Arzu Canan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Arzu Canan has a total of 180 co-authors. Here are the top co-authors by number of shared publications:
- Prabhakar Rajiah
Department of Radiology, Mayo Clinic, Rochester, Minn
7 shared publications - Suhny Abbara
Department of Radiology, Mayo Clinic, Jacksonville, Fla
7 shared publications - Fernando Uliana Kay
Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75235, USA
5 shared publications Kiran Batra
Department of Radiology, University of Texas Southwestern Medical Center at Dallas, Dallas, Texas, USA
3 shared publications- Maya Wiessman
Internal Medicine Department, Cardiology Division, University of Texas Southwestern Medical Center, Dallas, TX, USA
3 shared publications Suhny Abbara
University of Texas Southwestern, Cardiothoracic Imaging, Department of Radiology, Dallas, TX, USA
3 shared publications
Latest Publications
- 11 November 2026
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
Optimizing AI-Derived CAC Volume Thresholds on Non-Gated Chest CT for Detection of Actionable Coronary Artery Calcium
Purpose: Coronary artery calcium (CAC) visually estimated on non-electrocardiogram (ECG)-gated chest CTs is reported inconsistently, limiting identification of high-risk individuals. Although automated AI-derived CAC scoring offers the potential to standardize reporting and improve reliability, this method warrants rigorous validation. Materials and Methods: Three hundred thirty-two patients (59% female, median age 62) who underwent a non-gated chest CT within 1-year of a dedicated cardiac CT with Agatston’s CAC score (CACscore) were identified between 2016 and 2022. AI-Rad Companion (Siemens) was used to compute CAC volume (AI-CACvol). AI-CACvol performance was compared with radiologists’ qualitative CAC reports (H-CACqual) using optimized thresholds for identifying actionable CAC. Model performance was further validated in a postimplementation population. Results: Median AI-CACvol was 20.3 mm³ (IQR 0-188.65), strongly correlated with CACscore (Spearman ρ=0.91, 95% CI: 0.88-0.94); median 31.55 Agatston Units (AU), IQR: 0 to 250). Agreement with CACscore was higher for AI-CACvol versus H-CACqual (weighted kappa 0.88, 95% CI: 0.84, 0.91; vs. 0.85, 95% CI: 0.82, 0.88; P =0.022). At a cutoff of 70 mm³, AI-CACvol demonstrated superior sensitivity compared with H-CACqual for detecting CAC≥100 AU, with greater sensitivity (95% vs. 75%) and comparable specificity (92% vs. 94%). In a validation cohort of 39 patients (64% female, median age 67 y), median CACscore was 43 AU (IQR 0-215) and median AI-CACvol 29.7 mm³ (IQR: 0 to 219.4). The same 70 mm³ cutoff achieved 100% sensitivity and 88% specificity for CAC≥100 AU (n=13). Conclusion: AI-derived CAC volume from non-gated chest CTs correlates strongly with reference CAC scores, showing high sensitivity at actionable thresholds. This supports potential opportunistic screening, though impact on outcomes requires study.
- 11 November 2026
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
Optimizing AI-Derived CAC Volume Thresholds on Non-Gated Chest CT for Detection of Actionable Coronary Artery Calcium
Purpose: Coronary artery calcium (CAC) visually estimated on non-electrocardiogram (ECG)-gated chest CTs is reported inconsistently, limiting identification of high-risk individuals. Although automated AI-derived CAC scoring offers the potential to standardize reporting and improve reliability, this method warrants rigorous validation. Materials and Methods: Three hundred thirty-two patients (59% female, median age 62) who underwent a non-gated chest CT within 1-year of a dedicated cardiac CT with Agatston’s CAC score (CACscore) were identified between 2016 and 2022. AI-Rad Companion (Siemens) was used to compute CAC volume (AI-CACvol). AI-CACvol performance was compared with radiologists’ qualitative CAC reports (H-CACqual) using optimized thresholds for identifying actionable CAC. Model performance was further validated in a postimplementation population. Results: Median AI-CACvol was 20.3 mm³ (IQR 0-188.65), strongly correlated with CACscore (Spearman ρ=0.91, 95% CI: 0.88-0.94); median 31.55 Agatston Units (AU), IQR: 0 to 250). Agreement with CACscore was higher for AI-CACvol versus H-CACqual (weighted kappa 0.88, 95% CI: 0.84, 0.91; vs. 0.85, 95% CI: 0.82, 0.88; P =0.022). At a cutoff of 70 mm³, AI-CACvol demonstrated superior sensitivity compared with H-CACqual for detecting CAC≥100 AU, with greater sensitivity (95% vs. 75%) and comparable specificity (92% vs. 94%). In a validation cohort of 39 patients (64% female, median age 67 y), median CACscore was 43 AU (IQR 0-215) and median AI-CACvol 29.7 mm³ (IQR: 0 to 219.4). The same 70 mm³ cutoff achieved 100% sensitivity and 88% specificity for CAC≥100 AU (n=13). Conclusion: AI-derived CAC volume from non-gated chest CTs correlates strongly with reference CAC scores, showing high sensitivity at actionable thresholds. This supports potential opportunistic screening, though impact on outcomes requires study.
