Remi Geiger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Remi Geiger has a total of 178 co-authors. Here are the top co-authors by number of shared publications:
- Arnaud Landragin
LTE LNE Observatoire de Paris Université PSL Sorbonne Université Université de Lille CNRS 61 Avenue de l'Observatoire 75014 Paris France
27 shared publications - Phillippe Bouyer
Laboratoire Photonique, Numerique et Nanosciences
12 shared publications - Jörg Schmiedmayer
TU Wien
9 shared publications - Tim Langen
Universität Stuttgart
9 shared publications - Bess Fang
LNE-SYRTE Observatoire de Paris Université PSL CNRS Sorbonne Université 61 Avenue de l'Observatoire 75014 Paris France
8 shared publications A. Landragin
LNE-SYRTE Observatoire de Paris Université PSL CNRS Sorbonne Université 61 Avenue de l'Observatoire 75014 Paris France
6 shared publications
Latest Publications
- 30 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Senseur inertiel à ondes de matière aéroporté
: cette thèse porte sur l’étude d’un accéléromètre à ondes de matière fonctionnant à bord d’un avion effectuant des vols paraboliques et permettant des expériences en micro-gravité (0-g). Un interféromètre à atomes de 87Rb refroidis par laser, et dont les états quantiques sont manipulés à l’aide de transitions Raman stimulées, constitue l’élément physique du capteur. Lors de la conception du dispositif expérimental, un effort particulier a été apporté au choix d’une source laser transportable, stable, et robuste. Nous démontrons pour la première fois le fonctionnement aéroporté d’un senseur inertiel à ondes de matière, à la fois en 0-g et durant les phases de gravité des vols (1-g). Nous proposons une technique combinant le signal de l’interféromètre à celui d’accéléromètres mécaniques auxiliaires pour effectuer des mesures au dela de la dynamique intrinsèque du capteur atomique. Nous expliquons comment bénéficier du haut niveau de sensibilité de l’interféromètre dans l’avion, et indiquons des voies d’améliorations significatives de notre dispositif pour le futur. En 0-g, nous montrons une amélioration de la sensibilité de l’accéléromètre jusque 2 x 10-4 m.s-2 à une seconde, et étudions une réjection des vibrations de l’avion à l’aide d’un interféromètre à quatre impulsions Raman. L’objectif de notre projet consiste en un test du principe d’universalité de la chute libre avec un double accéléromètre à atomes de 87Rb et de 39K. Notre système laser double-espèce emploie des composants optiques fibrés aux longueurs d’onde de 1.56 et 1.54 μm, ainsi qu’un doublage de fréquence pour obtenir la lumière utile à 780 et 767 nm pour le refroidissement et la manipulation des deux atomes. Nous étudions théoriquement la sensibilité d’une mesure de leur différence d’accélération en tenant compte des vibrations de l’avion, et précisons comment une résolution de l’ordre de 10-10 m.s-2 pourra être atteinte dans le futur avec notre expérience aéroportée.
- 30 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Senseur inertiel à ondes de matière aéroporté
: cette thèse porte sur l’étude d’un accéléromètre à ondes de matière fonctionnant à bord d’un avion effectuant des vols paraboliques et permettant des expériences en micro-gravité (0-g). Un interféromètre à atomes de 87Rb refroidis par laser, et dont les états quantiques sont manipulés à l’aide de transitions Raman stimulées, constitue l’élément physique du capteur. Lors de la conception du dispositif expérimental, un effort particulier a été apporté au choix d’une source laser transportable, stable, et robuste. Nous démontrons pour la première fois le fonctionnement aéroporté d’un senseur inertiel à ondes de matière, à la fois en 0-g et durant les phases de gravité des vols (1-g). Nous proposons une technique combinant le signal de l’interféromètre à celui d’accéléromètres mécaniques auxiliaires pour effectuer des mesures au dela de la dynamique intrinsèque du capteur atomique. Nous expliquons comment bénéficier du haut niveau de sensibilité de l’interféromètre dans l’avion, et indiquons des voies d’améliorations significatives de notre dispositif pour le futur. En 0-g, nous montrons une amélioration de la sensibilité de l’accéléromètre jusque 2 x 10-4 m.s-2 à une seconde, et étudions une réjection des vibrations de l’avion à l’aide d’un interféromètre à quatre impulsions Raman. L’objectif de notre projet consiste en un test du principe d’universalité de la chute libre avec un double accéléromètre à atomes de 87Rb et de 39K. Notre système laser double-espèce emploie des composants optiques fibrés aux longueurs d’onde de 1.56 et 1.54 μm, ainsi qu’un doublage de fréquence pour obtenir la lumière utile à 780 et 767 nm pour le refroidissement et la manipulation des deux atomes. Nous étudions théoriquement la sensibilité d’une mesure de leur différence d’accélération en tenant compte des vibrations de l’avion, et précisons comment une résolution de l’ordre de 10-10 m.s-2 pourra être atteinte dans le futur avec notre expérience aéroportée.
