Hidekazu Kaneko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hidekazu Kaneko has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
Shinya S. Suzuki
National Institute of Advanced Industrial Science and Technology (AIST), AIST Tsukuba Central 6, Higashi, Tsukuba, Ibaraki, 305-8566, Japan
14 shared publicationsTakahiro Kawashima
Department of Mechanical Engineering, Toyohashi University of Technology, 1-1 Hibarigaoka Tempaku-cho, Toyohashi, Aichi 441-8580, Japan
12 shared publications- Hiroshi Tamura
Kansai University
7 shared publications - Masatoshi Takita
Center for Neuroscience and Biomedical Engineering, The University of Electro-Communications, Tokyo 182-8585, Japan
7 shared publications Hiroshi Tamura
Osaka University, Suita, Osaka, Japan
6 shared publicationsMotoyuki Akamatsu
Neuroinformatics Laboratory, National Institute of Bioscience and Human Technology, Agency for Industrial Science and Technology, Tsukuba, Japan
6 shared publications
Latest Publications
- Open Access
- 16 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 19 (1) , 107-118
Illusory Pulling Sensation in Older Adults is Associated With Cognitive Function Beyond Somatosensory Sensitivity
Illusory pulling sensations, induced by asymmetric vibrations applied to the fingertips, have attracted attention as a means to investigate sensorimotor processing and develop haptic interfaces. In addition, sensitivity to the illusory pulling sensation tended to decline in some older female participants, suggesting that factors related to aging and/or gender difference may be involved in this phenomenon. In this study, we aimed to clarify the contribution of somatosensory and cognitive functions to the illusory pulling sensation, focusing on aging and gender difference to examine these contributions. Sixty older participants aged 63 to 80 years (30 males, 30 females) completed seven assessments, covering sensitivity to the illusory pulling sensation and a range of somatosensory and cognitive functions from vibration detection thresholds to general cognitive ability assessed by the Mini-Mental State Examination (MMSE). Consistent with prior findings, older females exhibited significantly lower sensitivity to the illusion. Interestingly, although gender differences were observed in some of the assessment items, such as hand length and performance on the parallel-setting task, none of these factors mediated the gender effect on the illusion. While age itself did not have a direct effect on the illusion, an indirect effect was observed through general cognitive function as assessed by the MMSE. These findings suggest that the illusory pulling sensation tends to weaken not only with aging, but also particularly when aging is accompanied by cognitive decline. Overall, gender and cognitive function may play key roles in individual differences in the illusory pulling sensation.
- 16 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 19 (1) , 107-118
Open AccessIllusory Pulling Sensation in Older Adults is Associated With Cognitive Function Beyond Somatosensory Sensitivity
Illusory pulling sensations, induced by asymmetric vibrations applied to the fingertips, have attracted attention as a means to investigate sensorimotor processing and develop haptic interfaces. In addition, sensitivity to the illusory pulling sensation tended to decline in some older female participants, suggesting that factors related to aging and/or gender difference may be involved in this phenomenon. In this study, we aimed to clarify the contribution of somatosensory and cognitive functions to the illusory pulling sensation, focusing on aging and gender difference to examine these contributions. Sixty older participants aged 63 to 80 years (30 males, 30 females) completed seven assessments, covering sensitivity to the illusory pulling sensation and a range of somatosensory and cognitive functions from vibration detection thresholds to general cognitive ability assessed by the Mini-Mental State Examination (MMSE). Consistent with prior findings, older females exhibited significantly lower sensitivity to the illusion. Interestingly, although gender differences were observed in some of the assessment items, such as hand length and performance on the parallel-setting task, none of these factors mediated the gender effect on the illusion. While age itself did not have a direct effect on the illusion, an indirect effect was observed through general cognitive function as assessed by the MMSE. These findings suggest that the illusory pulling sensation tends to weaken not only with aging, but also particularly when aging is accompanied by cognitive decline. Overall, gender and cognitive function may play key roles in individual differences in the illusory pulling sensation.
