Christian Frech
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Christian Frech has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
Mathias Hafner
Institute of Molecular Biology and Cell Culture Technology, Technical University of Applied Sciences Mannheim, Germany
12 shared publicationsThomas von Hirschheydt
Roche Diagnostics GmbH, Bioprocess Development, 82377 Penzberg, Germany
7 shared publicationsSimon Kluters
Institute of Biochemistry, University of Applied Sciences Mannheim, Mannheim, Germany
5 shared publicationsHeiner Graalfs
Merck KGaA, Frankfurter Str 250, D-64293 Darmstadt, Germany
4 shared publicationsYi Feng Lee
Institute of Biochemistry, Department of Biotechnology, University of Applied Sciences Mannheim, Mannheim, Germany
4 shared publicationsCarolin Stange
Institute for Biochemistry, University of Applied Sciences Mannheim, 68163 Mannheim, Germany
3 shared publications
Latest Publications
- Open Access
- 9 June 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1783, 467175
Electrically driven elution in digital protein a membrane chromatography: An alternative to traditional low-pH elution
- 9 June 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1783, 467175
Open AccessElectrically driven elution in digital protein a membrane chromatography: An alternative to traditional low-pH elution
- Open Access
- 24 May 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1783, 467126
Exploiting ligand-driven salt selectivity for aggregate retention: enhancing monomer resolution on a high elution pH Protein A membrane
- 24 May 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1783, 467126
Open AccessExploiting ligand-driven salt selectivity for aggregate retention: enhancing monomer resolution on a high elution pH Protein A membrane
- Open Access
- 12 February 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1772, 466806
Detergent-induced antibody elution at near-neutral pH in protein A membrane chromatography
- 12 February 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1772, 466806
Open AccessDetergent-induced antibody elution at near-neutral pH in protein A membrane chromatography
- Open Access
- 10 September 2025
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 101 (7) , 1407-1419
Mixed‐mode membrane chromatography: mechanistic‐modeling‐based optimization and scale‐up of antibody charge variant separation using a novel membrane adsorber
BACKGROUND: Efficient manufacturing of complex biopharmaceuticals increasingly relies on innovative downstream processing strategies. Membrane chromatography offers a promising alternative to resin‐based systems by enabling high‐throughput separations at elevated flow rates. Typically used in flow‐through mode, its industrial applications range from contaminant removal (DNA, host cell proteins) to purification of large biomolecules like viruses, virus‐like particles and protein complexes. The Natrix® CH membrane, a novel mixed‐mode membrane integrating ion‐exchange and hydrophobic interaction functionalities, has shown potential in complex or elevated salt conditions ( ca 0.1 mol L −1 ). This study evaluates its performance in bind‐and‐elute mode for separating monoclonal antibody charge variants and establishes a scalable mechanistic model. RESULTS: Initial comparisons with a traditional ion‐exchange membrane showed that the Natrix® CH had enhanced selectivity, as demonstrated by better separation of charge variants and an overall increase of retention up to one pH unit. Both might be attributed to its additional hydrophobic ligand. Linear gradient elution experiments enabled calibration of a stoichiometric displacement model under low‐loading conditions. High‐loading experiments up to 35 mg mL MV −1 refined a steric mass action model using a reverse fitting procedure to capture the nonlinear range of the adsorption isotherm. These models were applied in silico to design optimized separation conditions, including an antiparallel dual pH and salt gradient. This dual‐gradient strategy achieved high‐resolution variant separation and was validated experimentally. A scale‐up from laboratory scale (1.06 mL) to a bench‐scale (8.8 mL) membrane device (eightfold increase) demonstrated consistent elution behavior and separation performance, even at elevated flow rates (up to 10 membrane volumes per minute), with only minor reductions in dynamic binding capacity (e.g. DBC 10% decreased by 7%). CONCLUSION: Mechanistic in silico modeling enabled accurate prediction, optimization and successful scale‐up of charge variant separation on Natrix® CH membranes. The approach demonstrated good applicability and scalability within the calibrated range, advancing membrane chromatography as a high‐throughput alternative for efficient protein purification. © 2025 The Author(s). Journal of Chemical Technology and Biotechnology published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry (SCI).
