Andreas Pettersson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andreas Pettersson has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Karin Näsström
Associate Professor and Head, Department of Dental Medicine, Division of Image and Functional Odontology, Karolinska Institute, Huddinge, Sweden
5 shared publicationsLuc Gillot
Part-time Lecturer, Faculty of Odontology, University Paris-Descartes, France
3 shared publications- Rikard Söderberg
Chalmers University of Technology
3 shared publications Bernard Cannas
Clinical Instructor, Laboratory of Anatomy, Odontological Faculty, University Paris Descartes, Descartes, Paris, France
2 shared publications- Björn Klinge
Faculty of Odontology Malmö University Malmö Sweden
2 shared publications Jenny Fäldt
Senior Scientist, Division of Early Development, Nobel Biocare AB, Göteborg, Sweden
2 shared publications
Latest Publications
- 1 December 2014
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 112 (6) , 1472-1478
Accuracy of virtually planned and CAD/CAM-guided implant surgery on plastic models
- 1 December 2014
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 112 (6) , 1472-1478
Accuracy of virtually planned and CAD/CAM-guided implant surgery on plastic models
- 1 October 2014
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 112 (4) , 798-804
Accuracy of virtually planned and conventionally placed implants in edentulous cadaver maxillae and mandibles: A preliminary report
- 1 October 2014
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 112 (4) , 798-804
Accuracy of virtually planned and conventionally placed implants in edentulous cadaver maxillae and mandibles: A preliminary report
- 1 September 2014
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 112 (3) , 526-532
Accuracy of implant placement in the posterior maxilla as related to 2 types of surgical guides: A pilot study in the human cadaver
- 1 September 2014
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 112 (3) , 526-532
Accuracy of implant placement in the posterior maxilla as related to 2 types of surgical guides: A pilot study in the human cadaver
- 1 August 2012
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 14 (4) , 527-537
Accuracy of Virtually Planned and Template Guided Implant Surgery on Edentate Patients
Purpose: Scientific evidence regarding the accuracy of implants placed into patients by the aid of a surgical template is limited. The objective of the present study was to verify if any variation exists between virtually planned implants' position using a computer, compared with the subsequently clinically placed implants with the aid of a surgical template in the mandible and the maxilla.Material and Methods: A total number of 25 edentate jaws were treated with the aid of a surgical template. In total, 139 implants were inserted. Fifty implants were inserted in the mandible and 89 in the maxilla. A voxel‐based registration method was used to match two separate cone‐beam computed tomography scans of the patients. The implant positions were calculated and compared between the planned implants and the implants' clinical position after more than 1 year after surgery. The results included the linear differences in distance at the level of the hex, the apex, and the depth. The angular differences were presented in degrees.Results: Statistical results indicated some factors with significant deviations. The greatest errors were found when comparing between patients moving during the computed tomography scans and those that did not move. The results showed significant divergence at the level of the hex and apex of the implants.Conclusion: The hypothesis was rejected, as the statistical results indicated that there were significant differences between virtually planned implants' position and the final position of implants placed clinically.
- 1 August 2012
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 14 (4) , 527-537
Accuracy of Virtually Planned and Template Guided Implant Surgery on Edentate Patients
Purpose: Scientific evidence regarding the accuracy of implants placed into patients by the aid of a surgical template is limited. The objective of the present study was to verify if any variation exists between virtually planned implants' position using a computer, compared with the subsequently clinically placed implants with the aid of a surgical template in the mandible and the maxilla.Material and Methods: A total number of 25 edentate jaws were treated with the aid of a surgical template. In total, 139 implants were inserted. Fifty implants were inserted in the mandible and 89 in the maxilla. A voxel‐based registration method was used to match two separate cone‐beam computed tomography scans of the patients. The implant positions were calculated and compared between the planned implants and the implants' clinical position after more than 1 year after surgery. The results included the linear differences in distance at the level of the hex, the apex, and the depth. The angular differences were presented in degrees.Results: Statistical results indicated some factors with significant deviations. The greatest errors were found when comparing between patients moving during the computed tomography scans and those that did not move. The results showed significant divergence at the level of the hex and apex of the implants.Conclusion: The hypothesis was rejected, as the statistical results indicated that there were significant differences between virtually planned implants' position and the final position of implants placed clinically.
- 31 December 2011
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 106 (6) , 346-349
A single appointment protocol to create a partially edentulous CAD/CAM guided surgical template: A clinical report
- 31 December 2011
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 106 (6) , 346-349
A single appointment protocol to create a partially edentulous CAD/CAM guided surgical template: A clinical report
- 27 September 2010
- Published by Wiley in Clinical Oral Implants Research
- Vol. 22 (3) , 308-313
Virtually planned and template-guided implant surgery: an experimental model matching approach
The objective of this study was to assess positional deviations between the implant replicas in the pre-operative plaster model created from a computer-aided design/computer-aided manufacturing (CAD/CAM) surgical template and the implant replicas in the post-operative plaster model that was made from patients' impressions taken at ≥1-year follow-up. One hundred and thirty-nine implants were inserted in 25 edentulous jaws using Nobel Guide(™). Plaster models containing the implant replicas, one created from the surgical template before surgery and the other created from patients' impressions at ≥1-year follow-up, were scanned using a measuring device. Implant positions were matched with the best-fit alignment. Deviation was calculated at the level of the hex and the apex. The results were compared with a computed tomography matching study. Data were analysed using the paired t-test (α=0.05). There were positional deviations of implant replicas between pre- and post-operative plaster models both at the hex and the apex. The geometric mean of the deviation at the apex was 0.59 mm in the maxilla and 0.4 mm in the mandible. At the hex, it was 0.59 mm in the maxilla and 0.39 mm in the mandible. Statistically significant differences were observed in positions between the implant replicas in the pre-operative plaster models created from a CAD/CAM surgical template and the implant replicas in the post-operative plaster models that were made from patients' impressions taken at ≥1-year follow-up. Due to the lack of reference objects in the pre- and post-operative working casts, additional refinements are required in order to validate the impression matching method and recommend the method to be used.
