Marco Riva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marco Riva has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Basilio Esposito
ENEA, Nuclear Department, C. R. Frascati, Via E. Fermi 45, I-00044 Frascati, Roma, Italy
8 shared publications - Daniele Marocco
ENEA C. R. Frascati 2 , via E. Fermi 45, 00044 Frascati
4 shared publications - Ana Fernandes
Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal
3 shared publications - Bruno Santos
Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal
3 shared publications D. Marocco
Dipartimento FSN, ENEA C. R. Frascati, Frascati, Italy
3 shared publications- Francesco Belli
Nuclear Department, ENEA C.R. Frascati, Frascati, Italy
3 shared publications
Latest Publications
- Open Access
- 1 June 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (6)
Estimating the neutron yield in a deuterium–tritium plasma with the JET neutron camera
The JET neutron camera is used to monitor a 2D profile of the neutron emission from the plasma, using 19 sightlines with plastic scintillators suited for measuring neutrons from the D + T → n + 4He (DT) reaction. This paper describes an independent, first-principles physics method for estimating the volume integrated DT neutron yield with the neutron camera. This is performed for a selection of shots from the two recent DT campaigns at JET, the DTE2 and DTE3 JET campaigns. It covers the data reduction methods from a light yield calibration of the scintillators to treatment of pile-up, which is prevalent during high yield DT experiments. Several models of the camera geometry are used to account for scattering and transmission effects in the neutron transport. The neutron yield is estimated using models of the neutron emission profile, which are fitted to measurement data. The neutron yield estimates from this method are compared to corresponding estimates from the JET fission chambers. Our estimates with the neutron camera are on average 34% and 41% higher than the fission chamber estimates for DTE2 and DTE3, respectively. The reasons for the discrepancies between the two systems are presently unknown and prompt further investigation. In this paper, we detail the methods used to reach the neutron yield estimate from the neutron camera, along with their strengths, weaknesses, and potential points of failure. This method is an evolution of an earlier work that estimated the deuterium–deuterium neutron yield using similar methods.
- 1 June 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (6)
Open AccessEstimating the neutron yield in a deuterium–tritium plasma with the JET neutron camera
The JET neutron camera is used to monitor a 2D profile of the neutron emission from the plasma, using 19 sightlines with plastic scintillators suited for measuring neutrons from the D + T → n + 4He (DT) reaction. This paper describes an independent, first-principles physics method for estimating the volume integrated DT neutron yield with the neutron camera. This is performed for a selection of shots from the two recent DT campaigns at JET, the DTE2 and DTE3 JET campaigns. It covers the data reduction methods from a light yield calibration of the scintillators to treatment of pile-up, which is prevalent during high yield DT experiments. Several models of the camera geometry are used to account for scattering and transmission effects in the neutron transport. The neutron yield is estimated using models of the neutron emission profile, which are fitted to measurement data. The neutron yield estimates from this method are compared to corresponding estimates from the JET fission chambers. Our estimates with the neutron camera are on average 34% and 41% higher than the fission chamber estimates for DTE2 and DTE3, respectively. The reasons for the discrepancies between the two systems are presently unknown and prompt further investigation. In this paper, we detail the methods used to reach the neutron yield estimate from the neutron camera, along with their strengths, weaknesses, and potential points of failure. This method is an evolution of an earlier work that estimated the deuterium–deuterium neutron yield using similar methods.
- Open Access
- 1 July 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (7)
Estimating the neutron yield in a deuterium plasma with the JET neutron camera
The JET neutron camera is a well-established detector system at JET, which has 19 sightlines each equipped with a liquid scintillator. The system measures a 2D profile of the neutron emission from the plasma. A first principle physics method is used to estimate the DD neutron yield that is based on JET neutron camera measurements and is independent of other neutron measurements. This paper details the data reduction techniques, models of the neutron camera, simulations of neutron transport, and detector responses used to this end. The estimate uses a simple parameterized model of the neutron emission profile. The method makes use of the JET neutron camera’s upgraded data acquisition system. It also accounts for neutron scattering near the detectors and transmission through the collimator. These components together contribute to 9% of the detected neutron rate above a 0.5 MeVee energy threshold. Despite the simplicity of the neutron emission profile model, the DD neutron yield estimate falls on average within 10% agreement with a corresponding estimate from the JET fission chambers. The method can be improved by considering more advanced neutron emission profiles. It can also be expanded to estimate the DT neutron yield with the same methodology.
