgesic regime according to the trust Enhanced Recovery after Surgery pathway. Tourniquet time was compared to length-of-stay post-operatively and total opioid analgesia requirement over 24 h. Results Median tourniquet time overall was 74 min and was decreased year-on-year from 108 to 60 min (p = 0.000). Inpatient median length-of-stay was 5 days and did not decrease (p = 0.667). Increased tourniquet time was not associated with longer length-of-stay but in fact shorter (p = 0.03199), likely due to this confounding temporal trend. Increased tourniquet time was not associated with increased opioid requirement (p = 0.78591). No association was found between tourniquet time and other complications including DVT and infection. Conclusions Our study finds no evidence that reductions in tourniquet time in TKR improve recovery including length-of-stay or opioid requirement. This clinical data is expected to augment PROMs collected by the National Joint Registry.
- 14 March 2018
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 28 (6) , 1177-1182
Much ado about nothing: the effect of tourniquet time on an accelerated rehabilitation programme following total knee replacement (TKR)
Background The WHO includes osteoarthritis as a disease of priority, owing to its significant impact on quality of life, and globally increasing prevalence. Hospital budgets are under pressure to ration knee replacements and shorten inpatient stays. Prolonged tourniquet application has been hypothesised to extend recovery through pain and reduced mobility. Patients and methods A total of 123 elective total knee replacements meeting inclusion criteria took place from July 2015 to October 2017 at the Royal Free Hospital. Cases were standardised by method of TKR, implant, physiotherapy and analgesic regime according to the trust Enhanced Recovery after Surgery pathway. Tourniquet time was compared to length-of-stay post-operatively and total opioid analgesia requirement over 24 h. Results Median tourniquet time overall was 74 min and was decreased year-on-year from 108 to 60 min (p = 0.000). Inpatient median length-of-stay was 5 days and did not decrease (p = 0.667). Increased tourniquet time was not associated with longer length-of-stay but in fact shorter (p = 0.03199), likely due to this confounding temporal trend. Increased tourniquet time was not associated with increased opioid requirement (p = 0.78591). No association was found between tourniquet time and other complications including DVT and infection. Conclusions Our study finds no evidence that reductions in tourniquet time in TKR improve recovery including length-of-stay or opioid requirement. This clinical data is expected to augment PROMs collected by the National Joint Registry.