- 27 September 2010
- Published by Wiley in Clinical Oral Implants Research
- Vol. 22 (3) , 308-313
Virtually planned and template-guided implant surgery: an experimental model matching approach
The objective of this study was to assess positional deviations between the implant replicas in the pre-operative plaster model created from a computer-aided design/computer-aided manufacturing (CAD/CAM) surgical template and the implant replicas in the post-operative plaster model that was made from patients' impressions taken at ≥1-year follow-up. One hundred and thirty-nine implants were inserted in 25 edentulous jaws using Nobel Guide(™). Plaster models containing the implant replicas, one created from the surgical template before surgery and the other created from patients' impressions at ≥1-year follow-up, were scanned using a measuring device. Implant positions were matched with the best-fit alignment. Deviation was calculated at the level of the hex and the apex. The results were compared with a computed tomography matching study. Data were analysed using the paired t-test (α=0.05). There were positional deviations of implant replicas between pre- and post-operative plaster models both at the hex and the apex. The geometric mean of the deviation at the apex was 0.59 mm in the maxilla and 0.4 mm in the mandible. At the hex, it was 0.59 mm in the maxilla and 0.39 mm in the mandible. Statistically significant differences were observed in positions between the implant replicas in the pre-operative plaster models created from a CAD/CAM surgical template and the implant replicas in the post-operative plaster models that were made from patients' impressions taken at ≥1-year follow-up. Due to the lack of reference objects in the pre- and post-operative working casts, additional refinements are required in order to validate the impression matching method and recommend the method to be used.
- 1 July 2010
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 104 (1) , 48-55
Virtual variation simulation of CAD/CAM template-guided surgeries performed on human cadavers: Part II
- 1 July 2010
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 104 (1) , 48-55
Virtual variation simulation of CAD/CAM template-guided surgeries performed on human cadavers: Part II
- 1 June 2010
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 103 (6) , 334-342
Accuracy of CAD/CAM-guided surgical template implant surgery on human cadavers: Part I
- 1 June 2010
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 103 (6) , 334-342
Accuracy of CAD/CAM-guided surgical template implant surgery on human cadavers: Part I
- Top Cited Papers
- 1 June 2005
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 7 (s1) , s111-s120
A Computed Tomographic Scan–Derived Customized Surgical Template and Fixed Prosthesis for Flapless Surgery and Immediate Loading of Implants in Fully Edentulous Maxillae: A Prospective Multicenter Study
Background: Based on three‐dimensional implant planning software for computed tomographic (CT) scan data, customized surgical templates and final dental prostheses could be designed to ensure high precision transfer of the implant treatment planning to the operative field and an immediate rigid splinting of the installed implants, respectively.Purpose: The aim of the present study was to (1) evaluate a concept including a treatment planning procedure based on CT scan images and a prefabricated fixed prosthetic reconstruction for immediate function in upper jaws using a flapless surgical technique and (2) validate the universality of this concept in a prospective multicenter clinical study.Materials and Methods: Twenty‐seven consecutive patients with edentulous maxillae were included. Treatments were performed according to the Teeth‐in‐an‐Hour™ concept (Nobel Biocare AB, Göteborg, Sweden), which includes a CT scan‐derived customized surgical template for flapless surgery and a prefabricated prosthetic suprastructure.Results: All patients received their final prosthetic restoration immediately after implant placement, that is, both the surgery and the prosthesis insertion were completed within approximately 1 hour. In the 24 patients followed for 1 year, all prostheses and individual implants were recorded as stable.Conclusion: The present prospective multicenter study indicates that the prefabrication, on the basis of models derived from three‐dimensional oral implant planning software, of both surgical templates for flapless surgery and dental pros‐theses for immediate loading is a very reliable treatment option. It is evident that the same approach could be used for staged surgery and in partial edentulism.
- 1 June 2005
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 7 (s1) , s111-s120
Top Cited PapersA Computed Tomographic Scan–Derived Customized Surgical Template and Fixed Prosthesis for Flapless Surgery and Immediate Loading of Implants in Fully Edentulous Maxillae: A Prospective Multicenter Study
Background: Based on three‐dimensional implant planning software for computed tomographic (CT) scan data, customized surgical templates and final dental prostheses could be designed to ensure high precision transfer of the implant treatment planning to the operative field and an immediate rigid splinting of the installed implants, respectively.Purpose: The aim of the present study was to (1) evaluate a concept including a treatment planning procedure based on CT scan images and a prefabricated fixed prosthetic reconstruction for immediate function in upper jaws using a flapless surgical technique and (2) validate the universality of this concept in a prospective multicenter clinical study.Materials and Methods: Twenty‐seven consecutive patients with edentulous maxillae were included. Treatments were performed according to the Teeth‐in‐an‐Hour™ concept (Nobel Biocare AB, Göteborg, Sweden), which includes a CT scan‐derived customized surgical template for flapless surgery and a prefabricated prosthetic suprastructure.Results: All patients received their final prosthetic restoration immediately after implant placement, that is, both the surgery and the prosthesis insertion were completed within approximately 1 hour. In the 24 patients followed for 1 year, all prostheses and individual implants were recorded as stable.Conclusion: The present prospective multicenter study indicates that the prefabrication, on the basis of models derived from three‐dimensional oral implant planning software, of both surgical templates for flapless surgery and dental pros‐theses for immediate loading is a very reliable treatment option. It is evident that the same approach could be used for staged surgery and in partial edentulism.