Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Eduardo Venegas-Reyes has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Performance Evaluation, Thermodynamic Analysis and Cost Assessment of a Stand-Alone Desalination Plant Driven with PV-Solar Without Battery Support

    by Manuela Celeste Salgado-Pineda, Jonathan Ibarra-Bahena, Yuridiana Rocio Galindo-Luna, Eduardo Venegas-Reyes, José Agustín Breña-Naranjo, Ulises Dehesa-Carrasco

    Desalination by reverse osmosis (RO) of brackish water and seawater is a cost-competitive solution for supplying irrigation water in off-grid and water-stressed regions. This paper presents an experimental evaluation, thermodynamic analysis, and cost assessment of a solar photovoltaic brackish-water reverse osmosis (PV-BWRO) desalination system. Five feed salinity levels ranging from 993.6 to 3191.8 mg/L were tested. The results show that water production decreased with increasing feed salinity, from 3.29 m3/day at 24.6 mg/L to 1.48 m3/day at 152.9 mg/L. The calculated specific energy consumption values ranged from 1.80 to 3.61 kWh/m3 for solar irradiances of 1005.99 and 1018.47 W/m2, respectively. An exergy analysis revealed that the solar panels and pump operated at efficiencies of 11.7% and 38.9%, while exergy destruction was mainly concentrated in the pretreatment stage (28.72%), membrane modules (42.5%), and reject stream (28.5%). Although the overall system efficiency remained low (maximum of 1.39%), the results highlight substantial potential for improvement through enhanced maintenance, optimized pretreatment, and exergy recovery strategies. The unit water production cost ranged from USD 0.49 at 993.6 mg/L to USD 1.87 at 3191.8 mg/L, assuming a target permeate total dissolved solids concentration of 500 mg/L.

  • Open Access

    Reverse osmosis pilot plant employed for pollutants-free drinking water production from the groundwater Mezquital valley, Mexico: An alternative to solve water scarcity in Metropolitan area

    by Iván Emmanuel Villegas-Mendoza, Angélica Julieta Alvillo-Rivera, Carlos David Silva-Luna, Eduardo Venegas-Reyes, Tania Gutierrez-Macías


  • Open Access

    Comparative Simulation of Solar Adsorption and Absorption Cooling Systems with Latent Heat Storage with Erythritol and MgCl2·6H2O

    by Rosenberg J. Romero, Fernando Lara, Eduardo Venegas-Reyes, Moisés Montiel-Gonzalez, Jesús Cerezo

    The energy requirements for conditioning spaces have been increasing primarily due to population growth and climate change. This paper shows a comparison between an adsorption (ADC) and absorption cooling (ABC) systems to keep a building below the 25 °C set-point in dynamic conditions, utilizing a latent heat storage tank with MgCl2·6H2O and erythritol, and employing evacuated tube and parabolic trough collectors. The storage tank geometry is a plate heat exchanger. An auxiliary system was incorporated to control the temperature range of the solar cooling systems. The results showed that the coefficient of performance was kept around 0.40–0.60 and 0.70 for adsorption and absorption cooling, respectively. The latent heat storage tank with erythritol captured more solar energy than MgCl2·6H2O. A maximum solar fraction of 0.96 was obtained with MgCl2·6H2O, a thickness of 0.15 m, 20 m2 of parabolic trough collector area, and absorption cooling, while the energy supply was fully satisfied with a solar collector with erythritol, a thickness of 0.1 m, 13 m2 of parabolic trough area, and absorption cooling. In general, erythritol obtained better results of solar collector fractions than MCHH; however, it has less thermal stability than MgCl2·6H2O, and the cost is higher.


