HTHerbert J. Tobias

Herbert J. Tobias

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Herbert J. Tobias has a total of 284 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Liquid Chromatography Coupled to Isotope Ratio Mass Spectrometry Expanded to Include Organic Mobile Phases

    by Herbert J. Tobias, Andrew Jones, Thomas R. Saunders, J. Thomas Brenna

    Current commercially available liquid chromatography coupled to isotope ratio mass spectrometry systems (LC-IRMS) oxidize all eluent and thus can only operate with all-aqueous mobile phases, limiting their application to a small subset of analytes and mixtures that can be separated without organic solvents. We report a novel rotating-catalytic disc desolvation device with subsequent laser-activated photocatalytic analyte combustion to create CO2 for high precision carbon isotope ratio measurements compatible with both aqueous and organic liquid mobile phases. Sucrose, glucose, androsterone, or androsterone acetate in 20% and 50% H2O-CH3OH solutions were introduced by flow injection to the interface to IRMS for sugars and steroids, respectively. Sucrose δ13CVPDB linearity was excellent over 1-10 μg (33-655 nmol C) injections, using IRMS compatible He/1%O2 oxidation gas. The limit of precise isotope analysis (LOIA) of δ13CVPDB was 1 μg (35 nmol C) for sucrose and 10 μg (655 nmol C) for androsterone with average precisions of SD(δ13C) ± 0.8‰. Calibration was performed with and bracketed the δ13CVPDB isotope ratio range using androsterone-acetate and glucose. With further development to improve sensitivity and application to chromatography, the prototype proof-of-principle LC-IRMS shows promise to resolve a major drawback in current LC-IRMS systems and may open LC-IRMS to many more compounds than currently possible.


  • Fatty acid sentinels as covalently bound randomization standards for triacylglycerol (TAG) quantitative analysis

    by Dong Hao Wang, Zhen Wang, Secilia Martinez, Herbert J. Tobias, J. Thomas Brenna

    Rationale: Quantitative analysis of triacylglycerols (TAG) is impeded by a lack of standards and the huge number of potential TAG molecular species that may be present due to the combinatorial nature of glycerolipids. Randomization of acyl groups yields TAG mixtures with profiles predictable from fatty acid profiles; however, their use as calibration mixtures has been limited. Methods: We introduce here the principle of fatty acid isotopic sentinels that are quantitatively added prior to randomization to enable verification that randomization is complete, and that can be used as internal standards. A mixture of two isotopically labeled fatty acid methyl esters (FAME) is prepared at a ratio of 2:1 and the exact ratio is carefully measured by gas chromatography flame ionization detection (GC‐FID) and randomized covalently into the acyl groups of TAG mixtures. Results: Reaction with catalytic amounts of NaOCH 3 yields complete randomization, such that the product FAME and TAG have the same fatty acid profile. TAG mixture analysis reveals that the isotopic sentinels have been covalently incorporated into the TAG molecular species at <1% deviation from the expected proportions, thus verifying randomization within experimental error. Conclusions: The sentinel principle demonstrated here as covalently incorporated internal standards verifies that randomization chemistry went to completion. It applies in general to use of combinatorial chemistry for quantitative standards.


  • Structural Identification of Monounsaturated Branched Chain Fatty Acid Methyl Esters by Combination of Electron Ionization and Covalent Adduct Chemical Ionization Tandem Mass Spectrometry

    by Zhen Wang, Dong Hao Wang, Hui Gyu Park, Herbert J. Tobias, Kumar S. D. Kothapalli, J. Thomas Brenna

    Monounsaturated normal fatty acids (n-MUFA) and saturated branched chain fatty acids (BCFA) are structurally characterized by separate tandem mass spectrometry methods for double bond localization and for chain branching in their respective fatty acid methyl ester (FAME) derivatives, however these methods have never been applied to branched monounsaturated FAME. Here we report application of electron ionization (EI)-MS/MS and solvent-mediated covalent adduct chemical ionization (CACI)-MS/MS of monounsaturated BCFA methyl esters (MUBCFAME) of chain length 15-20 carbons. A novel system was used to implement CI with low vapor pressure reagents in a tabletop triple quadrupole MS. Anteiso-MUBCFA EI-MS/MS of the molecular ion (M) yields a characteristic diagnostic ion [M-29]+. iso-MUBCFA can be distinguished from n-MUFA by an ion intensity ratio of [M-32]+/[M-43]+, with iso-MUBCFA yielding a ratio >1.7 while n-MUFA yield a ratio <1.0. Chain branching at the iso and anteiso positions, terminal isopropyl and sec-butyl, respectively, do not alter CACI-MS/MS diagnostic ions compared to normal BCFA, enabling double bond positions of MUBCFA to be determined with the analogous α and ω diagnostic ions from cleavage on both sides of the erstwhile double bond. Taken together, this straightforward FAME-based technique via combination of EI-MS/MS and CACI-MS/MS enables fundamental structural identification of MUBCFA without standards.


