Seonwoong Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Seonwoong Kim has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Dae-Jin Kim
Department of Architectural Engineering, Kyung Hee University, Yongin, South Korea
1 shared publication - Dongho Rie
Fire Disaster Prevention Research Center, Incheon National University, Incheon 22012, Republic of Korea
1 shared publication - Jang-Won Lee
Department of Safety Engineering, Incheon National University, Incheon 22012, Korea
1 shared publication - Jeongwon Ko
Daewoo Institute of Construction Technology, DAEWOO E&C, Suwon 16297, Korea
1 shared publication - Jieun Jung
Department of Architectural Engineering, Kyung Hee University, 1732, Deogyeong-daero, Giheung-gu, Yongin-si, Gyeonggi-do 446-701, Korea
1 shared publication Kyungkoo Lee
1 shared publication
Latest Publications
- 12 August 2023
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 23 (5) , 1329-1342
Experimental Study on Shear Strength of Indirect Joint Strengthened by Steel Moment Frames
- 12 August 2023
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 23 (5) , 1329-1342
Experimental Study on Shear Strength of Indirect Joint Strengthened by Steel Moment Frames
- 16 September 2021
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 21 (5) , 1845-1858
Shear strength investigation of connections between RC and strengthened steel frames
- 16 September 2021
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 21 (5) , 1845-1858
Shear strength investigation of connections between RC and strengthened steel frames
- 27 February 2021
- Published by Korean Society of Steel Construction in Journal of Korean Society of Steel Construction
- Vol. 33 (1) , 31-42
Experimental Study on Shear-Resistant Capacity of Bolted Indirect Connection for Steel Seismic Retrofit Method
- 27 February 2021
- Published by Korean Society of Steel Construction in Journal of Korean Society of Steel Construction
- Vol. 33 (1) , 31-42
Experimental Study on Shear-Resistant Capacity of Bolted Indirect Connection for Steel Seismic Retrofit Method
- 18 February 2021
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 21 (3) , 757-770
Seismic Retrofitting Effect of RC Buildings using Perimeter Steel Moment Frames
- 18 February 2021
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 21 (3) , 757-770
Seismic Retrofitting Effect of RC Buildings using Perimeter Steel Moment Frames
- 27 December 2020
- Published by Korean Society of Steel Construction in Journal of Korean Society of Steel Construction
- Vol. 32 (6) , 363-374
Experimental Study on Shear-Resistant Capacity of Indirect Connection for Seismic Retrofit Using Steel Moment Frames
- 27 December 2020
- Published by Korean Society of Steel Construction in Journal of Korean Society of Steel Construction
- Vol. 32 (6) , 363-374
Experimental Study on Shear-Resistant Capacity of Indirect Connection for Seismic Retrofit Using Steel Moment Frames
- 30 September 2020
- Published by Earthquake Engineering Society of Korea in Journal of the Earthquake Engineering Society of Korea
- Vol. 24 (5) , 233-241
Seismic Performance Evaluation of Non-Seismic Reinforced Concrete Buildings Strengthened by Perimeter Steel Moment Frame
- 30 September 2020
- Published by Earthquake Engineering Society of Korea in Journal of the Earthquake Engineering Society of Korea
- Vol. 24 (5) , 233-241
Seismic Performance Evaluation of Non-Seismic Reinforced Concrete Buildings Strengthened by Perimeter Steel Moment Frame
- 31 January 2020
- Published by Earthquake Engineering Society of Korea in Journal of the Earthquake Engineering Society of Korea
- Vol. 24 (1) , 29-37
Seismic Performance Evaluation of Reinforced Concrete Buildings Strengthened by Embedded Steel Frame
- 31 January 2020
- Published by Earthquake Engineering Society of Korea in Journal of the Earthquake Engineering Society of Korea
- Vol. 24 (1) , 29-37
Seismic Performance Evaluation of Reinforced Concrete Buildings Strengthened by Embedded Steel Frame
- Open Access
- 27 March 2019
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 11 (3)
Seismic performance evaluation of high-rise steel buildings dependent on wind exposures
The lateral load-resisting system of high-rise buildings in regions of low and moderate seismicity and strong wind such as the typhoon in the Korean peninsula considers the wind load as the governed lateral force so that the practical structural engineer tends to skip the evaluation against the seismic load. This study is to investigate wind-designed steel diagrid buildings located in these regions and check the possibility of the elastic design of them out. To this end, first, the diagrid high-rise buildings were designed to satisfy the wind serviceability criteria specified in KBC 2016. Then, the response spectrum analyses were performed under various slenderness ratio and wind exposures. The analyses demonstrated the good seismic performance of these wind-designed diagrid high-rise buildings because of the significant over-strength induced by the lateral load-resisting system of high-rise buildings. Also, the analysis results showed that the elastic seismic design process of some diagrid high-rise buildings may be accepted based on slenderness ratios in all wind exposures.
