Shih-Hsing Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shih-Hsing Yang has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Chin-Pyng Wu
Department of Critical Care Medicine, Landseed International Hospital, Tao-Yuan, Taiwan
2 shared publications - Huey Dong Wu
Department of Integrated Diagnostics & Therapeutics, National Taiwan University Hospital, Taipei City, Taiwan
2 shared publications Shwu Jen Lin
Department of Integrated Diagnostics & Therapeutics, National Taiwan University Hospital, Taipei City, Taiwan; Master Program in Transdisciplinary Long-Term Care, Fu Jen Catholic University, New Taipei City, Taiwan
2 shared publications- Yao-Wen Kuo
Department of Integrated Diagnostics & Therapeutics, National Taiwan University Hospital, Taipei City, Taiwan
2 shared publications - Chao-Yu Chen
Fu Jen Catholic University
1 shared publication Chi-Chien Chen
Department of Chest Medicine, Tung Jen Hospital, New Taipei City, Taiwan, ROC
1 shared publication
Latest Publications
- 30 September 2026
- Published by SAGE Publications in Respiratory Care
Unsupervised Clustering Analysis of Snoring Identifies Acoustic Biomarkers for the Severity of Obstructive Sleep Apnea
Background: Obstructive sleep apnea (OSA) is a prevalent public health concern linked to cardiovascular, metabolic, and neurocognitive consequences. Although polysomnography (PSG) is the diagnostic standard, the availability can be limited with long wait time. Snoring is a common symptom of OSA, but all individuals with snoring do not have OSA. In this study, we hypothesized the characteristics of snoring may be used to detect OSA. We applied an unsupervised clustering method to classify snoring patterns and examine their correlations with OSA parameters. Methods: We enrolled 287 adults with snoring symptoms who underwent overnight PSG at 2 teaching hospitals in Taiwan. Snoring sounds were recorded, and the dominant frequency and loudness were analyzed. A K-means clustering model was first developed using a training cohort ( n = 50) and applied to classify frequency patterns into 5 clusters. Each cluster was further divided into 2 subclusters based on a loudness threshold (70 dB). An independent validation cohort ( n = 237) was used to develop an apnea-hypopnea index (AHI) prediction model and evaluate discriminative performance using receiver operating characteristic analysis. Results: Clusters 1, 2, and 5 were significantly associated with higher AHI, oxygen desaturation index, and apnea index. In contrast, clusters 3 and 4 showed little or no association. An AHI prediction model was developed using age, BMI, and significant acoustic clusters. For PSG-defined OSA thresholds of AHI ≥ 5, ≥15, and ≥30 events/h, the AUC values were 0.90, 0.83, and 0.82, respectively, with sensitivity ranging from 70.5% to 77.5% and specificity ranging from 73.7% to 100%. Conclusions: Our study demonstrates an AI-based clustering analysis of snoring patterns can be used to evaluate OSA severity. The snoring pattern analysis can also be an additional screening tool for OSA.
- 30 September 2026
- Published by SAGE Publications in Respiratory Care
Unsupervised Clustering Analysis of Snoring Identifies Acoustic Biomarkers for the Severity of Obstructive Sleep Apnea
Background: Obstructive sleep apnea (OSA) is a prevalent public health concern linked to cardiovascular, metabolic, and neurocognitive consequences. Although polysomnography (PSG) is the diagnostic standard, the availability can be limited with long wait time. Snoring is a common symptom of OSA, but all individuals with snoring do not have OSA. In this study, we hypothesized the characteristics of snoring may be used to detect OSA. We applied an unsupervised clustering method to classify snoring patterns and examine their correlations with OSA parameters. Methods: We enrolled 287 adults with snoring symptoms who underwent overnight PSG at 2 teaching hospitals in Taiwan. Snoring sounds were recorded, and the dominant frequency and loudness were analyzed. A K-means clustering model was first developed using a training cohort ( n = 50) and applied to classify frequency patterns into 5 clusters. Each cluster was further divided into 2 subclusters based on a loudness threshold (70 dB). An independent validation cohort ( n = 237) was used to develop an apnea-hypopnea index (AHI) prediction model and evaluate discriminative performance using receiver operating characteristic analysis. Results: Clusters 1, 2, and 5 were significantly associated with higher AHI, oxygen desaturation index, and apnea index. In contrast, clusters 3 and 4 showed little or no association. An AHI prediction model was developed using age, BMI, and significant acoustic clusters. For PSG-defined OSA thresholds of AHI ≥ 5, ≥15, and ≥30 events/h, the AUC values were 0.90, 0.83, and 0.82, respectively, with sensitivity ranging from 70.5% to 77.5% and specificity ranging from 73.7% to 100%. Conclusions: Our study demonstrates an AI-based clustering analysis of snoring patterns can be used to evaluate OSA severity. The snoring pattern analysis can also be an additional screening tool for OSA.
