Peter D. D. Schwindt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Peter D. D. Schwindt has a total of 156 co-authors. Here are the top co-authors by number of shared publications:
Albuquerque Sandia National Laboratories (Snl-Nm)
7 shared publicationsAmir Borna
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
7 shared publications- Joonas Iivanainen
Aalto University, School of Science
5 shared publications Usdoe National Nuclear Security Administration (Nnsa)
5 shared publicationsYuan-Yu Jau
Sandia National Laboratory, 1515 Eubank SE, Albuquerque, New Mexico 87123, USA
5 shared publications- Amir Borna
AO Sensing EC Engineering, Sandia National Laboratories,Albuquerque,NM
4 shared publications
Latest Publications
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
High-Resolution Atomic Magnetometer-Based Imaging of Integrated Circuits and Batteries
Optically pumped magnetometers (OPMs) have emerged as a powerful technique for high-resolution magnetic field imaging. However, achieving sub-millimeter spatial resolution at sub-picotesla sensitivities (< 1 pT/ √ Hz) remains challenging, particularly under finite-field conditions. We present a high-resolution magnetic imaging system based on a free-induction-decay (FID) OPM integrated with a two-axis scanning micromirror for automated beam steering. The double-pass optical configuration allows millimeter-scale devices under test (DUTs) to be positioned directly behind the vapor cell. This enables a standoff distance of 2.7 mm between the magnetic source and the atomic vapor, improving practical imaging resolution by increasing the amplitude of near-field magnetic signals sampled within the sensitive volume. Spatial resolution is experimentally demonstrated by imaging a custom printed circuit board (PCB) containing antiparallel copper tracks spaced 2 mm apart, with measured field maps in close agreement with Biot–Savart predictions. The OPM achieves an optimal field sensitivity of 0.5 pT/ √ Hz, demonstrating the system’s capability for high-precision magnetic field measurements. The imaging system is further validated by resolving polarity-dependent asymmetries in a bridge rectifier integrated circuit (IC) and tracking current dynamics in a ceramic battery in situ. These results highlight the potential of OPM-based systems for noninvasive diagnostics of electronic circuits and batteries.
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
High-Resolution Atomic Magnetometer-Based Imaging of Integrated Circuits and Batteries
Optically pumped magnetometers (OPMs) have emerged as a powerful technique for high-resolution magnetic field imaging. However, achieving sub-millimeter spatial resolution at sub-picotesla sensitivities (< 1 pT/ √ Hz) remains challenging, particularly under finite-field conditions. We present a high-resolution magnetic imaging system based on a free-induction-decay (FID) OPM integrated with a two-axis scanning micromirror for automated beam steering. The double-pass optical configuration allows millimeter-scale devices under test (DUTs) to be positioned directly behind the vapor cell. This enables a standoff distance of 2.7 mm between the magnetic source and the atomic vapor, improving practical imaging resolution by increasing the amplitude of near-field magnetic signals sampled within the sensitive volume. Spatial resolution is experimentally demonstrated by imaging a custom printed circuit board (PCB) containing antiparallel copper tracks spaced 2 mm apart, with measured field maps in close agreement with Biot–Savart predictions. The OPM achieves an optimal field sensitivity of 0.5 pT/ √ Hz, demonstrating the system’s capability for high-precision magnetic field measurements. The imaging system is further validated by resolving polarity-dependent asymmetries in a bridge rectifier integrated circuit (IC) and tracking current dynamics in a ceramic battery in situ. These results highlight the potential of OPM-based systems for noninvasive diagnostics of electronic circuits and batteries.
- Open Access
- 11 August 2025
- Published by Office of Scientific and Technical Information (OSTI)
Modeling of spin squeezing in OPMs and performance improvements
- 11 August 2025
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessModeling of spin squeezing in OPMs and performance improvements
- Open Access
- 1 July 2025
- Published by Office of Scientific and Technical Information (OSTI)
Multiplexed Electro-Optical Dual-Comb Spectroscopy
- 1 July 2025
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessMultiplexed Electro-Optical Dual-Comb Spectroscopy
- Open Access
- 1 March 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (13)
Performance of 3 cm3 ion trap vacuum package sealed for 10 years
Miniature atomic clocks based on the interrogation of the ground state hyperfine splitting of buffer gas cooled ions confined in radio frequency Paul traps have shown great promise as high precision prototype clocks. We report on the performance of two miniature ion trap vacuum packages after being sealed for as much as 10 years. We find the lifetime of the ions within the trap has increased over time for both traps and can be as long as 50 days. We form two clocks using the two traps and compare their relative frequency instability one with another to demonstrate a short-term instability of 5×10−13τ−1/2 integrating down to 1×10−14 after 2 ks of integration. The trapped ion lifetime and clock instability demonstrated by these miniature devices despite only being passively pumped for many years represents a critical advance toward their proliferation in the clock community.
- 1 March 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (13)
Open AccessPerformance of 3 cm3 ion trap vacuum package sealed for 10 years
Miniature atomic clocks based on the interrogation of the ground state hyperfine splitting of buffer gas cooled ions confined in radio frequency Paul traps have shown great promise as high precision prototype clocks. We report on the performance of two miniature ion trap vacuum packages after being sealed for as much as 10 years. We find the lifetime of the ions within the trap has increased over time for both traps and can be as long as 50 days. We form two clocks using the two traps and compare their relative frequency instability one with another to demonstrate a short-term instability of 5×10−13τ−1/2 integrating down to 1×10−14 after 2 ks of integration. The trapped ion lifetime and clock instability demonstrated by these miniature devices despite only being passively pumped for many years represents a critical advance toward their proliferation in the clock community.
