Laurent Goffin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Laurent Goffin has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Bernard Bayle
University of Strasbourg, CNRS, INSERM
4 shared publications - André Dufour
Université de Strasbourg, CNRS, LNCA UMR 7364, 12 rue Goethe, F-67000, Strasbourg, France; Université de Strasbourg, CNRS, CI2N UAR 3489, 21 rue Becquerel, F-67000 Strasbourg, France; Institut Universitaire de France (IUF), France
2 shared publications - Chloé Chauvin
HypnoVR Strasbourg France
2 shared publications - Claire Terzulli
HypnoVR Strasbourg France
2 shared publications - Denis Graff
HypnoVR Strasbourg France
2 shared publications - Edouard Laroche
ICube laboratory (UMR CNRS 7357) Universit de Strasbourg, Strasbourg, France
2 shared publications
Latest Publications
- Open Access
- 29 July 2022
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 24 (7) , e33255
Effect of Virtual Reality Hypnosis on Pain Threshold and Neurophysiological and Autonomic Biomarkers in Healthy Volunteers: Prospective Randomized Crossover Study
Background: Virtual reality hypnosis (VRH) is a promising tool to reduce pain. However, the benefits of VRH on pain perception and on the physiological expression of pain require further investigation. Objective: In this study, we characterized the effects of VRH on the heat pain threshold among adult healthy volunteers while monitoring several physiological and autonomic functions. Methods: Sixty healthy volunteers were prospectively included to receive nociceptive stimulations. The first set of thermal stimuli consisted of 20 stimulations at 60°C (duration 500 milliseconds) to trigger contact heat evoked potentials (CHEPs). The second set of thermal stimuli consisted of ramps (1°C/second) to determine the heat pain threshold of the participants. Electrocardiogram, skin conductance responses, respiration rate, as well as the analgesia nociception index were also recorded throughout the experiment. Results: Data from 58 participants were analyzed. There was a small but significant increase in pain threshold in VRH (50.19°C, SD 1.98°C) compared to that in the control condition (mean 49.45°C, SD 1.87; P<.001, Wilcoxon matched-pairs signed-rank test; Cohen d=0.38). No significant effect of VRH on CHEPs and heart rate variability parameters was observed (all P>0.5; n=22 and n=52, respectively). During VRH, participants exhibited a clear reduction in their autonomic sympathetic tone, as shown by the lower number of nonspecific skin conductance peak responses (P<.001, two-way analysis of variance; n=39) and by an increase in the analgesia nociception index (P<.001, paired t-test; n=40). Conclusions: The results obtained in this study support the idea that VRH administration is effective at increasing heat pain thresholds and impacts autonomic functions among healthy volunteers. As a nonpharmacological intervention, VRH has beneficial action on acute experimental heat pain. This beneficial action will need to be evaluated for the treatment of other types of pain, including chronic pain.
- 29 July 2022
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 24 (7) , e33255
Open AccessEffect of Virtual Reality Hypnosis on Pain Threshold and Neurophysiological and Autonomic Biomarkers in Healthy Volunteers: Prospective Randomized Crossover Study
Background: Virtual reality hypnosis (VRH) is a promising tool to reduce pain. However, the benefits of VRH on pain perception and on the physiological expression of pain require further investigation. Objective: In this study, we characterized the effects of VRH on the heat pain threshold among adult healthy volunteers while monitoring several physiological and autonomic functions. Methods: Sixty healthy volunteers were prospectively included to receive nociceptive stimulations. The first set of thermal stimuli consisted of 20 stimulations at 60°C (duration 500 milliseconds) to trigger contact heat evoked potentials (CHEPs). The second set of thermal stimuli consisted of ramps (1°C/second) to determine the heat pain threshold of the participants. Electrocardiogram, skin conductance responses, respiration rate, as well as the analgesia nociception index were also recorded throughout the experiment. Results: Data from 58 participants were analyzed. There was a small but significant increase in pain threshold in VRH (50.19°C, SD 1.98°C) compared to that in the control condition (mean 49.45°C, SD 1.87; P<.001, Wilcoxon matched-pairs signed-rank test; Cohen d=0.38). No significant effect of VRH on CHEPs and heart rate variability parameters was observed (all P>0.5; n=22 and n=52, respectively). During VRH, participants exhibited a clear reduction in their autonomic sympathetic tone, as shown by the lower number of nonspecific skin conductance peak responses (P<.001, two-way analysis of variance; n=39) and by an increase in the analgesia nociception index (P<.001, paired t-test; n=40). Conclusions: The results obtained in this study support the idea that VRH administration is effective at increasing heat pain thresholds and impacts autonomic functions among healthy volunteers. As a nonpharmacological intervention, VRH has beneficial action on acute experimental heat pain. This beneficial action will need to be evaluated for the treatment of other types of pain, including chronic pain.
