Oeslle Lucena
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Oeslle Lucena has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Rachel Sparks
King's College London, London, UK
5 shared publicationsSebastien Ourselin
King's College London, London, UK
5 shared publicationsKeyoumars Ashkan
King's College London, London, UK; King's College Hospital Foundation Trust, London, UK
4 shared publications- Sebastien Ourselin
King's College London London UK
3 shared publications Sjoerd B. Vos
Centre for Medical Image Computing, Department of Computer Sciences, University College London, London, UK; Neuroradiological Academic Unit, University College London Queen Square Institute of Neurology, University College London, London, UK
3 shared publicationsVejay Vakharia
Department of Clinical and Experimental Epilepsy, University College London, UK
3 shared publications
Latest Publications
- Open Access
MAIS: Memory-Attention for Interactive Segmentation
Interactive medical segmentation reduces annotation effort by refining predictions through user feedback. Vision Transformer (ViT)-based models, such as the Segment Anything Model (SAM), achieve state-of-the-art performance using user clicks and prior masks as prompts. However, existing methods treat interactions as independent events, leading to redundant corrections and limited refinement gains. We address this by introducing MAIS, a Memory-Attention mechanism for Interactive Segmentation that stores past user inputs and segmentation states, enabling temporal context integration. Our approach enhances ViT-based segmentation across diverse imaging modalities, achieving more efficient and accurate refinements.
Open AccessMAIS: Memory-Attention for Interactive Segmentation
Interactive medical segmentation reduces annotation effort by refining predictions through user feedback. Vision Transformer (ViT)-based models, such as the Segment Anything Model (SAM), achieve state-of-the-art performance using user clicks and prior masks as prompts. However, existing methods treat interactions as independent events, leading to redundant corrections and limited refinement gains. We address this by introducing MAIS, a Memory-Attention mechanism for Interactive Segmentation that stores past user inputs and segmentation states, enabling temporal context integration. Our approach enhances ViT-based segmentation across diverse imaging modalities, achieving more efficient and accurate refinements.
- Open Access
Dynamic AI-assisted Ipsilateral Tissue Matching for Digital Breast Tomosynthesis
Structured Purpose: To compare Digital Breast Tomosynthesis (DBT) tissue matching errors with and without artificial intelligence (AI) assistance to typical screen-detected breast tumor sizes, evaluating whether AI ameliorates lesion mislocalization beyond tumor boundaries, especially for nonexpert radiologists. The technology category is deep learning. Materials and Methods: This multicenter retrospective feasibility study conducted in April 2022 – July 2023 included 12 radiologists (mean age, 42 years ± 8) interpreting 94 lesion regions of interest in 30 women. Readers performed annotations with and without AI assistance after a minimum four-week washout period. The root mean square errors (RMSE) and maximum distance errors (MDE) were measured relative to consensus references. Stratifications included radiologist expertise ( ≥ 5 vs < 5 years), lesion abnormal-ity, and AI warnings. The Wilcoxon signed-rank test was used to assess statistical significance. Results: Across all abnormal lesions, mean RMSE was 32% higher without AI (11.70 mm vs 8.88 mm , p = .049), and mean maximum distance errors were 37.5% higher (20.68 mm vs 15.08 mm , p = .036). Non-expert radiologists showed the largest benefit: for abnormal lesions without AI warnings, RMSE was 61.9% higher without AI (12.20 mm vs 7.57 mm , p = .010) and maximum distance error was 67.5% higher (15.76 mm vs 9.47 mm , p = .028). These reductions are clinically relevant given typical screen-detected breast tumor sizes (median, 13 mm [IQR: 9–20]). Conclusion: AI-assisted tissue matching significantly reduced DBT localization errors, particularly for non-experts handling challenging cases. By keeping errors below typical tumor dimensions, AI may improve diagnostic precision and reduce risks of missed or mischaracterized lesions. Summary Statement: Dynamic artificial intelligence assisted tissue matching in digital breast tomosynthesis improves localization accuracy for non-expert radiologists, with errors in abnormal cases significantly larger (67.5%, p ≤ 0.05) without assistance. Key Points: In this multicenter retrospective study of 94 Regions of Interest (ROI) analyzed by 12 radiologists across 5 hospitals, manual tissue matching was found to have errors 32% higher in abnormal cases than AI-assisted tissue matching ( p < 0.05). For non-expert radiologists interpreting abnormal cases (excluding cases with AI warnings) without AI assistance, the root mean squared distance errors (RMSE) were found to be 61.9% higher (12.20 mm vs 7.57 mm , p < 0.01) and the maximum distance errors (MDE) was 67.6% higher (15.76 mm vs 9.47 mm , p < 0.05) than when using AI assistance. For challenging cases, many non-expert readers’ MDE without AI assistance (75th percentile: 20.21 mm ) exceeded the largest tumor dimensions (75th percentile: 20 mm ), while AI-assisted errors (75th percentile: 11.94 mm , p < 0.05) remained within median tumor sizes (12 mm ), potentially preventing correlation with non-lesion tissue.