  • Open Access

    Thermal Performance and Cost Assessment Analysis of a Double-Pass V-Trough Solar Air Heater

    by Eduardo Venegas-Reyes, Naghelli Ortega-Avila, Yuridiana Rocio Galindo-Luna, Jonathan Ibarra-Bahena, Erick Cesar López-Vidaña, Ulises Dehesa-Carrasco

    Solar air heating systems offer an effective alternative for reducing greenhouse gas emissions at a profitable cost. This work details the design, construction, and experimental evaluation of a novel double-pass V-trough solar air heater with semicircular receivers, which was built with low-cost materials readily available in the Mexican market. Thermal performance tests were conducted in accordance with the ANSI-ASHRAE 93-2010 standard. The results indicated a peak collector efficiency of 0.4461 and total heat losses of 8.8793 W/(m2 °C), with an air mass flow rate of 0.0174 kg/s. The instantaneous thermal efficiency varied between 0.2603 and 0.5633 with different air flow rates and an inlet air temperature close to the ambient temperature. The outlet air temperature reached 70 °C, making it suitable for dehydrating fruits or vegetables at competitive operating costs. Additionally, a second-law analysis was carried out, and the exergy efficiency was between 0.0037 and 0.0407. Finally, a Levelized Cost of Energy analysis was performed, and the result was USD 0.079/kWh, which was 31% lower than that of a conventional electric air heater system.


  • Open Access

    Thermal Performance Analysis of a Double-Pass Solar Air Collector: A CFD Approach

    by Irving A. Chávez-Bermúdez, Norma A. Rodríguez-Muñoz, Eduardo Venegas-Reyes, Loreto Valenzuela, Naghelli Ortega-Avila

    Solar air heaters can reduce climate change by replacing conventional fossil fuel-burning technologies in drying and space heating applications. Concentrating solar technologies, such as compound parabolic concentrators, allow air temperatures up to 120 °C; however, it is desirable to improve their heat transfer to reduce the space requirements for their installation. In this work, a parabolic concentrator composed of a flat receiver designed to recover heat from the cover–receiver–reflectors cavity is analyzed, operating it as a U-shape double pass solar heater. With this operation, first, the air flows through the cavity, and then it is incorporated into the duct, where the dominant heat gain occurs due to the capture of solar radiation. Thus, four input–output configurations in the cavity were modeled through dynamic simulations to determine the influence of the inlet and outlet air flow positions on the solar concentrator outlet temperature. Therefore, the incorporation of the first pass has a contribution of between 36% and 45% in useful energy gain, showing that this appropriate and relatively simple strategy can be implemented to improve the thermal performance of solar air collectors, resulting in instantaneous efficiencies higher than 75%. However, the simulation results demonstrate that the position of the inlets and outlets does not significantly impact the efficiency and outlet temperature.


  • Open Access

    A Linear Hybrid Concentrated Photovoltaic Solar Collector: A Methodology Proposal of Optical and Thermal Analysis

    by Eduardo Venegas-Reyes, Naghelli Ortega-Avila, Manuel I. Peña-Cruz, Omar J. García-Ortiz, Norma A. Rodríguez-Muñoz

    The photovoltaic cell surface in linear hybrid concentrated solar collectors receives non-uniform radiative flux, causing additional thermal stress due to hot spots and reducing its electrical performance and durability. The current study proposes a parametric methodology to determine the optimal receiver displacement required in a linear Cassegrain-type hybrid solar collector. The aim was to achieve a minimal non-uniformity distribution and a high radiative flux over the photovoltaic cells, considering optical errors close to real environment conditions and analyzing the heat transfer to determine the electrical and thermal efficiencies. The developed methodology was applied to analyze a case study with a receiver width of 0.125 m and rim angle of 80° and using a commercial silicon photovoltaic cell that supports up to 7000 W/m2. After applying the methodology, a hybrid solar collector with a concentration ratio of 13.0 and receiver displacement of 0.14 m is recommended. As a result, 5728 W/m2 of average radiative flux with non-uniformity lower than 4% was achieved. Thus, thanks to the proposed configuration, a low non-uniformity and high radiative flux were achieved, benefiting the photovoltaic cells’ life while improving their operation.