  • Potentially High Value Conjugated Linolenic Acids (CLnA) in Melon Seed Waste

    by Dong Hao Wang, Zhen Wang, Kim Phuong Le, J. Raven Cortright, Hui Gyu Park, Herbert J. Tobias, J. Thomas Brenna

    Conjugated linolenic acids (CLnAs) are natural phytochemicals with known and potential bioactivities in mammals. Established CLnA sources are limited to a few common fruit seeds, notably pomegranate seeds and cherry pits, and the search for alternatives is impeded in part by cumbersome methods for reliable measurement. We investigated CLnA contents in lower value fruit seeds with a recently available facile mass spectrometry method enabling positive identification and quantitative analysis. We report for the first time detection of CLnAs in cantaloupe and honeydew seeds at levels of 2 mg CLnA/g seed kernel. Based on the combined waste stream for these muskmelons of about 1.4 billion pounds in USA annually, we estimate that the available CLnAs amount to 37.5 tons, similar to cherry pits. Our results suggest potential enhanced economic value of a specific class of bioactives that may be extracted from discarded food processing waste.


  • Low Temperature Catalytic Combustion Reactors for High Precision Carbon Isotope Measurements in Gas Chromatography Combustion Isotope Ratio Mass Spectrometry

    by Herbert J. Tobias, Andrew Jones, Charlie Spanjers, Larry Bowers, J. Thomas Brenna

    Metal oxide-filled reactors constructed with ceramic tubes or fused silica capillary are widely used for combustion in gas chromatography combustion isotope ratio mass spectrometry (GCC-IRMS). However, they tend to be easily cracked or broken and prone to leaks at operating temperatures of ∼950 °C. Here we introduce a modified commercially available catalytic combustion/reduction methanizer to quantitatively convert organics to CO2 for δ13C analysis while retaining chromatographic resolution. These modified “ARC” reactors operate with a transition-metal catalyst that requires a flowing O2 gas to enable complete conversion to CO2 at lower temperature (620 °C) with acceptable reactor life, reduced complexity, and improved robustness. Performance of two versions of the ARC reactors with different combustion volumes was characterized by analysis of steroid and alkane isotopic standard materials. Linearity of steroid isotopic standards ranged from 0.02 to 0.60 ‰/V in the range of 25 to 200 ng of each steroid injected. Precisions and accuracies of measurements for steroids and alkanes had average standard deviations of SD(δ13C) less than ±0.18 ‰ and average accuracy of better than 0.19 ‰ δ13CVPDB. Peak width expansion within both devices were similar to that in traditionally used metal oxide reactors. These data demonstrate for the first time that novel combustion schemes enable operation at lower temperatures as an alternative approach comparable to high temperature techniques to yield high precision δ13C data with GCC-IRMS.


  • Cryofocus fast gas chromatography combustion isotope ratio mass spectrometry for rapid detection of synthetic steroid use in sport doping

    by Herbert J. Tobias, J. Thomas Brenna

    Sports doping requires high precision carbon isotope ratio (CIR) analysis of endogenous steroids using gas chromatography-combustion isotope ratio mass spectrometry (GCC-IRMS), however methods are relatively slow and cumbersome. A cryofocusing fast GCC-IRMS (Cryofocus Fast GCC-IRMS) was developed and optimized with minimal peak broadening using a programmable temperature vaporization (PTV) inlet and a low dead volume narrow-bore continuous capillary combustion interface to an IRMS. PTV injection, followed with cryofocusing before steroid analytes were volatilized by a hot jet, was used to initiate chromatography. Compared to ramping temperature using a conventional GC oven, cryofocusing with hot jet volatilization reduced analysis time by a factor of 3 to 4 and reduced peak widths to ∼800 ms. Well separated peak isotope ratios were measured with SD(δ13C) < 0.5‰ over a range of 10–50 ng of each steroid on column and were accurate from 2 ng to 100 ng. Characterization of the current experimental system with well characterized pure steroid isotopic standards demonstrates how the technique can be applied to steroid mixtures derived from real urine samples. Cryofocus Fast GCC-IRMS advances toward the goal of routine CIR testing of steroids in all urine samples for doping control.