- 10 September 2025
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 101 (7) , 1407-1419
Open AccessMixed‐mode membrane chromatography: mechanistic‐modeling‐based optimization and scale‐up of antibody charge variant separation using a novel membrane adsorber
BACKGROUND: Efficient manufacturing of complex biopharmaceuticals increasingly relies on innovative downstream processing strategies. Membrane chromatography offers a promising alternative to resin‐based systems by enabling high‐throughput separations at elevated flow rates. Typically used in flow‐through mode, its industrial applications range from contaminant removal (DNA, host cell proteins) to purification of large biomolecules like viruses, virus‐like particles and protein complexes. The Natrix® CH membrane, a novel mixed‐mode membrane integrating ion‐exchange and hydrophobic interaction functionalities, has shown potential in complex or elevated salt conditions ( ca 0.1 mol L −1 ). This study evaluates its performance in bind‐and‐elute mode for separating monoclonal antibody charge variants and establishes a scalable mechanistic model. RESULTS: Initial comparisons with a traditional ion‐exchange membrane showed that the Natrix® CH had enhanced selectivity, as demonstrated by better separation of charge variants and an overall increase of retention up to one pH unit. Both might be attributed to its additional hydrophobic ligand. Linear gradient elution experiments enabled calibration of a stoichiometric displacement model under low‐loading conditions. High‐loading experiments up to 35 mg mL MV −1 refined a steric mass action model using a reverse fitting procedure to capture the nonlinear range of the adsorption isotherm. These models were applied in silico to design optimized separation conditions, including an antiparallel dual pH and salt gradient. This dual‐gradient strategy achieved high‐resolution variant separation and was validated experimentally. A scale‐up from laboratory scale (1.06 mL) to a bench‐scale (8.8 mL) membrane device (eightfold increase) demonstrated consistent elution behavior and separation performance, even at elevated flow rates (up to 10 membrane volumes per minute), with only minor reductions in dynamic binding capacity (e.g. DBC 10% decreased by 7%). CONCLUSION: Mechanistic in silico modeling enabled accurate prediction, optimization and successful scale‐up of charge variant separation on Natrix® CH membranes. The approach demonstrated good applicability and scalability within the calibrated range, advancing membrane chromatography as a high‐throughput alternative for efficient protein purification. © 2025 The Author(s). Journal of Chemical Technology and Biotechnology published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry (SCI).
- Open Access
- 4 August 2025
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 101 (7) , 1370-1383
Optimizing rapeseed protein purification: a continuous chromatographic approach for napin and cruciferin
BACKGROUND: Napin and cruciferin, the predominant storage proteins in Brassica napus (rapeseed), exhibit favorable techno‐functional properties such as emulsification and gel formation, positioning them as promising candidates for the encapsulation and delivery of bioactive compounds. Their classification as GRAS (Generally Recognized As Safe), combined with their biodegradability and biocompatibility, highlights their potential as sustainable alternatives to synthetic delivery matrices. However, their broader application is hindered by the absence of scalable purification processes that concurrently ensure high purity and yield. RESULTS: This study presents the development of a fully continuous chromatographic platform for the simultaneous isolation of napin and cruciferin from crude rapeseed extracts. Napin was purified via cation‐exchange chromatography, whereas cruciferin was isolated using anion exchange. Key process parameters were identified through systematic batch screening, with emphasis on the initial binding conditions to enable direct coupling of both chromatographic steps. The optimized protocol permitted efficient sequential protein capture with minimal buffer adjustment, leading to significantly reduced process time and resource consumption. The purified proteins exhibited high purity and are of suitable quality for future applications. CONCLUSION: The continuous purification process established in this study constitutes a significant step toward the scalable and sustainable processing of plant‐derived proteins. By applying principles of process intensification, the method enhances overall operational efficiency and environmental compatibility. Importantly, the high‐purity napin and cruciferin obtained through this platform provide a promising foundation for future development of bioactive compound encapsulation and delivery systems, supporting the broader integration of plant‐based biopolymers in pharmaceutical and nutraceutical applications. © 2025 The Author(s). Journal of Chemical Technology and Biotechnology published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry (SCI).
