Kaiyang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kaiyang Li has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Lin Wang
Wuhan University, School of Physics and Technology, Department of Electronic Science and Technology, No. 299, Bayi Road, Wuchang District, Wuhan City, Hubei Province 430072, China
4 shared publicationsChengwen Liang
Department of Electronic Science and Technology, School of Physics and Technology, Wuhan University, Wuhan 430072, China
2 shared publicationsFei Han
Department of Electronic Science and Technology, School of Physics and Technology, Wuhan University, Wuhan 430072, China
2 shared publicationsGuilian Shi
Department of Electronic Science and Technology, School of Physics and Technology, Wuhan University, Wuhan 430072, China ; School of Biomedical Engineering, Hubei University of Science and Technology, Xianning 437100, China
2 shared publicationsMeng Rong
Wuhan University, School of Physics and Technology, Department of Electronic Science and Technology, No. 299, Bayi Road, Wuchang District, Wuhan City, Hubei Province 430072, China
2 shared publications- Daoming Zhu
Department of General Surgery Guangdong Provincial Key Laboratory of Precision Medicine for Gastrointestinal Tumor Nanfang Hospital Southern Medical University Guangzhou Guangdong 510515 China
1 shared publication
Latest Publications
- 1 October 2024
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 208
Simulation and clinical validation of the breast temperature field based on a multi-point heat source model
- 1 October 2024
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 208
Simulation and clinical validation of the breast temperature field based on a multi-point heat source model
- 12 May 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 8 (24) , 5312-5319
A biomimetic nanozyme/camptothecin hybrid system for synergistically enhanced radiotherapy
Although radiotherapy (RT) has been an effective therapeutic regimen against most solid tumors, its effect is limited by the hypoxic tumor microenvironment and radio-tolerance of tumor cells to a large extent. Here we have designed a biomimetic nanozyme/camptothecin hybrid system for synergistically enhanced radiotherapy, which consists of an internal camptothecin (CPT)-loaded hollow MnO2 core and an external tumor cell membrane. The tumor cell membrane endows the system with excellent tumor targeting ability. The hollow MnO2 core can deliver the hydrophobic drug CPT and catalyze the production of oxygen from hydrogen peroxide in tumor tissues, which was finally degraded into Mn2+, a T1-weighted contrast agent. The anti-tumor mechanism of this system includes two aspects: (i) the generated oxygen can improve the hypoxic state of the tumor microenvironment and enhance the radiotherapy sensitivity and (ii) CPT can induce cell cycle arrest in the S-phase at a low dose, which further increases the radio-sensitivity of tumor cells and augmented radiation-induced tumor damage. The results of in vivo experiments showed that the biomimetic nanozyme drug delivery system improved the hypoxic microenvironment of the tumor tissue with a high tumor inhibition rate in a murine model. This platform achieved synergistic radiotherapy sensitization and provided a novel idea for the design of a radiotherapy sensitization system.
- 12 May 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 8 (24) , 5312-5319
A biomimetic nanozyme/camptothecin hybrid system for synergistically enhanced radiotherapy
Although radiotherapy (RT) has been an effective therapeutic regimen against most solid tumors, its effect is limited by the hypoxic tumor microenvironment and radio-tolerance of tumor cells to a large extent. Here we have designed a biomimetic nanozyme/camptothecin hybrid system for synergistically enhanced radiotherapy, which consists of an internal camptothecin (CPT)-loaded hollow MnO2 core and an external tumor cell membrane. The tumor cell membrane endows the system with excellent tumor targeting ability. The hollow MnO2 core can deliver the hydrophobic drug CPT and catalyze the production of oxygen from hydrogen peroxide in tumor tissues, which was finally degraded into Mn2+, a T1-weighted contrast agent. The anti-tumor mechanism of this system includes two aspects: (i) the generated oxygen can improve the hypoxic state of the tumor microenvironment and enhance the radiotherapy sensitivity and (ii) CPT can induce cell cycle arrest in the S-phase at a low dose, which further increases the radio-sensitivity of tumor cells and augmented radiation-induced tumor damage. The results of in vivo experiments showed that the biomimetic nanozyme drug delivery system improved the hypoxic microenvironment of the tumor tissue with a high tumor inhibition rate in a murine model. This platform achieved synergistic radiotherapy sensitization and provided a novel idea for the design of a radiotherapy sensitization system.
- 2 August 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (9) , 4031-4053
Light transport in homogeneous tissue with m-dependent anisotropic scattering II: Fourier transform solution and consistent relations
This paper is the second of two focusing on the analytical solutions for light transport in infinite homogeneous tissue with an azimuth-dependent (m-dependent) anisotropic scattering kernel by two approaches, Case’s singular eigenfuncions (CSEs) expansion and Fourier transform, and proving the consistence of the two solutions theoretically. In this paper, the analytical solution for the m-dependent truncated scattering kernel was derived via the Fourier transform and inversion, and expanded with the m-dependent generalized singular eigenfuncions (GSEs). Two kinds of GSEs that are defined by Ganapol in the case are extended to arbitrary azimuthal orders and proven to be consistent with CSEs both in expression forms and in intrinsic behaviors. By applying the Fourier transform inversion on the solution for the three-term recurrences, the Green’s function of radiance distributions is obtained successfully, and it conforms perfectly to the CSEs solution in the limit, which has already been discussed in our first accompanying paper. Meanwhile, as a byproduct, a series of identities about the m-dependent Chandrasekhar orthogonal polynomials were presented and will be greatly helpful for further studies.- 2 August 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (9) , 4031-4053
Light transport in homogeneous tissue with m-dependent anisotropic scattering II: Fourier transform solution and consistent relations
This paper is the second of two focusing on the analytical solutions for light transport in infinite homogeneous tissue with an azimuth-dependent (m-dependent) anisotropic scattering kernel by two approaches, Case’s singular eigenfuncions (CSEs) expansion and Fourier transform, and proving the consistence of the two solutions theoretically. In this paper, the analytical solution for the m-dependent truncated scattering kernel was derived via the Fourier transform and inversion, and expanded with the m-dependent generalized singular eigenfuncions (GSEs). Two kinds of GSEs that are defined by Ganapol in the case are extended to arbitrary azimuthal orders and proven to be consistent with CSEs both in expression forms and in intrinsic behaviors. By applying the Fourier transform inversion on the solution for the three-term recurrences, the Green’s function of radiance distributions is obtained successfully, and it conforms perfectly to the CSEs solution in the limit, which has already been discussed in our first accompanying paper. Meanwhile, as a byproduct, a series of identities about the m-dependent Chandrasekhar orthogonal polynomials were presented and will be greatly helpful for further studies.- 2 August 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (9) , 4009-4030
Light transport in homogeneous tissue with m-dependent anisotropic scattering I: Case’s singular eigenfunctions solution and Chandrasekhar polynomials
This paper is the first of two deriving the analytical solutions for light transport in infinite homogeneous tissue with an azimuth-dependent (m-dependent) anisotropic scattering kernel by two approaches, Case’s singular eigenfuncions expansion and Fourier transform, as well as proving the consistence of the two solutions. In this paper, Case’s method was applied and extended to the general m-dependent anisotropic scattering case. The explicit Green’s function of radiance distributions, which was regarded as the comparative standard for the equivalent solution via Fourier transform and inversion in our second accompanying paper, was expanded into a complete set of the discrete and continuous eigenfunctions. Considering that the two kinds of m-dependent Chandrasekhar orthogonal polynomials that play vital roles in these analytical solutions are very sensitive to the typical optical parameters of biological tissue as well as the degrees or orders, four numerical evaluation methods were benchmarked to find the stable, reliable and feasible numerical evaluation methods in high degrees and high orders.
- 2 August 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (9) , 4009-4030
Light transport in homogeneous tissue with m-dependent anisotropic scattering I: Case’s singular eigenfunctions solution and Chandrasekhar polynomials
This paper is the first of two deriving the analytical solutions for light transport in infinite homogeneous tissue with an azimuth-dependent (m-dependent) anisotropic scattering kernel by two approaches, Case’s singular eigenfuncions expansion and Fourier transform, as well as proving the consistence of the two solutions. In this paper, Case’s method was applied and extended to the general m-dependent anisotropic scattering case. The explicit Green’s function of radiance distributions, which was regarded as the comparative standard for the equivalent solution via Fourier transform and inversion in our second accompanying paper, was expanded into a complete set of the discrete and continuous eigenfunctions. Considering that the two kinds of m-dependent Chandrasekhar orthogonal polynomials that play vital roles in these analytical solutions are very sensitive to the typical optical parameters of biological tissue as well as the degrees or orders, four numerical evaluation methods were benchmarked to find the stable, reliable and feasible numerical evaluation methods in high degrees and high orders.
