Alex Baldwin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alex Baldwin has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Ellis Meng
University of Southern California
5 shared publications Ellis Meng
2 shared publications- Ahuva Weltman Hirschberg
Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA
1 shared publication - Angelica M. Cobo
Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA
1 shared publication - Christopher E. Larson
Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
1 shared publication - Emmanuel Ramirez
Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
1 shared publication
Latest Publications
- 14 March 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 458
A wireless and passive multiplexable biomarker sensing system constructed entirely on a soft and flexible thin film
- 14 March 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 458
A wireless and passive multiplexable biomarker sensing system constructed entirely on a soft and flexible thin film
- Open Access
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (11) , 3159-3173
Building and Sustaining Open-Source Medical Device Projects
The open-source development model has been successfully applied to consumer and enterprise software, and recently to consumer hardware. Medical devices may become a beneficiary of this trend, as open-source medical device development has the potential to reduce costs, democratize patient access, and provide continued support to abandoned devices from failed companies. Unlike the consumer device market, the medical device market is highly regulated and involves considerable manufacturer liability that may limit the use of open-source technology. This review of open-source medical device development explores the current state of development in research and clinical products and suggests best practices for creating sustainable and effective open-source medical devices.
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (11) , 3159-3173
Open AccessBuilding and Sustaining Open-Source Medical Device Projects
The open-source development model has been successfully applied to consumer and enterprise software, and recently to consumer hardware. Medical devices may become a beneficiary of this trend, as open-source medical device development has the potential to reduce costs, democratize patient access, and provide continued support to abandoned devices from failed companies. Unlike the consumer device market, the medical device market is highly regulated and involves considerable manufacturer liability that may limit the use of open-source technology. This review of open-source medical device development explores the current state of development in research and clinical products and suggests best practices for creating sustainable and effective open-source medical devices.
- 18 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 28 (6) , 1060-1067
Fluid Temperature Measurement in Aqueous Solution via Electrochemical Impedance
A novel temperature transduction method using the high-frequency electrochemical impedance between a pair of microelectrodes exposed to aqueous solution is reported. The solution resistance of an aqueous ionic solution is highly temperature dependent, and the electrochemical impedance between two microelectrodes is dominated by solution resistance when measured at the appropriate frequency. Therefore, precise measurements of electrochemical impedance at the proper frequency in a two-electrode system can be used to transduce solution temperature. To demonstrate this method, a temperature sensor composed of two thin-film platinum electrodes on a freestanding Parylene C substrate was designed and fabricated. A platinum resistance temperature detector was co-fabricated to provide a simple means of benchmarking against an existing standard. Transduction via electrochemical impedance was achieved by measuring the real part of impedance at the frequency where phase was minimized. Fluid temperature was transduced between 15°C and 50°C with high sensitivity (-1.21%/°C) and resolution (0.02°C). A 4x improvement in sensitivity and resolution over the conventional platinum resistance temperature detector was achieved. The sensor design described here features flexible construction with inert materials which facilitates future use in biomedical or microfluidic applications. [2019-0190]
- 18 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 28 (6) , 1060-1067
Fluid Temperature Measurement in Aqueous Solution via Electrochemical Impedance
A novel temperature transduction method using the high-frequency electrochemical impedance between a pair of microelectrodes exposed to aqueous solution is reported. The solution resistance of an aqueous ionic solution is highly temperature dependent, and the electrochemical impedance between two microelectrodes is dominated by solution resistance when measured at the appropriate frequency. Therefore, precise measurements of electrochemical impedance at the proper frequency in a two-electrode system can be used to transduce solution temperature. To demonstrate this method, a temperature sensor composed of two thin-film platinum electrodes on a freestanding Parylene C substrate was designed and fabricated. A platinum resistance temperature detector was co-fabricated to provide a simple means of benchmarking against an existing standard. Transduction via electrochemical impedance was achieved by measuring the real part of impedance at the frequency where phase was minimized. Fluid temperature was transduced between 15°C and 50°C with high sensitivity (-1.21%/°C) and resolution (0.02°C). A 4x improvement in sensitivity and resolution over the conventional platinum resistance temperature detector was achieved. The sensor design described here features flexible construction with inert materials which facilitates future use in biomedical or microfluidic applications. [2019-0190]
