    Signal Characteristics of Color Doppler Twinkling Across the Ultrasound Processing Chain

    by Abdullah Al Masud, Benjamin Wood, Christine U. Lee, Matthew W. Urban

    The color Doppler twinkling signature is used to detect highly reflective targets with rough surfaces, but its signal characteristics across the ultrasound processing chain remain unclear. This study examines the signal processing of twinkling to identify its discriminators. Polymethyl methacrylate (PMMA), low-twinkling PMMA (LPMMA), and smooth Metal were evaluated using L7-4 and L11-4v transducers with plane-wave (PW) and focused (FOC) transmission at 4–6 MHz. Signals were evaluated at different stages including: beamformed RF, IQ, wall filtering, Power Doppler (PD), and autocorrelation-based spectral features (x₁, x₂). Material-specific differences became clear after wall filtering, with PMMA showing the highest signal and PD magnitudes, LPMMA an intermediate response, and Metal the lowest. Pulse-wise and frame-wise analyses showed different temporal characteristics, with a structured pulse-to-pulse response within each Doppler ensemble and weaker temporal correlation across consecutive frames. Combining spectral and energy information using the joint [x₁, x₂, log₁₀(PD)] feature space improved material separation. Complete PMMA–Metal separation was achieved at 4 MHz, L7-4 PW transmission, whereas higher frequencies substantially increased LPMMA–Metal overlap. The L11-4v showed a different frequency dependence and maintained stronger separation at 5 and 6 MHz. Overall, twinkling was characterized by complementary temporal, spectral, and Doppler-energy features, and material separability depended on the acquisition frequency and transducer.

  • Selection of Breast Biopsy Markers: Effect on Breast Imaging Procedures, Follow-up, and Costs

    by Tanya W. Moseley, Beatriz E. Adrada, Elsa M. Arribas, Matthew W. Urban, Gina Hesley, Gary J. Whitman, Ronald A. Rauch, Mary S. Guirguis, Megha M. Kapoor, Christine U. Lee

    Breast biopsy markers have evolved from simple metallic devices to sophisticated multimaterial tools that have become essential for breast cancer care, demonstrating their clinical benefits in surgical planning, radiation targeting, and cost reduction.


  • Animal Models of Lymphaticovenous Anastomosis: A Systematic Review of Current Evidence and Future Directions in Translational Research

    by Juan I. Isaac, Prabh G. Singh, Christine U. Lee, James T. Paget, Vahe Fahradyan

    Background: Lymphovenous bypass (LVB) or lymphaticovenous anastomosis (LVA) is increasingly applied, including experimental use for Alzheimer's disease via cervical lymphatic pathways. However, literature on long‐term patency and failure mechanisms is scarce, and no gold standard exists for evaluating durability. Robust, reproducible LVA models are essential to advance translational research. This review maps current animal models and proposes strategies for improving reliability and mechanistic insight. Methods: A PRISMA‐guided search of PubMed, Scopus, and Google Scholar identified original animal studies reporting intra‐ or postoperative patency using functional or structural methods. Extracted data included species, anastomosis type, assessment tools, follow‐up intervals, patency rates, and histology. Results: Of 107 records screened, 11 met criteria: rats ( n = 7), rabbits ( n = 1), piglets ( n = 1), and canines ( n = 2). Techniques were mainly end‐to‐end ( n = 9) and end‐to‐side ( n = 2), targeting femoral, iliolumbar, popliteal, mesenteric, cervical, and thoracic‐duct outflows. Intraoperative patency was uniformly high (≥ 90%). Postoperative patency was reported in six studies, ranging from 80% to 100% at ≤ 7 days (ICG lymphography) to 67% at 1 month (canines). Histology (three studies) distinguished patent sites (smooth endothelium) from failed ones (irregular endothelium, thrombus, fibrosis). Follow‐up was categorized as short‐term (0–7 days), mid‐term (2–4 weeks), and long‐term (≥ 1 month), but standardized long‐term outcomes were absent. Conclusions: Future models should integrate noninvasive imaging, serial long‐term follow‐up, and detailed histologic and molecular analysis to clarify success and failure mechanisms. Standardized methodologies will enhance translational relevance, refine surgical techniques, and inform therapies to improve LVA durability.

