KAKiran Kumar Amireddy

Kiran Kumar Amireddy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kiran Kumar Amireddy has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Krishnan Balasubramaniam

    Centre for Non-Destructive Evaluation, Indian Institute of Technology Madras, Chennai 600036, India

    4 shared publications
  • Prabhu Rajagopal

    Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, India

    4 shared publications
  • P. Prabhakar Reddy

    Department of Mechanical Engineering, Chaitanya Bharthi Institute of Technology

    2 shared publications
  • Venkata Sushma Chinta

    Department of Mechanical Engineering Chaitanya Bharathi Institute of Technology Gandipet Hyderabad Telangana India

    2 shared publications
  • C. Nagendranatha Reddy

    Department of Biotechnology, Chaitanya Bharthi Institute of Technology

    1 shared publication
  • Ch. Indira Priyadarsini

    Department of Mechanical Engineering, Chaitanya Bharathi Institute of Technology (Autonomous), Hyderabad-500075, Telangana, India

    1 shared publication

Latest Publications

  • Open Access

    Continuous monitoring biosensors for advanced healthcare and environmental applications: challenges, material innovations and future directions

    by Kiran Kumar Amireddy, P. V. R. Ravindra Reddy, C. Nagendranatha Reddy, P. Prabhakar Reddy

    This review critically discusses the development of continuous monitoring biosensors and the technological developments that have facilitated the transition from one-off or periodic measurement sensors to longer-term, connected and autonomous sensors. One hundred forty-four publications were analysed using a bibliometric approach, giving a map of the field that illustrates its growth, multidisciplinary aspects, technological development and key application areas. Electrochemical and optical transduction strategies are discussed in a systematic manner along with the advanced functional materials such as carbon nanotubes, graphene quantum dots, MXenes, covalent organic frameworks, molecularly imprinted polymers, functional polymers, hydrogels and chiral composites. Specific focus is placed on the use of these materials as an enhancement of charge transfer, analyte accessibility, selectivity, reversible recognition, antifouling behaviour, mechanical flexibility, signal stability and sensor regeneration. Architectures for wearable, implantable, biodegradable and self-powered are presented for continuous monitoring of clinically relevant biomarkers and metabolites, and platforms for environmental monitoring of waterborne pollutants, heavy metals and antibiotics, pathogens and other contaminants are explored. The review also examines the incorporation of microfluidics, wireless communication, artificial intelligence/machine learning, edge and cloud computing and Internet of Things technologies, which show the evolution towards multiplexed, connected and closed-loop biosensing systems. In all of these areas, analysis reveals that barriers to translation include sensor regeneration, biofouling, signal drift, matrix interference, calibration, energy requirements, biocompatibility, device integration, scalability, cybersecurity, regulatory compliance, and limited clinical/field validation. Notably, analytical parameters, including sensitivity and limit of detection, are demonstrated to be inadequate to assess deployment readiness, and long-term stability, matrix tolerance, reproducibility and real-world validation are all required. The areas identified for future direction include regenerative and antifouling sensing interfaces, multimodal and self-powered platforms, physiomimetic and minimally invasive architectures, AI-enabled signal interpretation, standardized performance metrics, scalable manufacturing, and rigorous clinical and environmental validation. In general, the review highlights advanced materials, biorecognition, device engineering, energy management, digital connectivity, and data analytics as the critical enabler for reliable continuous biosensing for personalized healthcare and environmental monitoring applications.


  • Open Access

    Advanced Ultrasonic Characterization of Areca Nut Natural Fiber Reinforced Composite Balustrades

    by Kiran Kumar Amireddy, P. Prabhakar Reddy, Venkata Sushma Chinta

    Balustrades are key functional elements in architecture for improved protection and add aesthetic value to various types of buildings. Industrialization allows a wide variety of materials in preparation of Balustrades for improved safety and style, but disposal of these composites (non-biodegradable) after their service life is a challenging task for materials engineers. Hence, researchers are now concentrating on natural fiber reinforced composites as an alternate solution for sustainability and eco-friendliness without compromising their strength and functionality. In this paper, we demonstrate the use of Areca nut natural fiber reinforced composites for the preparation of composite laminates as an application of building blocks as Balustrades and also explain the investigation of these Balustrades for their quality assurance. By using the Nonlinear Resonance Ultrasonic inspection method (NRUS), we demonstrate the finding of defects like cracks, porosity, density variation, delamination, and their location in the Areca nut fibre reinforced composite Balustrades. Also, we demonstrate the effect of the nonlinear coefficient with delamination location in the multi-layered composite sheet. Further, the same nonlinear coefficient variation occurs with the presence of defect types like cracks, porosity, etc., in the composite laminates.