- 19 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 27 (6) , 1082-1088
Kirigami Strain Sensors Microfabricated From Thin-Film Parylene C
A kirigami-based strategy was investigated for strain transduction, using serpentine gold traces embedded in thin-film Parylene C. Multiple kirigami slit designs were evaluated via COMSOL simulation and mechanical force testing; sensors having tightly packed slits stretched up to 17.5 mm (350% strain) before mechanical failure and 9 mm (180% strain) before electrical failure. Strain transduction was achieved by monitoring DC resistance changes during stretching. DC resistance linearly increased with strain, with sensitivities up to 0.16 Ω /mm (gauge factor = 0.007) and minimal hysteresis. High-frequency trace impedance and inter-trace capacitance were also investigated during strain cycling. Capacitance increased with strain and high-frequency impedance show a nonlinear strain relationship. The biocompatible construction and extremely low profiles (20 μm thick) of these sensors are attractive for minimally invasive in vivo strain sensing applications. [2018-0130]
- 19 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 27 (6) , 1082-1088
Kirigami Strain Sensors Microfabricated From Thin-Film Parylene C
A kirigami-based strategy was investigated for strain transduction, using serpentine gold traces embedded in thin-film Parylene C. Multiple kirigami slit designs were evaluated via COMSOL simulation and mechanical force testing; sensors having tightly packed slits stretched up to 17.5 mm (350% strain) before mechanical failure and 9 mm (180% strain) before electrical failure. Strain transduction was achieved by monitoring DC resistance changes during stretching. DC resistance linearly increased with strain, with sensitivities up to 0.16 Ω /mm (gauge factor = 0.007) and minimal hysteresis. High-frequency trace impedance and inter-trace capacitance were also investigated during strain cycling. Capacitance increased with strain and high-frequency impedance show a nonlinear strain relationship. The biocompatible construction and extremely low profiles (20 μm thick) of these sensors are attractive for minimally invasive in vivo strain sensing applications. [2018-0130]
- Open Access
- 22 August 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (9) , 422
Techniques and Considerations in the Microfabrication of Parylene C Microelectromechanical Systems
Parylene C is a promising material for constructing flexible, biocompatible and corrosion-resistant microelectromechanical systems (MEMS) devices. Historically, Parylene C has been employed as an encapsulation material for medical implants, such as stents and pacemakers, due to its strong barrier properties and biocompatibility. In the past few decades, the adaptation of planar microfabrication processes to thin film Parylene C has encouraged its use as an insulator, structural and substrate material for MEMS and other microelectronic devices. However, Parylene C presents unique challenges during microfabrication and during use with liquids, especially for flexible, thin film electronic devices. In particular, the flexibility and low thermal budget of Parylene C require modification of the fabrication techniques inherited from silicon MEMS, and poor adhesion at Parylene-Parylene and Parylene-metal interfaces causes device failure under prolonged use in wet environments. Here, we discuss in detail the promises and challenges inherent to Parylene C and present our experience in developing thin-film Parylene MEMS devices.
- 22 August 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (9) , 422
Open AccessTechniques and Considerations in the Microfabrication of Parylene C Microelectromechanical Systems
Parylene C is a promising material for constructing flexible, biocompatible and corrosion-resistant microelectromechanical systems (MEMS) devices. Historically, Parylene C has been employed as an encapsulation material for medical implants, such as stents and pacemakers, due to its strong barrier properties and biocompatibility. In the past few decades, the adaptation of planar microfabrication processes to thin film Parylene C has encouraged its use as an insulator, structural and substrate material for MEMS and other microelectronic devices. However, Parylene C presents unique challenges during microfabrication and during use with liquids, especially for flexible, thin film electronic devices. In particular, the flexibility and low thermal budget of Parylene C require modification of the fabrication techniques inherited from silicon MEMS, and poor adhesion at Parylene-Parylene and Parylene-metal interfaces causes device failure under prolonged use in wet environments. Here, we discuss in detail the promises and challenges inherent to Parylene C and present our experience in developing thin-film Parylene MEMS devices.