- 13 July 2022
- Published by Springer Nature in Surgical Endoscopy
- Vol. 36 (12) , 9224-9233
Robotically assisted augmented reality system for identification of targeted lymph nodes in laparoscopic gynecological surgery: a first step toward the identification of sentinel node
Background To prove feasibility of multimodal and temporal fusion of laparoscopic images with preoperative computed tomography scans for a real-time in vivo-targeted lymph node (TLN) detection during minimally invasive pelvic lymphadenectomy and to validate and enable such guidance for safe and accurate sentinel lymph node dissection, including anatomical landmarks in an experimental model. Methods A measurement campaign determined the most accurate tracking system (UR5-Cobot versus NDI Polaris). The subsequent interventions on two pigs consisted of an identification of artificial TLN and anatomical landmarks without and with augmented reality (AR) assistance. The AR overlay on target structures was quantitatively evaluated. The clinical relevance of our system was assessed via a questionnaire completed by experienced and trainee surgeons. Results An AR-based robotic assistance system that performed real-time multimodal and temporal fusion of laparoscopic images with preoperative medical images was developed and tested. It enabled the detection of TLN and their surrounding anatomical structures during pelvic lymphadenectomy. Accuracy of the CT overlay was > 90%, with overflow rates < 6%. When comparing AR to direct vision, we found that scores were significatively higher in AR for all target structures. AR aided both experienced surgeons and trainees, whether it was for TLN, ureter, or vessel identification. Conclusion This computer-assisted system was reliable, safe, and accurate, and the present achievements represent a first step toward a clinical study. Graphical abstract
- 13 July 2022
- Published by Springer Nature in Surgical Endoscopy
- Vol. 36 (12) , 9224-9233
Robotically assisted augmented reality system for identification of targeted lymph nodes in laparoscopic gynecological surgery: a first step toward the identification of sentinel node
Background To prove feasibility of multimodal and temporal fusion of laparoscopic images with preoperative computed tomography scans for a real-time in vivo-targeted lymph node (TLN) detection during minimally invasive pelvic lymphadenectomy and to validate and enable such guidance for safe and accurate sentinel lymph node dissection, including anatomical landmarks in an experimental model. Methods A measurement campaign determined the most accurate tracking system (UR5-Cobot versus NDI Polaris). The subsequent interventions on two pigs consisted of an identification of artificial TLN and anatomical landmarks without and with augmented reality (AR) assistance. The AR overlay on target structures was quantitatively evaluated. The clinical relevance of our system was assessed via a questionnaire completed by experienced and trainee surgeons. Results An AR-based robotic assistance system that performed real-time multimodal and temporal fusion of laparoscopic images with preoperative medical images was developed and tested. It enabled the detection of TLN and their surrounding anatomical structures during pelvic lymphadenectomy. Accuracy of the CT overlay was > 90%, with overflow rates < 6%. When comparing AR to direct vision, we found that scores were significatively higher in AR for all target structures. AR aided both experienced surgeons and trainees, whether it was for TLN, ureter, or vessel identification. Conclusion This computer-assisted system was reliable, safe, and accurate, and the present achievements represent a first step toward a clinical study. Graphical abstract
- Open Access
- 9 September 2021
- Published by BMJ
- Vol. 70 (Suppl 1) , A112-A113
214 Virtual reality hypnosis on cold pain perception in healthy volunteers
Background and Aims Over 200 millions of surgeries are performed each year, these may lead to postoperative pain mainly managed with opioid prescription [1]. It is recommended to decrease the use of opioids by adding at least one non-pharmacological pain management modality in the treatment [2]. Virtual Reality and hypnosis are examples of such. The aim of this study was to measure the pain intensity and unpleasantness perception at rest and during virtual reality hypnosis (VRH) in healthy volunteers. Methods With Ethics Committee agreement (CPP-ILE-DE-FRANCE III, approval date 04/02/2020), healthy volunteers were prospectively included to receive nociceptive cold stimulations at rest, without VRH (Control condition) and during VRH with HypnoVR*software (Oculus Rift® headset, Oculus VR) (VRH condition). Three intensities (Visual