Lídia Carvalho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lídia Carvalho has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Rogerio Nunes Nogueira
Instituto de Telecomunicações, University of Aveiro, Campus Universitário de Santiago, 3810-193 Aveiro, Portugal
9 shared publications - Joao Lemos Pinto
Department of Physics and I3N, University of Aveiro, Campus de Santiago, 3810-193 Aveiro, Portugal
8 shared publications - Jean Carlos Cardozo da Silva
Universidade Tecnológica Federal do Paraná
5 shared publications Hypolito J. Kalinowski
Federal Univ. of Technology of Paraná (Brazil)
4 shared publications- Orlando Frazão
INESC TEC—Institute for Systems and Computer Engineering, Technology and Science, 4169-007 Porto, Portugal
4 shared publications - Paulo Roriz
INESC Porto (Portugal)
4 shared publications
Latest Publications
- 15 June 2022
- Published by Institution of Engineering and Technology (IET) in IET Conference Proceedings
- Vol. 2022 (3) , 636-640
Electrical vehicles - grid integration issues and solutions
- 15 June 2022
- Published by Institution of Engineering and Technology (IET) in IET Conference Proceedings
- Vol. 2022 (3) , 636-640
Electrical vehicles - grid integration issues and solutions
- 5 November 2019
- Published by Rational Publication in Journal of Mechanical Engineering and Biomechanics
- Vol. 4 (2) , 52-61
Multiscale remodeling model for orthodontic movement
- 5 November 2019
- Published by Rational Publication in Journal of Mechanical Engineering and Biomechanics
- Vol. 4 (2) , 52-61
Multiscale remodeling model for orthodontic movement
- 20 May 2016
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 38 (9) , 904-910
Influence of different mechanical stimuli in a multi-scale mechanobiological isotropic model for bone remodelling
This work represents a study of a mathematical model that describes the biological response to different mechanical stimuli in a cellular dynamics model for bone remodelling. The biological system discussed herein consists of three specialised cellular types, responsive osteoblasts, active osteoblasts and osteoclasts, three types of signalling molecules, transforming growth factor beta (TGF-β), receptor activator of nuclear factor kappa-b ligand (RANKL) and osteoprotegerin (OPG) and the parathyroid hormone (PTH). Three proposals for mechanical stimuli were tested: strain energy density (SED), hydrostatic and deviatoric parts of SED. The model was tested in a two-dimensional geometry of a standard human femur. The spatial discretization was performed by the finite element method while the temporal evolution of the variables was calculated by the 4th order Runge-Kutta method. The obtained results represent the temporal evolution of the apparent density distribution and the mean apparent density and thickness for the cortical bone after 600 days of remodelling simulation. The main contributions of this paper are the coupling of mechanical and biological models and the exploration of how the different mechanical stimuli affect the cellular activity in different types of physical activities. The results revealed that hydrostatic SED stimulus was able to form more cortical bone than deviatoric SED and total SED stimuli. The computational model confirms how different mechanical stimuli can impact in the balance of bone homeostasis.
- 20 May 2016
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 38 (9) , 904-910
Influence of different mechanical stimuli in a multi-scale mechanobiological isotropic model for bone remodelling
This work represents a study of a mathematical model that describes the biological response to different mechanical stimuli in a cellular dynamics model for bone remodelling. The biological system discussed herein consists of three specialised cellular types, responsive osteoblasts, active osteoblasts and osteoclasts, three types of signalling molecules, transforming growth factor beta (TGF-β), receptor activator of nuclear factor kappa-b ligand (RANKL) and osteoprotegerin (OPG) and the parathyroid hormone (PTH). Three proposals for mechanical stimuli were tested: strain energy density (SED), hydrostatic and deviatoric parts of SED. The model was tested in a two-dimensional geometry of a standard human femur. The spatial discretization was performed by the finite element method while the temporal evolution of the variables was calculated by the 4th order Runge-Kutta method. The obtained results represent the temporal evolution of the apparent density distribution and the mean apparent density and thickness for the cortical bone after 600 days of remodelling simulation. The main contributions of this paper are the coupling of mechanical and biological models and the exploration of how the different mechanical stimuli affect the cellular activity in different types of physical activities. The results revealed that hydrostatic SED stimulus was able to form more cortical bone than deviatoric SED and total SED stimuli. The computational model confirms how different mechanical stimuli can impact in the balance of bone homeostasis.