- Open Access
- 27 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 4294-4303
Forced Movements Facilitate Reversal Learning in Rats: Findings From a Rat Robotic Rehabilitation Model
To evaluate the effectiveness of robotic rehabilitation alone, we developed a robotic rehabilitation model for rats and investigated the effects of inducing forced response-like movements on learning a choice reaction time task. The rats, while in a standing position, initially press two levers with their forepaws. An air-puff stimulation (go-signal: GS) is then applied to either their left or right forepaw. The rats respond by releasing the lever on the correct-response side (correct-RS). If the rats respond incorrectly, a lever-release motion is forcibly induced in the next repeated trial. Combining the lever activation side (correct-RS or incorrect-RS) and its timing (200 ms after GS or just before reaction time (RT)), we formed four experimental groups. The rats with a forepaw sensorimotor cerebral lesion were trained in serial reversal learning of the task, and their performance was compared using the error rate (ER) and RT. The group with incorrect-RS lever activation after GS (iRSaftGS) and the group with correct-RS lever activation before RT (cRSbfrRT) had lower ERs and RTs than the other groups. In addition, both groups showed large improvement in ER at high ER levels but only the iRSaftGS group’s improvement continued at lower ER levels. We conclude that the cRSbfrRT group facilitates only the extinction process and that the iRSaftGS group, which stretches agonistic muscles required for correct motion, is effective in both extinction and acquisition processes. Our findings provide an opportunity to reconsider the strategies for robotic rehabilitation and training.
- 27 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 4294-4303
Open AccessForced Movements Facilitate Reversal Learning in Rats: Findings From a Rat Robotic Rehabilitation Model
To evaluate the effectiveness of robotic rehabilitation alone, we developed a robotic rehabilitation model for rats and investigated the effects of inducing forced response-like movements on learning a choice reaction time task. The rats, while in a standing position, initially press two levers with their forepaws. An air-puff stimulation (go-signal: GS) is then applied to either their left or right forepaw. The rats respond by releasing the lever on the correct-response side (correct-RS). If the rats respond incorrectly, a lever-release motion is forcibly induced in the next repeated trial. Combining the lever activation side (correct-RS or incorrect-RS) and its timing (200 ms after GS or just before reaction time (RT)), we formed four experimental groups. The rats with a forepaw sensorimotor cerebral lesion were trained in serial reversal learning of the task, and their performance was compared using the error rate (ER) and RT. The group with incorrect-RS lever activation after GS (iRSaftGS) and the group with correct-RS lever activation before RT (cRSbfrRT) had lower ERs and RTs than the other groups. In addition, both groups showed large improvement in ER at high ER levels but only the iRSaftGS group’s improvement continued at lower ER levels. We conclude that the cRSbfrRT group facilitates only the extinction process and that the iRSaftGS group, which stretches agonistic muscles required for correct motion, is effective in both extinction and acquisition processes. Our findings provide an opportunity to reconsider the strategies for robotic rehabilitation and training.
- Open Access
- 24 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 1749-1756
Illusory Directional Sensation Induced by Asymmetric Vibrations Influences Sense of Agency and Velocity in Wrist Motions
Illusory directional sensations are generated through asymmetric vibrations applied to the fingertips and have been utilized to induce upper-limb motions in the rehabilitation and training of patients with visual impairment. However, its effects on motor control remain unclear. This study aimed to verify the effects of illusory directional sensations on wrist motion. We conducted objective and subjective evaluations of wrist motion during a motor task, while inducing an illusory directional sensation that was congruent or incongruent with wrist motion. We found that, when motion and illusory directional sensations were congruent, the sense of agency for motion decreased. This indicates an induction sensation of the hand being moved by the illusion. Interestingly, although no physical force was applied to the hand, the angular velocity of the wrist was higher in the congruent condition than that in the no-stimulation condition. The angular velocity of the wrist and electromyography signals of the agonist muscles were weakly positively correlated, suggesting that the participants may have increased their wrist velocity. In other words, the congruence between the direction of motion and illusory directional sensation induced the sensation of the hand being moved, even though the participants’ wrist-motion velocity increased. This phenomenon can be explained by the discrepancy between the sensation of active motion predicted by the efferent copy, and that of actual motion caused by the addition of the illusion. The findings of this study can guide the design of novel rehabilitation methods.