  • High‐volume steroid isotopic standards developed as working standards for gas chromatography–combustion–isotope ratio mass spectrometry

    by Herbert J. Tobias, J. Thomas Brenna

    High‐precision carbon isotope ratio analysis of urinary steroids by gas chromatography–combustion–isotope ratio mass spectrometry (GC–C–IRMS) is the official test to detect illicit doping of synthetic versions of endogenous steroids, such as testosterone. Our group created the first steroid isotopic standards (SIS) specifically for World Anti‐Doping Agency (WADA) accredited laboratories. The standards contain mixtures of steroids as acetates or free steroids at ~400 μg each per ampoule and have been widely distributed to anti‐doping laboratories to facilitate comparability of inter‐laboratory results. Here we report on the creation and characterization of 3 new high‐volume single component SIS suitable for use as working standards. They contain ~50 times more steroid mass per ampoule than previous SIS. The new SIS, coded CU/PCC 40‐1, CU/PCC 41‐1, & CU/PCC 42‐1, contain ~20 mg of androsterone, androsterone‐AC, and 5α‐cholestane, with determined isotopic values of ‐27.09 ± 0.07 mUr, ‐32.82 ± 0.01 mUr, ‐25.03 ± 0.01 mUr, respectively. We used our previously developed protocol to calibrate the isotopically uniform steroids against the isotopic standard gases methane and ethane in NIST RM 8559 that are traceable to the international standard Vienna PeeDee Belemnite (VPDB). Two sets of data, acquired 7 months apart, of absolute δ13CVPDB and ∆Δδ13CVPDB values from 8 randomly selected ampoules of all 3 SIS indicate uniformity of steroid isotopic composition within measurement reproducibility, SD(δ13C) < 0.2 mUr Our results show that protocols for SIS extend to creation of high volume working standards that can also be used as internal standards under appropriate GC conditions.


  • Quantifying the Contribution of Grape Hexoses to Wine Volatiles by High-Precision [U13C]-Glucose Tracer Studies

    by Mark A. Nisbet, Herbert J. Tobias, J. Thomas Brenna, Gavin L. Sacks, Anna Katharine Mansfield

    Many fermentation volatiles important to wine aroma potentially arise from yeast metabolism of hexose sugars, but assessing the relative importance of these pathways is challenging due to high endogenous hexose substrate concentrations. To overcome this problem, gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) was used to measure high-precision 13C/12C isotope ratios of volatiles in wines produced from juices spiked with tracer levels (0.01–1 APE) of uniformly labeled [U-13C]-glucose. The contribution of hexose to individual volatiles was determined from the degree of 13C enrichment. As expected, straight-chain fatty acids and their corresponding ethyl esters were derived almost exclusively from hexoses. Most fusel alcohols and their acetate esters were also majority hexose-derived, indicating the importance of anabolic pathways for their formation. Only two compounds were not derived primarily from hexoses (hexanol and isobutyric acid). This approach can be extended to other food systems or substrates for studying precursor–product relationships.


  • Open Access

    Toward unsupervised single-shot diffractive imaging of heterogeneous particles using X-ray free-electron lasers

    by Hyung Joo Park, N. Duane Loh, Raymond G. Sierra, Christina Y. Hampton, Dmitri Starodub, Andrew V. Martin, Anton Barty, Andrew Aquila, Joachim Schulz, Jan Steinbrener, et al.

    Single shot diffraction imaging experiments via X-ray free-electron lasers can generate as many as hundreds of thousands of diffraction patterns of scattering objects. Recovering the real space contrast of a scattering object from these patterns currently requires a reconstruction process with user guidance in a number of steps, introducing severe bottlenecks in data processing. We present a series of measures that replace user guidance with algorithms that reconstruct contrasts in an unsupervised fashion. We demonstrate the feasibility of automating the reconstruction process by generating hundreds of contrasts obtained from soot particle diffraction experiments.