- 20 June 2017
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 37 (5) , 675-685
Noncontact Imaging Plethysmography for Accurate Estimation of Physiological Parameters
- 20 June 2017
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 37 (5) , 675-685
Noncontact Imaging Plethysmography for Accurate Estimation of Physiological Parameters
- Open Access
- 3 March 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (4) , 1109-1123
Q-r curve of thermal tomography and its clinical application on breast tumor diagnosis
Heat is the product following the metabolism of cells, and the metabolism is closely related with the pathological information of living organism. So, there are strong ties between the heat distribution and the pathological state in living organism. In this paper, the mathematical function δ is introduced in the classical Pennes bio-heat transfer equation as the point heat source. By simplifying the boundary conditions, a novel bio-heat transfer model is established and solved in a spherical coordinate system. Based on the temperature distribution of human body surface, the information of heat source is mined layer by layer, and the corresponding q-r curve of heat intensity varying with depth is acquired combining the fitting method of Lorentz curve. According to a large number of clinical confirmed cases and statistics, the diagnostic criteria judging diseases by q-r curve are proposed. Five typical clinical practices are performed and four of the diagnosis results are very consistent with those of molybdenum target (MT) X-ray, B-ultrasonic images and pathological examination, one gives the result of early stage malignant tumor that MT X-ray and B-ultrasonic can’t check out. It is a radiation-free green method with noninvasive diagnostic procedure and accurate diagnosis result.
- 3 March 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (4) , 1109-1123
Open AccessQ-r curve of thermal tomography and its clinical application on breast tumor diagnosis
Heat is the product following the metabolism of cells, and the metabolism is closely related with the pathological information of living organism. So, there are strong ties between the heat distribution and the pathological state in living organism. In this paper, the mathematical function δ is introduced in the classical Pennes bio-heat transfer equation as the point heat source. By simplifying the boundary conditions, a novel bio-heat transfer model is established and solved in a spherical coordinate system. Based on the temperature distribution of human body surface, the information of heat source is mined layer by layer, and the corresponding q-r curve of heat intensity varying with depth is acquired combining the fitting method of Lorentz curve. According to a large number of clinical confirmed cases and statistics, the diagnostic criteria judging diseases by q-r curve are proposed. Five typical clinical practices are performed and four of the diagnosis results are very consistent with those of molybdenum target (MT) X-ray, B-ultrasonic images and pathological examination, one gives the result of early stage malignant tumor that MT X-ray and B-ultrasonic can’t check out. It is a radiation-free green method with noninvasive diagnostic procedure and accurate diagnosis result.
- 7 September 2014
- Published by Springer Nature in Cell Biochemistry and Biophysics
- Vol. 71 (1) , 491-498
A Simple and Efficient Method for Breast Cancer Diagnosis Based on Infrared Thermal Imaging
This study aims to evaluate the feasibility and efficacy of quantitative diagnosis through thermal analysis of abnormal metabolism. In this paper, an analytical-based steady-state solution for the thermal inverse problem was developed, considering an equivalent point heat source embedded in the tissue. Based on this solution, we developed a simple and efficient algorithm that generates solutions for the nonlinear heat conduction model. Using the nonlinear fitting analysis, a regular distribution can be derived from the raw thermal patterns of the skin surface above the tumor, and the power and depth of the equivalent heat source can be derived to investigate whether the tumor is malignant or benign. The thermal power Q of internal heat source was estimated to predict the satisfactory approaches to distinguish between benign and malignant tumors. The results of four clinical cases (female patients with malignant tumor and benign tumor) show that the estimated values of the power of the heat sources in malignant cases (fatty: Q = 0.34851 W; dense: Q = 0.46933 W) are both far greater than the ones in benign (fatty: Q = 0.04721 W; dense: Q = 0.07717 W), irregardless of the breast density. The correlation coefficients (R 2) of the nonlinear curve fittings are all above 0.98. The new thermal method proposed in this study would help to improve the preciseness of diagnosis on breast masses (malignant or benign).
- 7 September 2014
- Published by Springer Nature in Cell Biochemistry and Biophysics
- Vol. 71 (1) , 491-498
A Simple and Efficient Method for Breast Cancer Diagnosis Based on Infrared Thermal Imaging
This study aims to evaluate the feasibility and efficacy of quantitative diagnosis through thermal analysis of abnormal metabolism. In this paper, an analytical-based steady-state solution for the thermal inverse problem was developed, considering an equivalent point heat source embedded in the tissue. Based on this solution, we developed a simple and efficient algorithm that generates solutions for the nonlinear heat conduction model. Using the nonlinear fitting analysis, a regular distribution can be derived from the raw thermal patterns of the skin surface above the tumor, and the power and depth of the equivalent heat source can be derived to investigate whether the tumor is malignant or benign. The thermal power Q of internal heat source was estimated to predict the satisfactory approaches to distinguish between benign and malignant tumors. The results of four clinical cases (female patients with malignant tumor and benign tumor) show that the estimated values of the power of the heat sources in malignant cases (fatty: Q = 0.34851 W; dense: Q = 0.46933 W) are both far greater than the ones in benign (fatty: Q = 0.04721 W; dense: Q = 0.07717 W), irregardless of the breast density. The correlation coefficients (R 2) of the nonlinear curve fittings are all above 0.98. The new thermal method proposed in this study would help to improve the preciseness of diagnosis on breast masses (malignant or benign).
