Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Konstantinos Dimitriadis has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Mechanically Robust Porous Ceramic Substrates Wash‐Coated With Cu/CeO 2 Nanoparticles for Redox Catalytic Applications

    by Konstantinos Dimitriadis, Evridiki Mandela, Maria Lykaki, Ilias Georgiopoulos, Agapi Orfanoudaki, George Ε. Marnellos, Michalis Konsolakis, Constantina‐Dia Andreouli

    The development of structured ceramic catalysts capable of operating under both oxidative and reductive environments is critical for advanced energy and environmental applications. In this work, macrostructured ceramic supports were designed and wash‐coated with rod‐like Cu/CeO 2 nanoparticles to meet industrial requirements, including flexural strength above 15 MPa, open porosity exceeding 45%, and high thermal shock resistance. Porous substrates based on zircon‐mullite (ZM), sodium zirconium phosphates (NaZr 2 P 3 O 12 ; NZP), and cordierite (Cor) compositions were fabricated through the controlled addition of yttria‐stabilized zirconia (YSZ) and a sacrificial wax pore former, enabling the simultaneous optimization of mechanical strength and porous architecture. Thermal expansion analysis, phase and crystallographic characterization, and three‐point bending tests demonstrated that optimized compositions achieved the targeted balance of properties, with Weibull analysis confirming their mechanical reliability. Wash‐coating resulted in a uniform distribution of rod‐like Cu/CeO 2 nanoparticles throughout the porous networks, showing excellent adhesion and stability after exposure to CO oxidation and CO 2 hydrogenation conditions. Catalytic tests revealed that structured catalysts containing 10 wt.% active phase exhibited higher intrinsic activity and more efficient catalyst utilization compared with the corresponding powder catalyst. Overall, the developed systems show strong potential as robust, cost‐effective, and high‐performance structured catalysts for industrial applications.

  • Glass-ceramics and glass-ceramic/zirconia composites for dental applications: Synthesis, fabrication and characterization

    by Konstantinos Dimitriadis, Christina Gioti, Marios Constantinou, Ilias Georgiopoulos, Georgios Constantinides, Constantina-Dia Andreouli, Michael A. Karakassides, Simeon Agathopoulos

  • Development and Evaluation of Glass‐Ceramics and Glass‐Ceramic/Zirconia Composites for Dental Fixed Applications

    by Konstantinos Dimitriadis, Christina Gioti, Marios Constantinou, Ilias Georgiopoulos, Georgios Constantinides, Constantina‐Dia Andreouli, Michael A. Karakassides, Dilshat U. Tulyaganov, Simeon Agathopoulos

    This study presents a novel class of glass‐ceramics (GCs) and GC/zirconia composites designed for dental applications, developed within the CaO‐MgO‐SiO 2 ternary system through the synergistic addition of 3.40 wt.% Al 2 O 3 and 25 wt.% 3Y‐TZP. This combined reinforcement strategy effectively enhances mechanical reliability while preserving favorable tribological behavior. XRD and SEM/EDS analyses revealed well‐defined crystalline assemblages, consisting of diopside, wollastonite, and zirconium yttrium oxide in K‐free systems and diopside, α‐potassium magnesium silicate, and zirconium yttrium oxide in K‐containing materials. The incorporation of 3Y‐TZP significantly improved flexural strength and Weibull modulus, indicating increased structural reliability, while maintaining coefficients of dynamic friction comparable to dental enamel. All developed materials meet the flexural strength requirements of ISO 6872, supporting their suitability for dental fixed restorations. Moreover, their mechanical properties closely resemble those of natural dentine and enamel, ensuring harmonious interaction with surrounding hard tissues without causing injury. Brittleness index values further confirm their suitability for CAD/CAM processing, highlighting the strong potential of these novel GCs and GC/zirconia composites as next‐generation dental restorative materials.