- Top Cited PapersOpen Access
- 10 June 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (23)
Accurate measurement of the Sagnac effect for matter waves
A rotating interferometer with paths that enclose a physical area exhibits a phase shift proportional to this area and to the rotation rate of the frame. Understanding the origin of this so-called Sagnac effect has played a key role in the establishment of the theory of relativity and has pushed for the development of precision optical interferometers. The fundamental importance of the Sagnac effect motivated the realization of experiments to test its validity for waves beyond optical, but precision measurements remained a challenge. Here, we report the accurate test of the Sagnac effect for matter waves, by using a Cesium atom interferometer featuring a geometrical area of 11 cm 2 and two sensitive axes of measurements. We measure the phase shift induced by Earth’s rotation and find agreement with the theoretical prediction at an accuracy level of 25 parts per million. Beyond the importance for fundamental physics, our work opens practical applications in seismology and geodesy.
- 10 June 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (23)
Top Cited PapersOpen AccessAccurate measurement of the Sagnac effect for matter waves
A rotating interferometer with paths that enclose a physical area exhibits a phase shift proportional to this area and to the rotation rate of the frame. Understanding the origin of this so-called Sagnac effect has played a key role in the establishment of the theory of relativity and has pushed for the development of precision optical interferometers. The fundamental importance of the Sagnac effect motivated the realization of experiments to test its validity for waves beyond optical, but precision measurements remained a challenge. Here, we report the accurate test of the Sagnac effect for matter waves, by using a Cesium atom interferometer featuring a geometrical area of 11 cm 2 and two sensitive axes of measurements. We measure the phase shift induced by Earth’s rotation and find agreement with the theoretical prediction at an accuracy level of 25 parts per million. Beyond the importance for fundamental physics, our work opens practical applications in seismology and geodesy.
- Open Access
Degenerate optical resonator for the enhancement of large laser beams
Enhancement cavities where a beam of large size (several millimeters) can resonate have several applications, in particular in atomic physics. However, reaching large beam waists in a compact geometry (less than a meter long) typically brings the resonator close to the degeneracy limit. Here we experimentally study a degenerate optical cavity, 44-cm long and consisting of two flat mirrors placed in the focal planes of a lens, in a regime of intermediate finesse ($\sim 150$). We study the impact of the longitudinal misalignement on the optical gain, for different input beam waists up to 5.6~mm, and find data consistent with the prediction of a model based on ABCD propagation of Gaussian beams. We reach an optical gain of 26 for a waist of 1.4~mm, which can have an impact on several applications, in particular atom interferometry. We numerically investigate the optical gain reduction for large beam waists using the angular spectrum method to consider the effects of optical aberrations, which play an important role in such a degenerate cavity. Our calculations quantitatively reproduce the experimental data and will provide a key tool for designing enhancement cavities close to the degeneracy limit. As an illustration, we discuss the application of this resonator geometry to the enhancement of laser beams with top-hat intensity profiles.