- Open Access
- 17 March 2026
- Published by Elsevier in Journal of the Formosan Medical Association
A longitudinal study of ventilator-dependent patients in Taiwan
- 17 March 2026
- Published by Elsevier in Journal of the Formosan Medical Association
Open AccessA longitudinal study of ventilator-dependent patients in Taiwan
- Open Access
- 23 September 2025
- Published by Elsevier in Journal of the Formosan Medical Association
- Vol. 125 (8) , 964-970
The association between pre-discharge factors and early unplanned readmissions in adult home mechanical ventilation patients in Taiwan
- 23 September 2025
- Published by Elsevier in Journal of the Formosan Medical Association
- Vol. 125 (8) , 964-970
Open AccessThe association between pre-discharge factors and early unplanned readmissions in adult home mechanical ventilation patients in Taiwan
- Open Access
- 7 March 2025
- Published by Wiley in The Clinical Respiratory Journal
- Vol. 19 (3) , e70058
Bacterial Colonization of Silver‐Additive Ventilator Circuit in Patients Receiving Mechanical Ventilation: A Randomized Controlled Trial
Introduction: Mechanical ventilation is a significant risk factor for developing ventilator‐associated pneumonia. Although silver‐coated endotracheal tubes have been shown to reduce the bacterial burden, the efficacy of silver‐based ion additive ventilator circuits in reducing bacterial colonization remains unclear.Methods: This single‐site, randomized controlled trial compared the incidence of bacterial contamination between a silver‐additive ventilator circuit and a ventilator circuit that did not have a silver additive. Bacterial samples were collected from the inspiratory limb and Y‐adaptor of the circuit and analyzed using culture and identification methods.Results: Bacterial growth was observed in all samples from the control group and in 93.7% and 81.2% of inspiratory limb and Y‐adaptor samples, respectively, from the study group. The colony counts in the inspiratory limb samples were significantly different between the groups, with a higher proportion of undesirable colony counts in the control group compared with the study group. No significant difference between the groups was observed in the colony counts in the Y‐adaptor samples.Conclusion: The use of a silver‐additive ventilator circuit may reduce bacterial circuit colonization. However, further research with larger sample sizes and more diverse patient populations is necessary to confirm these findings.Trial Registration: ClinicalTrial.gov: NCT04927806
- 7 March 2025
- Published by Wiley in The Clinical Respiratory Journal
- Vol. 19 (3) , e70058
Open AccessBacterial Colonization of Silver‐Additive Ventilator Circuit in Patients Receiving Mechanical Ventilation: A Randomized Controlled Trial
Introduction: Mechanical ventilation is a significant risk factor for developing ventilator‐associated pneumonia. Although silver‐coated endotracheal tubes have been shown to reduce the bacterial burden, the efficacy of silver‐based ion additive ventilator circuits in reducing bacterial colonization remains unclear.Methods: This single‐site, randomized controlled trial compared the incidence of bacterial contamination between a silver‐additive ventilator circuit and a ventilator circuit that did not have a silver additive. Bacterial samples were collected from the inspiratory limb and Y‐adaptor of the circuit and analyzed using culture and identification methods.Results: Bacterial growth was observed in all samples from the control group and in 93.7% and 81.2% of inspiratory limb and Y‐adaptor samples, respectively, from the study group. The colony counts in the inspiratory limb samples were significantly different between the groups, with a higher proportion of undesirable colony counts in the control group compared with the study group. No significant difference between the groups was observed in the colony counts in the Y‐adaptor samples.Conclusion: The use of a silver‐additive ventilator circuit may reduce bacterial circuit colonization. However, further research with larger sample sizes and more diverse patient populations is necessary to confirm these findings.Trial Registration: ClinicalTrial.gov: NCT04927806
- Open Access
- 9 March 2022
- Published by Springer Nature in Research Square