  • Open Access

    Passive Cavitation Detection Analysis of Materials With Varying Levels of Color Doppler Twinkling

    by Benjamin Wood, Aktharuzzaman, Christine U. Lee, Matthew W. Urban

    The mechanism of color Doppler twinkling has been previously associated with microbubbles through various experiments. As there has been limited work directly showing evidence of bubble oscillation simultaneously with twinkling, passive cavitation detection (PCD) was used to record raw radiofrequency (RF) signals from twinkling objects that could contain microbubble information. Polymethyl methacrylate (PMMA) twinkling markers and non-twinkling samples were evaluated in a PCD setup using a single element passive cavitation detection transducer while varying transmitted peak negative pressures with an L11-4v linear transducer. Recorded PCD data was analyzed in both the time and frequency domains for evidence of bubbles. In the time domain, twinkling markers were found to have more pulse-to-pulse voltage variation than low and non-twinkling samples. In the frequency domain, twinkling markers were found to have higher magnitudes in the inharmonic bands compared to the low and non-twinkling samples. When varying the peak negative pressure of the ultrasound waves from low to high, both the time domain variation and frequency domain inharmonic bands were found to correlate with twinkling (P < 0.016 and P < 0.048, respectively). These results support microbubble oscillation as a cause of twinkling, particularly from the likely presence of unstable cavitation of microbubbles.

  • Open Access

    Multimodality evaluation and ultrasound-guided aspiration of a biopsy-proven inspissated clogged milk duct: a case report

    by Kendal L. Weger, Nicole P. Sandhu, Mohammed Abdelwahed, Christine U. Lee

    Video 1 Fine-needle aspiration of the milk-duct plug. Video 2 Hydrodissection of the milk duct plug. Video 3 Aspiration of the milk duct plug after hydrodissection. Video 4 Immediate post-procedural ultrasound scan. Authors: Kendal L. Weger, Nicole P. Sandhu, Mohammed Abdelwahed, Christine U. Lee

  • Open Access

    Underlying factors that affect ultrasound conspicuity of breast biopsy markers: an exploratory study

    by Jenna Cario, Christine U. Lee, Michael L. Oelze

    Background: During management of node-positive breast cancer, neoadjuvant systemic therapy (NST) is often used to de-escalate surgical intervention. To identify pathology-proven positive nodes regardless of visual changes after NST, breast biopsy clips or markers are inserted under ultrasound guidance as part of standard care, though most markers are used off-label in the axilla. However, clipped nodes may be difficult to visually confirm with ultrasound after a pathological complete response. This can affect the ease of executing subsequent procedures, such as surgical resection, because identifying the marked or clipped nodes in these cases is problematic. The mechanisms that affect these changes in clip conspicuity are poorly understood, making it challenging to improve ultrasound conspicuity of clips in the clinical setting. The aim of this study is to determine which of these mechanisms are inherent to ultrasound as an imaging modality and if they can be accounted for by adjustments to ultrasound scanner settings. Methods: The effect of viewing angle on brightness is assessed in multiple imaging targets, including five commercially-available clips, suspended in gelatin phantoms. Off-gassing from insertion of a dry clip into tissue is assessed as another possible explanation for the observed changes in conspicuity. Results: Brightness was found to vary significantly with viewing angle for some clips. An ex vivo examination of clip conspicuity with time found no changes that would indicate effects such as off-gassing after dry clip insertion. Conclusions: Viewing angle is not affected by any other settings on an ultrasound system besides probe position, suggesting that conspicuity may not be recoverable if repositioning cannot clarify clip location. Even when viewing angle is not a concern in tissue, the presence of other bright scatterers in the field of view can obscure the location of the clip.


  • Open Access

    Breast ultrasound knobology and the knobology of twinkling for marker detection

    by Christine U. Lee, Gina K. Hesley, Taylor A. Pierson, Rebecca L. Higgins, Matthew W. Urban

    Breast ultrasound utilizes various scanning techniques to acquire optimal images for diagnostic evaluation. During interventional procedures, such as ultrasound-guided biopsies or preoperative localizations, knowledgeable and purposeful scanning adjustments are critical for successfully identifying the targeted mass or biopsy marker or clip. While most ultrasound scanning parameters are similar across different vendors, detailed descriptions specifically addressing the scanning parameters—often referred to as “knobology”— for breast ultrasound is at best limited in the literature. This review highlights ten key operator-controlled adjustments (including transducer selection, beam focusing, power, depth, gain and time gain compensation, harmonic imaging, spatial compounding, dynamic range, beam steering, and color Doppler) that significantly influence image quality in breast ultrasound. Each adjustment is accompanied by an “In practice” section providing examples and practical tips on implementation. The last topic discusses color Doppler which is generally used in breast ultrasound for evaluating the vascularity of a finding. Color Doppler, or more specifically, color Doppler twinkling, can be leveraged as a technique to detect certain breast biopsy markers that are challenging to detect by conventional B-mode ultrasound. While the cause of color Doppler twinkling is still under active investigation, twinkling is a clinically well-known, compelling ultrasound feature typically described with kidney stones. A step-by-step guide on how to use color Doppler twinkling to detect these markers is provided.