Open AccessDegenerate optical resonator for the enhancement of large laser beams
Enhancement cavities where a beam of large size (several millimeters) can resonate have several applications, in particular in atomic physics. However, reaching large beam waists in a compact geometry (less than a meter long) typically brings the resonator close to the degeneracy limit. Here we experimentally study a degenerate optical cavity, 44-cm long and consisting of two flat mirrors placed in the focal planes of a lens, in a regime of intermediate finesse ($\sim 150$). We study the impact of the longitudinal misalignement on the optical gain, for different input beam waists up to 5.6~mm, and find data consistent with the prediction of a model based on ABCD propagation of Gaussian beams. We reach an optical gain of 26 for a waist of 1.4~mm, which can have an impact on several applications, in particular atom interferometry. We numerically investigate the optical gain reduction for large beam waists using the angular spectrum method to consider the effects of optical aberrations, which play an important role in such a degenerate cavity. Our calculations quantitatively reproduce the experimental data and will provide a key tool for designing enhancement cavities close to the degeneracy limit. As an illustration, we discuss the application of this resonator geometry to the enhancement of laser beams with top-hat intensity profiles.
- 11 December 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (26) , 39112-39127
Degenerate optical resonator for the enhancement of large laser beams
There are several applications for enhancement cavities where a beam of large size (several millimeters) resonates, in particular in atomic physics. However, reaching large beam waists in a compact geometry (less than a meter long) typically brings the resonator close to the degeneracy limit. Here we experimentally study a degenerate optical cavity, 44-cm long and consisting of two flat mirrors placed in the focal planes of a lens, in a regime of intermediate finesse (∼150). We study the impact of the longitudinal misalignement on the optical gain, for different input beam waists up to 5.6 mm, and find data consistent with the prediction of a model based on ABCD propagation of Gaussian beams. We reach an optical gain of 26 for a waist of 1.4 mm, which can have an impact on several applications, in particular atom interferometry. We numerically investigate the optical gain reduction for large beam waists using the angular spectrum method to consider the effects of optical aberrations, which play an important role in such a degenerate cavity. Our calculations quantitatively reproduce the experimental data and will provide a key tool for designing enhancement cavities close to the degeneracy limit. As an illustration, we discuss the application of this resonator geometry to the enhancement of laser beams with top-hat intensity profiles.
- 11 December 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (26) , 39112-39127
Degenerate optical resonator for the enhancement of large laser beams
There are several applications for enhancement cavities where a beam of large size (several millimeters) resonates, in particular in atomic physics. However, reaching large beam waists in a compact geometry (less than a meter long) typically brings the resonator close to the degeneracy limit. Here we experimentally study a degenerate optical cavity, 44-cm long and consisting of two flat mirrors placed in the focal planes of a lens, in a regime of intermediate finesse (∼150). We study the impact of the longitudinal misalignement on the optical gain, for different input beam waists up to 5.6 mm, and find data consistent with the prediction of a model based on ABCD propagation of Gaussian beams. We reach an optical gain of 26 for a waist of 1.4 mm, which can have an impact on several applications, in particular atom interferometry. We numerically investigate the optical gain reduction for large beam waists using the angular spectrum method to consider the effects of optical aberrations, which play an important role in such a degenerate cavity. Our calculations quantitatively reproduce the experimental data and will provide a key tool for designing enhancement cavities close to the degeneracy limit. As an illustration, we discuss the application of this resonator geometry to the enhancement of laser beams with top-hat intensity profiles.
- 19 November 2020
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 125 (21) , 213201
Tailoring Multiloop Atom Interferometers with Adjustable Momentum Transfer
Multiloop matter-wave interferometers are essential in quantum sensing to measure the derivatives of physical quantities in time or space. Because multiloop interferometers require multiple reflections, imperfections of the matter-wave mirrors create spurious paths that scramble the signal of interest. Here, we demonstrate a method of adjustable momentum transfer that prevents the recombination of the spurious paths in a double-loop atom interferometer aimed at measuring rotation rates. We experimentally study the recombination condition of the spurious matter waves, which is quantitatively supported by a model accounting for the coherence properties of the atomic source. We finally demonstrate the effectiveness of the method in building a cold-atom gyroscope with a single-shot acceleration sensitivity suppressed by a factor of at least 50. Our study will impact the design of multiloop atom interferometers that measure a single inertial quantity.