  • Bioactive Glass-Ceramic/ZrO2 Composites for Dental Implant Applications

    by Konstantinos Dimitriadis, Christina Gioti, Ilias Georgiopoulos, Marios Constantinou, Georgios Constantinides, Constantina-Dia Andreouli, Michael A. Karakassides, Simeon Agathopoulos


  • Open Access

    Effect of Framework Orientation at a Selective Laser Melting Building Platform on Removable Partial Denture Fit

    by Vasileios K. Vergos, Antonios L. Theocharopoulos, Konstantinos Dimitriadis, Stavros A. Yannikakis

    Objectives: This in vitro study aimed to evaluate the effects of three framework orientation (FO) positions on an SLM building platform (Horizontal [H], Diagonal-45° [D45°], Diagonal-60° [D60°]) and two designs (with [B] or without [NB] stabilizing bars) on the fitting accuracy of digitally fabricated Co-Cr RPD frameworks. Materials and Methods: A custom RPD framework CAD was performed on a 3D-printed resin-model of an edentulous maxilla with three geometric tooth forms. A Co-Cr alloy was processed via SLM processing into 24 framework specimens, divided into three FO groups (n = 8: H, D45°, D60°) and two subgroups each (n = 4: B, NB). Qualitative/quantitative fit-evaluation was assessed using virtual framework-to-model seating and a custom digital protocol with GOM Inspect software (2018-Hotfix5, Rev.115656). Mean fitting distances were calculated from 220 equidistant points per specimen. Statistical comparisons were performed using ANOVA-on-ranks, Kruskal–Wallis multiple comparisons, and Bonferroni adjustment. Results: FO Sub-Group medians (Q1, Q3: 25% and 75% Quartiles) (mm) were: H/NB 0.150 (0.140, 0.164), H/B: 0.136 (0.121, 0.152), D45°/NB: 0.230 (0.219, 0.241), D45°/B: 0.144 (0.137, 0.154), D60°/NB:0.238 (0.232, 0.247), D60°/B: 0.171 (0.166,0.176). Pairwise comparisons indicated the following statistically significant (p < 0.05) FO Sub-Group differences: H/B-D45°/NB, H/B-D60°/NB, D45°/B-D45°/NB, D45°/B-D60°/NB, H/NB-D45°/NB, H/NB- D60°/NB. Conclusions: Horizontal orientation improved RPD fit accuracy regardless of bar presence. D45° accuracy is enhanced by stabilizing bars, while D60° accuracy is unaffected by bar addition.

  • Open Access

    Thermal Analysis and Crystallization of Bioactive Glass “1d” in the SiO2-CaO-MgO-P2O5-CaF2-Na2O Compositional System

    by Valentina Rigano, Dilshat U. Tulyaganov, Konstantinos Dimitriadis, Simeon Agathopoulos, Francesco Baino

    The crystallization behavior of the bioactive silicate glass “1d” was analyzed using non-isothermal conditions through differential scanning calorimetry (DSC). The plots carried out at different heating rates showed only one crystallization peak. The activation energy for crystallization was calculated through the equations proposed in the Kissinger and Matusita–Sakka models. The Johnson–Mehl–Avrami coefficient (n) was estimated by applying Ozawa and Augis–Bennet methods, resulting in a two-dimensional crystal growth. Crystalline phases which developed during high-temperature treatment were analyzed by X-ray diffraction and scanning electron microscopy. The activation energy for viscous flow was estimated to be 513 kJ/mol, which is lower than the activation energy for crystallization (539 kJ/mol). The Malek test highlighted that the crystallization process was more complex than a simple nucleation-growth mechanism. The sinterability parameter and Hruby coefficient showed the high stability of 1d glass against crystallization, which makes this bioactive material highly appealing for producing well-sintered products of biomedical interest, such as bioactive porous scaffolds for bone regeneration.

  • Open Access

    Implant‐cemented Co–Cr frameworks produced by hard and soft milling: The impact of porcelain firing cycles on microstructure and fit accuracy

    by Michael Nikolopoulos, Konstantinos Dimitriadis, Stavros Yannikakis, Athanasios K. Sfikas, Aristidis Galiatsatos, Pepie Tsolka

    This study examines how porcelain firing cycles and fabrication methods impact the microstructure and the marginal and internal fit of implant‐cemented Co–Cr frameworks. Two fabrication processes for Co–Cr specimens were used: hard milling or soft milling. Each type of framework was then allocated to use either as‐fabricated or as porcelain‐fired. The microstructural analysis employed x‐ray diffraction (XRD) and scanning electron microscopy with energy‐dispersive x‐ray spectroscopy (SEM/EDX). A total of ten Co–Cr frameworks were fabricated for each method, and discrepancies in margin and internal fit were evaluated using X‐ray microtomography (micro‐CT) before and after the porcelain firing. Statistical analysis was performed using two‐way ANOVA and Tukey's multiple comparison tests (α = 0.05). The findings indicated a combination of γ‐fcc and ε‐hcp cobalt‐based phases, with porcelain firing notably enhancing the ε‐Co content, particularly among soft milled specimens. Soft milled specimens exhibited a diffuse presence of pores, while hard milled specimens revealed a random distribution of small pores. The soft milled specimens exhibited a significant reduction in discrepancies after the application of firing cycles. Although not statistically significant, the hard milled specimens also showed a trend toward reduced discrepancies post‐firing. All subgroups maintained clinically acceptable marginal adaptation, with soft milled frameworks outperforming their hard milled counterparts in overall fit.