- Open Access
- 24 November 2015
- Published by MDPI AG in Applied Sciences
- Vol. 5 (4) , 1350-1378
New Trends in Dental Biomechanics with Photonics Technologies
Engineering techniques used to evaluate strain-stress fields, materials’ mechanical properties, and load transfer mechanisms, among others, are useful tools in the study of biomechanical applications. These engineering tools, as experimental and numerical ones, were imported to biomechanics, in particular in dental biomechanics, a few decades ago. Several experimental techniques have been used in dental biomechanics, like photoelasticity, ESPI (Electronic Speckle Pattern Interferometry), strain gages, and other kinds of transducers. However, these techniques have some limitations. For instance, photoelasticity and ESPI give the overall field pattern of the strain, showing the stress-strain concentration points. These methods cannot give an accurate measurement at all points. On the contrary, strain gages can be used to perform local measurements. However, as they use electrical resistances, their use is limited to perform in vivo measurements. Optical fiber sensors have already been used in dentistry, for diagnostic and therapeutic purposes, and in dental biomechanics studies. Lasers have also been used in clinical dentistry for a few decades. Other optical technologies, like optical coherence tomography (OCT), became suitable for dental practice and nowadays it is perhaps one that has had more development in dentristry, along with lasers.
- 24 November 2015
- Published by MDPI AG in Applied Sciences
- Vol. 5 (4) , 1350-1378
Open AccessNew Trends in Dental Biomechanics with Photonics Technologies
Engineering techniques used to evaluate strain-stress fields, materials’ mechanical properties, and load transfer mechanisms, among others, are useful tools in the study of biomechanical applications. These engineering tools, as experimental and numerical ones, were imported to biomechanics, in particular in dental biomechanics, a few decades ago. Several experimental techniques have been used in dental biomechanics, like photoelasticity, ESPI (Electronic Speckle Pattern Interferometry), strain gages, and other kinds of transducers. However, these techniques have some limitations. For instance, photoelasticity and ESPI give the overall field pattern of the strain, showing the stress-strain concentration points. These methods cannot give an accurate measurement at all points. On the contrary, strain gages can be used to perform local measurements. However, as they use electrical resistances, their use is limited to perform in vivo measurements. Optical fiber sensors have already been used in dentistry, for diagnostic and therapeutic purposes, and in dental biomechanics studies. Lasers have also been used in clinical dentistry for a few decades. Other optical technologies, like optical coherence tomography (OCT), became suitable for dental practice and nowadays it is perhaps one that has had more development in dentristry, along with lasers.