- 19 November 2020
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 125 (21) , 213201
Tailoring Multiloop Atom Interferometers with Adjustable Momentum Transfer
Multiloop matter-wave interferometers are essential in quantum sensing to measure the derivatives of physical quantities in time or space. Because multiloop interferometers require multiple reflections, imperfections of the matter-wave mirrors create spurious paths that scramble the signal of interest. Here, we demonstrate a method of adjustable momentum transfer that prevents the recombination of the spurious paths in a double-loop atom interferometer aimed at measuring rotation rates. We experimentally study the recombination condition of the spurious matter waves, which is quantitatively supported by a model accounting for the coherence properties of the atomic source. We finally demonstrate the effectiveness of the method in building a cold-atom gyroscope with a single-shot acceleration sensitivity suppressed by a factor of at least 50. Our study will impact the design of multiloop atom interferometers that measure a single inertial quantity.
- Top Cited PapersOpen Access
- 28 October 2020
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 37 (22) , 225017
ELGAR—a European Laboratory for Gravitation and Atom-interferometric Research
Gravitational waves (GWs) were observed for the first time in 2015, one century after Einstein predicted their existence. There is now growing interest to extend the detection bandwidth to low frequency. The scientific potential of multi-frequency GW astronomy is enormous as it would enable to obtain a more complete picture of cosmic events and mechanisms. This is a unique and entirely new opportunity for the future of astronomy, the success of which depends upon the decisions being made on existing and new infrastructures. The prospect of combining observations from the future space-based instrument LISA together with third generation ground based detectors will open the way toward multi-band GW astronomy, but will leave the infrasound (0.1–10 Hz) band uncovered. GW detectors based on matter wave interferometry promise to fill such a sensitivity gap. We propose the European Laboratory for Gravitation and Atom-interferometric Research (ELGAR), an underground infrastructure based on the latest progress in atomic physics, to study space–time and gravitation with the primary goal of detecting GWs in the infrasound band. ELGAR will directly inherit from large research facilities now being built in Europe for the study of large scale atom interferometry and will drive new pan-European synergies from top research centers developing quantum sensors. ELGAR will measure GW radiation in the infrasound band with a peak strain sensitivity of 3.3 × 1 0 − 22 / Hz at 1.7 Hz. The antenna will have an impact on diverse fundamental and applied research fields beyond GW astronomy, including gravitation, general relativity, and geology.
- 28 October 2020
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 37 (22) , 225017
Top Cited PapersOpen AccessELGAR—a European Laboratory for Gravitation and Atom-interferometric Research
Gravitational waves (GWs) were observed for the first time in 2015, one century after Einstein predicted their existence. There is now growing interest to extend the detection bandwidth to low frequency. The scientific potential of multi-frequency GW astronomy is enormous as it would enable to obtain a more complete picture of cosmic events and mechanisms. This is a unique and entirely new opportunity for the future of astronomy, the success of which depends upon the decisions being made on existing and new infrastructures. The prospect of combining observations from the future space-based instrument LISA together with third generation ground based detectors will open the way toward multi-band GW astronomy, but will leave the infrasound (0.1–10 Hz) band uncovered. GW detectors based on matter wave interferometry promise to fill such a sensitivity gap. We propose the European Laboratory for Gravitation and Atom-interferometric Research (ELGAR), an underground infrastructure based on the latest progress in atomic physics, to study space–time and gravitation with the primary goal of detecting GWs in the infrasound band. ELGAR will directly inherit from large research facilities now being built in Europe for the study of large scale atom interferometry and will drive new pan-European synergies from top research centers developing quantum sensors. ELGAR will measure GW radiation in the infrasound band with a peak strain sensitivity of 3.3 × 1 0 − 22 / Hz at 1.7 Hz. The antenna will have an impact on diverse fundamental and applied research fields beyond GW astronomy, including gravitation, general relativity, and geology.
