Estefania De Garate
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Estefania De Garate has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
- Chiara Bucciarelli-Ducci
Royal Brompton and Harefield Hospitals, Guys and St Thomas NHS Foundation Trust , London SW3 6NP
15 shared publications - Amardeep Ghosh Dastidar
NIHR Bristol Cardiovascular Biomedical Research Unit, Cardiac Magnetic Resonance Department, Bristol Heart Institute, University Hospitals Bristol NHS Foundation Trust, Bristol, UK
8 shared publications Anna Baritussio
Bristol Heart Institute, University Hospitals Bristol and Weston NHS Trust, Bristol, United Kingdom
8 shared publications- Giovanni Biglino
University of Bristol
7 shared publications Alessandra Scatteia
Bristol Heart Institute, University Hospitals Bristol and Weston NHS Trust, Bristol, United Kingdom
6 shared publicationsPriyanka Singhal
Bristol Heart Institute, University Hospitals Bristol NHS Foundation Trust, Bristol, United Kingdom; School of Clinical Sciences, Faculty of Health Sciences, University of Bristol, Bristol, United Kingdom
4 shared publications
Latest Publications
- Open Access
- 31 May 2023
- Published by MDPI AG in Bioengineering
- Vol. 10  (6) , 662
Feasibility of Wave Intensity Analysis from 4D Cardiovascular Magnetic Resonance Imaging Data
Congenital heart defects (CHD) introduce haemodynamic changes; e.g., bicuspid aortic valve (BAV) presents a turbulent helical flow, which activates aortic pathological processes. Flow quantification is crucial for diagnostics and to plan corrective strategies. Multiple imaging modalities exist, with phase contrast magnetic resonance imaging (PC-MRI) being the current gold standard; however, multiple predetermined site measurements may be required, while 4D MRI allows for measurements of area (A) and velocity (U) in all spatial dimensions, acquiring a single volume and enabling a retrospective analysis at multiple locations. We assessed the feasibility of gathering hemodynamic insight into aortic hemodynamics by means of wave intensity analysis (WIA) derived from 4D MRI. Data were collected in n = 12 BAV patients and n = 7 healthy controls. Following data acquisition, WIA was successfully derived at three planes (ascending, thoracic and descending aorta) in all cases. The values of wave speed were physiological and, while the small sample limited any clinical interpretation of the results, the study shows the possibility of studying wave travel and wave reflection based on 4D MRI. Below, we demonstrate for the first time the feasibility of deriving wave intensity analysis from 4D flow data and open the door to research applications in different cardiovascular scenarios.
- 31 May 2023
- Published by MDPI AG in Bioengineering
- Vol. 10  (6) , 662
Open AccessFeasibility of Wave Intensity Analysis from 4D Cardiovascular Magnetic Resonance Imaging Data
Congenital heart defects (CHD) introduce haemodynamic changes; e.g., bicuspid aortic valve (BAV) presents a turbulent helical flow, which activates aortic pathological processes. Flow quantification is crucial for diagnostics and to plan corrective strategies. Multiple imaging modalities exist, with phase contrast magnetic resonance imaging (PC-MRI) being the current gold standard; however, multiple predetermined site measurements may be required, while 4D MRI allows for measurements of area (A) and velocity (U) in all spatial dimensions, acquiring a single volume and enabling a retrospective analysis at multiple locations. We assessed the feasibility of gathering hemodynamic insight into aortic hemodynamics by means of wave intensity analysis (WIA) derived from 4D MRI. Data were collected in n = 12 BAV patients and n = 7 healthy controls. Following data acquisition, WIA was successfully derived at three planes (ascending, thoracic and descending aorta) in all cases. The values of wave speed were physiological and, while the small sample limited any clinical interpretation of the results, the study shows the possibility of studying wave travel and wave reflection based on 4D MRI. Below, we demonstrate for the first time the feasibility of deriving wave intensity analysis from 4D flow data and open the door to research applications in different cardiovascular scenarios.
