Leonid A. Konopelko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Leonid A. Konopelko has a total of 237 co-authors. Here are the top co-authors by number of shared publications:
O. G. Popov
D. I. Mendeleyev Institute for Metrology (VNIIM)
4 shared publicationsA. V. Kolobova
Mendeleev All-Russia Research Institute of Metrology (VNIIM)
3 shared publications- Anna V. Kolobova
D. I. Mendeleyev Institute for Metrology
3 shared publications T. A. Popova
Mendeleev All-Russia Research Institute of Metrology (VNIIM), St. Petersburg, Russia
3 shared publicationsYu. A. Kustikov
Mendeleev All-Russia Research Institute of Metrology
3 shared publications- Adriaan M. H. van der Veen
Van Swinden Laboratorium, Department of Chemistry, Thijsseweg 11, 2629 JA Delft, The Netherlands, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 26 March 2021
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 16 (4) , 17-26
Traceability assurance of results of measurements for pollutant substances content in industrial emissions by automatic measuring systems
The results of the development of a gas mixing and analytical stand (reference complex) for testing in order to approve the type of automatic measuring systems (AMS) for determining the content of pollutants in industrial emissions are presented. During the use of the AMS test bench, the units of molar fraction and mass concentration are transferred from the State primary standard of units of molar fraction, mass fraction and mass concentration of components in gas and gas condensate media GET 154 to the tested measuring gas channels of AMS, thereby ensuring traceability of AMS measurement results to the State primary standard GET 154.
- 26 March 2021
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 16 (4) , 17-26
Open AccessTraceability assurance of results of measurements for pollutant substances content in industrial emissions by automatic measuring systems
The results of the development of a gas mixing and analytical stand (reference complex) for testing in order to approve the type of automatic measuring systems (AMS) for determining the content of pollutants in industrial emissions are presented. During the use of the AMS test bench, the units of molar fraction and mass concentration are transferred from the State primary standard of units of molar fraction, mass fraction and mass concentration of components in gas and gas condensate media GET 154 to the tested measuring gas channels of AMS, thereby ensuring traceability of AMS measurement results to the State primary standard GET 154.
- Open Access
- 27 January 2021
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 16 (3) , 23-35
State primary standard of units of molar part, mass part and mass concentration of components in gas and gas condensate environs GET 154-2019
Государственный первичный эталон единиц молярной доли, массовой доли и массовой концентрации компонентов в газовых и газоконденсатных средах ГЭТ 154-2019
- 27 January 2021
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 16 (3) , 23-35
Open AccessState primary standard of units of molar part, mass part and mass concentration of components in gas and gas condensate environs GET 154-2019
Государственный первичный эталон единиц молярной доли, массовой доли и массовой концентрации компонентов в газовых и газоконденсатных средах ГЭТ 154-2019
- 1 January 2021
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 7
Development of international key comparisons in the field of chemico-analytical measurements
The most challenging goals in the field of chemico- and bioanalytical measurements are described. Solutions of these problems are presented, which are being solved in particular by participating in new international comparisons organized by the Cosultative Committee on the Amount of Substance of the International Committee on Weights and Measures (CCQM CIPM). The purposes and tasks of developing key comparisons in the following areas are described: isotopic measurements; determination of the purity of substances; organic analysis; bioanalytical measurements; measurements of aerosol particle parameters; measurements in the field of gas analysis and electrochemistry. It is shown that participation in international key comparisons makes it possible to obtain valid and reliable results of measurements of the composition and properties of gas and liquid media, as well as solid substances and materials.
- 1 January 2021
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 7
Development of international key comparisons in the field of chemico-analytical measurements
The most challenging goals in the field of chemico- and bioanalytical measurements are described. Solutions of these problems are presented, which are being solved in particular by participating in new international comparisons organized by the Cosultative Committee on the Amount of Substance of the International Committee on Weights and Measures (CCQM CIPM). The purposes and tasks of developing key comparisons in the following areas are described: isotopic measurements; determination of the purity of substances; organic analysis; bioanalytical measurements; measurements of aerosol particle parameters; measurements in the field of gas analysis and electrochemistry. It is shown that participation in international key comparisons makes it possible to obtain valid and reliable results of measurements of the composition and properties of gas and liquid media, as well as solid substances and materials.
- 1 May 2020
- Published by Pleiades Publishing Ltd in Optics and Spectroscopy
- Vol. 128 (5) , 678-685
Investigation of Spectral Characteristics of an Optical-Absorption Gas Analyzer for Monitoring Freons in the Air
An optical scheme of an optical absorption gas analyzer optimized for measuring the freon content has been presented. A radiation source with a given maximum spectral density of energy luminosity in the range from 8 to 10 μm with a reference channel of 9.5 μm and a measurement threshold of 1 ppm has been developed and studied. The design of the interference filter system has been developed.
- 1 May 2020
- Published by Pleiades Publishing Ltd in Optics and Spectroscopy
- Vol. 128 (5) , 678-685
Investigation of Spectral Characteristics of an Optical-Absorption Gas Analyzer for Monitoring Freons in the Air
An optical scheme of an optical absorption gas analyzer optimized for measuring the freon content has been presented. A radiation source with a given maximum spectral density of energy luminosity in the range from 8 to 10 μm with a reference channel of 9.5 μm and a measurement threshold of 1 ppm has been developed and studied. The design of the interference filter system has been developed.
- Open Access
- 23 March 2020
- Published by Copernicus GmbH
Concentration dependence and scale linearity of the carbon isotope ratio measurement systems based on CRDS
Isotope ratio measurement systems based on optical spectrometers becomes widely used because of several important advantages. First is fundamental possibility to distinguish the isotopologues with the same molecular weight but different isotopic composition like 16O13C16O and 16O12C17O. Second is fundamental possibility to perform calibration free absolute measurement of different isotopologues based on ab initio calculations of line intensities [1]. Third is experimental usability, field deployability and low cost of the optical instruments.The disadvantage of the optical isotope ratio spectrometers available on the market compared to the isotope ratio mass spectrometers is still low accuracy associated not only with the capabilities of optical instruments as such, but also with the lack of high-precision measurement procedures. To improve the accuracy of the optical measurement system, the main factors affecting the measurement result should be investigated and eliminated.In this study, we used CM-CRDS carbon isotope ratio measurement system consisted of Picarro G2131i analyzer, Picarro combustion module, Picarro Caddy Universal interface, homemade system of solenoid valves Camozzi. The calibration of the measurement system was made by combustion of certified reference materials from the International Atomic Energy Agency as recommended in [2]. The linearity of the delta scale was evaluated. Non-linearity of the delta scale leads to a bias if just one or two certified reference materials are used for calibration.The measurement procedure of carbon isotope ratios in solid sample on CM-CRDS is as follows. A sample is broken down into elemental components in the combustion module. After the cleaning from interfering components, CO2 is diluted with nitrogen and analyzed by CRDS instrument. The similar procedure is performed with reference material. The issue is that even if the mass of sample and reference material are the same, the concentration of CO2 in the analyzed mixture is different. Mismatch of concentrations leads to bias in measured isotope ratios. The magnitude of concentration dependence is estimated in this study.The obtained results are discussed and ways to eliminate the abovementioned issues are proposed. [1] Polyansky, Oleg & Bielska, Katarzyna & Ghysels, Mélanie & Lodi, Lorenzo & Zobov, Nikolai & Hodges, Joseph & Tennyson, Jonathan. (2015). High-Accuracy CO2 Line Intensities Determined from Theory and Experiment. Physical Review Letters. 114. 10.1103/PhysRevLett.114.243001.[2] Willi A. Brand et al. Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report). Pure Appl. Chem., 2014, 86(3), Pages 425–467
- 23 March 2020
- Published by Copernicus GmbH
Open AccessConcentration dependence and scale linearity of the carbon isotope ratio measurement systems based on CRDS
Isotope ratio measurement systems based on optical spectrometers becomes widely used because of several important advantages. First is fundamental possibility to distinguish the isotopologues with the same molecular weight but different isotopic composition like 16O13C16O and 16O12C17O. Second is fundamental possibility to perform calibration free absolute measurement of different isotopologues based on ab initio calculations of line intensities [1]. Third is experimental usability, field deployability and low cost of the optical instruments.The disadvantage of the optical isotope ratio spectrometers available on the market compared to the isotope ratio mass spectrometers is still low accuracy associated not only with the capabilities of optical instruments as such, but also with the lack of high-precision measurement procedures. To improve the accuracy of the optical measurement system, the main factors affecting the measurement result should be investigated and eliminated.In this study, we used CM-CRDS carbon isotope ratio measurement system consisted of Picarro G2131i analyzer, Picarro combustion module, Picarro Caddy Universal interface, homemade system of solenoid valves Camozzi. The calibration of the measurement system was made by combustion of certified reference materials from the International Atomic Energy Agency as recommended in [2]. The linearity of the delta scale was evaluated. Non-linearity of the delta scale leads to a bias if just one or two certified reference materials are used for calibration.The measurement procedure of carbon isotope ratios in solid sample on CM-CRDS is as follows. A sample is broken down into elemental components in the combustion module. After the cleaning from interfering components, CO2 is diluted with nitrogen and analyzed by CRDS instrument. The similar procedure is performed with reference material. The issue is that even if the mass of sample and reference material are the same, the concentration of CO2 in the analyzed mixture is different. Mismatch of concentrations leads to bias in measured isotope ratios. The magnitude of concentration dependence is estimated in this study.The obtained results are discussed and ways to eliminate the abovementioned issues are proposed. [1] Polyansky, Oleg & Bielska, Katarzyna & Ghysels, Mélanie & Lodi, Lorenzo & Zobov, Nikolai & Hodges, Joseph & Tennyson, Jonathan. (2015). High-Accuracy CO2 Line Intensities Determined from Theory and Experiment. Physical Review Letters. 114. 10.1103/PhysRevLett.114.243001.[2] Willi A. Brand et al. Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report). Pure Appl. Chem., 2014, 86(3), Pages 425–467
- 2 December 2019
- Published by Springer Nature in Measurement Techniques
- Vol. 62 (9) , 840-847
Development of a New Generation of Reference Samples of Aluminum Alloys with a Low Hydrogen Concentration
- 2 December 2019
- Published by Springer Nature in Measurement Techniques
- Vol. 62 (9) , 840-847
Development of a New Generation of Reference Samples of Aluminum Alloys with a Low Hydrogen Concentration
- Open Access
- 5 August 2019
- Published by Ural Research Institute of Metrology (UNIIM) in Reference materials
- Vol. 15 (2)
Development of transfer measurement standards in the form of high-purity metals
- 5 August 2019
- Published by Ural Research Institute of Metrology (UNIIM) in Reference materials
- Vol. 15 (2)
Open AccessDevelopment of transfer measurement standards in the form of high-purity metals
- 1 January 2018
- Published by IOP Publishing in Metrologia
- Vol. 55 (1A) , 08018
International comparison CCQM-K116: 10 μmol mol -1 water vapour in nitrogen
The measurement of trace amounts of water in process gases is of paramount importance to a number of manufacturing processes. Water is considered to be one of the most difficult impurities to remove from gas supply systems and there is strong evidence that the presence of water contamination in semiconductor gases has a measurable impact on the quality and performance of devices. Consequently, semiconductor manufacturers are constantly reducing target levels of water in purge and process gases. As the purity of gases improves, the problem of quantifying contamination and ensuring that the gases are within specification at the point of use becomes more challenging. There are several established techniques for detecting trace water vapour in process gases. These include instruments based on the chilled mirror principle which measures the dew-point of the gas and the quartz crystal adsorption principle which measures the adsorption of water vapour into a crystal with a hygroscopic coating. Most recently, spectroscopic instruments such as those employing cavity ring-down spectroscopy (CRDS) have become available. The calibration of such instruments is a difficult exercise because of the very limited availability of accurate water vapour standards. This CCQM key comparison aims to assess the analytical capabilities of laboratories for measuring the composition of 10 μmol mol -1 water vapour in nitrogen. KEY WORDS FOR SEARCH Metrology, traceability, water vapour, process gas, advance manufacturing Main text To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/ . The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2018
- Published by IOP Publishing in Metrologia
- Vol. 55 (1A) , 08018
International comparison CCQM-K116: 10 μmol mol -1 water vapour in nitrogen
The measurement of trace amounts of water in process gases is of paramount importance to a number of manufacturing processes. Water is considered to be one of the most difficult impurities to remove from gas supply systems and there is strong evidence that the presence of water contamination in semiconductor gases has a measurable impact on the quality and performance of devices. Consequently, semiconductor manufacturers are constantly reducing target levels of water in purge and process gases. As the purity of gases improves, the problem of quantifying contamination and ensuring that the gases are within specification at the point of use becomes more challenging. There are several established techniques for detecting trace water vapour in process gases. These include instruments based on the chilled mirror principle which measures the dew-point of the gas and the quartz crystal adsorption principle which measures the adsorption of water vapour into a crystal with a hygroscopic coating. Most recently, spectroscopic instruments such as those employing cavity ring-down spectroscopy (CRDS) have become available. The calibration of such instruments is a difficult exercise because of the very limited availability of accurate water vapour standards. This CCQM key comparison aims to assess the analytical capabilities of laboratories for measuring the composition of 10 μmol mol -1 water vapour in nitrogen. KEY WORDS FOR SEARCH Metrology, traceability, water vapour, process gas, advance manufacturing Main text To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/ . The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 30 July 2016
- Published by Springer Nature in Measurement Techniques
- Vol. 59 (4) , 438-443
The Basic Principles of Metrological Assurance of Quality Control of Gas Condensate and Products Based on It
- 30 July 2016
- Published by Springer Nature in Measurement Techniques
- Vol. 59 (4) , 438-443
The Basic Principles of Metrological Assurance of Quality Control of Gas Condensate and Products Based on It
- 1 April 2016
- Published by Pleiades Publishing Ltd in Doklady Physics
- Vol. 61 (4) , 160-163
Sensitivity of the optical absorption method based on instrumental selection of Fourier components of the absorption spectrum
- 1 April 2016
- Published by Pleiades Publishing Ltd in Doklady Physics
- Vol. 61 (4) , 160-163
Sensitivity of the optical absorption method based on instrumental selection of Fourier components of the absorption spectrum