- Open Access
- 1 June 2020
- Published by American Vacuum Society in AVS Quantum Science
- Vol. 2 (2) , 024702
High-accuracy inertial measurements with cold-atom sensors
The research on cold-atom interferometers gathers a large community of about 50 groups worldwide both in the academic and now in the industrial sectors. The interest in this sub-field of quantum sensing and metrology lies in the large panel of possible applications of cold-atom sensors for measuring inertial and gravitational signals with a high level of stability and accuracy. This review presents the evolution of the field over the last 30 years and focuses on the acceleration of the research effort in the last 10 years. The article describes the physics principle of cold-atom gravito-inertial sensors as well as the main parts of hardware and the expertise required when starting the design of such sensors. The author then reviews the progress in the development of instruments measuring gravitational and inertial signals, with a highlight on the limitations to the performances of the sensors, on their applications and on the latest directions of research.
- 1 June 2020
- Published by American Vacuum Society in AVS Quantum Science
- Vol. 2 (2) , 024702
Open AccessHigh-accuracy inertial measurements with cold-atom sensors
The research on cold-atom interferometers gathers a large community of about 50 groups worldwide both in the academic and now in the industrial sectors. The interest in this sub-field of quantum sensing and metrology lies in the large panel of possible applications of cold-atom sensors for measuring inertial and gravitational signals with a high level of stability and accuracy. This review presents the evolution of the field over the last 30 years and focuses on the acceleration of the research effort in the last 10 years. The article describes the physics principle of cold-atom gravito-inertial sensors as well as the main parts of hardware and the expertise required when starting the design of such sensors. The author then reviews the progress in the development of instruments measuring gravitational and inertial signals, with a highlight on the limitations to the performances of the sensors, on their applications and on the latest directions of research.
- Open Access
High-accuracy inertial measurements with cold-atom sensors
The research on cold-atom interferometers gathers a large community of about 50 groups worldwide both in the academic and now in the industrial sectors. The interest in this sub-field of quantum sensing and metrology lies in the large panel of possible applications of cold-atom sensors for measuring inertial and gravitational signals with a high level of stability and accuracy. This review presents the evolution of the field over the last 30 years and focuses on the acceleration of the research effort in the last 10 years. The article describes the physics principle of cold-atom gravito-inertial sensors as well as the main parts of hardware and the expertise required when starting the design of such sensors. It then reviews the progress in the development of instruments measuring gravitational and inertial signals, with a highlight on the limitations to the performances of the sensors, on their applications, and on the latest directions of research.
Open AccessHigh-accuracy inertial measurements with cold-atom sensors
The research on cold-atom interferometers gathers a large community of about 50 groups worldwide both in the academic and now in the industrial sectors. The interest in this sub-field of quantum sensing and metrology lies in the large panel of possible applications of cold-atom sensors for measuring inertial and gravitational signals with a high level of stability and accuracy. This review presents the evolution of the field over the last 30 years and focuses on the acceleration of the research effort in the last 10 years. The article describes the physics principle of cold-atom gravito-inertial sensors as well as the main parts of hardware and the expertise required when starting the design of such sensors. It then reviews the progress in the development of instruments measuring gravitational and inertial signals, with a highlight on the limitations to the performances of the sensors, on their applications, and on the latest directions of research.
- Open Access
- 23 March 2020
- Published by Copernicus GmbH
Towards a two-axis cold-atom gyroscope for rotational seismology
Cold-atom inertial sensors target several applications in navigation, prospection, geoscience and tests of fundamental physics. The operation of these sensors is based on atomic interferometry taking advantage of superpositions between quantum states of different momentum of an atom. These superposition states are obtained by means of optical transitions with two (or more) photons communicating momentum to the atom and acting as beam splitters and mirrors for the matter waves. The SYRTE cold-atom gyroscope currently represent the state of the art of atomic gyroscopes with a short-term sensitivity of 40 nrad/s/sqrt(Hz) limited by vibration noise (using a 4 Hz sampling rate), a long term stability of 3e-10 rad/s and an accuracy of 10 nrad/s. The detection noise limit of the sensor (quantum projection noise) is currently 5 nrad/s/sqrt(Hz) in the band DC-1 Hz, which already represents an interest to sense ground rotations in a typical frequency range between 1 mHz and 1 Hz. A second horizontal axis of measurement is currently being implemented. Moreover, we are designing a new experiment which aims a reaching a (quantum projection noise limited) sensitivity of 1 nrad/s/sqrt(Hz) in this frequency band along two axes of measurement, which represents an interesting perspective for the field of rotational seismology. This contribution will present the results recently achieved with the SYRTE gyroscope experiment to reach state-of-the-art performances and present the route to applications of this sensor in geosciences.