- Open Access
- 28 April 2015
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 605
Evaluation of the performance of orthodontic devices using FBG sensors
- 28 April 2015
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 605
Open AccessEvaluation of the performance of orthodontic devices using FBG sensors
- 2 June 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9157, 91571U-91571U-4
Fabry-Perot cavity hydrostatic pressure sensors
- 2 June 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9157, 91571U-91571U-4
Fabry-Perot cavity hydrostatic pressure sensors
- 1 April 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (6) , 1251-1261
From conventional sensors to fibre optic sensors for strain and force measurements in biomechanics applications: A review
- 1 April 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (6) , 1251-1261
From conventional sensors to fibre optic sensors for strain and force measurements in biomechanics applications: A review
- 1 June 2011
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 26 (10) , 4046-4052
In the trail of a new bio-sensor for measuring strain in bone: Osteoblastic biocompatibility
- 1 June 2011
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 26 (10) , 4046-4052
In the trail of a new bio-sensor for measuring strain in bone: Osteoblastic biocompatibility
- 21 May 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8001, 800134-800134-6
Evaluation of the efficacy and influence of the decontamination and sterilization of FBGs exposed to S. aureus and E. coli
The FBGs (Fibre Bragg Grating) are adequate sensors for measuring strain in biomedical applications. This work evaluates the efficacy of some products and processes, which are used for the decontamination and sterilization of these sensors. Fibre optic samples, partially stripped of the primary coating, were contaminated by E. coli and S. aureus and suffered decontamination processes by autoclave heating, immersion in ethylene oxide, sodium hypochlorite, chloramine T or peracetic acid and illumination ultra-violet radiation. After each process fibre samples were removed, washed in sterile saline and placed individually in BHI broth tubes. Tubes that showed turbidity of the BHI broth were considered positive. The sterilization practices by heating and immersionand avoided the formation of bacteria colonies, whereas illumination processes were not effective to avoid the bacteria colony growth.
- 21 May 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8001, 800134-800134-6
Evaluation of the efficacy and influence of the decontamination and sterilization of FBGs exposed to S. aureus and E. coli
The FBGs (Fibre Bragg Grating) are adequate sensors for measuring strain in biomedical applications. This work evaluates the efficacy of some products and processes, which are used for the decontamination and sterilization of these sensors. Fibre optic samples, partially stripped of the primary coating, were contaminated by E. coli and S. aureus and suffered decontamination processes by autoclave heating, immersion in ethylene oxide, sodium hypochlorite, chloramine T or peracetic acid and illumination ultra-violet radiation. After each process fibre samples were removed, washed in sterile saline and placed individually in BHI broth tubes. Tubes that showed turbidity of the BHI broth were considered positive. The sterilization practices by heating and immersionand avoided the formation of bacteria colonies, whereas illumination processes were not effective to avoid the bacteria colony growth.
- Open Access
- 1 January 2011
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 30 (5) , 700-706
Characterization of different water/powder ratios of dental gypsum using fiber Bragg grating sensors
The impact of five different water/powder (w/p) ratios in the characterization of high strength dental stone was evaluated, since the recommendations of the gypsum’ manufacturers are not always correctly followed by the dental prosthesis technicians. Fiber Bragg grating (FBG) sensors were used to measure the setting expansion and temperature variation which occurred during the setting reaction for each w/p ratio, as well as the thermal expansion coefficient. Thick mixtures with low w/p ratios had more crystals impinging upon each other during crystal growth, resulting in more expansion and more heat released. This thermal behavior was only achieved to w/p ratios within the manufacturer-recommended mixing ratio range. The results also revealed the existence of boundary condition; this corresponding to the limit of the mixing ratio recommended by the gypsum’ manufacturer. Data provided in this study are particularly important for dental technicians with a view to attaining the best results in accuracy of fit for their prosthetic works.
- 1 January 2011
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 30 (5) , 700-706
Open AccessCharacterization of different water/powder ratios of dental gypsum using fiber Bragg grating sensors
The impact of five different water/powder (w/p) ratios in the characterization of high strength dental stone was evaluated, since the recommendations of the gypsum’ manufacturers are not always correctly followed by the dental prosthesis technicians. Fiber Bragg grating (FBG) sensors were used to measure the setting expansion and temperature variation which occurred during the setting reaction for each w/p ratio, as well as the thermal expansion coefficient. Thick mixtures with low w/p ratios had more crystals impinging upon each other during crystal growth, resulting in more expansion and more heat released. This thermal behavior was only achieved to w/p ratios within the manufacturer-recommended mixing ratio range. The results also revealed the existence of boundary condition; this corresponding to the limit of the mixing ratio recommended by the gypsum’ manufacturer. Data provided in this study are particularly important for dental technicians with a view to attaining the best results in accuracy of fit for their prosthetic works.