- 31 October 2026
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
Updates in cardiovascular CT imaging in 2025: A year in review
- 31 October 2026
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
Updates in cardiovascular CT imaging in 2025: A year in review
- Open Access
- 17 October 2026
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- p. 1-3
Cardiac CT demonstration of perivalvular extension in aortic valve infective endocarditis
- 17 October 2026
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- p. 1-3
Open AccessCardiac CT demonstration of perivalvular extension in aortic valve infective endocarditis
- Open Access
- 17 April 2026
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 42 (9) , 1-2
Gastro-pericardial fistula with pneumopericardium
- 17 April 2026
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 42 (9) , 1-2
Open AccessGastro-pericardial fistula with pneumopericardium
- 15 February 2026
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 77 (3) , 579-593
Tips and Tricks for Interpreting Coronary CT Angiography – Part 2: Accurate Assessment of Stenosis Severity
Accurate quantification of coronary stenosis on coronary CT angiography (CCTA) is essential for appropriate risk stratification and clinical decision-making, yet several technical and interpretative pitfalls can compromise diagnostic accuracy. This second part of a two-part review examines common factors that lead to overestimation or underestimation of stenosis severity, with attention to how these errors influence CAD-RADS categorization, downstream testing, and patient management. Using case-based examples, we describe key contributors to misinterpretation and present practical strategies to mitigate these pitfalls. By recognizing these nuances and employing a structured, standardized interpretive approach, readers can minimize errors in stenosis assessment and enhance the reliability of CCTA as a noninvasive tool for evaluating coronary artery disease.
- 15 February 2026
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 77 (3) , 579-593
Tips and Tricks for Interpreting Coronary CT Angiography – Part 2: Accurate Assessment of Stenosis Severity
Accurate quantification of coronary stenosis on coronary CT angiography (CCTA) is essential for appropriate risk stratification and clinical decision-making, yet several technical and interpretative pitfalls can compromise diagnostic accuracy. This second part of a two-part review examines common factors that lead to overestimation or underestimation of stenosis severity, with attention to how these errors influence CAD-RADS categorization, downstream testing, and patient management. Using case-based examples, we describe key contributors to misinterpretation and present practical strategies to mitigate these pitfalls. By recognizing these nuances and employing a structured, standardized interpretive approach, readers can minimize errors in stenosis assessment and enhance the reliability of CCTA as a noninvasive tool for evaluating coronary artery disease.
- 15 February 2026
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 77 (3) , 562-578
Tips and Tricks for Interpreting Coronary CT Angiography – Part 1: Identifying Artifacts and Avoiding Misdiagnosis
Coronary CT angiography (CCTA) offers excellent negative predictive value for ruling out obstructive coronary artery disease (CAD); however, several interpretative pitfalls can lead to diagnostic errors including false-negative, false-positive results or inaccurate estimation of degree of stenosis. These errors may influence patient management, prompt unnecessary or missed downstream testing, and ultimately affect clinical outcomes. This two-part article reviews the most common sources of diagnostic inaccuracy in CCTA through case-based examples. Part I highlights factors that contribute to missed or overdiagnosed coronary lesions while Part II focuses on pitfalls that lead to underestimation or overestimation of stenosis severity and outlines practical strategies to mitigate these errors. Recognizing the inherent limitations of CCTA and employing a systematic, structured interpretive approach are essential for preserving its high diagnostic accuracy and ensuring optimal patient care.
- 15 February 2026
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 77 (3) , 562-578
Tips and Tricks for Interpreting Coronary CT Angiography – Part 1: Identifying Artifacts and Avoiding Misdiagnosis
Coronary CT angiography (CCTA) offers excellent negative predictive value for ruling out obstructive coronary artery disease (CAD); however, several interpretative pitfalls can lead to diagnostic errors including false-negative, false-positive results or inaccurate estimation of degree of stenosis. These errors may influence patient management, prompt unnecessary or missed downstream testing, and ultimately affect clinical outcomes. This two-part article reviews the most common sources of diagnostic inaccuracy in CCTA through case-based examples. Part I highlights factors that contribute to missed or overdiagnosed coronary lesions while Part II focuses on pitfalls that lead to underestimation or overestimation of stenosis severity and outlines practical strategies to mitigate these errors. Recognizing the inherent limitations of CCTA and employing a systematic, structured interpretive approach are essential for preserving its high diagnostic accuracy and ensuring optimal patient care.
- 1 December 2025
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 42 (2) , 373-374
Extra-anatomic ascending-to-descending aortic bypass for aortic coarctation
- 1 December 2025
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 42 (2) , 373-374
Extra-anatomic ascending-to-descending aortic bypass for aortic coarctation
- 17 October 2025
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 41 (12) , 2499-2500
Left aortic arch with aberrant right vertebral artery
- 17 October 2025
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 41 (12) , 2499-2500
Left aortic arch with aberrant right vertebral artery
- 1 May 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 315 (2) , e242087
Diagnostic Accuracy of On-Premise Automated Coronary CT Angiography Analysis Based on Coronary Artery Disease Reporting and Data System 2.0
On-premises artificial intelligence was accurate in ruling out obstructive coronary artery disease at coronary CT angiography and achieved substantial to near-perfect agreement with human experts based on Coronary Artery Disease Reporting and Data System 2.0 categories for stenosis severity and plaque burden.
- 1 May 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 315 (2) , e242087
Diagnostic Accuracy of On-Premise Automated Coronary CT Angiography Analysis Based on Coronary Artery Disease Reporting and Data System 2.0
On-premises artificial intelligence was accurate in ruling out obstructive coronary artery disease at coronary CT angiography and achieved substantial to near-perfect agreement with human experts based on Coronary Artery Disease Reporting and Data System 2.0 categories for stenosis severity and plaque burden.
- 19 October 2023
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 17 (6) , 453-458
Accuracy of incidental visual coronary artery calcium assessment compared with dedicated coronary artery calcium scoring
- 19 October 2023
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 17 (6) , 453-458
Accuracy of incidental visual coronary artery calcium assessment compared with dedicated coronary artery calcium scoring