- 27 March 2019
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 11 (3)
Open AccessSeismic performance evaluation of high-rise steel buildings dependent on wind exposures
The lateral load-resisting system of high-rise buildings in regions of low and moderate seismicity and strong wind such as the typhoon in the Korean peninsula considers the wind load as the governed lateral force so that the practical structural engineer tends to skip the evaluation against the seismic load. This study is to investigate wind-designed steel diagrid buildings located in these regions and check the possibility of the elastic design of them out. To this end, first, the diagrid high-rise buildings were designed to satisfy the wind serviceability criteria specified in KBC 2016. Then, the response spectrum analyses were performed under various slenderness ratio and wind exposures. The analyses demonstrated the good seismic performance of these wind-designed diagrid high-rise buildings because of the significant over-strength induced by the lateral load-resisting system of high-rise buildings. Also, the analysis results showed that the elastic seismic design process of some diagrid high-rise buildings may be accepted based on slenderness ratios in all wind exposures.
- 30 August 2018
- Published by Earthquake Engineering Society of Korea in Journal of the Earthquake Engineering Society of Korea
- Vol. 22 (6) , 353-360
Progressive Collapse-Resistant Rotational Capacity Evaluation of WUF-W Connection by Fracture Index Analysis
- 30 August 2018
- Published by Earthquake Engineering Society of Korea in Journal of the Earthquake Engineering Society of Korea
- Vol. 22 (6) , 353-360
Progressive Collapse-Resistant Rotational Capacity Evaluation of WUF-W Connection by Fracture Index Analysis
- Open Access
- 27 June 2018
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 10 (6)
Structural performance evaluation of a full-scale tempered glass guard and handrail system
In this study, the structural performance capabilities of a tempered glass guard and handrail system not reinforced with a structural framework are investigated. It is known that this cantilevered system has low redundancy and that the glass material itself is brittle. Considering these characteristics, full-scale experiments involving two (bolted and plaster-filled) connection types and two (rectangular and parallel) glass shapes of the types in frequent use as well as two (monotonic and cyclic) loading methods as three variables in total were conducted. Depending on the connection type, the stress concentration phenomenon at the point of the connection appears to be unavoidable. The final fracture mode is very dangerous and sudden such that it is necessary to control the structural safety by means of a higher margin. Specimens with a bolted connection showed inferior performance due to the brittle fracture stemming from the stress concentration phenomenon, while specimens with the plaster-filled connection exhibited excellent performance even under cyclic loading. These results therefore demonstrate that the guard and handrail system with a bolted connection should be structurally reinforced.
- 27 June 2018
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 10 (6)
Open AccessStructural performance evaluation of a full-scale tempered glass guard and handrail system
In this study, the structural performance capabilities of a tempered glass guard and handrail system not reinforced with a structural framework are investigated. It is known that this cantilevered system has low redundancy and that the glass material itself is brittle. Considering these characteristics, full-scale experiments involving two (bolted and plaster-filled) connection types and two (rectangular and parallel) glass shapes of the types in frequent use as well as two (monotonic and cyclic) loading methods as three variables in total were conducted. Depending on the connection type, the stress concentration phenomenon at the point of the connection appears to be unavoidable. The final fracture mode is very dangerous and sudden such that it is necessary to control the structural safety by means of a higher margin. Specimens with a bolted connection showed inferior performance due to the brittle fracture stemming from the stress concentration phenomenon, while specimens with the plaster-filled connection exhibited excellent performance even under cyclic loading. These results therefore demonstrate that the guard and handrail system with a bolted connection should be structurally reinforced.