- 4 August 2025
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 101 (7) , 1370-1383
Open AccessOptimizing rapeseed protein purification: a continuous chromatographic approach for napin and cruciferin
BACKGROUND: Napin and cruciferin, the predominant storage proteins in Brassica napus (rapeseed), exhibit favorable techno‐functional properties such as emulsification and gel formation, positioning them as promising candidates for the encapsulation and delivery of bioactive compounds. Their classification as GRAS (Generally Recognized As Safe), combined with their biodegradability and biocompatibility, highlights their potential as sustainable alternatives to synthetic delivery matrices. However, their broader application is hindered by the absence of scalable purification processes that concurrently ensure high purity and yield. RESULTS: This study presents the development of a fully continuous chromatographic platform for the simultaneous isolation of napin and cruciferin from crude rapeseed extracts. Napin was purified via cation‐exchange chromatography, whereas cruciferin was isolated using anion exchange. Key process parameters were identified through systematic batch screening, with emphasis on the initial binding conditions to enable direct coupling of both chromatographic steps. The optimized protocol permitted efficient sequential protein capture with minimal buffer adjustment, leading to significantly reduced process time and resource consumption. The purified proteins exhibited high purity and are of suitable quality for future applications. CONCLUSION: The continuous purification process established in this study constitutes a significant step toward the scalable and sustainable processing of plant‐derived proteins. By applying principles of process intensification, the method enhances overall operational efficiency and environmental compatibility. Importantly, the high‐purity napin and cruciferin obtained through this platform provide a promising foundation for future development of bioactive compound encapsulation and delivery systems, supporting the broader integration of plant‐based biopolymers in pharmaceutical and nutraceutical applications. © 2025 The Author(s). Journal of Chemical Technology and Biotechnology published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry (SCI).
- Open Access
- 5 October 2023
- Published by MDPI AG in Pharmaceuticals
- Vol. 16 (10) , 1418
Site-Specific Structural Changes in Long-Term-Stressed Monoclonal Antibody Revealed with DEPC Covalent-Labeling and Quantitative Mass Spectrometry
Studies of structural changes in mAbs under forced stress and storage conditions are essential for the recognition of degradation hotspots, which can be further remodeled to improve the stability of the respective protein. Herein, we used diethyl pyrocarbonate (DEPC)-based covalent labeling mass spectrometry (CL-MS) to assess structural changes in a model mAb (SILuMAb). Structural changes in the heat-stressed mAb samples were confirmed at specific amino acid positions from the DEPC label mass seen in the fragment ion mass spectrum. The degree of structural change was also quantified by increased or decreased DEPC labeling at specific sites; an increase or decrease indicated an unfolded or aggregated state of the mAb, respectively. Strikingly, for heat-stressed SILuMAb samples, an aggregation-prone area was identified in the CDR region. In the case of longterm stress, the structural consequences for SILuMAb samples stored for up to two years at 2–8 °C were studied with SEC-UV and DEPC-based CL-MS. While SEC-UV analysis only indicated fragmentation of SILuMAb, DEPC-based CL-MS analysis further pinpointed the finding to structural disturbances of disulfide bonds at specific cysteines. This emphasized the utility of DEPC CL-MS for studying disulfide rearrangement. Taken together, our data suggests that DEPC CL-MS can complement more technically challenging methods in the evaluation of the structural stability of mAbs.
