Michael Royer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael Royer has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Kevin W. Houser
Pacific Northwest National Laboratory, Portland, Oregon, USA
9 shared publications - Belal Abboushi
Pacific Northwest National Laboratory, Portland, OR, USA
6 shared publications - Lia Irvin
Pacific Northwest National Laboratory, Portland, OR, USA
6 shared publications - Tony Esposito
Department of Architectural Engineering, The Pennsylvania State University, University Park, PA, USA
6 shared publications - Eduardo Rodriguez-Feo Bermudez
Pacific Northwest National Laboratory, Portland, OR, USA
5 shared publications - Kevin A. G. Smet
KU Leuven
4 shared publications
Latest Publications
- 14 April 2026
- Published by SAGE Publications in Lighting Research & Technology
Characterizing the temporal light modulation of the LED products replacing linear fluorescent lamps
The transition from linear fluorescent lamps to LED products has reintroduced problematic temporal light modulation (TLM, also known as flicker) in commercial and educational spaces. This study measured the TLM performance of 58 LED products, beginning with tubular light-emitting diodes (TLEDs) and then expanding to other lighting products that are commonly selected when switching from linear fluorescent to LED. Nearly 25% of the products measured exceeded the TLM thresholds recommended by ANSI/IES TM-39-25, indicating poor TLM performance, although performance varied across product categories. Type B TLED lamps had the poorest TLM performance, with nearly half failing to meet the minimum TLM threshold. As many products are marketed as having low to no flicker, it may be difficult for building owners and operators to differentiate among LED products.
- 14 April 2026
- Published by SAGE Publications in Lighting Research & Technology
Characterizing the temporal light modulation of the LED products replacing linear fluorescent lamps
The transition from linear fluorescent lamps to LED products has reintroduced problematic temporal light modulation (TLM, also known as flicker) in commercial and educational spaces. This study measured the TLM performance of 58 LED products, beginning with tubular light-emitting diodes (TLEDs) and then expanding to other lighting products that are commonly selected when switching from linear fluorescent to LED. Nearly 25% of the products measured exceeded the TLM thresholds recommended by ANSI/IES TM-39-25, indicating poor TLM performance, although performance varied across product categories. Type B TLED lamps had the poorest TLM performance, with nearly half failing to meet the minimum TLM threshold. As many products are marketed as having low to no flicker, it may be difficult for building owners and operators to differentiate among LED products.
- 13 March 2026
- Published by SAGE Publications in Lighting Research & Technology
Research note: Establishing criteria for responses to temporal light modulation
Concerns about temporal light modulation (TLM) from LEDs are beginning to turn into consensus-based metrics and guidance. One important point of consideration is how to establish performance criteria based on metrics like the stroboscopic visibility measure and the phantom array visibility measure. This brief paper describes a new technical memorandum, TM-39, from the Illuminating Engineering Society, including how the committee developed the specification levels it proposes. For such documents to be effective, the broader lighting industry needs to understand what meeting the thresholds will and will not accomplish; this paper provides an important explanation of proper interpretation and limitations. Finally, it suggests future research that can continue to strengthen the methods being used to limit TLM and improve lighting quality.
- 13 March 2026
- Published by SAGE Publications in Lighting Research & Technology
Research note: Establishing criteria for responses to temporal light modulation
Concerns about temporal light modulation (TLM) from LEDs are beginning to turn into consensus-based metrics and guidance. One important point of consideration is how to establish performance criteria based on metrics like the stroboscopic visibility measure and the phantom array visibility measure. This brief paper describes a new technical memorandum, TM-39, from the Illuminating Engineering Society, including how the committee developed the specification levels it proposes. For such documents to be effective, the broader lighting industry needs to understand what meeting the thresholds will and will not accomplish; this paper provides an important explanation of proper interpretation and limitations. Finally, it suggests future research that can continue to strengthen the methods being used to limit TLM and improve lighting quality.