Analog Scale (VAS) = 0/10, 2/10, 4/10) of cold stimulations were applied 3 times each (stimulation duration: 20 seconds, separated by 1 minute) on participant’s wrist with a thermode. Intensities were chosen beforehand by applying various cold intensities that subjects scored on a VAS. Maximal pain intensity and unpleasantness perception were collected after the end of each condition and then compared. Results A total of 41 healthy volunteers were analyzed (demographic data: table 1). There is a significant decrease in pain average intensity and unpleasantness perception in VRH compared to control group (2,46±1,59 vs 3,66±1,84; p<.0001 and 3,06±2,06 vs 2,21±1,70; pConclusions VRH (HypnoVR*) managed to decrease cold pain intensity (-33%) and unpleasantness (-40%) perception in healthy volunteers. These results need to be confirmed in clinical setting.
- 9 September 2021
- Published by BMJ
- Vol. 70 (Suppl 1) , A112-A113
Open Access214 Virtual reality hypnosis on cold pain perception in healthy volunteers
Background and Aims Over 200 millions of surgeries are performed each year, these may lead to postoperative pain mainly managed with opioid prescription [1]. It is recommended to decrease the use of opioids by adding at least one non-pharmacological pain management modality in the treatment [2]. Virtual Reality and hypnosis are examples of such. The aim of this study was to measure the pain intensity and unpleasantness perception at rest and during virtual reality hypnosis (VRH) in healthy volunteers. Methods With Ethics Committee agreement (CPP-ILE-DE-FRANCE III, approval date 04/02/2020), healthy volunteers were prospectively included to receive nociceptive cold stimulations at rest, without VRH (Control condition) and during VRH with HypnoVR*software (Oculus Rift® headset, Oculus VR) (VRH condition). Three intensities (Visual Analog Scale (VAS) = 0/10, 2/10, 4/10) of cold stimulations were applied 3 times each (stimulation duration: 20 seconds, separated by 1 minute) on participant’s wrist with a thermode. Intensities were chosen beforehand by applying various cold intensities that subjects scored on a VAS. Maximal pain intensity and unpleasantness perception were collected after the end of each condition and then compared. Results A total of 41 healthy volunteers were analyzed (demographic data: table 1). There is a significant decrease in pain average intensity and unpleasantness perception in VRH compared to control group (2,46±1,59 vs 3,66±1,84; p<.0001 and 3,06±2,06 vs 2,21±1,70; pConclusions VRH (HypnoVR*) managed to decrease cold pain intensity (-33%) and unpleasantness (-40%) perception in healthy volunteers. These results need to be confirmed in clinical setting.
- 27 April 2020
- Published by Springer Nature in Surgical Endoscopy
- Vol. 35 (4) , 1844-1850
Hyperspectral enhanced reality (HYPER) for anatomical liver resection
Background Clinical evaluation of the demarcation line separating ischemic from non-ischemic liver parenchyma may be challenging. Hyperspectral imaging (HSI) is a noninvasive imaging modality, which combines a camera with a spectroscope and allows quantitative imaging of tissue oxygenation. Our group developed a software to overlay HSI images onto the operative field, obtaining HSI-based enhanced reality (HYPER). The aim of the present study was to evaluate the accuracy of HYPER to identify the demarcation line after a left vascular inflow occlusion during an anatomical left hepatectomy. Materials and methods In the porcine model (n = 3), the left branches of the hepatic pedicle were ligated. Before and after vascular occlusion, HSI images based on tissue oxygenation (StO2), obtained through the Near-Infrared index (NIR index), were regularly acquired and superimposed onto RGB video. The demarcation line was marked on the liver surface with electrocautery according to HYPER. Local lactates were measured on blood samples from the liver surface in both ischemic and perfused segments using a strip-based device. At the same areas, confocal endomicroscopy was performed. Results After ligation, HSI demonstrated a significantly lower oxygenation (NIR index) in the left medial lobe (LML) (0.27% ± 0.21) when compared to the right medial lobe (RML) (58.60% ± 12.08; p = 0.0015). Capillary lactates were significantly higher (3.07 mmol/L ± 0.84 vs. 1.33 ± 0.71 mmol/L; p = 0.0356) in the LML versus RML, respectively. Concordantly, confocal videos demonstrated the absence of blood flow in the LML and normal perfusion in the RML. Conclusions HYPER has made it possible to correctly identify the demarcation line and quantify surface liver oxygenation. HYPER could be an intraoperative tool to guide perfusion-based demarcation line assessment and segmentation.