- 1 July 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (7)
Open AccessEstimating the neutron yield in a deuterium plasma with the JET neutron camera
The JET neutron camera is a well-established detector system at JET, which has 19 sightlines each equipped with a liquid scintillator. The system measures a 2D profile of the neutron emission from the plasma. A first principle physics method is used to estimate the DD neutron yield that is based on JET neutron camera measurements and is independent of other neutron measurements. This paper details the data reduction techniques, models of the neutron camera, simulations of neutron transport, and detector responses used to this end. The estimate uses a simple parameterized model of the neutron emission profile. The method makes use of the JET neutron camera’s upgraded data acquisition system. It also accounts for neutron scattering near the detectors and transmission through the collimator. These components together contribute to 9% of the detected neutron rate above a 0.5 MeVee energy threshold. Despite the simplicity of the neutron emission profile model, the DD neutron yield estimate falls on average within 10% agreement with a corresponding estimate from the JET fission chambers. The method can be improved by considering more advanced neutron emission profiles. It can also be expanded to estimate the DT neutron yield with the same methodology.
- 18 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (8) , 2173-2178
Real-Time Implementation of the Neutron/Gamma Discrimination in an FPGA-Based DAQ MTCA Platform Using a Convolutional Neural Network
These days, research on the classification of neutron/gamma waveforms in scintillators using pulse shape discrimination (PSD) techniques is a highly studied topic. Numerous methods have been explored to optimize this classification, with some of the most recent research being focused on machine learning techniques with excellent results. These approaches are mainly based on the use of 1-D convolutional neural networks (CNNs). In this field, field-programmable gate arrays (FPGAs) with high-sampling rate analog to digital converters (ADCs) have been used to perform this classification in real-time. In this work, we select a potential architecture and implement it with the help of the IntelFPGA OpenCL SDK environment. A shorter and C-like development of OpenCL enables a more straightforward modification and optimization of the network architecture. The main goal of this work is the evaluation of the needed resources and the obtained performance to prototype a complete solution in the FPGA. The FPGA design is generated as if it was connected to an ADC module streaming the data samples with the help of a Board Support Package developed for an IntelFPGA ARRIA10 available in an Advanced Mezzanine Card (AMC) module in an Micro Telecommunications Computing Architecture (MTCA.4) platform. The prototyped solution has been integrated into Experimental Physics and Industrial Control System (EPICS) using the nominal device support (NDS) model currently being developed by ITER.
- 18 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (8) , 2173-2178
Real-Time Implementation of the Neutron/Gamma Discrimination in an FPGA-Based DAQ MTCA Platform Using a Convolutional Neural Network
These days, research on the classification of neutron/gamma waveforms in scintillators using pulse shape discrimination (PSD) techniques is a highly studied topic. Numerous methods have been explored to optimize this classification, with some of the most recent research being focused on machine learning techniques with excellent results. These approaches are mainly based on the use of 1-D convolutional neural networks (CNNs). In this field, field-programmable gate arrays (FPGAs) with high-sampling rate analog to digital converters (ADCs) have been used to perform this classification in real-time. In this work, we select a potential architecture and implement it with the help of the IntelFPGA OpenCL SDK environment. A shorter and C-like development of OpenCL enables a more straightforward modification and optimization of the network architecture. The main goal of this work is the evaluation of the needed resources and the obtained performance to prototype a complete solution in the FPGA. The FPGA design is generated as if it was connected to an ADC module streaming the data samples with the help of a Board Support Package developed for an IntelFPGA ARRIA10 available in an Advanced Mezzanine Card (AMC) module in an Micro Telecommunications Computing Architecture (MTCA.4) platform. The prototyped solution has been integrated into Experimental Physics and Industrial Control System (EPICS) using the nominal device support (NDS) model currently being developed by ITER.