- 10 February 2026
- Published by SAGE Publications in Lighting Research & Technology
Spectral tuning to increase spatial brightness: effect on visual performance, eye fatigue and comparison of 5-s and 20-min exposure durations
An experiment was conducted to evaluate the effect of a spectral power distribution (SPD) optimized to increase spatial brightness compared to one approximating a typical blue-pump, phosphor-converted LED (YAG:Ce). Chromatically and luminance-adapted participants completed a reading task, visual search task, numerical verification task and provided ratings for brightness, vividness, warmth and preference over the course of approximately 20 min for each of four lighting conditions (two SPDs by two illuminance levels (nominally 250 lx and 500 lx)). As a final task, the participants chose the brighter SPD between the two SPDs that were alternated every 5 s. In alignment with a past experiment where participants provided ratings after viewing 60 stimuli for about 20 s to 30 s each, the brightness-optimized SPD was rated as brighter, more vibrant and more preferred than the PC-like SPD. When evaluated as a choice in a rapid sequential presentation, the brightness-optimized SPD was chosen as brighter than the PC-like SPD 28 out of 30 times. There was not a statistically significant change in spontaneous blink rate (an indicator of visual fatigue) or blink duration, nor any difference in glare, eye fatigue or eye discomfort. Results for visual performance were mixed.
- 10 February 2026
- Published by SAGE Publications in Lighting Research & Technology
Spectral tuning to increase spatial brightness: effect on visual performance, eye fatigue and comparison of 5-s and 20-min exposure durations
An experiment was conducted to evaluate the effect of a spectral power distribution (SPD) optimized to increase spatial brightness compared to one approximating a typical blue-pump, phosphor-converted LED (YAG:Ce). Chromatically and luminance-adapted participants completed a reading task, visual search task, numerical verification task and provided ratings for brightness, vividness, warmth and preference over the course of approximately 20 min for each of four lighting conditions (two SPDs by two illuminance levels (nominally 250 lx and 500 lx)). As a final task, the participants chose the brighter SPD between the two SPDs that were alternated every 5 s. In alignment with a past experiment where participants provided ratings after viewing 60 stimuli for about 20 s to 30 s each, the brightness-optimized SPD was rated as brighter, more vibrant and more preferred than the PC-like SPD. When evaluated as a choice in a rapid sequential presentation, the brightness-optimized SPD was chosen as brighter than the PC-like SPD 28 out of 30 times. There was not a statistically significant change in spontaneous blink rate (an indicator of visual fatigue) or blink duration, nor any difference in glare, eye fatigue or eye discomfort. Results for visual performance were mixed.
- 4 February 2026
- Published by SAGE Publications in Lighting Research & Technology
- Vol. 58 (6-7) , 595-614
LED array spatial frequency impacts discomfort and afterimages in a simulated nighttime environment
LED luminaires with apertures containing visually resolvable bright spots are commonly used to illuminate outdoor environments. However, the impact of the distance between LEDs, which determines spatial frequency at a given viewing distance, on perceived discomfort caused by these luminaires remains unclear. This study involved 29 participants who were shown 68 stimuli varying in spatial frequency, intensity, diffusion level and ambient lighting in a dark laboratory setting. Participants reported their experiences of discomfort from glare, ability to resolve individual LEDs and afterimages. The findings revealed that increased spatial frequency heightened both discomfort and the likelihood of experiencing afterimages. It is hypothesized that the point spread function of the eye contributed to these effects, where sources began to be perceived as a single larger source with equal or greater intensity. These results suggest that LED luminaire designs should favour configurations with lower spatial frequencies to minimize discomfort. A simple quantity, direct illuminance at the eye, is recommended for use to predict discomfort from glare because it performed like other more complex models.
- 4 February 2026
- Published by SAGE Publications in Lighting Research & Technology
- Vol. 58 (6-7) , 595-614
LED array spatial frequency impacts discomfort and afterimages in a simulated nighttime environment
LED luminaires with apertures containing visually resolvable bright spots are commonly used to illuminate outdoor environments. However, the impact of the distance between LEDs, which determines spatial frequency at a given viewing distance, on perceived discomfort caused by these luminaires remains unclear. This study involved 29 participants who were shown 68 stimuli varying in spatial frequency, intensity, diffusion level and ambient lighting in a dark laboratory setting. Participants reported their experiences of discomfort from glare, ability to resolve individual LEDs and afterimages. The findings revealed that increased spatial frequency heightened both discomfort and the likelihood of experiencing afterimages. It is hypothesized that the point spread function of the eye contributed to these effects, where sources began to be perceived as a single larger source with equal or greater intensity. These results suggest that LED luminaire designs should favour configurations with lower spatial frequencies to minimize discomfort. A simple quantity, direct illuminance at the eye, is recommended for use to predict discomfort from glare because it performed like other more complex models.
- Open Access
- 30 September 2025
- Published by Office of Scientific and Technical Information (OSTI)
The Effect of Luminance Pattern on Nighttime Discomfort Glare Response (CRADA Final Report)
LED luminaires with apertures containing visually resolvable “bright” (i.e., high luminance) spots are commonly used to illuminate outdoor environments. However, the impact of the distance between LEDs, which determines spatial frequency at a given viewing distance, on perceived discomfort caused by these luminaires remains unclear. This study involved 29 participants who were each shown 68 stimuli varying in spatial frequency, intensity, diffusion level, and ambient lighting in a dark laboratory setting. Participants reported their experiences of discomfort from glare, ability to resolve individual LEDs, and afterimages. The findings revealed that increased spatial frequency heightened both discomfort and the likelihood of experiencing afterimages. It is hypothesized that the point spread function of the eye contributed to these effects, where sources began to be perceived as a single larger source with equal or greater intensity. These results suggest that LED luminaire designs should favor configurations with lower spatial frequencies to minimize discomfort. A simple quantity, direct illuminance at the eye, is recommended for use to predict discomfort from glare because it performed like other more complex models.
- 30 September 2025
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessThe Effect of Luminance Pattern on Nighttime Discomfort Glare Response (CRADA Final Report)
LED luminaires with apertures containing visually resolvable “bright” (i.e., high luminance) spots are commonly used to illuminate outdoor environments. However, the impact of the distance between LEDs, which determines spatial frequency at a given viewing distance, on perceived discomfort caused by these luminaires remains unclear. This study involved 29 participants who were each shown 68 stimuli varying in spatial frequency, intensity, diffusion level, and ambient lighting in a dark laboratory setting. Participants reported their experiences of discomfort from glare, ability to resolve individual LEDs, and afterimages. The findings revealed that increased spatial frequency heightened both discomfort and the likelihood of experiencing afterimages. It is hypothesized that the point spread function of the eye contributed to these effects, where sources began to be perceived as a single larger source with equal or greater intensity. These results suggest that LED luminaire designs should favor configurations with lower spatial frequencies to minimize discomfort. A simple quantity, direct illuminance at the eye, is recommended for use to predict discomfort from glare because it performed like other more complex models.
- 9 January 2025
- Published by Taylor & Francis in LEUKOS
- p. 1-23
Relative Contributions of sc-DER, mel-DER, Color Rendition, Chromaticity, and Illuminance to Spatial Brightness Perception
- 9 January 2025
- Published by Taylor & Francis in LEUKOS
- p. 1-23
Relative Contributions of sc-DER, mel-DER, Color Rendition, Chromaticity, and Illuminance to Spatial Brightness Perception
- 20 December 2024
- Published by SAGE Publications in Lighting Research & Technology
Pupil obscuration mediates the impact of an overhead glare source
Interindividual variability in discomfort from glare has been documented in previous studies, but the causes are not well understood. An observer-related factor that contributes to the variation in perceived glare across individuals is the portion of the face exposed to direct illumination, which is influenced by facial geometry. We hypothesized that individuals with a shaded pupil (due to deeply recessed pupils within the eye socket) would tolerate higher luminance for an overhead glare source compared to individuals with an unshaded pupil. To test this hypothesis, an experiment was conducted where the facial models of 29 participants were collected using a 3D scanner. Participants were seated at a spherical apparatus and asked to set the luminance of a light source positioned 60° above the line of sight using matching and adjustment procedures. For a source positioned 60° above the line of sight, participants with an unshaded pupil set the borderline between comfort and discomfort luminance to a significantly lower value compared to those with a shaded pupil. This can inform more inclusive lighting design guidelines by considering individuals who are likely more sensitive to overhead sources due to their facial geometry.
- 20 December 2024
- Published by SAGE Publications in Lighting Research & Technology
Pupil obscuration mediates the impact of an overhead glare source
Interindividual variability in discomfort from glare has been documented in previous studies, but the causes are not well understood. An observer-related factor that contributes to the variation in perceived glare across individuals is the portion of the face exposed to direct illumination, which is influenced by facial geometry. We hypothesized that individuals with a shaded pupil (due to deeply recessed pupils within the eye socket) would tolerate higher luminance for an overhead glare source compared to individuals with an unshaded pupil. To test this hypothesis, an experiment was conducted where the facial models of 29 participants were collected using a 3D scanner. Participants were seated at a spherical apparatus and asked to set the luminance of a light source positioned 60° above the line of sight using matching and adjustment procedures. For a source positioned 60° above the line of sight, participants with an unshaded pupil set the borderline between comfort and discomfort luminance to a significantly lower value compared to those with a shaded pupil. This can inform more inclusive lighting design guidelines by considering individuals who are likely more sensitive to overhead sources due to their facial geometry.