- 27 April 2020
- Published by Springer Nature in Surgical Endoscopy
- Vol. 35 (4) , 1844-1850
Hyperspectral enhanced reality (HYPER) for anatomical liver resection
Background Clinical evaluation of the demarcation line separating ischemic from non-ischemic liver parenchyma may be challenging. Hyperspectral imaging (HSI) is a noninvasive imaging modality, which combines a camera with a spectroscope and allows quantitative imaging of tissue oxygenation. Our group developed a software to overlay HSI images onto the operative field, obtaining HSI-based enhanced reality (HYPER). The aim of the present study was to evaluate the accuracy of HYPER to identify the demarcation line after a left vascular inflow occlusion during an anatomical left hepatectomy. Materials and methods In the porcine model (n = 3), the left branches of the hepatic pedicle were ligated. Before and after vascular occlusion, HSI images based on tissue oxygenation (StO2), obtained through the Near-Infrared index (NIR index), were regularly acquired and superimposed onto RGB video. The demarcation line was marked on the liver surface with electrocautery according to HYPER. Local lactates were measured on blood samples from the liver surface in both ischemic and perfused segments using a strip-based device. At the same areas, confocal endomicroscopy was performed. Results After ligation, HSI demonstrated a significantly lower oxygenation (NIR index) in the left medial lobe (LML) (0.27% ± 0.21) when compared to the right medial lobe (RML) (58.60% ± 12.08; p = 0.0015). Capillary lactates were significantly higher (3.07 mmol/L ± 0.84 vs. 1.33 ± 0.71 mmol/L; p = 0.0356) in the LML versus RML, respectively. Concordantly, confocal videos demonstrated the absence of blood flow in the LML and normal perfusion in the RML. Conclusions HYPER has made it possible to correctly identify the demarcation line and quantify surface liver oxygenation. HYPER could be an intraoperative tool to guide perfusion-based demarcation line assessment and segmentation.
- 15 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 35 (3) , 697-708
Robotic Insertion of Flexible Needle in Deformable Structures Using Inverse Finite-Element Simulation
This paper introduces a new approach for the control of a robotic system interacting with deformable structures. The method is applied to needle insertion procedures, which are among the least invasive surgical approaches to access deep internal structures with sometimes poor access conditions. Yet, during the insertion both tissues and needles deform resulting in a displacement of targets identified at the planning step and significantly raising the technical difficulty of these approaches. Robotic assistance may offer new possibilities to enforce the accuracy of the needle’s positioning, but the deformation of tissues remains an open problem. In this paper, we propose a numerical approach where finite-element (FE) models are used in a close-control robotic loop. We introduce a complete forward simulation of deformable structures (needle and environment) and constraint-based interaction models allowing for the simulation of needle insertion and complex nonlinear phenomena (friction, puncture, and insertion) at a high frequency. For the control, we numerically derive the so-called Jacobian of the Simulation using an inverse method. The most original aspect of this paper lies in the fact that inverse steps are performed in constraints space, allowing this way for fast estimation of the Jacobian (i.e., between 40 and 100 Hz). The method is validated both numerically and experimentally using a flexible needle inserted inside a deformable foam. We show that the robot is able to follow a given trajectory, defined during the planning step, taking into account any occurring deformation of both the needle and the foam during the insertion; without any need for tracking the needle neither the target nor the trajectory.