Pre-discharge factors associated with unplanned readmission of patients with home mechanical ventilation: a retrospective study
Exploring the characteristics and prognosis of unplanned readmissions of patients using a home ventilator and analyzing relevant pre-discharge factors that affect such unplanned readmissions.A retrospective study was conducted to collect medical record data for 2013–2017 on the readmission of home-ventilated patients in a medical center in northern Taiwan. The average intervals of home care for the early readmission group (≤ 30 days) and the late readmission group (≥ 31 days) were 15.1 ± 9.2 and 164.8 ± 143.2 days, respectively. Regarding risk factors of early and late unplanned hospital readmission, the odds ratio (OR) for patients with chronic cardiovascular disease compared with those without this disease was 4.535 (95% CI 1.253 -16.413). For maximum inspiratory pressure ≦ −30 cmH2O compared with > −30 cmH2O, the OR for early readmission was 0.207 (95% CI 0.056 - 0.767). For hemoglobin ≥ 10.1 g/dL compared with < 10.1 g/dL, the OR of early readmission was 0.280 (95% CI 0.082 - 0.958). So, pre-discharge problems, including chronic cardiovascular disease, maximum inspiratory pressure, and reduced hemoglobin, are risk factors for unplanned early hospitalization readmission of patients using a ventilator at home. Therefore, attention should be paid to these risk factors during discharge planning.
- 9 March 2022
- Published by Springer Nature in Research Square
Open AccessPre-discharge factors associated with unplanned readmission of patients with home mechanical ventilation: a retrospective study
Exploring the characteristics and prognosis of unplanned readmissions of patients using a home ventilator and analyzing relevant pre-discharge factors that affect such unplanned readmissions.A retrospective study was conducted to collect medical record data for 2013–2017 on the readmission of home-ventilated patients in a medical center in northern Taiwan. The average intervals of home care for the early readmission group (≤ 30 days) and the late readmission group (≥ 31 days) were 15.1 ± 9.2 and 164.8 ± 143.2 days, respectively. Regarding risk factors of early and late unplanned hospital readmission, the odds ratio (OR) for patients with chronic cardiovascular disease compared with those without this disease was 4.535 (95% CI 1.253 -16.413). For maximum inspiratory pressure ≦ −30 cmH2O compared with > −30 cmH2O, the OR for early readmission was 0.207 (95% CI 0.056 - 0.767). For hemoglobin ≥ 10.1 g/dL compared with < 10.1 g/dL, the OR of early readmission was 0.280 (95% CI 0.082 - 0.958). So, pre-discharge problems, including chronic cardiovascular disease, maximum inspiratory pressure, and reduced hemoglobin, are risk factors for unplanned early hospitalization readmission of patients using a ventilator at home. Therefore, attention should be paid to these risk factors during discharge planning.
- Open Access
- 19 September 2021
- Published by MDPI AG in Healthcare
- Vol. 9 (9) , 1235
Impact of Oxygen Concentration Delivered via Nasal Cannula on Different Lung Conditions: A Bench Study
Background: Measuring the fraction of inspired oxygen (FiO2) is challenging in spontaneously breathing patients with impaired respiratory mechanics during low-flow nasal cannula. Our study investigates the FiO2 with varied tidal volume (VT) and respiratory rate (RR) among different lung mechanics and provides equations to estimate the FiO2. Methods: Two training and test lungs were used in this study, and the three lung mechanics (normal (R5/C60), restrictive (R20/C80), obstructive (R5/C40)) were designed. Spontaneous breathing with VT (300, 500, and 700 mL) and RR (10, 20, and 30 breaths/min) was simulated. The flow rate of the nasal cannula was set to 1, 3, and 5 L per minute (LPM), and the FiO2 was measured at the carina. Results: The lowest and highest FiO2 were evident during high (700 mL) and low VT (300 mL), respectively, among normal, restrictive, and obstructive lung models. As RR increases, this decreases the FiO2. However, we found that VT and oxygen flow rate are the principal factors influencing measured FiO2 by multiple linear regression analysis. Conclusions: Our data suggest that the actual FiO2 is never as high in spontaneously breathing patients as that estimated. VT and oxygen flow rate had a substantial impact on the FiO2.