- 1 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 227-230
A kirigami-based Parylene C stretch sensor
We present the first slotted Parylene C kirigami device for transducing stretch-induced displacement under multiple modes of operation. Devices consist of thin-film gold traces wound among multiple rows of offset slits etched through a free-film Parylene substrate. Slits were etched via a switched-chemistry DRIE in oxygen plasma, resulting in densely packed slit designs. Multiple slit designs were evaluated and devices with more tightly packed slits were found endure greater stretch distance before failure, with devices containing more tightly packed slits able to stretch up to 9 mm (180%) without plastic deformation or compromise of electrical integrity. Multiple modes of stretch transduction were evaluated, including DC resistance changes due to strain at trace inflection points and high-frequency changes in self-impedance and inter-trace capacitance. DC resistance was found to increase linearly with stretch distance with sensitivities between 0.04 and 0.1 Ω/mm which are comparable to previously reported polyimide sensors but with a wider dynamic measurement range. Capacitance was also found to increase linearly with stretch distance after 2 mm, and high-frequency impedance increased nonlinearly, with different trace routing designs resulting in different patterns of impedance change with stretch.
- 1 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 227-230
A kirigami-based Parylene C stretch sensor
We present the first slotted Parylene C kirigami device for transducing stretch-induced displacement under multiple modes of operation. Devices consist of thin-film gold traces wound among multiple rows of offset slits etched through a free-film Parylene substrate. Slits were etched via a switched-chemistry DRIE in oxygen plasma, resulting in densely packed slit designs. Multiple slit designs were evaluated and devices with more tightly packed slits were found endure greater stretch distance before failure, with devices containing more tightly packed slits able to stretch up to 9 mm (180%) without plastic deformation or compromise of electrical integrity. Multiple modes of stretch transduction were evaluated, including DC resistance changes due to strain at trace inflection points and high-frequency changes in self-impedance and inter-trace capacitance. DC resistance was found to increase linearly with stretch distance with sensitivities between 0.04 and 0.1 Ω/mm which are comparable to previously reported polyimide sensors but with a wider dynamic measurement range. Capacitance was also found to increase linearly with stretch distance after 2 mm, and high-frequency impedance increased nonlinearly, with different trace routing designs resulting in different patterns of impedance change with stretch.
- Open Access
- 13 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 25 (6) , 1015-1024
An Electrochemical Impedance-Based Thermal Flow Sensor for Physiological Fluids
A novel electrochemical-thermal flow sensor was developed for use in physiological liquids. The sensor was constructed out of a platinum resistive heater and platinum sensing electrodes on a Parylene C substrate, rendering it flexible and fully biocompatible. During heating, changes in electrochemical impedance across the sensing electrodes were used to detect changes in temperature, and highly sensitive flow measurements were achieved with overheat temperatures of only 1 °C. The sensor's biocompatibility and low overheat temperature make it an ideal candidate for chronic in vivo applications.
- 13 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 25 (6) , 1015-1024
Open AccessAn Electrochemical Impedance-Based Thermal Flow Sensor for Physiological Fluids
A novel electrochemical-thermal flow sensor was developed for use in physiological liquids. The sensor was constructed out of a platinum resistive heater and platinum sensing electrodes on a Parylene C substrate, rendering it flexible and fully biocompatible. During heating, changes in electrochemical impedance across the sensing electrodes were used to detect changes in temperature, and highly sensitive flow measurements were achieved with overheat temperatures of only 1 °C. The sensor's biocompatibility and low overheat temperature make it an ideal candidate for chronic in vivo applications.