- Open Access
- 10 May 2023
- Published by F1000 Research Ltd in Wellcome Open Research
- Vol. 6, 253
Mitral regurgitation quantification by cardiac magnetic resonance imaging (MRI) remains reproducible between software solutions
Background: The reproducibility of mitral regurgitation (MR) quantification by cardiovascular magnetic resonance (CMR) imaging using different software solutions remains unclear. This research aimed to investigate the reproducibility of MR quantification between two software solutions: MASS (version 2019 EXP, LUMC, Netherlands) and CAAS (version 5.2, Pie Medical Imaging). Methods: CMR data of 35 patients with MR (12 primary MR, 13 mitral valve repair/replacement, and ten secondary MR) was used. Four methods of MR volume quantification were studied, including two 4D-flow CMR methods (MRMVAV and MRJet) and two non-4D-flow techniques (MRStandard and MRLVRV). We conducted within-software and inter-software correlation and agreement analyses. Results: All methods demonstrated significant correlation between the two software solutions: MRStandard (r=0.92, p<0.001), MRLVRV (r=0.95, p<0.001), MRJet (r=0.86, p<0.001), and MRMVAV (r=0.91, p<0.001). Between CAAS and MASS, MRJet and MRMVAV, compared to each of the four methods, were the only methods not to be associated with significant bias. Conclusions: We conclude that 4D-flow CMR methods demonstrate equivalent reproducibility to non-4D-flow methods but greater levels of agreement between software solutions.
- 10 May 2023
- Published by F1000 Research Ltd in Wellcome Open Research
- Vol. 6, 253
Open AccessMitral regurgitation quantification by cardiac magnetic resonance imaging (MRI) remains reproducible between software solutions
Background: The reproducibility of mitral regurgitation (MR) quantification by cardiovascular magnetic resonance (CMR) imaging using different software solutions remains unclear. This research aimed to investigate the reproducibility of MR quantification between two software solutions: MASS (version 2019 EXP, LUMC, Netherlands) and CAAS (version 5.2, Pie Medical Imaging). Methods: CMR data of 35 patients with MR (12 primary MR, 13 mitral valve repair/replacement, and ten secondary MR) was used. Four methods of MR volume quantification were studied, including two 4D-flow CMR methods (MRMVAV and MRJet) and two non-4D-flow techniques (MRStandard and MRLVRV). We conducted within-software and inter-software correlation and agreement analyses. Results: All methods demonstrated significant correlation between the two software solutions: MRStandard (r=0.92, p<0.001), MRLVRV (r=0.95, p<0.001), MRJet (r=0.86, p<0.001), and MRMVAV (r=0.91, p<0.001). Between CAAS and MASS, MRJet and MRMVAV, compared to each of the four methods, were the only methods not to be associated with significant bias. Conclusions: We conclude that 4D-flow CMR methods demonstrate equivalent reproducibility to non-4D-flow methods but greater levels of agreement between software solutions.
- Open Access
A Segmental Approach from Molecular Profiling to Medical Imaging to Study Bicuspid Aortic Valve Aortopathy
Bicuspid aortic valve (BAV) patients develop ascending aortic (AAo) dilation. The pathogenesis of BAV aortopathy (genetic vs. haemodynamic) remains unclear. This study aims to identify regional changes around the AAo wall in BAV patients with aortopathy, integrating molecular data and clinical imaging. BAV patients with aortopathy (n = 15) were prospectively recruited to surgically collect aortic tissue and measure molecular markers across the AAo circumference. Dilated (anterior/right) vs. non-dilated (posterior/left) circumferential segments were profiled for whole-genomic microRNAs (next-generation RNA sequencing, miRCURY LNA PCR), protein content (tandem mass spectrometry), and elastin fragmentation and degeneration (histomorphometric analysis). Integrated bioinformatic analyses of RNA sequencing and proteomic datasets identified five microRNAs (miR-128-3p, miR-210-3p, miR-150-5p, miR-199b-5p, and miR-21-5p) differentially expressed across the AAo circumference. Among them, three miRNAs (miR-128-3p, miR-150-5p, and miR-199b-5p) were predicted to have an effect on eight common target genes, whose expression was dysregulated, according to proteomic analyses, and involved in the vascular-endothelial growth-factor signalling, Hippo signalling, and arachidonic acid pathways. Decreased elastic fibre levels and elastic layer thickness were observed in the dilated segments. Additionally, in a subset of patients n = 6/15, a four-dimensional cardiac magnetic resonance (CMR) scan was performed. Interestingly, an increase in wall shear stress (WSS) was observed at the anterior/right wall segments, concomitantly with the differentially expressed miRNAs and decreased elastic fibres. This study identified new miRNAs involved in the BAV aortic wall and revealed the concomitant expressional dysregulation of miRNAs, proteins, and elastic fibres on the anterior/right wall in dilated BAV patients, corresponding to regions of elevated WSS.