- 5 October 2023
- Published by MDPI AG in Pharmaceuticals
- Vol. 16 (10) , 1418
Open AccessSite-Specific Structural Changes in Long-Term-Stressed Monoclonal Antibody Revealed with DEPC Covalent-Labeling and Quantitative Mass Spectrometry
Studies of structural changes in mAbs under forced stress and storage conditions are essential for the recognition of degradation hotspots, which can be further remodeled to improve the stability of the respective protein. Herein, we used diethyl pyrocarbonate (DEPC)-based covalent labeling mass spectrometry (CL-MS) to assess structural changes in a model mAb (SILuMAb). Structural changes in the heat-stressed mAb samples were confirmed at specific amino acid positions from the DEPC label mass seen in the fragment ion mass spectrum. The degree of structural change was also quantified by increased or decreased DEPC labeling at specific sites; an increase or decrease indicated an unfolded or aggregated state of the mAb, respectively. Strikingly, for heat-stressed SILuMAb samples, an aggregation-prone area was identified in the CDR region. In the case of longterm stress, the structural consequences for SILuMAb samples stored for up to two years at 2–8 °C were studied with SEC-UV and DEPC-based CL-MS. While SEC-UV analysis only indicated fragmentation of SILuMAb, DEPC-based CL-MS analysis further pinpointed the finding to structural disturbances of disulfide bonds at specific cysteines. This emphasized the utility of DEPC CL-MS for studying disulfide rearrangement. Taken together, our data suggests that DEPC CL-MS can complement more technically challenging methods in the evaluation of the structural stability of mAbs.
- 2 May 2023
- Published by Elsevier in Journal of Chromatography B
- Vol. 1224, 123735
Effect of salt modulators on the elution behavior of insulin and the separation of product-related impurities in reversed-phase chromatography
- 2 May 2023
- Published by Elsevier in Journal of Chromatography B
- Vol. 1224, 123735
Effect of salt modulators on the elution behavior of insulin and the separation of product-related impurities in reversed-phase chromatography
- Open Access
- 13 March 2023
- Published by Wiley in Journal of Separation Science
- Vol. 46 (9) , e2300031
Mechanistic modeling of cation exchange chromatography scale‐up considering packing inhomogeneities
In process development and characterization, the scale‐up of chromatographic steps is a crucial part and brings a number of challenges. Usually, scale‐down models are used to represent the process step, and constant column properties are assumed. The scaling is then typically based on the concept of linear scale‐up. In this work, a mechanistic model describing an anti‐Langmuirian to Langmuirian elution behavior of a polypeptide, calibrated with a pre‐packed 1 ml column, is applied to demonstrate the scalability to larger column volumes up to 28.2 ml. Using individual column parameters for each column size, scaling to similar eluting salt concentrations, peak heights, and shapes is experimentally demonstrated by considering the model's relationship between the normalized gradient slope and the eluting salt concentration. Further scale‐up simulations show improved model predictions when radial inhomogeneities in packing quality are considered.
- 13 March 2023
- Published by Wiley in Journal of Separation Science
- Vol. 46 (9) , e2300031
Open AccessMechanistic modeling of cation exchange chromatography scale‐up considering packing inhomogeneities
In process development and characterization, the scale‐up of chromatographic steps is a crucial part and brings a number of challenges. Usually, scale‐down models are used to represent the process step, and constant column properties are assumed. The scaling is then typically based on the concept of linear scale‐up. In this work, a mechanistic model describing an anti‐Langmuirian to Langmuirian elution behavior of a polypeptide, calibrated with a pre‐packed 1 ml column, is applied to demonstrate the scalability to larger column volumes up to 28.2 ml. Using individual column parameters for each column size, scaling to similar eluting salt concentrations, peak heights, and shapes is experimentally demonstrated by considering the model's relationship between the normalized gradient slope and the eluting salt concentration. Further scale‐up simulations show improved model predictions when radial inhomogeneities in packing quality are considered.
- 6 December 2022
- Published by Elsevier in Journal of Chromatography B
- Vol. 1214, 123563
Two peak elution behavior of a monoclonal antibody in cation exchange chromatography as a screening tool for excipients
- 6 December 2022
- Published by Elsevier in Journal of Chromatography B
- Vol. 1214, 123563
Two peak elution behavior of a monoclonal antibody in cation exchange chromatography as a screening tool for excipients