  • Open Access

    Experimental Performance of a Membrane Desorber Operating under Simulated Warm Weather Condensation Temperatures

    by Jonathan Ibarra-Bahena, Wilfrido Rivera, Sandra Daniela Nanco-Mejía, Rosenberg J. Romero, Eduardo Venegas-Reyes, Ulises Dehesa-Carrasco

    In absorption systems using the aqueous lithium bromide mixture, the Coefficient of Performance is affected by the desorber. The main function of this component is to separate the refrigerant fluid from the working mixture. In conventional boiling desorbers, constant heat flux and vacuum pressure conditions are necessary to carry out the desorption process, and usually, the absorbers are heavy and bulky; thus, they are not suitable in compact systems. In this study, a membrane desorber was evaluated, operating at atmospheric pressure conditions with a water/lithium bromide solution with a concentration of 49.6% w/w. The effects of the solution temperature, solution mass flow, and condensation temperature on the desorption rate were analyzed. The maximum desorption rate value was 6.1 kg/m2h with the following operation conditions: the solution temperature at 95.2 °C, the solution mass flow at 4.00 × 10−2 kg/s, and the cooling water temperature at 30.1 °C. On the other hand, the minimum value was 1.1 kg/m2h with the solution temperature at 80.2 °C, the solution mass flow at 2.50 × 10−2 kg/s, and the cooling water temperature at 45.1 °C. The thermal energy efficiency, defined as the ratio between the thermal energy used to evaporate the refrigerant fluid with respect to the total thermal energy entering the membrane desorber, varied from 0.08 to 0.30. According to the results, a high solution mass flow, a high solution temperature, and a low condensation temperature lead to an increase in the desorption rate; however, a low solution mass flow enhanced the thermal energy efficiency. The proposed membrane desorber could replace a conventional boiling desorber, especially in absorption cooling systems that operate at high condensation temperatures as in warm weather regions.


  • Open Access

    Feasibility Analysis of a Membrane Desorber Powered by Thermal Solar Energy for Absorption Cooling Systems

    by Jonathan Ibarra-Bahena, Eduardo Venegas-Reyes, Yuridiana R. Galindo-Luna, Wilfrido Rivera, Rosenberg J. Romero, Antonio Rodríguez-Martínez, Ulises Dehesa-Carrasco

    In absorption cooling systems, the desorber is a component that separates the refrigerant fluid from the liquid working mixture, most commonly completed by boiling separation; however, the operation temperature of boiling desorbers is generally higher than the low-enthalpy energy, such as solar, geothermal, or waste heat. In this study, we used a hydrophobic membrane desorber to separate water vapor from an aqueous LiBr solution. Influencing factors, such as the H2O/LiBr solution and cooling water temperatures, were tested and analyzed. With the experimental data, a solar collector system was simulated on a larger scale, considering a 1 m2 membrane. The membrane desorber evaluation shows that the desorption rate of water vapor increased as the LiBr solution temperature increased and the cooling water temperature decreased. Based on the experimental data from the membrane desorber/condenser, a theoretical heat load was calculated to size a solar system. Meteorological data from Emiliano Zapata in Mexico were considered. According to the numerical result, nine solar collectors with a total area of 37.4 m2 provide a solar fraction of 0.797. The membrane desorber/condenser coupled to the solar system can provide an average of 16.8 kg/day of refrigerant fluid that can be used to produce a cooling effect in an absorption refrigerant system.


  • Open Access

    Parametric Methodology to Optimize the Sizing of Solar Collector Fields in Series-Parallel Arrays

    by Eduardo Venegas-Reyes, Naghelli Ortega-Avila, Norma A. Rodríguez-Muñoz, Mario Nájera-Trejo, Ignacio R. Martín-Domínguez, Jonathan Ibarra-Bahena

    The analysis of solar thermal systems through numerical simulation is of great importance, since it allows predicting the performance of many configurations in any location and under different climatic conditions. Most of the simulation tools are commercial and require different degrees of training; therefore, it is important to develop simple and reliable methodologies to obtain similar results. This study presents a parametric methodology to size stationary solar collector fields, with operating temperatures up to 150 °C. The costs of the collector loop piping and the pumping power of different series–parallel arrays is considered. The proposed tool was validated with experimental data and through simulations using commercial software. The tool allows establishing series–parallel arrays and calculates the volume of the storage tank according to the thermal load. The calculation is based on the system energy balance, where the mass flow and the heat losses in the interconnections of the collectors are taken into account. The number of collectors and the optimal series–parallel array were determined. The results show deviations lower than 7% in the relative error of the temperature profiles and in the solar fraction, with respect to the results obtained by dynamic simulations.