- Open Access
- 1 October 2024
- Published by Office of Scientific and Technical Information (OSTI)
Toward an Optically Pumped Magnetometer Magnetoencephalography System with Full Head Coverage
An overview of recent development of our MEG system. Most of the included data/figures are already published in the open literature.
- 1 October 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessToward an Optically Pumped Magnetometer Magnetoencephalography System with Full Head Coverage
An overview of recent development of our MEG system. Most of the included data/figures are already published in the open literature.
- Open Access
- 1 August 2024
- Published by Office of Scientific and Technical Information (OSTI)
Introduction to Optically Pumped Magnetometers (OPMs)
- 1 August 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessIntroduction to Optically Pumped Magnetometers (OPMs)
- Open Access
- 29 July 2024
- Published by Springer Nature in Communications Biology
- Vol. 7 (1) , 1-16
Non-invasive ventral cervical magnetoneurography as a proxy of in vivo lipopolysaccharide-induced inflammation
Maintenance of autonomic homeostasis is continuously calibrated by sensory fibers of the vagus nerve and sympathetic chain that convey compound action potentials (CAPs) to the central nervous system. Lipopolysaccharide (LPS) intravenous challenge reliably elicits a robust inflammatory response that can resemble systemic inflammation and acute endotoxemia. Here, we administered LPS intravenously in nine healthy subjects while recording ventral cervical magnetoneurography (vcMNG)-derived CAPs at the rostral Right Nodose Ganglion (RNG) and the caudal Right Carotid Artery (RCA) with optically pumped magnetometers (OPM). We observed vcMNG RNG and RCA neural firing rates that tracked changes in TNF-α levels in the systemic circulation. Further, endotype subgroups based on high and low IL-6 responders segregate RNG CAP frequency (at 30-120 min) and based on high and low IL-10 response discriminate RCA CAP frequency (at 0-30 min). These vcMNG tools may enhance understanding and management of the neuroimmune axis that can guide personalized treatment based on an individual’s distinct endophenotype.
- 29 July 2024
- Published by Springer Nature in Communications Biology
- Vol. 7 (1) , 1-16
Open AccessNon-invasive ventral cervical magnetoneurography as a proxy of in vivo lipopolysaccharide-induced inflammation
Maintenance of autonomic homeostasis is continuously calibrated by sensory fibers of the vagus nerve and sympathetic chain that convey compound action potentials (CAPs) to the central nervous system. Lipopolysaccharide (LPS) intravenous challenge reliably elicits a robust inflammatory response that can resemble systemic inflammation and acute endotoxemia. Here, we administered LPS intravenously in nine healthy subjects while recording ventral cervical magnetoneurography (vcMNG)-derived CAPs at the rostral Right Nodose Ganglion (RNG) and the caudal Right Carotid Artery (RCA) with optically pumped magnetometers (OPM). We observed vcMNG RNG and RCA neural firing rates that tracked changes in TNF-α levels in the systemic circulation. Further, endotype subgroups based on high and low IL-6 responders segregate RNG CAP frequency (at 30-120 min) and based on high and low IL-10 response discriminate RCA CAP frequency (at 0-30 min). These vcMNG tools may enhance understanding and management of the neuroimmune axis that can guide personalized treatment based on an individual’s distinct endophenotype.
- Open Access
- 12 July 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (28) , eade4454
High-performance silicon photonic single-sideband modulators for cold-atom interferometry
The laser system is the most complex component of a light-pulse atom interferometer (LPAI), controlling frequencies and intensities of multiple laser beams to configure quantum gravity and inertial sensors. Its main functions include cold-atom generation, state preparation, state-selective detection, and generating a coherent two-photon process for the light-pulse sequence. To achieve substantial miniaturization and ruggedization, we integrate key laser system functions onto a photonic integrated circuit. Our study focuses on a high-performance silicon photonic suppressed-carrier single-sideband (SC-SSB) modulator at 1560 nanometers, capable of dynamic frequency shifting within the LPAI. By independently controlling radio frequency (RF) channels, we achieve 30-decibel carrier suppression and unprecedented 47.8-decibel sideband suppression at peak conversion efficiency of −6.846 decibels (20.7%). We investigate imbalances in both amplitudes and phases between the RF signals. Using this modulator, we demonstrate cold-atom generation, state-selective detection, and atom interferometer fringes to estimate gravitational acceleration, g ≈ 9.77 ± 0.01 meters per second squared, in a rubidium ( 87 Rb) atom system.
- 12 July 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (28) , eade4454
Open AccessHigh-performance silicon photonic single-sideband modulators for cold-atom interferometry
The laser system is the most complex component of a light-pulse atom interferometer (LPAI), controlling frequencies and intensities of multiple laser beams to configure quantum gravity and inertial sensors. Its main functions include cold-atom generation, state preparation, state-selective detection, and generating a coherent two-photon process for the light-pulse sequence. To achieve substantial miniaturization and ruggedization, we integrate key laser system functions onto a photonic integrated circuit. Our study focuses on a high-performance silicon photonic suppressed-carrier single-sideband (SC-SSB) modulator at 1560 nanometers, capable of dynamic frequency shifting within the LPAI. By independently controlling radio frequency (RF) channels, we achieve 30-decibel carrier suppression and unprecedented 47.8-decibel sideband suppression at peak conversion efficiency of −6.846 decibels (20.7%). We investigate imbalances in both amplitudes and phases between the RF signals. Using this modulator, we demonstrate cold-atom generation, state-selective detection, and atom interferometer fringes to estimate gravitational acceleration, g ≈ 9.77 ± 0.01 meters per second squared, in a rubidium ( 87 Rb) atom system.