  • Open Access

    Randomized Feasibility Study Evaluating Multiple FDA-approved Microbubbles for CEUS Lymphography

    by Samuel Jang, Jess D. Md Rames, Gina K. Hesley, Nathan J. PharmD Brinkman, Nho V. Tran, Vahe Fahradyan, Christine U. Lee

    Summary: Prior studies on contrast-enhanced ultrasound (CEUS) lymphography for preoperative mapping before lymphaticovenous anastomosis surgery in patients with extremity lymphedema have been limited to using only Lumason and Sonazoid as microbubble contrast agents. The purpose of this study was to determine the feasibility of using two other Food & Drug Administration–approved microbubble agents, Optison and Definity, for imaging lymphatic vessels in the upper extremities. Nine female adults with unilateral upper extremity lymphedema anticipating lymphaticovenous anastomosis surgery underwent CEUS lymphography of the unaffected upper extremity randomized to either Lumason, Definity, or Optison. Lymphatic vessels were visualized in all but one case when undilated Definity was used. In the eight upper extremities where lymphatic vessels were visualized, an average of eight intradermal injections of microbubbles were performed in the extremity. Lymphatic vessels could be identified in 57% (36 of 63) of the injections. The effective dilution for each of the microbubble agents is provided. This was the first successful demonstration of lymphatic vessel visualization using either Definity or Optison. Broadening the range of available microbubble agents for CEUS lymphography could improve accessibility to the procedure and provide potentially safer alternatives.


  • Open Access

    3D‐Printed Hollow Microneedles Array with Luer Lock Connection for Facile and Painless Intradermal Injection: A Proof of Concept

    by Amirreza Ghaznavi, Jie Xu, Christine U. Lee, Seth A. Hara

    A 3D‐printed array of hollow microneedles (HMNs) is designed and fabricated using a high‐resolution stereolithography 3D printer and assembled with a 3D‐printed reservoir that incorporates a Luer lock mechanism, ensuring standard and secure connection to syringes. The proof‐of‐concept needle designs consist of half‐eccentric and concentric conical tip shapes, each arrayed with two different interspacing values. After the geometrical features of the devices are characterized, the devices are tested ex vivo in porcine skin to evaluate the impact of tip shape and interspacing on the depth of penetration and the efficacy of the devices in delivering fluids (such as tattoo ink) into the dermis. Overall, the 3D‐printed HMNs can deliver fluids into the target layer of skin. Refinement of the design is ongoing with the ultimate aim to provide alternatives for intradermal drug delivery and diagnostic imaging, such as superficial lymphography.


  • Open Access

    A Radiological Clip Design Using Ultrasound Identification to Improve Localization

    by Jenna Cario, Zhengchang Kou, Rita J. Miller, April Dickenson, Christine U. Lee, Michael L. Oelze

    Objective: We demonstrate the use of ultrasound to receive an acoustic signal transmitted from a radiological clip designed from a custom circuit. This signal encodes an identification number and is localized and identified wirelessly by the ultrasound imaging system. Methods: We designed and constructed the test platform with a Teensy 4.0 microcontroller core to detect ultrasonic imaging pulses received by a transducer embedded in a phantom, which acted as the radiological clip. Ultrasound identification (USID) signals were generated and transmitted as a result. The phantom and clip were imaged using an ultrasonic array (Philips L7-4) connected to a Verasonics ™ Vantage 128 system operating in pulse inversion (PI) mode. Cross-correlations were performed to localize and identify the code sequences in the PI images. Results: USID signals were detected and visualized on B-mode images of the phantoms with up to sub-millimeter localization accuracy. The average detection rate across 30,400 frames of ultrasound data was 98.1%. Conclusion: The USID clip produced identifiable, distinguishable, and localizable signals when imaged. Significance: Radiological clips are used to mark breast cancer being treated by neoadjuvant chemotherapy (NAC) via implant in or near treated lesions. As NAC progresses, available marking clips can lose visibility in ultrasound, the imaging modality of choice for monitoring NAC-treated lesions. By transmitting an active signal, more accurate and reliable ultrasound localization of these clips could be achieved and multiple clips with different ID values could be imaged in the same field of view.