Qingqing Tian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qingqing Tian has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Fang Ding
Nanshan District Key Lab for Biopolymers and Safety Evaluation
1 shared publication - Fanhong Wu
School of Chemical and Environmental Engineering, Shanghai Institute of Technology, Shanghai, People’s Republic of China
1 shared publication - Jing Wang
School of Chemical and Environmental Engineering
1 shared publication Lichen Gu
Institute of Electromechanical Technology, Xi’an University of Architecture and Technology, Xi’an, China
1 shared publication- Lichen Gu
School of Mechanical and Electrical Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
1 shared publication - Lingling Guo
Jiangnan University
1 shared publication
Latest Publications
- 11 December 2019
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 234 (6) , 1196-1211
Extraction of the instantaneous speed fluctuation based on normal time–frequency transform for hydraulic system
The instantaneous speed fluctuation is the most direct manifestation of system dynamics behavior, which reflects the running status of the hydraulic system. It is crucial to mine the information contained in instantaneous speed fluctuation and extract them accurately. This paper first introduces the instantaneous speed measurement of the hydraulic system, and it is found that the instantaneous speed signal with an equal angle sampling is a harmonic signal. Next, causes of instantaneous speed fluctuation for hydraulic system are derived by kinetics analysis, where the working mechanism of the axial piston motor and the inevitable misalignment of the shafts are concerned. Then the normal time–frequency transform and the inaction method are introduced, and its high accuracy for harmonic signal extraction in additive noise is verified by comparing with the wavelet packet method with simulation analysis. Finally, the validity of the cause analysis and the extraction method are verified by experiments under different working conditions. The experimental results show that the frequencies of the instantaneous speed fluctuation components can be displayed automatically by normal time–frequency transform spectrum and their waveforms can be extracted accurately by the inaction method. It is also found that the change of the rotating speed and torque can be presented by the variety of the magnitude of the instantaneous speed fluctuation components at the 7th order and the 14th order, respectively. Cause analysis and accurate extraction of the instantaneous speed fluctuation will provide theoretical support and data support for the performance evaluation, state monitoring, and fault diagnosis of the hydraulic system.
- 11 December 2019
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 234 (6) , 1196-1211
Extraction of the instantaneous speed fluctuation based on normal time–frequency transform for hydraulic system
The instantaneous speed fluctuation is the most direct manifestation of system dynamics behavior, which reflects the running status of the hydraulic system. It is crucial to mine the information contained in instantaneous speed fluctuation and extract them accurately. This paper first introduces the instantaneous speed measurement of the hydraulic system, and it is found that the instantaneous speed signal with an equal angle sampling is a harmonic signal. Next, causes of instantaneous speed fluctuation for hydraulic system are derived by kinetics analysis, where the working mechanism of the axial piston motor and the inevitable misalignment of the shafts are concerned. Then the normal time–frequency transform and the inaction method are introduced, and its high accuracy for harmonic signal extraction in additive noise is verified by comparing with the wavelet packet method with simulation analysis. Finally, the validity of the cause analysis and the extraction method are verified by experiments under different working conditions. The experimental results show that the frequencies of the instantaneous speed fluctuation components can be displayed automatically by normal time–frequency transform spectrum and their waveforms can be extracted accurately by the inaction method. It is also found that the change of the rotating speed and torque can be presented by the variety of the magnitude of the instantaneous speed fluctuation components at the 7th order and the 14th order, respectively. Cause analysis and accurate extraction of the instantaneous speed fluctuation will provide theoretical support and data support for the performance evaluation, state monitoring, and fault diagnosis of the hydraulic system.
- 13 June 2019
- Published by Taylor & Francis in Australian Journal of Mechanical Engineering
- Vol. 19 (3) , 356-362
Instantaneous speed fluctuation extraction and its application for efficiency evaluation of hydraulic system
The efficiency of the hydraulic system is an important metric to evaluate the performance of the system. In general, multiple parameters or signals are needed to complete the efficiency evaluation. Therefore, a new method to evaluate the efficiency of the hydraulic system based on the instantaneous speed fluctuation is introduced in the paper. The proposed method involves measurement of instantaneous speed and the extraction of instantaneous speed fluctuation. By sampling-counting-based measurement method, the instantaneous speed of the hydraulic system is obtained by measuring the elapsed time for a single cycle of a square wave pulse. Then the instantaneous speed fluctuation is extracted by order tracking. The effectiveness of the proposed method is verified by two experimental cases under varying operation conditions. The experimental results show that the efficiency of the hydraulic system decreases with the increase of instantaneous speed fluctuation, and vice versa, which provides a new method for the efficiency evaluation of the hydraulic system.