- 24 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 1749-1756
Open AccessIllusory Directional Sensation Induced by Asymmetric Vibrations Influences Sense of Agency and Velocity in Wrist Motions
Illusory directional sensations are generated through asymmetric vibrations applied to the fingertips and have been utilized to induce upper-limb motions in the rehabilitation and training of patients with visual impairment. However, its effects on motor control remain unclear. This study aimed to verify the effects of illusory directional sensations on wrist motion. We conducted objective and subjective evaluations of wrist motion during a motor task, while inducing an illusory directional sensation that was congruent or incongruent with wrist motion. We found that, when motion and illusory directional sensations were congruent, the sense of agency for motion decreased. This indicates an induction sensation of the hand being moved by the illusion. Interestingly, although no physical force was applied to the hand, the angular velocity of the wrist was higher in the congruent condition than that in the no-stimulation condition. The angular velocity of the wrist and electromyography signals of the agonist muscles were weakly positively correlated, suggesting that the participants may have increased their wrist velocity. In other words, the congruence between the direction of motion and illusory directional sensation induced the sensation of the hand being moved, even though the participants’ wrist-motion velocity increased. This phenomenon can be explained by the discrepancy between the sensation of active motion predicted by the efferent copy, and that of actual motion caused by the addition of the illusion. The findings of this study can guide the design of novel rehabilitation methods.
- 1 January 2022
- Published by Elsevier in Behavioural Brain Research
- Vol. 417, 113561
Oral administration of cyclic glycyl-proline facilitates task learning in a rat stroke model
- 1 January 2022
- Published by Elsevier in Behavioural Brain Research
- Vol. 417, 113561
Oral administration of cyclic glycyl-proline facilitates task learning in a rat stroke model
- 11 October 2019
- Published by Wiley in Journal of Texture Studies
- Vol. 51 (3) , 389-397
A pseudo‐mastication sound presentation device to improve the texture of nursing care foods
The texture of foods is affected by concurrent auditory sensations. To improve the texture of nursing care foods, we developed a pseudo‐mastication sound presentation device based on electromyogram (EMG) signals from the muscles of mastication. EMG signals have enabled us to promptly present care recipients with pseudo‐mastication sounds. However, actual mastication sounds vary in intensity and duration more than EMG signals. Here, we investigated changes in EMG signals and actual mastication sounds during the mastication of two food types (rice crackers and Japanese pickles) to improve our device. We found that the intensity and duration of mastication sounds decreased as the number of mastication strokes increased. Furthermore, the intensity and duration of mastication sounds and the latency between the onset of EMG signals and the onset of mastication sounds also varied by food type. For EMG signals, only the intensity varied by food type. Based on our findings, we modified our pseudo‐mastication sound presentation device to enable control of the intensity and duration of pseudo‐mastication sounds based on the number of mastication strokes and food type. Reproducing more natural pseudo‐mastication sounds can improve care recipients’ motivation for ingesting nursing care foods, thus preventing malnutrition and frailty.
- 11 October 2019
- Published by Wiley in Journal of Texture Studies
- Vol. 51 (3) , 389-397
A pseudo‐mastication sound presentation device to improve the texture of nursing care foods
The texture of foods is affected by concurrent auditory sensations. To improve the texture of nursing care foods, we developed a pseudo‐mastication sound presentation device based on electromyogram (EMG) signals from the muscles of mastication. EMG signals have enabled us to promptly present care recipients with pseudo‐mastication sounds. However, actual mastication sounds vary in intensity and duration more than EMG signals. Here, we investigated changes in EMG signals and actual mastication sounds during the mastication of two food types (rice crackers and Japanese pickles) to improve our device. We found that the intensity and duration of mastication sounds decreased as the number of mastication strokes increased. Furthermore, the intensity and duration of mastication sounds and the latency between the onset of EMG signals and the onset of mastication sounds also varied by food type. For EMG signals, only the intensity varied by food type. Based on our findings, we modified our pseudo‐mastication sound presentation device to enable control of the intensity and duration of pseudo‐mastication sounds based on the number of mastication strokes and food type. Reproducing more natural pseudo‐mastication sounds can improve care recipients’ motivation for ingesting nursing care foods, thus preventing malnutrition and frailty.