  • Open Access

    Ultrasonic Evaluation of Paint Canisters

    by Kiran Kumar Amireddy, S. Solomon Raj, Venkata Sushma Chinta, Ch. Indira Priyadarsini, G. Laxmaiah

    Canisters are used to store liquids such as oil, paint, liquefied glue, and so on. When a customer buys a canister of liquid, they expect the contents to be in pristine condition. The contents of the canister may become defective due to errors in manufacture, transportation, or unfavourable climatic conditions, and the unsuspecting client discovers this after breaking the seal. The vendor will not take the defective goods back after the seal has been broken. One such process that can be used to determine that the products in the canisters are in usable condition is non-destructive testing using ultrasonics. In this method, a transducer is used, which has a transmitter and a receiver. The transmitter is placed on one side of the canister, and the receiver is placed exactly opposite on the other side. Using this, the time taken for the waves to propagate from emitter to receiver (time of flight) is noted and compared with that of standard values. This process allows us to determine whether the contents of the canisters are in good condition or not. The measurements are carried out at three different locations, i.e., the top, middle, and bottom of the canister, and time of flight (TOF) values are recorded. If the content inside the canister is in a liquid state, the TOF is observed at about 54±0.5 microseconds. Due to poor weather conditions, mismanufacturing, or mishandling in transportation, if the canister’s contents have any air pockets, then the contents react and solidify. For this case, the TOF is about 40 ±0.5 microseconds only. A difference of 14 microseconds was observed when the content of the canister changed from liquid sate to solid. This allows us to determine the contents of the canister, without opening the seal.

  • Porous metamaterials for deep sub-wavelength ultrasonic imaging

    by Kiran Kumar Amireddy, Krishnan Balasubramaniam, Prabhu Rajagopal

    This paper reports the application of a porous medium as an aperiodic metamaterial lens for ultrasonic imaging in the context of nondestructive evaluation and non-invasive diagnostics. Experimental results are presented, demonstrating a deep sub-wavelength imaging down to 1/36th of the operating wavelength, which is the highest resolution demonstrated worldwide using bulk ultrasound. The improvement in the resolution is shown to be linked to aperiodicity overcoming the Wood anomaly, which sets limits on wave transmission by holey structured lenses.


  • Open Access

    Deep subwavelength ultrasonic imaging using optimized holey structured metamaterials

    by Kiran Kumar Amireddy, Krishnan Balasubramaniam, Prabhu Rajagopal

    This paper reports the experimental demonstration of deep subwavelength ultrasonic imaging of defects in metallic samples with a feature size of λ/25 using holey-structured metamaterial lenses. Optimal dimensions of the metamaterial’s geometric parameters are determined using numerical simulation and the physics of wave propagation through holey lenses. The paper also shows how the extraordinary transmission capacity of holey structured metamaterials comes about by the coupling of higher frequencies in the incident ultrasonic wave field to resonant modes of the lens.


  • Sub-wavelength resolution of cracks in metallic materials

    by Kiran Kumar Amireddy, Prabhu Rajagopal, Krishnan Balasubramaniam

    In recent years, various types of acoustic metamaterials have been proposed with capabilities for overcoming the diffraction limit. However, typically such developments only consider the acoustic regime or imaging in liquid media. In this paper we show the application of a holey structured metamaterial lens for sub-wavelength imaging of defects in a metallic sample, in the ultrasonic regime. Finite Element (FE) simulations are used to study longitudinal wave interaction with ideal cracks in isotropic elastic materials. Holey-structured meta-lenses are then used to transmit the scattered waves. We present a super resolution of λ/7 with a subwavelength crack in an aluminium sample, which to the best of our knowledge this is the highest resolution achieved in the ultrasonic regime.

  • Holey-structured metamaterial lens for subwavelength resolution in ultrasonic characterization of metallic components

    by Kiran Kumar Amireddy, Krishnan Balasubramaniam, Prabhu Rajagopal

    This paper presents the implementation of holey structured metamaterial lens for ultrasonic characterization of subwavelength subsurface defects in metallic components. Experimental results are presented, demonstrating ultrasound-based resolution of side drilled through-holes spaced (λ/5) in an aluminum block. Numerical simulation is then used to investigate the parameters that can help improve the resolution performance of the metamaterial lens, particularly, the addition of end-conditions. This work has important implications for higher resolution ultrasonic imaging in the context of practical non-destructive imaging and non-invasive material diagnostics.