- 19 September 2021
- Published by MDPI AG in Healthcare
- Vol. 9 (9) , 1235
Open AccessImpact of Oxygen Concentration Delivered via Nasal Cannula on Different Lung Conditions: A Bench Study
Background: Measuring the fraction of inspired oxygen (FiO2) is challenging in spontaneously breathing patients with impaired respiratory mechanics during low-flow nasal cannula. Our study investigates the FiO2 with varied tidal volume (VT) and respiratory rate (RR) among different lung mechanics and provides equations to estimate the FiO2. Methods: Two training and test lungs were used in this study, and the three lung mechanics (normal (R5/C60), restrictive (R20/C80), obstructive (R5/C40)) were designed. Spontaneous breathing with VT (300, 500, and 700 mL) and RR (10, 20, and 30 breaths/min) was simulated. The flow rate of the nasal cannula was set to 1, 3, and 5 L per minute (LPM), and the FiO2 was measured at the carina. Results: The lowest and highest FiO2 were evident during high (700 mL) and low VT (300 mL), respectively, among normal, restrictive, and obstructive lung models. As RR increases, this decreases the FiO2. However, we found that VT and oxygen flow rate are the principal factors influencing measured FiO2 by multiple linear regression analysis. Conclusions: Our data suggest that the actual FiO2 is never as high in spontaneously breathing patients as that estimated. VT and oxygen flow rate had a substantial impact on the FiO2.
- Open Access
- 6 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (11) , 5266
Closed Endotracheal Suctioning Impact on Ventilator-Related Parameters in Obstructive and Restrictive Respiratory Systems: A Bench Study
A closed suctioning system (CSS) in patients with coronavirus disease 2019 (COVID-19) prevents spraying respiratory secretions into the environment during suction. However, it is not clear whether ventilation is maintained during the suction procedure, especially in patients with compromised pulmonary mechanics. This paper determines the effects of endotracheal tube (ETT) size, suction catheter size, and two lung mechanics (resistance and compliance) on ventilator-related parameters measured during suction. Suction was performed on an adult training lung, ventilated with either volume-controlled (VC-CMV) or pressure-controlled mandatory ventilation (PC-CMV), using ETT sizes of 6.5–8.0 mm paired with suction catheter sizes of 8–14 French (Fr). Peak inspiratory pressure (PIP) increased by 50% when the ETT’s ventilation area was less than 25 mm2 in size, especially in patients with high airway resistance ventilated with VC-CMV. Positive end-expiratory pressure (PEEP) levels significantly decreased when using 14 Fr SC during VC-CMV and fewer effects during PC-CMV. Change of expiratory minute volume increased with higher outer diameter of suction catheters and decreased with severe lung compliance during PC-CMV. The change in ventilator-related parameters were intently monitored in the patient whose pulmonary mechanic was compromised through the CSS endotracheal tube suctioning procedures in clinical airway management.
- 6 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (11) , 5266
Open AccessClosed Endotracheal Suctioning Impact on Ventilator-Related Parameters in Obstructive and Restrictive Respiratory Systems: A Bench Study
A closed suctioning system (CSS) in patients with coronavirus disease 2019 (COVID-19) prevents spraying respiratory secretions into the environment during suction. However, it is not clear whether ventilation is maintained during the suction procedure, especially in patients with compromised pulmonary mechanics. This paper determines the effects of endotracheal tube (ETT) size, suction catheter size, and two lung mechanics (resistance and compliance) on ventilator-related parameters measured during suction. Suction was performed on an adult training lung, ventilated with either volume-controlled (VC-CMV) or pressure-controlled mandatory ventilation (PC-CMV), using ETT sizes of 6.5–8.0 mm paired with suction catheter sizes of 8–14 French (Fr). Peak inspiratory pressure (PIP) increased by 50% when the ETT’s ventilation area was less than 25 mm2 in size, especially in patients with high airway resistance ventilated with VC-CMV. Positive end-expiratory pressure (PEEP) levels significantly decreased when using 14 Fr SC during VC-CMV and fewer effects during PC-CMV. Change of expiratory minute volume increased with higher outer diameter of suction catheters and decreased with severe lung compliance during PC-CMV. The change in ventilator-related parameters were intently monitored in the patient whose pulmonary mechanic was compromised through the CSS endotracheal tube suctioning procedures in clinical airway management.