- 15 March 2017
- Published by Fuji Technology Press Ltd. in Journal of Advanced Computational Intelligence and Intelligent Informatics
- Vol. 21 (2) , 342-349
An Attempt to Improve Food/Sound Congruity Using an Electromyogram Pseudo-Chewing Sound Presentation System
Title: An Attempt to Improve Food/Sound Congruity Using an Electromyogram Pseudo-Chewing Sound Presentation System | Keywords: chewing sound, food texture, food/sound congruity, electromyography, elderly person | Author: Hiroshi Endo, Hidekazu Kaneko, Shuichi Ino, and Waka Fujisaki
- 15 March 2017
- Published by Fuji Technology Press Ltd. in Journal of Advanced Computational Intelligence and Intelligent Informatics
- Vol. 21 (2) , 342-349
An Attempt to Improve Food/Sound Congruity Using an Electromyogram Pseudo-Chewing Sound Presentation System
Title: An Attempt to Improve Food/Sound Congruity Using an Electromyogram Pseudo-Chewing Sound Presentation System | Keywords: chewing sound, food texture, food/sound congruity, electromyography, elderly person | Author: Hiroshi Endo, Hidekazu Kaneko, Shuichi Ino, and Waka Fujisaki
- Open Access
- 14 January 2017
- Published by Springer Nature in Learning & Behavior
- Vol. 45 (2) , 191-204
Effects of forced movements on learning: Findings from a choice reaction time task in rats
To investigate how motor sensation facilitates learning, we used a sensory–motor association task to determine whether the sensation induced by force
- 14 January 2017
- Published by Springer Nature in Learning & Behavior
- Vol. 45 (2) , 191-204
Open AccessEffects of forced movements on learning: Findings from a choice reaction time task in rats
To investigate how motor sensation facilitates learning, we used a sensory–motor association task to determine whether the sensation induced by force
- Open Access
- 15 June 2014
- Published by American Physiological Society in Journal of Neurophysiology
- Vol. 111 (12) , 2589-2602
Organization of local horizontal functional interactions between neurons in the inferior temporal cortex of macaque monkeys
Detailed knowledge of neuronal circuitry is necessary for understanding the mechanisms underlying information processing in the brain. We investigated the organization of horizontal functional interactions in the inferior temporal cortex of macaque monkeys, which plays important roles in visual object recognition. Neuronal activity was recorded from the inferior temporal cortex using an array of eight tetrodes, with spatial separation between paired neurons up to 1.4 mm. We evaluated functional interactions on a time scale of milliseconds using cross-correlation analysis of neuronal activity of the paired neurons. Visual response properties of neurons were evaluated using responses to a set of 100 visual stimuli. Adjacent neuron pairs tended to show strong functional interactions compared with more distant neuron pairs, and neurons with similar stimulus preferences tended to show stronger functional interactions than neurons with different stimulus preferences. Thus horizontal functional interactions in the inferior temporal cortex appear to be organized according to both cortical distances and similarity in stimulus preference between neurons. Furthermore, the relationship between strength of functional interactions and similarity in stimulus preference observed in distant neuron pairs was more prominent than in adjacent pairs. The results suggest that functional circuitry is specifically organized, depending on the horizontal distances between neurons. Such specificity endows each circuit with unique functions.