- 15 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 35 (3) , 697-708
Robotic Insertion of Flexible Needle in Deformable Structures Using Inverse Finite-Element Simulation
This paper introduces a new approach for the control of a robotic system interacting with deformable structures. The method is applied to needle insertion procedures, which are among the least invasive surgical approaches to access deep internal structures with sometimes poor access conditions. Yet, during the insertion both tissues and needles deform resulting in a displacement of targets identified at the planning step and significantly raising the technical difficulty of these approaches. Robotic assistance may offer new possibilities to enforce the accuracy of the needle’s positioning, but the deformation of tissues remains an open problem. In this paper, we propose a numerical approach where finite-element (FE) models are used in a close-control robotic loop. We introduce a complete forward simulation of deformable structures (needle and environment) and constraint-based interaction models allowing for the simulation of needle insertion and complex nonlinear phenomena (friction, puncture, and insertion) at a high frequency. For the control, we numerically derive the so-called Jacobian of the Simulation using an inverse method. The most original aspect of this paper lies in the fact that inverse steps are performed in constraints space, allowing this way for fast estimation of the Jacobian (i.e., between 40 and 100 Hz). The method is validated both numerically and experimentally using a flexible needle inserted inside a deformable foam. We show that the robot is able to follow a given trajectory, defined during the planning step, taking into account any occurring deformation of both the needle and the foam during the insertion; without any need for tracking the needle neither the target nor the trajectory.
- Open Access
- 9 September 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (9) , e106675
Design and Development of a Robotized System Coupled to µCT Imaging for Intratumoral Drug Evaluation in a HCC Mouse Model
Hepatocellular carcinoma (HCC) is one of the most common cancer related deaths worldwide. One of the main challenges in cancer treatment is drug delivery to target cancer cells specifically. Preclinical evaluation of intratumoral drugs in orthotopic liver cancer mouse models is difficult, as percutaneous injection hardly can be precisely performed manually. In the present study we have characterized a hepatoma model developing a single tumor nodule by implantation of Hep55.1C cells in the liver of syngeneic C57BL/6J mice. Tumor evolution was followed up by µCT imaging, and at the histological and molecular levels. This orthotopic, poorly differentiated mouse HCC model expressing fibrosis, inflammation and cancer markers was used to assess the efficacy of drugs. We took advantage of the high precision of a previously developed robotized system for automated, image-guided intratumoral needle insertion, to administer every week in the tumor of the Hep55.1C mouse model. A significant tumor growth inhibition was observed using our robotized system, whereas manual intraperitoneal administration had no effect, by comparison to untreated control mice.
- 9 September 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (9) , e106675
Open AccessDesign and Development of a Robotized System Coupled to µCT Imaging for Intratumoral Drug Evaluation in a HCC Mouse Model
Hepatocellular carcinoma (HCC) is one of the most common cancer related deaths worldwide. One of the main challenges in cancer treatment is drug delivery to target cancer cells specifically. Preclinical evaluation of intratumoral drugs in orthotopic liver cancer mouse models is difficult, as percutaneous injection hardly can be precisely performed manually. In the present study we have characterized a hepatoma model developing a single tumor nodule by implantation of Hep55.1C cells in the liver of syngeneic C57BL/6J mice. Tumor evolution was followed up by µCT imaging, and at the histological and molecular levels. This orthotopic, poorly differentiated mouse HCC model expressing fibrosis, inflammation and cancer markers was used to assess the efficacy of drugs. We took advantage of the high precision of a previously developed robotized system for automated, image-guided intratumoral needle insertion, to administer every week in the tumor of the Hep55.1C mouse model. A significant tumor growth inhibition was observed using our robotized system, whereas manual intraperitoneal administration had no effect, by comparison to untreated control mice.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2013 (1094687X) , 5352-5355
A custom robot for Transcranial Magnetic Stimulation: First assessment on healthy subjects
In this paper, a custom robotic system for Transcranial Magnetic Stimulation is assessed in clinical conditions on healthy subjects. A motor cortex mapping is performed using the robotic system with comparison to a manual approach using a neuronavigation system. Stimulation accuracy, repeatability are evaluated as well as the feeling of the system operator and the subject in terms of comfort, tiredness, stress level, ease-of-use. Very encouraging results are obtained on all these aspects, which strengthens the idea of developing robotic assistance for TMS.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2013 (1094687X) , 5352-5355
A custom robot for Transcranial Magnetic Stimulation: First assessment on healthy subjects
In this paper, a custom robotic system for Transcranial Magnetic Stimulation is assessed in clinical conditions on healthy subjects. A motor cortex mapping is performed using the robotic system with comparison to a manual approach using a neuronavigation system. Stimulation accuracy, repeatability are evaluated as well as the feeling of the system operator and the subject in terms of comfort, tiredness, stress level, ease-of-use. Very encouraging results are obtained on all these aspects, which strengthens the idea of developing robotic assistance for TMS.