  • Open Access

    Influence of repeated porcelain firing cycles on the microstructure, marginal and internal fit of implant‐cemented Co‐Cr frameworks

    by Michael Nikolopoulos, Konstantinos Dimitriadis, Stavros Yannikakis, Aristidis Galiatsatos, Pepie Tsolka

    This study investigated the effect of porcelain firing cycles and fabrication techniques on the microstructure, marginal, and internal fit of implant‐cemented cobalt‐chromium alloys (Co‐Cr) frameworks. Two groups of Co‐Cr specimens were prepared: one using selective laser melting (SLM) and the other through the lost wax‐casting technique (C). Each group was further divided into two subgroups: as‐manufactured and porcelain‐fired specimens. The microstructure was analyzed using x‐ray diffraction (XRD) and scanning electron microscopy with energy‐dispersive x‐ray spectroscopy (SEM/EDX). Ten Co‐Cr frameworks per manufacturing technique were fabricated, with marginal and internal discrepancies measured using micro‐CT before and after the firing cycles. The results were analyzed by two‐way ANOVA and Tukey multiple‐comparison tests. The results showed a mixed microstructure of γ‐fcc and ε‐hcp cobalt‐based phases, with porcelain firings increasing ε‐Co content, especially in group C. The C specimens exhibited distribution of small pores, while no pores/defects were found in the SLM group. The SLM group, although not at a statistically significant level, showed reduced marginal and internal discrepancy values after firings. In the same behavior pattern, the C group exhibited statistically significantly lower discrepancy values. Ultimately, all subgroups demonstrated clinically acceptable marginal adaptation, but the SLM frameworks exhibited superior marginal and internal fit which remained unaffected by the firing cycles.


  • Open Access

    Fundamentals and advances in production and application of non-stoichiometric lithium disilicate glass-ceramics: A brief review

    by Dilshat U. Tulyaganov, Manuel F.R.P. Alves, Konstantinos Dimitriadis, Saidazim Murtazaev, Simeon Agathopoulos, Hugo R. Fernandes


  • Open Access

    Bond strength and interfacial analysis of six CoCr alloys made by conventional casting and selective laser melting

    by Youssef S. Al Jabbari, Konstantinos Dimitriadis, Aref Sufyan, Spiros Zinelis

    Purpose: To investigate the effects of the elemental composition and the manufacturing process of cobalt chromium–molybdenum (CoCr–Mo), cobalt chromium–tungsten (CoCr–W), and CoCr–Mo‐W alloys on metal–ceramic bond strength. Materials and Methods: Six CoCr‐based alloys were included in this study, a were classified into three different groups depending on their elemental composition ( Ν = 10, for each group). The first group had molybdenum (Mo) as the third alloying element, the second group contained tungsten (W) (without Mo), and the third group included both alloying elements. The groups were further divided by the manufacturing process (casting or selective laser melting, SLM). Interfacial analysis was carried out using backscattered electron imaging (BEI) and energy‐dispersive X‐ray microanalysis (EDX) operating in line scan mode. The metal‐ceramic bond strength was tested by a 3‐point bending test according to the ISO 9693 requirements. The fracture mode of all specimens was examined under a stereomicroscope. The bond strength results were statistically analyzed by 2‐way ANOVA and Tukey's multiple comparison post hoc test ( a = 0.05). Results: A continuous interface with the porcelain was found without pores, debonding areas, or other defects. Of the major elements found at the interface, Co showed the highest diffusion rate, while titanium (Ti) had the lowest diffusion rate. No statistically significant differences were identified in metal‐ceramic bond strength either among materials or between manufacturing processes. The fracture mode was found to be cohesive for all specimens. Conclusions: The metal‐ceramic bond strength is independent of the current CoCr alloy type and manufacturing process when comparing conventional casting and SLM. Interfacial analysis revealed no differences between the tested groups.