- Open Access
- 9 November 2024
- Published by Elsevier in Journal of Environmental Psychology
- Vol. 100
Effects of near-infrared radiation in ambient lighting on cognitive performance, emotion, and heart rate variability
- 9 November 2024
- Published by Elsevier in Journal of Environmental Psychology
- Vol. 100
Open AccessEffects of near-infrared radiation in ambient lighting on cognitive performance, emotion, and heart rate variability
- 21 October 2024
- Published by SAGE Publications in Lighting Research & Technology
- Vol. 56 (7) , 676-706
Visibility and annoyance of the phantom array effect varies with age and history of migraine
The phantom array effect (PAE) is a series of repeated images that may be perceived when a person moves their eyes in large saccades across a light source (or a specular reflection of that light source) that is modulating in output over time. Fifty-five people, including a group of 25 who experience migraine, evaluated the visibility and annoyingness of phantom arrays produced by 85 unique temporal light modulation waveforms (including sine, rectangular, complex and DC waveforms) generated using an LED placed against a black background. Those with migraine exhibited higher average visibility compared to those without migraine ( p = 0.019) and were relatively more sensitive at higher frequencies ( p < 0.001). Younger participants also found more stimuli to be visible ( p < 0.001). The threshold sensitivity function was similar to that developed for the phantom array visibility measure (PAVM), and PAVM was effective in predicting visibility ( R2 = 0.87 for the relevant region of PAVM < 3). While those in the migraine group did not report seeing the PAE more often in everyday life at a statistically significant level, they reported being more annoyed by it and having more unwanted physiological responses (headaches, eye fatigue and distraction/disorientation). Members of the migraine group were also more likely to have changed their behaviour in architectural spaces (such as leaving a restaurant with ‘flickering’ lights). In the four hours after completing the experiment, 64% of the migraine group (vs. 19% of the non-migraine group) reported experiencing discomfort or an adverse reaction. In particular, 41% reported experiencing a headache (vs. 8% for those in the non-migraine group).
- 21 October 2024
- Published by SAGE Publications in Lighting Research & Technology
- Vol. 56 (7) , 676-706
Visibility and annoyance of the phantom array effect varies with age and history of migraine
The phantom array effect (PAE) is a series of repeated images that may be perceived when a person moves their eyes in large saccades across a light source (or a specular reflection of that light source) that is modulating in output over time. Fifty-five people, including a group of 25 who experience migraine, evaluated the visibility and annoyingness of phantom arrays produced by 85 unique temporal light modulation waveforms (including sine, rectangular, complex and DC waveforms) generated using an LED placed against a black background. Those with migraine exhibited higher average visibility compared to those without migraine ( p = 0.019) and were relatively more sensitive at higher frequencies ( p < 0.001). Younger participants also found more stimuli to be visible ( p < 0.001). The threshold sensitivity function was similar to that developed for the phantom array visibility measure (PAVM), and PAVM was effective in predicting visibility ( R2 = 0.87 for the relevant region of PAVM < 3). While those in the migraine group did not report seeing the PAE more often in everyday life at a statistically significant level, they reported being more annoyed by it and having more unwanted physiological responses (headaches, eye fatigue and distraction/disorientation). Members of the migraine group were also more likely to have changed their behaviour in architectural spaces (such as leaving a restaurant with ‘flickering’ lights). In the four hours after completing the experiment, 64% of the migraine group (vs. 19% of the non-migraine group) reported experiencing discomfort or an adverse reaction. In particular, 41% reported experiencing a headache (vs. 8% for those in the non-migraine group).
- 17 April 2024
- Published by Taylor & Francis in LEUKOS
- Vol. 21 (1) , 65-82
The Position Index of Overhead LED Sources Under Different Spectral Power Distributions and Background Luminances
- 17 April 2024
- Published by Taylor & Francis in LEUKOS
- Vol. 21 (1) , 65-82
The Position Index of Overhead LED Sources Under Different Spectral Power Distributions and Background Luminances