- 23 March 2020
- Published by Copernicus GmbH
Open AccessTowards a two-axis cold-atom gyroscope for rotational seismology
Cold-atom inertial sensors target several applications in navigation, prospection, geoscience and tests of fundamental physics. The operation of these sensors is based on atomic interferometry taking advantage of superpositions between quantum states of different momentum of an atom. These superposition states are obtained by means of optical transitions with two (or more) photons communicating momentum to the atom and acting as beam splitters and mirrors for the matter waves. The SYRTE cold-atom gyroscope currently represent the state of the art of atomic gyroscopes with a short-term sensitivity of 40 nrad/s/sqrt(Hz) limited by vibration noise (using a 4 Hz sampling rate), a long term stability of 3e-10 rad/s and an accuracy of 10 nrad/s. The detection noise limit of the sensor (quantum projection noise) is currently 5 nrad/s/sqrt(Hz) in the band DC-1 Hz, which already represents an interest to sense ground rotations in a typical frequency range between 1 mHz and 1 Hz. A second horizontal axis of measurement is currently being implemented. Moreover, we are designing a new experiment which aims a reaching a (quantum projection noise limited) sensitivity of 1 nrad/s/sqrt(Hz) in this frequency band along two axes of measurement, which represents an interesting perspective for the field of rotational seismology. This contribution will present the results recently achieved with the SYRTE gyroscope experiment to reach state-of-the-art performances and present the route to applications of this sensor in geosciences.
- Open Access
Accurate trajectory alignment in cold-atom interferometers with separated laser beams
Cold-atom interferometers commonly face systematic effects originating from the coupling between the trajectory of the atomic wave packet and the wave front of the laser beams driving the interferometer. Detrimental for the accuracy and the stability of such inertial sensors, these systematics are particularly enhanced in architectures based on spatially separated laser beams. Here we analyze the effect of a coupling between the relative alignment of two separated laser beams and the trajectory of the atomic wave packet in a four-light-pulse cold-atom gyroscope operated in fountain configuration. We present a method to align the two laser beams at the $0.2 \ \mu$rad level and to determine the optimal mean velocity of the atomic wave packet with an accuracy of $0.2\ \textrm{mm}\cdot\textrm{s}^{-1}$. Such fine tuning constrains the associated gyroscope bias to a level of $1\times 10^{-10}~\textrm{rad}\cdot\textrm{s}^{-1}$. In addition, we reveal this coupling using the point-source interferometry technique by analyzing single-shot time-of-flight fluorescence traces, which allows us to measure large angular misalignments between the interrogation beams. The alignment method which we present here can be employed in other sensor configurations and is particularly relevant to emerging gravitational wave detector concepts based on cold-atom interferometry.Open AccessAccurate trajectory alignment in cold-atom interferometers with separated laser beams
Cold-atom interferometers commonly face systematic effects originating from the coupling between the trajectory of the atomic wave packet and the wave front of the laser beams driving the interferometer. Detrimental for the accuracy and the stability of such inertial sensors, these systematics are particularly enhanced in architectures based on spatially separated laser beams. Here we analyze the effect of a coupling between the relative alignment of two separated laser beams and the trajectory of the atomic wave packet in a four-light-pulse cold-atom gyroscope operated in fountain configuration. We present a method to align the two laser beams at the $0.2 \ \mu$rad level and to determine the optimal mean velocity of the atomic wave packet with an accuracy of $0.2\ \textrm{mm}\cdot\textrm{s}^{-1}$. Such fine tuning constrains the associated gyroscope bias to a level of $1\times 10^{-10}~\textrm{rad}\cdot\textrm{s}^{-1}$. In addition, we reveal this coupling using the point-source interferometry technique by analyzing single-shot time-of-flight fluorescence traces, which allows us to measure large angular misalignments between the interrogation beams. The alignment method which we present here can be employed in other sensor configurations and is particularly relevant to emerging gravitational wave detector concepts based on cold-atom interferometry.