- Open Access
- 16 April 2021
- Published by SAGE Publications in SIMULATION
- Vol. 97 (7) , 439-449
Optimizing effects on airway pressure and minute volume during closed endotracheal suctioning: a simulated lung model
A closed suction system is used to remove endotracheal secretions without interrupting the patient’s ventilation. Closed suctioning may reduce adverse effects associated with suctioning with, for example, decreased clinical signs of hypoxemia and limited environmental, personnel, and patient contamination. However, it is not clear whether ventilation is maintained during the procedure. We aimed to determine the effects of endotracheal tube (ETT) size, suction catheter (SC) size, and SC length in the ETT on ventilation parameters measured during suction. Suction was performed on a test lung, ventilated with either volume-controlled continuous mandatory ventilation (VC-CMV) or pressure-controlled continuous mandatory ventilation (PC-CMV) using ETT sizes of 6.0–8.5 mm paired with SC sizes of 8–16 French gauge (Fr = 0.33 mm). Airway resistance ( Raw), peak inspiratory pressure (PIP), positive end-expiratory pressure (PEEP), and expiratory minute volume ( Vexp) were recorded for each ventilation episode by a HAMILTON-G5 ventilator. Here, Raw was considerably increased by insertion of the SC into the ETT. This Raw effect altered the PIP and Vexp. PIP was increased in VC-CMV because the ventilation area of the ETT was reduced, and Vexp was decreased in PC-CMV in relation to the size of the SC. PEEP decreased with application of the 16 Fr SC and 30 L/min flow rate in VC-CMV. We conclude that airway pressure and minute volume are not maintained during closed endotracheal suctioning with VC-CMV and PC-CMV, respectively. The degree of interference to ventilation is affected through selection of appropriate SC size and ventilation settings.
- 16 April 2021
- Published by SAGE Publications in SIMULATION
- Vol. 97 (7) , 439-449
Open AccessOptimizing effects on airway pressure and minute volume during closed endotracheal suctioning: a simulated lung model
A closed suction system is used to remove endotracheal secretions without interrupting the patient’s ventilation. Closed suctioning may reduce adverse effects associated with suctioning with, for example, decreased clinical signs of hypoxemia and limited environmental, personnel, and patient contamination. However, it is not clear whether ventilation is maintained during the procedure. We aimed to determine the effects of endotracheal tube (ETT) size, suction catheter (SC) size, and SC length in the ETT on ventilation parameters measured during suction. Suction was performed on a test lung, ventilated with either volume-controlled continuous mandatory ventilation (VC-CMV) or pressure-controlled continuous mandatory ventilation (PC-CMV) using ETT sizes of 6.0–8.5 mm paired with SC sizes of 8–16 French gauge (Fr = 0.33 mm). Airway resistance ( Raw), peak inspiratory pressure (PIP), positive end-expiratory pressure (PEEP), and expiratory minute volume ( Vexp) were recorded for each ventilation episode by a HAMILTON-G5 ventilator. Here, Raw was considerably increased by insertion of the SC into the ETT. This Raw effect altered the PIP and Vexp. PIP was increased in VC-CMV because the ventilation area of the ETT was reduced, and Vexp was decreased in PC-CMV in relation to the size of the SC. PEEP decreased with application of the 16 Fr SC and 30 L/min flow rate in VC-CMV. We conclude that airway pressure and minute volume are not maintained during closed endotracheal suctioning with VC-CMV and PC-CMV, respectively. The degree of interference to ventilation is affected through selection of appropriate SC size and ventilation settings.
- 1 June 2017
- Published by Elsevier in Journal of Critical Care
- Vol. 39, 178-181
Correlation between transition percentage of minute volume (TMV%) and outcome of patients with acute respiratory failure
- 1 June 2017
- Published by Elsevier in Journal of Critical Care
- Vol. 39, 178-181
Correlation between transition percentage of minute volume (TMV%) and outcome of patients with acute respiratory failure