Open AccessA Segmental Approach from Molecular Profiling to Medical Imaging to Study Bicuspid Aortic Valve Aortopathy
Bicuspid aortic valve (BAV) patients develop ascending aortic (AAo) dilation. The pathogenesis of BAV aortopathy (genetic vs. haemodynamic) remains unclear. This study aims to identify regional changes around the AAo wall in BAV patients with aortopathy, integrating molecular data and clinical imaging. BAV patients with aortopathy (n = 15) were prospectively recruited to surgically collect aortic tissue and measure molecular markers across the AAo circumference. Dilated (anterior/right) vs. non-dilated (posterior/left) circumferential segments were profiled for whole-genomic microRNAs (next-generation RNA sequencing, miRCURY LNA PCR), protein content (tandem mass spectrometry), and elastin fragmentation and degeneration (histomorphometric analysis). Integrated bioinformatic analyses of RNA sequencing and proteomic datasets identified five microRNAs (miR-128-3p, miR-210-3p, miR-150-5p, miR-199b-5p, and miR-21-5p) differentially expressed across the AAo circumference. Among them, three miRNAs (miR-128-3p, miR-150-5p, and miR-199b-5p) were predicted to have an effect on eight common target genes, whose expression was dysregulated, according to proteomic analyses, and involved in the vascular-endothelial growth-factor signalling, Hippo signalling, and arachidonic acid pathways. Decreased elastic fibre levels and elastic layer thickness were observed in the dilated segments. Additionally, in a subset of patients n = 6/15, a four-dimensional cardiac magnetic resonance (CMR) scan was performed. Interestingly, an increase in wall shear stress (WSS) was observed at the anterior/right wall segments, concomitantly with the differentially expressed miRNAs and decreased elastic fibres. This study identified new miRNAs involved in the BAV aortic wall and revealed the concomitant expressional dysregulation of miRNAs, proteins, and elastic fibres on the anterior/right wall in dilated BAV patients, corresponding to regions of elevated WSS.
- Open Access
- 1 October 2022
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 43  (Supplement)
Molecular and haemodynamic interplay in bicuspid aortic valve aortopathy: segmental differences across the aortic circumference
Background: Bicuspid aortic valve (BAV) patients develop ascending aortic (AAo) dilation. The pathogenesis of BAV-aortopathy (genetic vs. hemodynamic) remains unclear. Purpose: To identify regional changes around the AAo wall in BAV patients with aortopathy integrating clinical imaging and molecular data. Methods: BAV patients with aortopathy (n=20) were recruited prospectively to surgically collect aortic tissue and perform four-dimensional cardiac magnetic resonance (CMR) scans. Molecular markers were measured analysing the tissue biopsies (n=15) and wall shear stress (WSS) across the AAo circumference was calculated from the 4D CMR data (n=11 patients, and n=7 additional healthy volunteers for comparison). Dilated (anterior/right) vs. non-dilated (posterior/left) circumferential segments were profiled for whole genomic microRNAs (Next Generation RNA-Sequencing, miRCURY LNA PCR), proteins content (Tandem Mass Spectrometry) and elastin fragmentation and degeneration (histomorphometric analysis). Picture 1 summarises the study approach (including a map of the AAo divided in the following segments: A=anterior, AR=anterior-right, PR=posterior-right, P=posterior, PL=posterior-left, AL=anterior-left). Results: Integrated bioinformatic analyses of RNA-sequencing and proteomic datasets identified 5 microRNAs (miR-128-3p, miR-210-3p, miR-150-5p, miR-199b-5p, and miR-21-5p) differentially expressed across the AAo circumference. Among them, three miRNAs (miR-128-3p, miR-150-5p, and miR-199b-5p) were predicted to have an effect on eight common target genes, whose expression was dysregulated according to proteomic analyses and involved in vascular endothelial growth factor signalling, hippo signaling and arachidonic acid pathway. Decreased elastic fibre levels and elastic layer thickness were observed in the dilated segments in the histomorphometric analysis. Increased WSS and flow-velocity, helical streamlines and asymmetrical flow were observed at the anterior/right wall in asymmetrically and symmetrically dilated patients (the latter exhibiting higher WSS), compared to healthy volunteers. Conclusion: This study has newly revealed concomitant expressional dysregulation of miRNAs, proteins, and elastic fibres on the anterior/right wall in dilated BAV patients, corresponding to regions of elevated WSS, contributing to advance the understanding of the interplay of genetic and hemodynamic factors underpinning BAV aortopathy. Funding Acknowledgement: Type of funding sources: Foundation. Main funding source(s): British Heart Foundation and Above & Beyond
- 1 October 2022
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 43  (Supplement)
Open AccessMolecular and haemodynamic interplay in bicuspid aortic valve aortopathy: segmental differences across the aortic circumference
Background: Bicuspid aortic valve (BAV) patients develop ascending aortic (AAo) dilation. The pathogenesis of BAV-aortopathy (genetic vs. hemodynamic) remains unclear. Purpose: To identify regional changes around the AAo wall in BAV patients with aortopathy integrating clinical imaging and molecular data. Methods: BAV patients with aortopathy (n=20) were recruited prospectively to surgically collect aortic tissue and perform four-dimensional cardiac magnetic resonance (CMR) scans. Molecular markers were measured analysing the tissue biopsies (n=15) and wall shear stress (WSS) across the AAo circumference was calculated from the 4D CMR data (n=11 patients, and n=7 additional healthy volunteers for comparison). Dilated (anterior/right) vs. non-dilated (posterior/left) circumferential segments were profiled for whole genomic microRNAs (Next Generation RNA-Sequencing, miRCURY LNA PCR), proteins content (Tandem Mass Spectrometry) and elastin fragmentation and degeneration (histomorphometric analysis). Picture 1 summarises the study approach (including a map of the AAo divided in the following segments: A=anterior, AR=anterior-right, PR=posterior-right, P=posterior, PL=posterior-left, AL=anterior-left). Results: Integrated bioinformatic analyses of RNA-sequencing and proteomic datasets identified 5 microRNAs (miR-128-3p, miR-210-3p, miR-150-5p, miR-199b-5p, and miR-21-5p) differentially expressed across the AAo circumference. Among them, three miRNAs (miR-128-3p, miR-150-5p, and miR-199b-5p) were predicted to have an effect on eight common target genes, whose expression was dysregulated according to proteomic analyses and involved in vascular endothelial growth factor signalling, hippo signaling and arachidonic acid pathway. Decreased elastic fibre levels and elastic layer thickness were observed in the dilated segments in the histomorphometric analysis. Increased WSS and flow-velocity, helical streamlines and asymmetrical flow were observed at the anterior/right wall in asymmetrically and symmetrically dilated patients (the latter exhibiting higher WSS), compared to healthy volunteers. Conclusion: This study has newly revealed concomitant expressional dysregulation of miRNAs, proteins, and elastic fibres on the anterior/right wall in dilated BAV patients, corresponding to regions of elevated WSS, contributing to advance the understanding of the interplay of genetic and hemodynamic factors underpinning BAV aortopathy. Funding Acknowledgement: Type of funding sources: Foundation. Main funding source(s): British Heart Foundation and Above & Beyond
- Open Access
- 13 January 2022
- Published by F1000 Research Ltd in Wellcome Open Research
- Vol. 6, 253
Mitral regurgitation quantification by cardiac magnetic resonance imaging (MRI) remains reproducible between software solutions
Background: The reproducibility of mitral regurgitation (MR) quantification by cardiovascular magnetic resonance (CMR) imaging using different software solutions remains unclear. This research aimed to investigate the reproducibility of MR quantification between two software solutions: MASS (version 2019 EXP, LUMC, Netherlands) and CAAS (version 5.2, Pie Medical Imaging). Methods: CMR data of 35 patients with MR (12 primary MR, 13 mitral valve repair/replacement, and ten secondary MR) was used. Four methods of MR volume quantification were studied, including two 4D-flow CMR methods (MRMVAV and MRJet) and two non-4D-flow techniques (MRStandard and MRLVRV). We conducted within-software and inter-software correlation and agreement analyses. Results: All methods demonstrated significant correlation between the two software solutions: MRStandard (r=0.92, p<0.001), MRLVRV (r=0.95, p<0.001), MRJet (r=0.86, p<0.001), and MRMVAV (r=0.91, p<0.001). Between CAAS and MASS, MRJet and MRMVAV, compared to each of the four methods, were the only methods not to be associated with significant bias. Conclusions: We conclude that 4D-flow CMR methods demonstrate equivalent reproducibility to non-4D-flow methods but greater levels of agreement between software solutions.
- 13 January 2022
- Published by F1000 Research Ltd in Wellcome Open Research
- Vol. 6, 253
Open AccessMitral regurgitation quantification by cardiac magnetic resonance imaging (MRI) remains reproducible between software solutions
Background: The reproducibility of mitral regurgitation (MR) quantification by cardiovascular magnetic resonance (CMR) imaging using different software solutions remains unclear. This research aimed to investigate the reproducibility of MR quantification between two software solutions: MASS (version 2019 EXP, LUMC, Netherlands) and CAAS (version 5.2, Pie Medical Imaging). Methods: CMR data of 35 patients with MR (12 primary MR, 13 mitral valve repair/replacement, and ten secondary MR) was used. Four methods of MR volume quantification were studied, including two 4D-flow CMR methods (MRMVAV and MRJet) and two non-4D-flow techniques (MRStandard and MRLVRV). We conducted within-software and inter-software correlation and agreement analyses. Results: All methods demonstrated significant correlation between the two software solutions: MRStandard (r=0.92, p<0.001), MRLVRV (r=0.95, p<0.001), MRJet (r=0.86, p<0.001), and MRMVAV (r=0.91, p<0.001). Between CAAS and MASS, MRJet and MRMVAV, compared to each of the four methods, were the only methods not to be associated with significant bias. Conclusions: We conclude that 4D-flow CMR methods demonstrate equivalent reproducibility to non-4D-flow methods but greater levels of agreement between software solutions.
- Open Access
- 6 October 2021
- Published by Elsevier in JACC: Case Reports
- Vol. 3  (13) , 1509-1511
Stone Heart
- 6 October 2021
- Published by Elsevier in JACC: Case Reports
- Vol. 3  (13) , 1509-1511
Open AccessStone Heart
- Open Access
- 5 October 2021
- Published by F1000 Research Ltd in Wellcome Open Research
- Vol. 6, 253
Mitral regurgitation quantification by cardiac magnetic resonance imaging (MRI) remains reproducible between software solutions
Background: The reproducibility of mitral regurgitation (MR) quantification by cardiovascular magnetic resonance (CMR) imaging using different software solutions remains unclear. This research aimed to investigate the reproducibility of MR quantification between two software solutions: MASS (version 2019 EXP, LUMC, Netherlands) and CAAS (version 5.2, Pie Medical Imaging). Methods: CMR data of 35 patients with MR (12 primary MR, 13 mitral valve repair/replacement, and ten secondary MR) was used. Four methods of MR volume quantification were studied, including two 4D-flow CMR methods (MRMVAV and MRJet) and two non-4D-flow techniques (MRStandard and MRLVRV). We conducted within-software and inter-software correlation and agreement analyses. Results: All methods demonstrated significant correlation between the two software solutions: MRStandard (r=0.92, p<0.001), MRLVRV (r=0.95, p<0.001), MRJet (r=0.86, p<0.001), and MRMVAV (r=0.91, p<0.001). Between CAAS and MASS, MRJet and MRMVAV, compared to each of the four methods, were the only methods not to be associated with significant bias. Conclusions: We conclude that 4D-flow CMR methods demonstrate equivalent reproducibility to non-4D-flow methods but greater levels of agreement between software solutions.
- 5 October 2021
- Published by F1000 Research Ltd in Wellcome Open Research
- Vol. 6, 253
Open AccessMitral regurgitation quantification by cardiac magnetic resonance imaging (MRI) remains reproducible between software solutions
Background: The reproducibility of mitral regurgitation (MR) quantification by cardiovascular magnetic resonance (CMR) imaging using different software solutions remains unclear. This research aimed to investigate the reproducibility of MR quantification between two software solutions: MASS (version 2019 EXP, LUMC, Netherlands) and CAAS (version 5.2, Pie Medical Imaging). Methods: CMR data of 35 patients with MR (12 primary MR, 13 mitral valve repair/replacement, and ten secondary MR) was used. Four methods of MR volume quantification were studied, including two 4D-flow CMR methods (MRMVAV and MRJet) and two non-4D-flow techniques (MRStandard and MRLVRV). We conducted within-software and inter-software correlation and agreement analyses. Results: All methods demonstrated significant correlation between the two software solutions: MRStandard (r=0.92, p<0.001), MRLVRV (r=0.95, p<0.001), MRJet (r=0.86, p<0.001), and MRMVAV (r=0.91, p<0.001). Between CAAS and MASS, MRJet and MRMVAV, compared to each of the four methods, were the only methods not to be associated with significant bias. Conclusions: We conclude that 4D-flow CMR methods demonstrate equivalent reproducibility to non-4D-flow methods but greater levels of agreement between software solutions.
