Wataru Hijikata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Wataru Hijikata has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
Tadahiko Shinshi
Laboratory for Future Interdisciplinary Research of Science and Technology, Tokyo Institute of Technology, Yokohama, JAPAN
12 shared publications- Tadahiko Shinshi
Tokyo Institute of Technology
8 shared publications Akira Shimokohbe
Precision and Intelligence Laboratory
7 shared publicationsSetsuo Takatani
Division of Research and Development, MedTech Heart Inc., Tokyo, Japan
6 shared publications- Tatsuki Fujiwara
Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University , Tokyo, Japan
6 shared publications Hirokuni Arai
Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences Tokyo Medical and Dental University Tokyo Japan
5 shared publications
Latest Publications
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Self-Powered Artificial Skin with Contact Position Detection Using Electret
The development of flexible electronic artificial skin with contact-sensing capabilities is advancing in the robotics and medical fields. When detecting contact positions, using a sensor array that integrates many tactile sensors causes the number of wires to increase dramatically as the resolution and sensor area improve. In this study, we propose an artificial skin that requires no power supply to the sensor by using an electret, and that enables contact-position detection with reduced wiring by employing high-resistance electrodes. The sensor has a simple structure in which an electret and a dielectric elastomer are laminated between top and bottom electrodes. By connecting load resistors to the four corners of the sensor and measuring the voltage drops across these resistors, the contact position is estimated. The fabricated sensor achieved contact-position detection with a standard deviation of approximately 3 mm for a 50 mm × 50 mm sensor area using only five wires in total—four corner electrodes plus ground.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Self-Powered Artificial Skin with Contact Position Detection Using Electret
The development of flexible electronic artificial skin with contact-sensing capabilities is advancing in the robotics and medical fields. When detecting contact positions, using a sensor array that integrates many tactile sensors causes the number of wires to increase dramatically as the resolution and sensor area improve. In this study, we propose an artificial skin that requires no power supply to the sensor by using an electret, and that enables contact-position detection with reduced wiring by employing high-resistance electrodes. The sensor has a simple structure in which an electret and a dielectric elastomer are laminated between top and bottom electrodes. By connecting load resistors to the four corners of the sensor and measuring the voltage drops across these resistors, the contact position is estimated. The fabricated sensor achieved contact-position detection with a standard deviation of approximately 3 mm for a 50 mm × 50 mm sensor area using only five wires in total—four corner electrodes plus ground.
- Open Access
- 27 June 2025
- Published by Wiley in Artificial Organs
- Vol. 49 (11) , 1652-1659
New Findings on Pulsatile ECMO : Verification of the Potential to Improve Antithrombogenicity of a Membrane Oxygenator Using Pump‐Generated Pulsatile Flow in an Innovative Animal Model
Background: Extracorporeal membrane oxygenation (ECMO) provides mechanical circulatory and respiratory support. However, thrombus formation in the circuit can lead to hemorrhagic complications, requiring improvements in ECMO anti‐thrombogenicity. Few studies have reported the effect of pulsatile flow on thrombus formation in ECMO circuits. This study evaluated how pulsatile flow affects thrombus formation inside the membrane oxygenator. Methods: This study was conducted in pigs ( n = 5) using an experimental model in which each pig was connected to two different ECMO circuits: one with steady flow (via the jugular vein and carotid artery) and the other with pulsatile flow (via the femoral vein and artery). The pulsatile waveform was generated as an upward sinusoidal waveform added to the baseline frequency. Both circuits were set to a mean flow rate of 2 L/min and operated for 4 h without anticoagulation. Thrombus formation in the membrane oxygenators was observed during and after circulation. The thrombus area was quantified using image analysis. Results: All experiments were completed with stable hemodynamics. The pressure in the pulsatile circuit was confirmed to be a pulsatile waveform. The thrombus area in the steady flow circuits was 81.5%, 10.6%, 42.1%, 60.2%, and 96.7%, while those in the pulsatile flow circuits were 6.2%, 5.2%, 8.4%, 9.9%, and 65.8%, respectively. The thrombus area in the pulsatile flow circuit tended to be smaller than that in the steady flow circuit. Conclusions: Pulsatile flow with a specific waveform may reduce thrombus formation in membrane oxygenators, potentially enhancing the anti‐thrombogenicity of ECMO circuits.