- 13 June 2019
- Published by Taylor & Francis in Australian Journal of Mechanical Engineering
- Vol. 19 (3) , 356-362
Instantaneous speed fluctuation extraction and its application for efficiency evaluation of hydraulic system
The efficiency of the hydraulic system is an important metric to evaluate the performance of the system. In general, multiple parameters or signals are needed to complete the efficiency evaluation. Therefore, a new method to evaluate the efficiency of the hydraulic system based on the instantaneous speed fluctuation is introduced in the paper. The proposed method involves measurement of instantaneous speed and the extraction of instantaneous speed fluctuation. By sampling-counting-based measurement method, the instantaneous speed of the hydraulic system is obtained by measuring the elapsed time for a single cycle of a square wave pulse. Then the instantaneous speed fluctuation is extracted by order tracking. The effectiveness of the proposed method is verified by two experimental cases under varying operation conditions. The experimental results show that the efficiency of the hydraulic system decreases with the increase of instantaneous speed fluctuation, and vice versa, which provides a new method for the efficiency evaluation of the hydraulic system.
- 5 April 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (42) , 35901-35909
Targeted solid lipid nanoparticles with peptide ligand for oral delivery of atorvastatin calcium
Feasible and effective peptide ligand-modified solid lipid nanoparticles (SLNs) have been designed to improve the oral bioavailability of atorvastatin calcium (ATC). In the present work, the peptide ligand-modified SLNs loaded with ATC, namely ATC CSK-SLNs, were prepared by coupling the peptide ligand CSKSSDYQC (CSK), which showed affinity with goblet cells, to stearic acid. The physicochemical properties of the SLNs were characterized by TEM, DSC and FT-IR, which unravelled the transformation of ATC to an amorphous or molecular state from the native crystalline form. Compared with unmodified SLNs, the CSK-SLNs exhibited a more efficient cellular uptake across the Caco-2/HT29 co-cultured cell monolayer as evidenced by confocal laser microscopy. Following absorption, the mechanisms were studied using a modified in situ perfusion method in rats, which showed the segment-dependent absorption characteristics of ATC, ATC SLNs as well as ATC CSK-SLNs. The Ka (0.076 ± 0.23 min−1) and Papp (0.011 ± 0.63 cm min−1) values of the ATC CSK-SLNs were raised 2.97-fold and 2.99-fold in comparison with those of the ATC solution, implying that CSK peptide modification enhances the permeation of drugs across the epithelium. In conclusion, our results demonstrated that CSK-modified SLNs could be potential carriers for the transport of drugs across intestinal barriers.
- 5 April 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (42) , 35901-35909
Targeted solid lipid nanoparticles with peptide ligand for oral delivery of atorvastatin calcium
Feasible and effective peptide ligand-modified solid lipid nanoparticles (SLNs) have been designed to improve the oral bioavailability of atorvastatin calcium (ATC). In the present work, the peptide ligand-modified SLNs loaded with ATC, namely ATC CSK-SLNs, were prepared by coupling the peptide ligand CSKSSDYQC (CSK), which showed affinity with goblet cells, to stearic acid. The physicochemical properties of the SLNs were characterized by TEM, DSC and FT-IR, which unravelled the transformation of ATC to an amorphous or molecular state from the native crystalline form. Compared with unmodified SLNs, the CSK-SLNs exhibited a more efficient cellular uptake across the Caco-2/HT29 co-cultured cell monolayer as evidenced by confocal laser microscopy. Following absorption, the mechanisms were studied using a modified in situ perfusion method in rats, which showed the segment-dependent absorption characteristics of ATC, ATC SLNs as well as ATC CSK-SLNs. The Ka (0.076 ± 0.23 min−1) and Papp (0.011 ± 0.63 cm min−1) values of the ATC CSK-SLNs were raised 2.97-fold and 2.99-fold in comparison with those of the ATC solution, implying that CSK peptide modification enhances the permeation of drugs across the epithelium. In conclusion, our results demonstrated that CSK-modified SLNs could be potential carriers for the transport of drugs across intestinal barriers.