- Open Access
- 1 October 2019
- Published by Elsevier in International Journal of Cardiology
- Vol. 292, 248-252
Long term cardiovascular magnetic resonance phenotyping of anthracycline cardiomyopathy
- 1 October 2019
- Published by Elsevier in International Journal of Cardiology
- Vol. 292, 248-252
Open AccessLong term cardiovascular magnetic resonance phenotyping of anthracycline cardiomyopathy
- Top Cited Papers
- 1 October 2019
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 12  (10) , 1973-1982
Prognostic Role of CMR and Conventional Risk Factors in Myocardial Infarction With Nonobstructed Coronary Arteries
- 1 October 2019
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 12  (10) , 1973-1982
Top Cited PapersPrognostic Role of CMR and Conventional Risk Factors in Myocardial Infarction With Nonobstructed Coronary Arteries
- 17 June 2019
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 57  (2) , 271-276
Left thoracotomy approach for off-pump coronary artery bypass grafting surgery: 15 years of experience in 2500 consecutive patients
Our goal was to describe the experience at 2 centres with off-pump coronary artery bypass grafting using a left thoracotomy. From January 2002 to December 2017, a total of 2528 consecutive patients (578 women, mean age 62.3 ± 9.1 years) were operated on using this technique. Data were collected prospectively and analysed retrospectively. There were no conversions to median sternotomy and 6 patients (0.2%) were converted to on-pump CABG. The mean number of grafts per patient was 2.8 ± 0. 9. The 30-day mortality rate was 1.0% (25 patients). Most patients were extubated in the operating theatre (97.3%), and 47 patients (1.9%) needed re-exploration for bleeding. Seven patients (0.3%) experienced a cerebrovascular event; 4 (0.3%) had a postoperative myocardial infarction; and 84 (3.4%) had new-onset atrial fibrillation. A total of 1510 patients (61.1%) were discharged from the hospital in the first 48 h after surgery. Long-term survival rates were 98.8%, 93.6% and 69.1% at 1, 5 and 10 years, respectively (central image). During the follow-up period, 60 patients (2.9%) were re-examined for recurrence of angina with a new coronary angiogram; of those, 24 (1.2%) required percutaneous coronary intervention and 11 (0.5%) had redo surgery. A left thoracotomy is a safe alternative to a median sternotomy for coronary artery bypass grafting on the beating heart, with low early complications and good mid- and long-term results.
- 17 June 2019
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 57  (2) , 271-276
Left thoracotomy approach for off-pump coronary artery bypass grafting surgery: 15 years of experience in 2500 consecutive patients
Our goal was to describe the experience at 2 centres with off-pump coronary artery bypass grafting using a left thoracotomy. From January 2002 to December 2017, a total of 2528 consecutive patients (578 women, mean age 62.3 ± 9.1 years) were operated on using this technique. Data were collected prospectively and analysed retrospectively. There were no conversions to median sternotomy and 6 patients (0.2%) were converted to on-pump CABG. The mean number of grafts per patient was 2.8 ± 0. 9. The 30-day mortality rate was 1.0% (25 patients). Most patients were extubated in the operating theatre (97.3%), and 47 patients (1.9%) needed re-exploration for bleeding. Seven patients (0.3%) experienced a cerebrovascular event; 4 (0.3%) had a postoperative myocardial infarction; and 84 (3.4%) had new-onset atrial fibrillation. A total of 1510 patients (61.1%) were discharged from the hospital in the first 48 h after surgery. Long-term survival rates were 98.8%, 93.6% and 69.1% at 1, 5 and 10 years, respectively (central image). During the follow-up period, 60 patients (2.9%) were re-examined for recurrence of angina with a new coronary angiogram; of those, 24 (1.2%) required percutaneous coronary intervention and 11 (0.5%) had redo surgery. A left thoracotomy is a safe alternative to a median sternotomy for coronary artery bypass grafting on the beating heart, with low early complications and good mid- and long-term results.