- 27 June 2025
- Published by Wiley in Artificial Organs
- Vol. 49 (11) , 1652-1659
Open AccessNew Findings on Pulsatile ECMO : Verification of the Potential to Improve Antithrombogenicity of a Membrane Oxygenator Using Pump‐Generated Pulsatile Flow in an Innovative Animal Model
Background: Extracorporeal membrane oxygenation (ECMO) provides mechanical circulatory and respiratory support. However, thrombus formation in the circuit can lead to hemorrhagic complications, requiring improvements in ECMO anti‐thrombogenicity. Few studies have reported the effect of pulsatile flow on thrombus formation in ECMO circuits. This study evaluated how pulsatile flow affects thrombus formation inside the membrane oxygenator. Methods: This study was conducted in pigs ( n = 5) using an experimental model in which each pig was connected to two different ECMO circuits: one with steady flow (via the jugular vein and carotid artery) and the other with pulsatile flow (via the femoral vein and artery). The pulsatile waveform was generated as an upward sinusoidal waveform added to the baseline frequency. Both circuits were set to a mean flow rate of 2 L/min and operated for 4 h without anticoagulation. Thrombus formation in the membrane oxygenators was observed during and after circulation. The thrombus area was quantified using image analysis. Results: All experiments were completed with stable hemodynamics. The pressure in the pulsatile circuit was confirmed to be a pulsatile waveform. The thrombus area in the steady flow circuits was 81.5%, 10.6%, 42.1%, 60.2%, and 96.7%, while those in the pulsatile flow circuits were 6.2%, 5.2%, 8.4%, 9.9%, and 65.8%, respectively. The thrombus area in the pulsatile flow circuit tended to be smaller than that in the steady flow circuit. Conclusions: Pulsatile flow with a specific waveform may reduce thrombus formation in membrane oxygenators, potentially enhancing the anti‐thrombogenicity of ECMO circuits.
- Open Access
- 21 February 2025
- Published by Elsevier in Measurement
- Vol. 249
Self-powered mouthguard-type bite force sensor with wide dynamic range
- 21 February 2025
- Published by Elsevier in Measurement
- Vol. 249
Open AccessSelf-powered mouthguard-type bite force sensor with wide dynamic range
- Open Access
- 1 January 2025
- Published by Japan Society of Applied Electromagnetics and Mechanics in Journal of the Japan Society of Applied Electromagnetics and Mechanics
- Vol. 33 (3) , 217-222
Basic Experiments of a Maglev Shear Load Device for Evaluating the Resistance of Hemostatic Factors to Degradation by Shear Stress
In patients with continuous flow ventricular assist devices, bleeding complications frequently occur due to the enzymatic degradation of von Willebrand Factor (vWF) large multimers. This degradation is caused by high shear stress from the device's high-speed rotating components. Although a double-cylinder-type shear load device has been proposed for the preliminary quantitative evaluation of vWF large multimers, it has not provided sufficient evaluation due to issues with the open-type shear portion and the contact-type mechanical bearings. These issues arise from air bubbles in the blood samples and unstable motor rotation. In this study, we propose a new shear loading device that features a closed-type shear portion and uses magnetic bearings to levitate the inner cylinder and rotate the outer cylinder. We experimentally evaluated that the levitation of the inner cylinder was controlled by two magnetic bearings (upper and lower), and the stability of the levitation.
- 1 January 2025
- Published by Japan Society of Applied Electromagnetics and Mechanics in Journal of the Japan Society of Applied Electromagnetics and Mechanics
- Vol. 33 (3) , 217-222
Open AccessBasic Experiments of a Maglev Shear Load Device for Evaluating the Resistance of Hemostatic Factors to Degradation by Shear Stress
In patients with continuous flow ventricular assist devices, bleeding complications frequently occur due to the enzymatic degradation of von Willebrand Factor (vWF) large multimers. This degradation is caused by high shear stress from the device's high-speed rotating components. Although a double-cylinder-type shear load device has been proposed for the preliminary quantitative evaluation of vWF large multimers, it has not provided sufficient evaluation due to issues with the open-type shear portion and the contact-type mechanical bearings. These issues arise from air bubbles in the blood samples and unstable motor rotation. In this study, we propose a new shear loading device that features a closed-type shear portion and uses magnetic bearings to levitate the inner cylinder and rotate the outer cylinder. We experimentally evaluated that the levitation of the inner cylinder was controlled by two magnetic bearings (upper and lower), and the stability of the levitation.
- Open Access
- 1 January 2025
- Published by Japan Society of Applied Electromagnetics and Mechanics in Journal of the Japan Society of Applied Electromagnetics and Mechanics
- Vol. 33 (3) , 243-248
Development of a Stretchable Electrical Skin with a Contact Function Utilizing Electret
Because of sensory neuropathy in the sole of the diabetic foot, it is difficult to notice injuries such as being hit by a nail or a pebble. Co-occurrence of wounds leads to foot ulcers and gangrene, and when the sole becomes gangrenous, the lower limb must be amputated. To avoid the occurrence of foot ulcers, one solution is to support sensory functions by covering the entire sole with electrical skin that has tactile functions. This study proposes a self-powered stretchable electrical skin (eee-skin) with tactile function. The results of contact detection experiments confirmed that the output voltage increases with increasing elongation rate, and a maximum output voltage of approximately 0.6 V was obtained at an elongation rate of 10% and a contact of approximately 0.5 N.
- 1 January 2025
- Published by Japan Society of Applied Electromagnetics and Mechanics in Journal of the Japan Society of Applied Electromagnetics and Mechanics
- Vol. 33 (3) , 243-248
Open AccessDevelopment of a Stretchable Electrical Skin with a Contact Function Utilizing Electret
Because of sensory neuropathy in the sole of the diabetic foot, it is difficult to notice injuries such as being hit by a nail or a pebble. Co-occurrence of wounds leads to foot ulcers and gangrene, and when the sole becomes gangrenous, the lower limb must be amputated. To avoid the occurrence of foot ulcers, one solution is to support sensory functions by covering the entire sole with electrical skin that has tactile functions. This study proposes a self-powered stretchable electrical skin (eee-skin) with tactile function. The results of contact detection experiments confirmed that the output voltage increases with increasing elongation rate, and a maximum output voltage of approximately 0.6 V was obtained at an elongation rate of 10% and a contact of approximately 0.5 N.
- Open Access
- 1 January 2025
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 20 (2) , 24-00254
Model-based design of a muscle mass for a biohybrid actuator
Among soft actuators, biohybrid actuators constructed by the integration of living tissue and flexible materials, show superior properties of intrinsic softness, environmental compatibility, self-repair function over traditional actuators with rigid body. Skeletal muscles, one of the most frequently used biohybrid actuators, are considered ideal options for driving sources. Research on biohybrid actuators has focused on fabricating actuator entities by tissue-culturing or three-dimensional printing and assembling them. These techniques are well-developed. However, they lack the model-based design approach found in existing actuators that achieve specific performances. A muscle contraction model applicable to skeletal muscle actuators has been developed to model the response of skeletal muscle contraction to external electrical stimuli and has been shown to be reproducible. Therefore, we used this model as a basis to establish the design approach of the biohybrid actuator. The performance requirements for the skeletal muscle actuator depend specifically on the target application and size. As the first step in the design process, we set the muscle mass as a design parameter and the contractile force as a design specification, and then used the model to establish a design method that achieves the required contractile force for a muscle mass. The contractile forces of toad gastrocnemius muscles with different masses were used in the experiments to determine the parameters of the model, specifically those related to muscle mass, thus completing the design model. Subsequently, the muscle mass obtained by targeting the actual contractile force was compared with the actual muscle mass in a verification test, and the results confirmed the feasibility of the designed model. This is the first study that attempts to establish a biohybrid actuator design method, which could lead to significant development in this field.
- 1 January 2025
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 20 (2) , 24-00254
Open AccessModel-based design of a muscle mass for a biohybrid actuator
Among soft actuators, biohybrid actuators constructed by the integration of living tissue and flexible materials, show superior properties of intrinsic softness, environmental compatibility, self-repair function over traditional actuators with rigid body. Skeletal muscles, one of the most frequently used biohybrid actuators, are considered ideal options for driving sources. Research on biohybrid actuators has focused on fabricating actuator entities by tissue-culturing or three-dimensional printing and assembling them. These techniques are well-developed. However, they lack the model-based design approach found in existing actuators that achieve specific performances. A muscle contraction model applicable to skeletal muscle actuators has been developed to model the response of skeletal muscle contraction to external electrical stimuli and has been shown to be reproducible. Therefore, we used this model as a basis to establish the design approach of the biohybrid actuator. The performance requirements for the skeletal muscle actuator depend specifically on the target application and size. As the first step in the design process, we set the muscle mass as a design parameter and the contractile force as a design specification, and then used the model to establish a design method that achieves the required contractile force for a muscle mass. The contractile forces of toad gastrocnemius muscles with different masses were used in the experiments to determine the parameters of the model, specifically those related to muscle mass, thus completing the design model. Subsequently, the muscle mass obtained by targeting the actual contractile force was compared with the actual muscle mass in a verification test, and the results confirmed the feasibility of the designed model. This is the first study that attempts to establish a biohybrid actuator design method, which could lead to significant development in this field.
- 4 January 2024
- Published by Springer Nature
- p. 399-420
Energy Harvesting from Bite Force Using Electret Sheet
- 4 January 2024
- Published by Springer Nature
- p. 399-420
Energy Harvesting from Bite Force Using Electret Sheet
- Open Access
- 1 January 2024
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 19 (3) , 24-00017
Model-based control of skeletal muscle using muscle-contraction models
Bioactuators using skeletal muscle are expected to be applied to medical and welfare equipment as functional materials with self-growth functions. In this regard, their contraction force must be controlled with high accuracy for the desired operation. Therefore, in this study, a model-based control method that follows the contraction force against an arbitrary reference contraction force is proposed to control the contraction of skeletal muscle. The muscle-contraction mechanism is modeled, and the stimulating voltage for exerting the desired contraction force is obtained using this model. Furthermore, the proposed method is validated experimentally using the gastrocnemius muscle of a toad. In the experiment, we identify muscle-contraction model parameters that can reproduce the contraction-force response of the gastrocnemius muscle from experimental data. Using the model, the stimulating voltage for exerting a reference is calculated. The voltage is applied to the gastrocnemius muscle of a toad to control the contraction force. The experimental results show that the proposed model-based control method can control muscle contractions even under a complicated reference contraction force.
- 1 January 2024
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 19 (3) , 24-00017
Open AccessModel-based control of skeletal muscle using muscle-contraction models
Bioactuators using skeletal muscle are expected to be applied to medical and welfare equipment as functional materials with self-growth functions. In this regard, their contraction force must be controlled with high accuracy for the desired operation. Therefore, in this study, a model-based control method that follows the contraction force against an arbitrary reference contraction force is proposed to control the contraction of skeletal muscle. The muscle-contraction mechanism is modeled, and the stimulating voltage for exerting the desired contraction force is obtained using this model. Furthermore, the proposed method is validated experimentally using the gastrocnemius muscle of a toad. In the experiment, we identify muscle-contraction model parameters that can reproduce the contraction-force response of the gastrocnemius muscle from experimental data. Using the model, the stimulating voltage for exerting a reference is calculated. The voltage is applied to the gastrocnemius muscle of a toad to control the contraction force. The experimental results show that the proposed model-based control method can control muscle contractions even under a complicated reference contraction force.
- Open Access
- 1 January 2024
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 19 (3) , 23-00590
Development of implantable energy-harvesting system utilizing incomplete tetanus of skeletal muscle
Herein, an implantable energy-harvesting system utilizing the contraction of electrically stimulated skeletal muscle is proposed for self-sustainable batteries of implantable medical devices (IMDs) and health-monitoring devices. To achieve high energy conversion efficiency, a resonance generator utilizing the vibration of the skeletal muscle, called as incomplete tetanus, is proposed. Considering the multi-dynamics of muscle contraction, oscillator, and electrostatic induction, design parameters, such as the stimulation condition of the muscle and the mechanical characteristics of the resonance generator, are optimized. In the benchtop experiment, the power generated by the prototype is 20.48 μW. Moreover, a positive net power of 13.1 μW is generated in the ex vivo experiments using the skeletal muscles of toads; this power is sufficient to operate IMDs, thus demonstrating the feasibility of the proposed energy harvesting system using incomplete tetanus of the skeletal muscle.
- 1 January 2024
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 19 (3) , 23-00590
Open AccessDevelopment of implantable energy-harvesting system utilizing incomplete tetanus of skeletal muscle
Herein, an implantable energy-harvesting system utilizing the contraction of electrically stimulated skeletal muscle is proposed for self-sustainable batteries of implantable medical devices (IMDs) and health-monitoring devices. To achieve high energy conversion efficiency, a resonance generator utilizing the vibration of the skeletal muscle, called as incomplete tetanus, is proposed. Considering the multi-dynamics of muscle contraction, oscillator, and electrostatic induction, design parameters, such as the stimulation condition of the muscle and the mechanical characteristics of the resonance generator, are optimized. In the benchtop experiment, the power generated by the prototype is 20.48 μW. Moreover, a positive net power of 13.1 μW is generated in the ex vivo experiments using the skeletal muscles of toads; this power is sufficient to operate IMDs, thus demonstrating the feasibility of the proposed energy harvesting system using incomplete tetanus of the skeletal muscle.
- Open Access
- 28 December 2023
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 27 (3) , 212-221
Spiral groove bearing design for improving plasma skimming in rotary blood pumps
High-efficiency plasma skimming is hopeful to prevent hemolysis inside spiral groove bearings (SGBs) because it can exclude red blood cells from the ridge gap with a high shear force. However, no study reveals the shape design of SGBs to improve plasma skimming. Therefore, this study proposed and applied a groove design strategy to designing an optimal SGB for enhancing plasma skimming in a rotary blood pump (RBP). Initially, we proposed the design strategy that the shape of the groove for enhancing plasma skimming corresponds to the direction of blood flow in the ridge gap. Second, we visualized the cell flow in a specially designed experimental RBP to determine the direction of blood flow, which was helpful in the subsequent SGB design. Then, we created an SGB to provide superior plasma skimming and applied it to the experimental RBP. We evaluated the plasma skimming effect of SGB at rotational speeds ranging from 2400 to 3000 rpm and hematocrit conditions between 1% and 40%. At a 1% hematocrit, the plasma skimming efficiency for the entire SGB was greater than 95%. In all hematocrit conditions, the efficiency at the inner ridges of the SGB was greater than 80%. The results showed the designed SGB successfully induced excellent plasma skimming within ridge gaps. This study is the first to propose and apply a shape design strategy to generate excellent plasma skimming within an SGB. This study may contribute to the prevention of SGB hemolysis inside SGB for use in RBPs.
- 28 December 2023
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 27 (3) , 212-221
Open AccessSpiral groove bearing design for improving plasma skimming in rotary blood pumps
High-efficiency plasma skimming is hopeful to prevent hemolysis inside spiral groove bearings (SGBs) because it can exclude red blood cells from the ridge gap with a high shear force. However, no study reveals the shape design of SGBs to improve plasma skimming. Therefore, this study proposed and applied a groove design strategy to designing an optimal SGB for enhancing plasma skimming in a rotary blood pump (RBP). Initially, we proposed the design strategy that the shape of the groove for enhancing plasma skimming corresponds to the direction of blood flow in the ridge gap. Second, we visualized the cell flow in a specially designed experimental RBP to determine the direction of blood flow, which was helpful in the subsequent SGB design. Then, we created an SGB to provide superior plasma skimming and applied it to the experimental RBP. We evaluated the plasma skimming effect of SGB at rotational speeds ranging from 2400 to 3000 rpm and hematocrit conditions between 1% and 40%. At a 1% hematocrit, the plasma skimming efficiency for the entire SGB was greater than 95%. In all hematocrit conditions, the efficiency at the inner ridges of the SGB was greater than 80%. The results showed the designed SGB successfully induced excellent plasma skimming within ridge gaps. This study is the first to propose and apply a shape design strategy to generate excellent plasma skimming within an SGB. This study may contribute to the prevention of SGB hemolysis inside SGB for use in RBPs.