Heinrich T. Eickhoff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Heinrich T. Eickhoff has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Annette Muetze
Electric Drives and Power Electronic Systems Institute, Graz University of Technology, Graz, Austria
4 shared publications - Roland Seebacher
Electric Drives and Power Electronic Systems Institute, Graz University of Technology Graz Austria
2 shared publications Elias G. Strangas
Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA
1 shared publication- Elias G. Strangas
Electrical and Computer Engineering, Michigan State University, 428 S. Shaw Lane, East Lansing, MI 48824, USA
1 shared publication - Giri Venkataramanan
Department of Electrical & Computer Engineering University of Wisconsin-Madison
1 shared publication - Jyun Lin
Silicon Austria Labs GmbH, Graz, Austria
1 shared publication
Latest Publications
- 16 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 7 (3) , 1127-1136
A Back-EMF Oriented Control of Grid-Supporting Converter
In this work, a self-synchronizing grid-supporting controller for three-phase inverter is proposed. The angle-forming block is cascaded with the current loop, with the $q$-components of the back electromotive force regulated to zero by a proportional-integral controller. It contains the complementary advantages of both grid-following and grid-forming controlled converters. The grid-tied inverters with the proposed controller are stable under wide-range grid strength; and it can better deal with the current saturation issue under different faults, such as frequency and voltage amplitude dips. The control structure is very simple; it is obtained from the conventional phase-locked loop based grid-following algorithm by some minor modifications. The impedance model in $dq$ frame is derived to analyze its dynamics. The effectiveness of the proposed algorithm is verified by experiments in both grid-connected and island modes.
- 16 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 7 (3) , 1127-1136
A Back-EMF Oriented Control of Grid-Supporting Converter
In this work, a self-synchronizing grid-supporting controller for three-phase inverter is proposed. The angle-forming block is cascaded with the current loop, with the $q$-components of the back electromotive force regulated to zero by a proportional-integral controller. It contains the complementary advantages of both grid-following and grid-forming controlled converters. The grid-tied inverters with the proposed controller are stable under wide-range grid strength; and it can better deal with the current saturation issue under different faults, such as frequency and voltage amplitude dips. The control structure is very simple; it is obtained from the conventional phase-locked loop based grid-following algorithm by some minor modifications. The impedance model in $dq$ frame is derived to analyze its dynamics. The effectiveness of the proposed algorithm is verified by experiments in both grid-connected and island modes.
- 8 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (5) , 4958-4969
Space Harmonics and Saturation Interaction in Fault-Tolerant Induction Machine Drives Due to a Zero-Sequence Stator Current
Post-fault operation strategies for three-phase squirrel cage induction machine drives enable increased fault-tolerance in the case of inverter faults. However, in strategies that apply a zero-sequence stator current, additional space harmonics interact with the fundamental wave. This paper studies these space harmonics and the occurring saturation interaction with the main system based on two different induction machines.For illustration, and to support the analysis with quantitative results, it exemplarily investigates the effects of this saturation interaction on the ux linkages and the torque during the post-fault operation of a rotor ux oriented drive.
- 8 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (5) , 4958-4969
Space Harmonics and Saturation Interaction in Fault-Tolerant Induction Machine Drives Due to a Zero-Sequence Stator Current
Post-fault operation strategies for three-phase squirrel cage induction machine drives enable increased fault-tolerance in the case of inverter faults. However, in strategies that apply a zero-sequence stator current, additional space harmonics interact with the fundamental wave. This paper studies these space harmonics and the occurring saturation interaction with the main system based on two different induction machines.For illustration, and to support the analysis with quantitative results, it exemplarily investigates the effects of this saturation interaction on the ux linkages and the torque during the post-fault operation of a rotor ux oriented drive.
- 23 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (5) , 4104-4113
Thermal Performance Modeling of Foil Conductor Concentrated Windings in Electric Machines
While the use of foil windings in transformers and air core inductors is not uncommon, their use in electric machines is just emerging. Although prototype realizations have been reported in the literature, a definitive analysis of their thermal performance is necessary to evaluate their potential for broad applications. This paper is devoted to presenting a comprehensive model for evaluating their thermal performance including loss modeling and temperature rise prediction in realistic designs. An overview of foil windings in electric machines and their advantages in improved fill factor is presented, along with experimental results that compare the AC losses and temperature distribution under identical steady-state operating conditions with a prototype round conductor coil and foil conductor coil. A lumped parameter thermal model that predicts the heat transfer behavior of the foil conductor coil is presented along with supporting experimental results.
- 23 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (5) , 4104-4113
Thermal Performance Modeling of Foil Conductor Concentrated Windings in Electric Machines
While the use of foil windings in transformers and air core inductors is not uncommon, their use in electric machines is just emerging. Although prototype realizations have been reported in the literature, a definitive analysis of their thermal performance is necessary to evaluate their potential for broad applications. This paper is devoted to presenting a comprehensive model for evaluating their thermal performance including loss modeling and temperature rise prediction in realistic designs. An overview of foil windings in electric machines and their advantages in improved fill factor is presented, along with experimental results that compare the AC losses and temperature distribution under identical steady-state operating conditions with a prototype round conductor coil and foil conductor coil. A lumped parameter thermal model that predicts the heat transfer behavior of the foil conductor coil is presented along with supporting experimental results.
- 19 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (3) , 2381-2391
Post-Fault Operation Strategy for Single Switch Open-Circuit Faults in Electric Drives
Single switch open-circuit faults in three-phase ac drives lead to undesired effects and potentially to a total failure of the drive. This paper proposes a postfault operation strategy for such faults with a focus on the limitation of losses after the reconfiguration and thereby an extension of the possible range of operation. Furthermore, a method for the reduction of alternating torque components during the postfault operation of a squirrel cage induction machine drive is proposed. The performance of the postfault operation strategy and the alternating torque reduction method are shown both via simulations and experiments.
- 19 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (3) , 2381-2391
Post-Fault Operation Strategy for Single Switch Open-Circuit Faults in Electric Drives
Single switch open-circuit faults in three-phase ac drives lead to undesired effects and potentially to a total failure of the drive. This paper proposes a postfault operation strategy for such faults with a focus on the limitation of losses after the reconfiguration and thereby an extension of the possible range of operation. Furthermore, a method for the reduction of alternating torque components during the postfault operation of a squirrel cage induction machine drive is proposed. The performance of the postfault operation strategy and the alternating torque reduction method are shown both via simulations and experiments.
- 22 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 53 (6) , 5415-5425
Enhanced and Fast Detection of Open-Switch Faults in Inverters for Electric Drives
Open-switch faults in inverter-driven electric drives have recently gained increasing attention in the scientific community. Since these faults may lead to undesired effects, their fast and unambiguous detection is desirable. This paper proposes a detection algorithm for open-switch faults, which is based on the observation of the current control deviation and a subsequent test procedure. This algorithm detects the fault immediately after its occurrence within a few switching periods, even during transient operation. The proposed method is tested via simulations and experiments at different operating points of a surface permanent magnet drive.
- 22 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 53 (6) , 5415-5425
Enhanced and Fast Detection of Open-Switch Faults in Inverters for Electric Drives
Open-switch faults in inverter-driven electric drives have recently gained increasing attention in the scientific community. Since these faults may lead to undesired effects, their fast and unambiguous detection is desirable. This paper proposes a detection algorithm for open-switch faults, which is based on the observation of the current control deviation and a subsequent test procedure. This algorithm detects the fault immediately after its occurrence within a few switching periods, even during transient operation. The proposed method is tested via simulations and experiments at different operating points of a surface permanent magnet drive.