- 7 March 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (8) , 2193-2204
Design and In Vivo Evaluation of a Robotized Needle Insertion System for Small Animals
The development of imaging devices adapted to small animals has opened the way to image-guided procedures in biomedical research. In this paper, we focus on automated procedures to study the effects of the recurrent administration of substances to the same animal over time. A dedicated system and the associated workflow have been designed to percutaneously position a needle into the abdominal organs of mice. Every step of the procedure has been automated: the camera calibration, the needle access planning, the robotized needle positioning, and the respiratory-gated needle insertion. Specific devices have been developed for the registration, the animal binding under anesthesia, and the skin puncture. Among the presented results, the system accuracy is particularly emphasized, both in vitro using gelose phantoms and in vivo by injecting substances into various abdominal organs. The study shows that robotic assistance could be routinely used in biomedical research laboratories to improve existing procedures, allowing automated accurate treatments and limited animal sacrifices.
- 7 March 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (8) , 2193-2204
Design and In Vivo Evaluation of a Robotized Needle Insertion System for Small Animals
The development of imaging devices adapted to small animals has opened the way to image-guided procedures in biomedical research. In this paper, we focus on automated procedures to study the effects of the recurrent administration of substances to the same animal over time. A dedicated system and the associated workflow have been designed to percutaneously position a needle into the abdominal organs of mice. Every step of the procedure has been automated: the camera calibration, the needle access planning, the robotized needle positioning, and the respiratory-gated needle insertion. Specific devices have been developed for the registration, the animal binding under anesthesia, and the skin puncture. Among the presented results, the system accuracy is particularly emphasized, both in vitro using gelose phantoms and in vivo by injecting substances into various abdominal organs. The study shows that robotic assistance could be routinely used in biomedical research laboratories to improve existing procedures, allowing automated accurate treatments and limited animal sacrifices.
- 1 January 2013
- Vol. 184, 117-21
Using simulation to design control strategies for robotic no-scar surgery.
No-scar surgery, which aims at performing surgical operations without visible scars, is the vanguard in the field of Minimally Invasive Surgery. No-scar surgery can be performed with flexible instruments, carried by a guide under the vision of an endoscopic camera. This technique brings many benefits for the patient, but also introduces several difficulties for the surgeon. We aim at developing a teleoperated robotic system for assisting surgeons in this kind of operations. In this paper, we present a virtual simulator of the system that allows to assess different control strategies for our robot and to study possible mechanical issues.
- 1 January 2013
- Vol. 184, 117-21
Using simulation to design control strategies for robotic no-scar surgery.
No-scar surgery, which aims at performing surgical operations without visible scars, is the vanguard in the field of Minimally Invasive Surgery. No-scar surgery can be performed with flexible instruments, carried by a guide under the vision of an endoscopic camera. This technique brings many benefits for the patient, but also introduces several difficulties for the surgeon. We aim at developing a teleoperated robotic system for assisting surgeons in this kind of operations. In this paper, we present a virtual simulator of the system that allows to assess different control strategies for our robot and to study possible mechanical issues.
- 1 January 2013
- Published by Springer Nature
- p. 90-104
A Simulator for Designing Control Schemes for a Teleoperated Flexible Robotic System
- 1 January 2013
- Published by Springer Nature
- p. 90-104
A Simulator for Designing Control Schemes for a Teleoperated Flexible Robotic System