Open AccessDynamic AI-assisted Ipsilateral Tissue Matching for Digital Breast Tomosynthesis
Structured Purpose: To compare Digital Breast Tomosynthesis (DBT) tissue matching errors with and without artificial intelligence (AI) assistance to typical screen-detected breast tumor sizes, evaluating whether AI ameliorates lesion mislocalization beyond tumor boundaries, especially for nonexpert radiologists. The technology category is deep learning. Materials and Methods: This multicenter retrospective feasibility study conducted in April 2022 – July 2023 included 12 radiologists (mean age, 42 years ± 8) interpreting 94 lesion regions of interest in 30 women. Readers performed annotations with and without AI assistance after a minimum four-week washout period. The root mean square errors (RMSE) and maximum distance errors (MDE) were measured relative to consensus references. Stratifications included radiologist expertise ( ≥ 5 vs < 5 years), lesion abnormal-ity, and AI warnings. The Wilcoxon signed-rank test was used to assess statistical significance. Results: Across all abnormal lesions, mean RMSE was 32% higher without AI (11.70 mm vs 8.88 mm , p = .049), and mean maximum distance errors were 37.5% higher (20.68 mm vs 15.08 mm , p = .036). Non-expert radiologists showed the largest benefit: for abnormal lesions without AI warnings, RMSE was 61.9% higher without AI (12.20 mm vs 7.57 mm , p = .010) and maximum distance error was 67.5% higher (15.76 mm vs 9.47 mm , p = .028). These reductions are clinically relevant given typical screen-detected breast tumor sizes (median, 13 mm [IQR: 9–20]). Conclusion: AI-assisted tissue matching significantly reduced DBT localization errors, particularly for non-experts handling challenging cases. By keeping errors below typical tumor dimensions, AI may improve diagnostic precision and reduce risks of missed or mischaracterized lesions. Summary Statement: Dynamic artificial intelligence assisted tissue matching in digital breast tomosynthesis improves localization accuracy for non-expert radiologists, with errors in abnormal cases significantly larger (67.5%, p ≤ 0.05) without assistance. Key Points: In this multicenter retrospective study of 94 Regions of Interest (ROI) analyzed by 12 radiologists across 5 hospitals, manual tissue matching was found to have errors 32% higher in abnormal cases than AI-assisted tissue matching ( p < 0.05). For non-expert radiologists interpreting abnormal cases (excluding cases with AI warnings) without AI assistance, the root mean squared distance errors (RMSE) were found to be 61.9% higher (12.20 mm vs 7.57 mm , p < 0.01) and the maximum distance errors (MDE) was 67.6% higher (15.76 mm vs 9.47 mm , p < 0.05) than when using AI assistance. For challenging cases, many non-expert readers’ MDE without AI assistance (75th percentile: 20.21 mm ) exceeded the largest tumor dimensions (75th percentile: 20 mm ), while AI-assisted errors (75th percentile: 11.94 mm , p < 0.05) remained within median tumor sizes (12 mm ), potentially preventing correlation with non-lesion tissue.
- Open Access
- 29 July 2023
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 396, 109933
Assessing informative tract segmentation and nTMS for pre-operative planning
- 29 July 2023
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 396, 109933
Open AccessAssessing informative tract segmentation and nTMS for pre-operative planning
- Open Access
- 18 May 2022
- Published by Frontiers Media SA in Frontiers in Radiology
- Vol. 2
Informative and Reliable Tract Segmentation for Preoperative Planning
Identifying white matter (WM) tracts to locate eloquent areas for preoperative surgical planning is a challenging task. Manual WM tract annotations are often used but they are time-consuming, suffer from inter- and intra-rater variability, and noise intrinsic to diffusion MRI may make manual interpretation difficult. As a result, in clinical practice direct electrical stimulation is necessary to precisely locate WM tracts during surgery. A measure of WM tract segmentation unreliability could be important to guide surgical planning and operations. In this study, we use deep learning to perform reliable tract segmentation in combination with uncertainty quantification to measure segmentation unreliability. We use a 3D U-Net to segment white matter tracts. We then estimate model and data uncertainty using test time dropout and test time augmentation, respectively. We use a volume-based calibration approach to compute representative predicted probabilities from the estimated uncertainties. In our findings, we obtain a Dice of ≈0.82 which is comparable to the state-of-the-art for multi-label segmentation and Hausdorff distance mm. We demonstrate a high positive correlation between volume variance and segmentation errors, which indicates a good measure of reliability for tract segmentation ad uncertainty estimation. Finally, we show that calibrated predicted volumes are more likely to encompass the ground truth segmentation volume than uncalibrated predicted volumes. This study is a step toward more informed and reliable WM tract segmentation for clinical decision-making.
- 18 May 2022
- Published by Frontiers Media SA in Frontiers in Radiology
- Vol. 2
Open AccessInformative and Reliable Tract Segmentation for Preoperative Planning
Identifying white matter (WM) tracts to locate eloquent areas for preoperative surgical planning is a challenging task. Manual WM tract annotations are often used but they are time-consuming, suffer from inter- and intra-rater variability, and noise intrinsic to diffusion MRI may make manual interpretation difficult. As a result, in clinical practice direct electrical stimulation is necessary to precisely locate WM tracts during surgery. A measure of WM tract segmentation unreliability could be important to guide surgical planning and operations. In this study, we use deep learning to perform reliable tract segmentation in combination with uncertainty quantification to measure segmentation unreliability. We use a 3D U-Net to segment white matter tracts. We then estimate model and data uncertainty using test time dropout and test time augmentation, respectively. We use a volume-based calibration approach to compute representative predicted probabilities from the estimated uncertainties. In our findings, we obtain a Dice of ≈0.82 which is comparable to the state-of-the-art for multi-label segmentation and Hausdorff distance mm. We demonstrate a high positive correlation between volume variance and segmentation errors, which indicates a good measure of reliability for tract segmentation ad uncertainty estimation. Finally, we show that calibrated predicted volumes are more likely to encompass the ground truth segmentation volume than uncalibrated predicted volumes. This study is a step toward more informed and reliable WM tract segmentation for clinical decision-making.
- Open Access
- 1 August 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 135, 104643
Enhancing the estimation of fiber orientation distributions using convolutional neural networks
- 1 August 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 135, 104643
Open AccessEnhancing the estimation of fiber orientation distributions using convolutional neural networks
- Open Access
Enhancing Fiber Orientation Distributions using convolutional Neural Networks
Accurate local fiber orientation distribution (FOD) modeling based on diffusion magnetic resonance imaging (dMRI) capable of resolving complex fiber configurations benefits from specific acquisition protocols that sample a high number of gradient directions (b-vecs), a high maximum b-value(b-vals), and multiple b-values (multi-shell). However, acquisition time is limited in a clinical setting and commercial scanners may not provide such dMRI sequences. Therefore, dMRI is often acquired as single-shell (single b-value). In this work, we learn improved FODs for commercially acquired MRI. We evaluate patch-based 3D convolutional neural networks (CNNs)on their ability to regress multi-shell FOD representations from single-shell representations, where the representation is a spherical harmonics obtained from constrained spherical deconvolution (CSD) to model FODs. We evaluate U-Net and HighResNet 3D CNN architectures on data from the Human Connectome Project and an in-house dataset. We evaluate how well each CNN model can resolve local fiber orientation 1) when training and testing on datasets with the same dMRI acquisition protocol; 2) when testing on a dataset with a different dMRI acquisition protocol than used to train the CNN models; and 3) when testing on a dataset with a fewer number of gradient directions than used to train the CNN models. Our approach may enable robust CSD model estimation on single-shell dMRI acquisition protocols with few gradient directions, reducing acquisition times, facilitating translation of improved FOD estimation to time-limited clinical environments.
Open AccessEnhancing Fiber Orientation Distributions using convolutional Neural Networks
Accurate local fiber orientation distribution (FOD) modeling based on diffusion magnetic resonance imaging (dMRI) capable of resolving complex fiber configurations benefits from specific acquisition protocols that sample a high number of gradient directions (b-vecs), a high maximum b-value(b-vals), and multiple b-values (multi-shell). However, acquisition time is limited in a clinical setting and commercial scanners may not provide such dMRI sequences. Therefore, dMRI is often acquired as single-shell (single b-value). In this work, we learn improved FODs for commercially acquired MRI. We evaluate patch-based 3D convolutional neural networks (CNNs)on their ability to regress multi-shell FOD representations from single-shell representations, where the representation is a spherical harmonics obtained from constrained spherical deconvolution (CSD) to model FODs. We evaluate U-Net and HighResNet 3D CNN architectures on data from the Human Connectome Project and an in-house dataset. We evaluate how well each CNN model can resolve local fiber orientation 1) when training and testing on datasets with the same dMRI acquisition protocol; 2) when testing on a dataset with a different dMRI acquisition protocol than used to train the CNN models; and 3) when testing on a dataset with a fewer number of gradient directions than used to train the CNN models. Our approach may enable robust CSD model estimation on single-shell dMRI acquisition protocols with few gradient directions, reducing acquisition times, facilitating translation of improved FOD estimation to time-limited clinical environments.
- 7 November 2020
- Published by Springer Nature
- p. 101-112
Convolutional Neural Networks for Fiber Orientation Distribution Enhancement to Improve Single-Shell Diffusion MRI Tractography
- 7 November 2020
- Published by Springer Nature
- p. 101-112
Convolutional Neural Networks for Fiber Orientation Distribution Enhancement to Improve Single-Shell Diffusion MRI Tractography
- 1 July 2019
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 98, 48-58
Convolutional neural networks for skull-stripping in brain MR imaging using silver standard masks
- 1 July 2019
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 98, 48-58
Convolutional neural networks for skull-stripping in brain MR imaging using silver standard masks
- 13 September 2018
- Published by Springer Nature
- p. 238-246
A Machine Learning Approach to Predict Instrument Bending in Stereotactic Neurosurgery
- 13 September 2018
- Published by Springer Nature
- p. 238-246
A Machine Learning Approach to Predict Instrument Bending in Stereotactic Neurosurgery