- 15 June 2014
- Published by American Physiological Society in Journal of Neurophysiology
- Vol. 111 (12) , 2589-2602
Open AccessOrganization of local horizontal functional interactions between neurons in the inferior temporal cortex of macaque monkeys
Detailed knowledge of neuronal circuitry is necessary for understanding the mechanisms underlying information processing in the brain. We investigated the organization of horizontal functional interactions in the inferior temporal cortex of macaque monkeys, which plays important roles in visual object recognition. Neuronal activity was recorded from the inferior temporal cortex using an array of eight tetrodes, with spatial separation between paired neurons up to 1.4 mm. We evaluated functional interactions on a time scale of milliseconds using cross-correlation analysis of neuronal activity of the paired neurons. Visual response properties of neurons were evaluated using responses to a set of 100 visual stimuli. Adjacent neuron pairs tended to show strong functional interactions compared with more distant neuron pairs, and neurons with similar stimulus preferences tended to show stronger functional interactions than neurons with different stimulus preferences. Thus horizontal functional interactions in the inferior temporal cortex appear to be organized according to both cortical distances and similarity in stimulus preference between neurons. Furthermore, the relationship between strength of functional interactions and similarity in stimulus preference observed in distant neuron pairs was more prominent than in adjacent pairs. The results suggest that functional circuitry is specifically organized, depending on the horizontal distances between neurons. Such specificity endows each circuit with unique functions.
- Open Access
- 2 May 2014
- Published by Springer Nature in Scientific Reports
- Vol. 4 (1) , 4868
In vivo neuronal action potential recordings via three-dimensional microscale needle-electrode arrays
Very fine needle-electrode arrays potentially offer both low invasiveness and high spatial resolution of electrophysiological neuronal recordings in vivo. Herein we report the penetrating and recording capabilities of silicon-growth-based three-dimensional microscale-diameter needle-electrodes arrays. The fabricated needles exhibit a circular-cone shape with a 3-[mgr]m-diameter tip and a 210-[mgr]m length. Due to the microscale diameter, our silicon needles are more flexible than other microfabricated silicon needles with larger diameters. Coating the microscale-needle-tip with platinum black results in an impedance of ~600[emsp14]k[OHgr] in saline with output/input signal amplitude ratios of more than 90% at 40[emsp14]Hz-10[emsp14]kHz. The needles can penetrate into the whisker barrel area of a rat's cerebral cortex, and the action potentials recorded from some neurons exhibit peak-to-peak amplitudes of ~300[emsp14][mgr]Vpp. These results demonstrate the feasibility of in vivo neuronal action potential recordings with a microscale needle-electrode array fabricated using silicon growth technology.
- 2 May 2014
- Published by Springer Nature in Scientific Reports
- Vol. 4 (1) , 4868
Open AccessIn vivo neuronal action potential recordings via three-dimensional microscale needle-electrode arrays
Very fine needle-electrode arrays potentially offer both low invasiveness and high spatial resolution of electrophysiological neuronal recordings in vivo. Herein we report the penetrating and recording capabilities of silicon-growth-based three-dimensional microscale-diameter needle-electrodes arrays. The fabricated needles exhibit a circular-cone shape with a 3-[mgr]m-diameter tip and a 210-[mgr]m length. Due to the microscale diameter, our silicon needles are more flexible than other microfabricated silicon needles with larger diameters. Coating the microscale-needle-tip with platinum black results in an impedance of ~600[emsp14]k[OHgr] in saline with output/input signal amplitude ratios of more than 90% at 40[emsp14]Hz-10[emsp14]kHz. The needles can penetrate into the whisker barrel area of a rat's cerebral cortex, and the action potentials recorded from some neurons exhibit peak-to-peak amplitudes of ~300[emsp14][mgr]Vpp. These results demonstrate the feasibility of in vivo neuronal action potential recordings with a microscale needle-electrode array fabricated using silicon growth technology.
- 1 January 2013
- Published by Japanese Society for Medical and Biological Engineering in Advanced Biomedical Engineering
- Vol. 2, 72-79
Facilitation of Learning and Rehabilitation in Rats by Inducing Response-like Movement
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 1 January 2013
- Published by Japanese Society for Medical and Biological Engineering in Advanced Biomedical Engineering
- Vol. 2, 72-79
Facilitation of Learning and Rehabilitation in Rats by Inducing Response-like Movement
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies