Yoshinari Endo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yoshinari Endo has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Toshihiro Shirai
Department of Respiratory Medicine Shizuoka General Hospital Shizuoka Japan
4 shared publications - Keita Hirai
Department of Pharmacy Shinshu University Hospital Matsumoto Nagano Japan
3 shared publications - Akito Yamamoto
Department of Respiratory Medicine, Shizuoka General Hospital, Shizuoka, Japan
2 shared publications Kazuhiro Asada
Department of Respiratory Medicine, Shizuoka General Hospital, Shizuoka, Japan
2 shared publicationsTaisuke Akamatsu
Department of Respiratory Medicine, Shizuoka General Hospital, Shizuoka, Japan
2 shared publications- Takahito Suzuki
Second Division, Department of Internal Medicine, Hamamatsu University School of Medicine, Hamamatsu, Japan
2 shared publications
Latest Publications
- 1 November 2020
- Published by Taylor & Francis in COPD: Journal of Chronic Obstructive Pulmonary Disease
- Vol. 17 (6) , 647-654
Oscillometry as a Predictor of Exercise Tolerance in COPD
The usefulness of the oscillometry, known as forced oscillation technique, for predicting exercise tolerance in subjects with COPD is unknown. To test the hypothesis, we investigated whether oscillometry could predict a 6-minute walking distance (6MWD) = 350 m or 6MWD = 350 m, and 14 (24.6%) had a 6MWD <350 m. Between the two groups, there were significant differences in mMRC scale, GOLD stages, CAT scores, FEV1, IC, 6MWD, lowest SpO(2), maximum Borg scale, respiratory resistance (Rrs), and reactance (Xrs). In multivariate regression analysis, a 6MWD <350 m was independently predicted by CAT scores (OR 1.15, 95% CI: 1.01-1.30) and inspiratory R5 (OR 6.01, 95% CI: 1.09-33.30). In receiver operating characteristic curves, the area under the curve was 0.76, 0.78, and 0.85 for CAT scores, R5, and CAT scores + R5, respectively, with the best cutoff value of 17 and 2.82 cmH(2)0/L/s. In conclusion, the oscillatory parameter, inspiratory R5, predicted low exercise tolerance in COPD subjects.
- 1 November 2020
- Published by Taylor & Francis in COPD: Journal of Chronic Obstructive Pulmonary Disease
- Vol. 17 (6) , 647-654
Oscillometry as a Predictor of Exercise Tolerance in COPD
The usefulness of the oscillometry, known as forced oscillation technique, for predicting exercise tolerance in subjects with COPD is unknown. To test the hypothesis, we investigated whether oscillometry could predict a 6-minute walking distance (6MWD) = 350 m or 6MWD = 350 m, and 14 (24.6%) had a 6MWD <350 m. Between the two groups, there were significant differences in mMRC scale, GOLD stages, CAT scores, FEV1, IC, 6MWD, lowest SpO(2), maximum Borg scale, respiratory resistance (Rrs), and reactance (Xrs). In multivariate regression analysis, a 6MWD <350 m was independently predicted by CAT scores (OR 1.15, 95% CI: 1.01-1.30) and inspiratory R5 (OR 6.01, 95% CI: 1.09-33.30). In receiver operating characteristic curves, the area under the curve was 0.76, 0.78, and 0.85 for CAT scores, R5, and CAT scores + R5, respectively, with the best cutoff value of 17 and 2.82 cmH(2)0/L/s. In conclusion, the oscillatory parameter, inspiratory R5, predicted low exercise tolerance in COPD subjects.
- 6 February 2019
- Published by Elsevier in Respiratory Investigation
- Vol. 57 (3) , 252-259
Improved cough- and sputum-related quality of life after initiation of treatment in pulmonary tuberculosis
- 6 February 2019
- Published by Elsevier in Respiratory Investigation
- Vol. 57 (3) , 252-259
Improved cough- and sputum-related quality of life after initiation of treatment in pulmonary tuberculosis
- 1 September 2016
- Published by European Respiratory Society (ERS)
- Vol. 48 (suppl 60) , PA569
Forced oscillation technique as a predictor of airway hyper-responsiveness in asthma
Introduction: Airway hyper-responsiveness (AHR) is a cardinal feature of asthma. In a continuous methacholine challenge test (MCT) using Astograph (Chest, Tokyo, Japan), AHR is measured by the methacholine respiratory system resistance dose-response curve. However, information regarding the relationship between AHR and the broadband frequency forced oscillation technique (FOT) is limited. Aims and objective: To investigate the relationship between AHR and the FOT parameters. Methods: Subjects included 37 patients with asthma. AHR and FOT parameters were measured with Astograph and MostGraph (Chest, Tokyo, Japan), respectively. FOT, spirometry, and fractional exhaled nitric oxide (FeNO) were performed before MCT. We used the value of the cumulative dose of inhaled methacholine measured at the inflection point at which respiratory conductance starts to decrease (Dmin) as an index of AHR. This variable was measured in terms of a unit defined as a 1-minute inhalation of methacholine (1 mg/ml). We defined Dmin less than 10 units as AHR. Results: Dmin correlated with inspiratory respiratory system resistance at 5 Hz (R5), 20 Hz (R20), low-frequency area (ALX) and FeNO before MCT (r=-0.495, -0.489, -0.367 and -0.383, respectively). An ROC curve analysis to identify AHR revealed that the area under the curve of R5 (0.741) was larger than those of other parameters. Conclusions: R5, a forced oscillatory parameter, before MCT predicts AHR. ![Figure][1] [1]: pending:yes
- 1 September 2016
- Published by European Respiratory Society (ERS)
- Vol. 48 (suppl 60) , PA569
Forced oscillation technique as a predictor of airway hyper-responsiveness in asthma
Introduction: Airway hyper-responsiveness (AHR) is a cardinal feature of asthma. In a continuous methacholine challenge test (MCT) using Astograph (Chest, Tokyo, Japan), AHR is measured by the methacholine respiratory system resistance dose-response curve. However, information regarding the relationship between AHR and the broadband frequency forced oscillation technique (FOT) is limited. Aims and objective: To investigate the relationship between AHR and the FOT parameters. Methods: Subjects included 37 patients with asthma. AHR and FOT parameters were measured with Astograph and MostGraph (Chest, Tokyo, Japan), respectively. FOT, spirometry, and fractional exhaled nitric oxide (FeNO) were performed before MCT. We used the value of the cumulative dose of inhaled methacholine measured at the inflection point at which respiratory conductance starts to decrease (Dmin) as an index of AHR. This variable was measured in terms of a unit defined as a 1-minute inhalation of methacholine (1 mg/ml). We defined Dmin less than 10 units as AHR. Results: Dmin correlated with inspiratory respiratory system resistance at 5 Hz (R5), 20 Hz (R20), low-frequency area (ALX) and FeNO before MCT (r=-0.495, -0.489, -0.367 and -0.383, respectively). An ROC curve analysis to identify AHR revealed that the area under the curve of R5 (0.741) was larger than those of other parameters. Conclusions: R5, a forced oscillatory parameter, before MCT predicts AHR. ![Figure][1] [1]: pending:yes