- 1 May 2008
- Published by IOP Publishing in Chinese Physics Letters
- Vol. 25 (5) , 1776-1779
Surface Plasmon Resonance and Field Enhancement of Au/Ag Alloyed Hollow Nanoshells
We investigate the nanostructure, surface plasmon resonance (SPR) absorption and nonlinear enhancement of Au/Ag alloyed hollow nanoshells prepared by the replacement reaction of Ag nanoparticles in a HAuCl4 aqueous solution. As the volume of HAuCl4 increases from 0mL to 0.5 mL, the SPR band of the Au/Ag alloyed nanoshells is tuned from 430 nm to 780 nm, and the third-order nonlinear optical susceptibility is enhanced nearly by an order of magnitude, which indicates a large enhancement of local field in the Au/Ag alloyed hollow nanoshells with hole defects.
- 1 May 2008
- Published by IOP Publishing in Chinese Physics Letters
- Vol. 25 (5) , 1776-1779
Surface Plasmon Resonance and Field Enhancement of Au/Ag Alloyed Hollow Nanoshells
We investigate the nanostructure, surface plasmon resonance (SPR) absorption and nonlinear enhancement of Au/Ag alloyed hollow nanoshells prepared by the replacement reaction of Ag nanoparticles in a HAuCl4 aqueous solution. As the volume of HAuCl4 increases from 0mL to 0.5 mL, the SPR band of the Au/Ag alloyed nanoshells is tuned from 430 nm to 780 nm, and the third-order nonlinear optical susceptibility is enhanced nearly by an order of magnitude, which indicates a large enhancement of local field in the Au/Ag alloyed hollow nanoshells with hole defects.
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 11, 939-943
The Application of Wavelet Transform to Breast Near-Infrared Images
Near-infrared imaging is a method of lossless imaging, but the images got by this method have bad contrast and obscure edge, these make diagnosis difficult to make. In this article, after briefly introducing the basic theory, aiming at the multi-resolution of wavelet, a new method of image enhancement has been presented. After preliminary denoising, the noise is restrained by this method of image enhancement. Finally, another transformed image with other method is simply fused with the image we have just got. The results show that images finally got have higher diagnostic value
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 11, 939-943
The Application of Wavelet Transform to Breast Near-Infrared Images
Near-infrared imaging is a method of lossless imaging, but the images got by this method have bad contrast and obscure edge, these make diagnosis difficult to make. In this article, after briefly introducing the basic theory, aiming at the multi-resolution of wavelet, a new method of image enhancement has been presented. After preliminary denoising, the noise is restrained by this method of image enhancement. Finally, another transformed image with other method is simply fused with the image we have just got. The results show that images finally got have higher diagnostic value
- 1 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21527431,p. 1503-1508
A Novel Method of Detecting Calcifications from Mammogram Images Based on Wavelet and Sobel Detector
Mammography is the most widely used and the most efficient method for detection of breast cancer. In which, calcifications are the most important signs of breast cancers. In order to help the radiologist read the mammograms more efficiently, detection of calcifications becomes a significant problem for the computer-aid diagnosis. A novel method of detecting calcifications from mammogram images based on wavelet transformation and Sobel detector, is introduced in this paper. A wavelet based image enhancement technique and the Sobel gradient operator are used consequently, to distinguish the calcifications from the breast tissues
- 1 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21527431,p. 1503-1508
A Novel Method of Detecting Calcifications from Mammogram Images Based on Wavelet and Sobel Detector
Mammography is the most widely used and the most efficient method for detection of breast cancer. In which, calcifications are the most important signs of breast cancers. In order to help the radiologist read the mammograms more efficiently, detection of calcifications becomes a significant problem for the computer-aid diagnosis. A novel method of detecting calcifications from mammogram images based on wavelet transformation and Sobel detector, is introduced in this paper. A wavelet based image enhancement technique and the Sobel gradient operator are used consequently, to distinguish the calcifications from the breast tissues