- 22 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (7) , 1310-1317
The Design and Performance of the Real-Time Software Architecture for the ITER Radial Neutron Camera
The neutron detection system for characterization of emissivity in ITER Tokamak during DD and DT experiments poses serious challenges to the performance of the diagnostic control and data acquisition system (CDAcq). The ongoing design of the ITER radial neutron camera (RNC) diagnostic is composed by 26 lines of sight (LOS) for complete plasma inspection. The CDAcq system aims at meeting the ITER requirements of delivering the measurement of the real-time neutron emissivity profile with time resolution and control cycle time of 10 ms at peak event rate of 2 MEvents/s per LOS. This measurement demands the generation of the neutron spectra for each LOS with neutron/gamma discrimination and pile-up rejection. The neutron spectra can be totally processed in the host CPU or it can use the processed data coming from the system field-programmable gate array (FPGA). The number of neutron counts extracted from the spectra is then used to calculate the neutron emissivity profile using an inversion algorithm. Moreover, it is required that the event-based raw data acquired are made available to the ITER data network without local data storage for postprocessing. The data production for the 2 MEvents/s rate can go up to a maximum data throughput of 0.5 GB/s per channel, fostering the evaluation of real-time data compression techniques in RNC. To meet the demands of the project, a CDAcq prototype has been used to design and test a high-performance distributed software architecture taking advantage of multicore CPU technology capable of coping with the requirements. This submission depicts the design of the real-time architecture, the spectra algorithms (pulse height analysis, neutron/gamma discrimination, and pile-up correction), and the inversion algorithm to calculate the emissivity profile. Preliminary tests to evaluate the systems performance with the synthetic data are presented.
- 22 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (7) , 1310-1317
The Design and Performance of the Real-Time Software Architecture for the ITER Radial Neutron Camera
The neutron detection system for characterization of emissivity in ITER Tokamak during DD and DT experiments poses serious challenges to the performance of the diagnostic control and data acquisition system (CDAcq). The ongoing design of the ITER radial neutron camera (RNC) diagnostic is composed by 26 lines of sight (LOS) for complete plasma inspection. The CDAcq system aims at meeting the ITER requirements of delivering the measurement of the real-time neutron emissivity profile with time resolution and control cycle time of 10 ms at peak event rate of 2 MEvents/s per LOS. This measurement demands the generation of the neutron spectra for each LOS with neutron/gamma discrimination and pile-up rejection. The neutron spectra can be totally processed in the host CPU or it can use the processed data coming from the system field-programmable gate array (FPGA). The number of neutron counts extracted from the spectra is then used to calculate the neutron emissivity profile using an inversion algorithm. Moreover, it is required that the event-based raw data acquired are made available to the ITER data network without local data storage for postprocessing. The data production for the 2 MEvents/s rate can go up to a maximum data throughput of 0.5 GB/s per channel, fostering the evaluation of real-time data compression techniques in RNC. To meet the demands of the project, a CDAcq prototype has been used to design and test a high-performance distributed software architecture taking advantage of multicore CPU technology capable of coping with the requirements. This submission depicts the design of the real-time architecture, the spectra algorithms (pulse height analysis, neutron/gamma discrimination, and pile-up correction), and the inversion algorithm to calculate the emissivity profile. Preliminary tests to evaluate the systems performance with the synthetic data are presented.
- 7 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (7) , 1318-1323
FPGA Code for the Data Acquisition and Real-Time Processing Prototype of the ITER Radial Neutron Camera
The main role of the ITER Radial Neutron Camera (RNC) diagnostic is to measure in real-time the plasma neutron emissivity profile at high peak count rates for a time duration up to 500 s. Due to the unprecedented high performance conditions and after the identification of critical problems, a set of activities have been selected, focused on the development of high priority prototypes, capable to deliver answers to those problems before the final RNC design. This paper presents one of the selected activities: the design, development and testing of a dedicated FPGA code for the RNC Data Acquisition prototype. The FPGA code aims to acquire, process and store in real-time the neutron and gamma pulses from the detectors located in collimated lines of sight viewing a poloidal plasma section from the ITER Equatorial Port Plug 1. The hardware platform used was an evaluation board from Xilinx (KC705) carrying an IPFN FPGA Mezzanine Card (FMC-AD2-1600) with 2 digitizer channels of 12-bit resolution sampling up to 1.6 Gsamples/s. The code performs the proper input signal conditioning using a down-sampled configuration to 400 Msamples/s, apply dedicated algorithms for pulse detection, filtering and pile up detection, and includes two distinct data paths operating simultaneously: i) the event-based data-path for pulse storage; and ii) the real-time processing, with dedicated algorithms for pulse shape discrimination and pulse height spectra. For continuous data throughput both data-paths are streamed to the host through two distinct PCIe x8 Direct Memory Access (DMA) channels.
- 7 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (7) , 1318-1323
FPGA Code for the Data Acquisition and Real-Time Processing Prototype of the ITER Radial Neutron Camera
The main role of the ITER Radial Neutron Camera (RNC) diagnostic is to measure in real-time the plasma neutron emissivity profile at high peak count rates for a time duration up to 500 s. Due to the unprecedented high performance conditions and after the identification of critical problems, a set of activities have been selected, focused on the development of high priority prototypes, capable to deliver answers to those problems before the final RNC design. This paper presents one of the selected activities: the design, development and testing of a dedicated FPGA code for the RNC Data Acquisition prototype. The FPGA code aims to acquire, process and store in real-time the neutron and gamma pulses from the detectors located in collimated lines of sight viewing a poloidal plasma section from the ITER Equatorial Port Plug 1. The hardware platform used was an evaluation board from Xilinx (KC705) carrying an IPFN FPGA Mezzanine Card (FMC-AD2-1600) with 2 digitizer channels of 12-bit resolution sampling up to 1.6 Gsamples/s. The code performs the proper input signal conditioning using a down-sampled configuration to 400 Msamples/s, apply dedicated algorithms for pulse detection, filtering and pile up detection, and includes two distinct data paths operating simultaneously: i) the event-based data-path for pulse storage; and ii) the real-time processing, with dedicated algorithms for pulse shape discrimination and pulse height spectra. For continuous data throughput both data-paths are streamed to the host through two distinct PCIe x8 Direct Memory Access (DMA) channels.
- 30 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 46 (5) , 1291-1297
High-Priority Prototype Testing in Support of System-Level Design Development of the ITER Radial Neutron Camera
This paper describes the high-priority testing activities supporting the ITER radial neutron camera (RNC) design, performed by a consortium of European institutes within a framework contract placed by fusion for energy, the ITER European Domestic Agency. The main role of the RNC is to measure the uncollided 14- and 2.5-MeV neutrons from deuterium-tritium and deuterium-deuterium fusion reactions through an array of flux monitors/spectrometers located in collimated lines of sight viewing the plasma through the ITER equatorial port plug #1. The line-integrated neutron fluxes will be used to evaluate, through reconstruction techniques, the radial profile of the neutrons emitted per unit time and volume (neutron emissivity) and, therefore, the neutron yield and the alpha particles' birth profile. The activity of high-priority testing is dedicated to the preparation and the design of experimental test environment, the conduction of appropriate tests and reporting of test results for the high-priority prototypes, clarifying or verifying the expected key function and system behavior, and enhancing learning on specific issues (potential showstoppers).
- 30 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 46 (5) , 1291-1297
High-Priority Prototype Testing in Support of System-Level Design Development of the ITER Radial Neutron Camera
This paper describes the high-priority testing activities supporting the ITER radial neutron camera (RNC) design, performed by a consortium of European institutes within a framework contract placed by fusion for energy, the ITER European Domestic Agency. The main role of the RNC is to measure the uncollided 14- and 2.5-MeV neutrons from deuterium-tritium and deuterium-deuterium fusion reactions through an array of flux monitors/spectrometers located in collimated lines of sight viewing the plasma through the ITER equatorial port plug #1. The line-integrated neutron fluxes will be used to evaluate, through reconstruction techniques, the radial profile of the neutrons emitted per unit time and volume (neutron emissivity) and, therefore, the neutron yield and the alpha particles' birth profile. The activity of high-priority testing is dedicated to the preparation and the design of experimental test environment, the conduction of appropriate tests and reporting of test results for the high-priority prototypes, clarifying or verifying the expected key function and system behavior, and enhancing learning on specific issues (potential showstoppers).
- 19 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (8) , 2046-2053
Radiation Damage Tests on Diamond and Scintillation Detector Components for the ITER Radial Neutron Camera
During the International Thermonuclear Experimental Reactor (ITER) reactor operation time, the plasma will give rise to high energy neutron and gamma flux, and this intense radiation field will result in serious radiation damage and activation effects on various detectors components. In this paper, neutron detector candidates for the ITER radial neutron camera (RNC), i.e., scintillator components [crystal and plastic scintillators, optical windows, and photomultipliers (PMTs)] and single-crystal diamond detectors, were investigated to establish their radiation hardness and stability under gamma irradiation. Radiation test was carried out at the Italian National Agency for New Technologies, Energy and Sustainable Economic Development Calliope plant (Casaccia R.C., Rome, Italy). The facility is a pool-type irradiation plant equipped with a 60 Co source (energy = 1.25 MeV). Gamma radiation tests were performed in the dark and at room temperature for different total absorbed doses, as required for the application in ITER RNC. Scintillators, PMTs, and optical windows were irradiated up to around 100-kGy absorbed dose, while single-crystal diamond detectors up to around 5 MGy. Scintillators and optical windows transmittance measurements were performed in the UV-VIS range (300–700 nm), paying particular attention to the behavior at 390 and 420 nm (scintillating emission wavelengths). Samples were measured in the dark before and after irradiation and their performances were monitored at room temperature for some weeks in order to study the damage recovery in different conditions. For plastic scintillators, photobleaching and optical bleaching followed by thermal annealing processes in air were made to reduce the radiation damage. Quantum efficiency measurements were performed on the PMTs, and the pulse-height spectra and pulse shape capability of the scintillators were investigated by using gamma and neutron sources. The most relevant results of this paper concern the radiation damage observed in scintillators and diamond detectors. The crystalline scintillator sample showed much less radiation resistance than plastic scintillators. A strong damage to the silver deposition of the diamond contacts was observed already at 1.0 MGy, almost leading to contact destruction at 4.7 MGy.
- 19 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (8) , 2046-2053
Radiation Damage Tests on Diamond and Scintillation Detector Components for the ITER Radial Neutron Camera
During the International Thermonuclear Experimental Reactor (ITER) reactor operation time, the plasma will give rise to high energy neutron and gamma flux, and this intense radiation field will result in serious radiation damage and activation effects on various detectors components. In this paper, neutron detector candidates for the ITER radial neutron camera (RNC), i.e., scintillator components [crystal and plastic scintillators, optical windows, and photomultipliers (PMTs)] and single-crystal diamond detectors, were investigated to establish their radiation hardness and stability under gamma irradiation. Radiation test was carried out at the Italian National Agency for New Technologies, Energy and Sustainable Economic Development Calliope plant (Casaccia R.C., Rome, Italy). The facility is a pool-type irradiation plant equipped with a 60 Co source (energy = 1.25 MeV). Gamma radiation tests were performed in the dark and at room temperature for different total absorbed doses, as required for the application in ITER RNC. Scintillators, PMTs, and optical windows were irradiated up to around 100-kGy absorbed dose, while single-crystal diamond detectors up to around 5 MGy. Scintillators and optical windows transmittance measurements were performed in the UV-VIS range (300–700 nm), paying particular attention to the behavior at 390 and 420 nm (scintillating emission wavelengths). Samples were measured in the dark before and after irradiation and their performances were monitored at room temperature for some weeks in order to study the damage recovery in different conditions. For plastic scintillators, photobleaching and optical bleaching followed by thermal annealing processes in air were made to reduce the radiation damage. Quantum efficiency measurements were performed on the PMTs, and the pulse-height spectra and pulse shape capability of the scintillators were investigated by using gamma and neutron sources. The most relevant results of this paper concern the radiation damage observed in scintillators and diamond detectors. The crystalline scintillator sample showed much less radiation resistance than plastic scintillators. A strong damage to the silver deposition of the diamond contacts was observed already at 1.0 MGy, almost leading to contact destruction at 4.7 MGy.
- 1 October 2015
- Published by Elsevier in Fusion Engineering and Design
- Vol. 96-97, 852-855
First results on runaway electron studies using the FTU neutron camera
- 1 October 2015
- Published by Elsevier in Fusion Engineering and Design
- Vol. 96-97, 852-855
First results on runaway electron studies using the FTU neutron camera
- 4 February 2013
- Published by Elsevier in Fusion Engineering and Design
- Vol. 88 (6-8) , 1178-1182
Real time n/γ discrimination for the JET neutron profile monitor
- 4 February 2013
- Published by Elsevier in Fusion Engineering and Design
- Vol. 88 (6-8) , 1178-1182
Real time n/γ discrimination for the JET neutron profile monitor
- 31 October 2011
- Published by Elsevier in Fusion Engineering and Design
- Vol. 86 (6-8) , 1191-1195
The new digital electronics for the JET Neutron Profile Monitor: Performances and first experimental results
- 31 October 2011
- Published by Elsevier in Fusion Engineering and Design
- Vol. 86 (6-8) , 1191-1195
The new digital electronics for the JET Neutron Profile Monitor: Performances and first experimental results