Anand Lodha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anand Lodha has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Shobhana Karuveettil Menon
Department of Forensic Science, School of Sciences, Gujarat University, Ahmedabad, India
14 shared publications - Alok Pandya
School of Biotechnology and Bioengineering Institute of Advanced Research Gandhinagar Gujarat 382426 India
12 shared publications Pinkesh G. Sutariya
Bhavans Shree I. L. Pandya Arts-Science College, India
7 shared publications- Niha Ansari
Department of Forensic Science, School of Sciences, Gujarat University, Ahmedabad, India
5 shared publications Heena Goswami
Department of Science and technology, Gujarat National Law University, Gandhinagar, Gujarat, India
3 shared publicationsM.V. Rao
Department of Zoology, Gujarat University, Ahmedabad 380009, India
2 shared publications
Latest Publications
- 22 March 2020
- Published by Taylor & Francis in Australian Journal of Forensic Sciences
- Vol. 53 (4) , 407-418
A portable microfluidic paper-based analytical device for blood detection and typing assay
We developed a portable device for blood detection as well as blood typing assay, using a microfluidic paper-based analytical devices (µPADs) which proves to be sensitive, cost-effective, user-friendly and field-appropriate. A different patterned µPAD was fabricated using wax and a laser printer for detection of blood and ABO and Rh blood typing. Five different blood detection tests and two blood typing systems, i.e. ABO and Rh, were performed within minutes without following any complex protocol and were simple to infer. The performance of this hand-held μPAD proves it to be a reliable alternative to lab-based tests, at a fraction of the cost and with simplicity. The developed μPAD provides on-site blood detection as well as blood typing, which proves to be a reasonable and very useful add-on to conventional forensic and clinical investigations.
- 22 March 2020
- Published by Taylor & Francis in Australian Journal of Forensic Sciences
- Vol. 53 (4) , 407-418
A portable microfluidic paper-based analytical device for blood detection and typing assay
We developed a portable device for blood detection as well as blood typing assay, using a microfluidic paper-based analytical devices (µPADs) which proves to be sensitive, cost-effective, user-friendly and field-appropriate. A different patterned µPAD was fabricated using wax and a laser printer for detection of blood and ABO and Rh blood typing. Five different blood detection tests and two blood typing systems, i.e. ABO and Rh, were performed within minutes without following any complex protocol and were simple to infer. The performance of this hand-held μPAD proves it to be a reliable alternative to lab-based tests, at a fraction of the cost and with simplicity. The developed μPAD provides on-site blood detection as well as blood typing, which proves to be a reasonable and very useful add-on to conventional forensic and clinical investigations.
- 19 September 2017
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 9 (38) , 5632-5639
Determination of cause of death using paper-based microfluidic device as a colorimetric probe
In recent years, the use of benzodiazepines has increased in the commission of crime, homicide, suicide, drugs overdoses, robbery, and drug-facilitated sexual assault. Assessment of drug exposure is also costly and resource-intensive because the analysis typically requires sophisticated instrumental techniques. Hence, driven by the need to detect alprazolam (ALP), we report a novel, simple, portable, disposable, and rapid inexpensive microfluidic paper-based analytical device (μPAD) for measuring ALP from vitreous humor and blood. This μPAD is embedded with silver nanoparticles for colorimetric detection and rapid quantification of alprazolam in different biological fluids using a smart phone. Under optimal conditions, the limit of detection is found to be 0.8 ng mL−1via a UV-vis spectrophotometer, whereas the limit of μPAD-based smart phone-enabled ALP detection is 10 ng mL−1. This μPAD was successfully applied to drug-exposed real samples of blood and vitreous humor. The proposed method provides mix and measure detection platform using a test paper and smart phone, which offers a new alternative for on-site detection especially in field situations of drugs in forensic cases and as point of care (POC) device for clinical diagnosis for toxicological drug screening. The device formed herein meets the criteria of the present-generation analytical devices in terms of portability, selectivity, sensitivity at the ng mL−1 level, cost effectiveness, simplicity, data transmission facility, and rapid on-site investigation.
- 19 September 2017
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 9 (38) , 5632-5639
Determination of cause of death using paper-based microfluidic device as a colorimetric probe
In recent years, the use of benzodiazepines has increased in the commission of crime, homicide, suicide, drugs overdoses, robbery, and drug-facilitated sexual assault. Assessment of drug exposure is also costly and resource-intensive because the analysis typically requires sophisticated instrumental techniques. Hence, driven by the need to detect alprazolam (ALP), we report a novel, simple, portable, disposable, and rapid inexpensive microfluidic paper-based analytical device (μPAD) for measuring ALP from vitreous humor and blood. This μPAD is embedded with silver nanoparticles for colorimetric detection and rapid quantification of alprazolam in different biological fluids using a smart phone. Under optimal conditions, the limit of detection is found to be 0.8 ng mL−1via a UV-vis spectrophotometer, whereas the limit of μPAD-based smart phone-enabled ALP detection is 10 ng mL−1. This μPAD was successfully applied to drug-exposed real samples of blood and vitreous humor. The proposed method provides mix and measure detection platform using a test paper and smart phone, which offers a new alternative for on-site detection especially in field situations of drugs in forensic cases and as point of care (POC) device for clinical diagnosis for toxicological drug screening. The device formed herein meets the criteria of the present-generation analytical devices in terms of portability, selectivity, sensitivity at the ng mL−1 level, cost effectiveness, simplicity, data transmission facility, and rapid on-site investigation.
- 4 April 2017
- Published by Taylor & Francis in Australian Journal of Forensic Sciences
- Vol. 51 (1) , 78-94
A real-time smartphone-enabled time since death estimation from vitreous humour protein
This study reports on a smartphone-based application for the determination of time since death (TSD) from vitreous humour (VH) protein via recognition and quantification using a simple biuret method for on-the-spot analysis. In basic pH, in the presence of protein, the biuret reagent forms a protein-biuret complex resulting in a colour change that is measurable using a UV-vis spectrophotometer. The limit of detection (LOD) for Bovine serum albumin (BSA) was found to be 8 μg/ml and the limit of quantification (LOQ) was found to be 10 μg/ml. The developed method was further validated and applied for TSD determination from VH samples in the range of 3–60 h. The results showed that there is a linear correlation between the VH protein concentration and TSD, as the protein concentration decreases up to 60 h, with the equation TSD = 33.72 + (–0.27) × concentration. Further, in the present study smart approach was applied for the TSD determination. The results obtained showed that the current method proves to have a great utility up to 60 h. The linear regression equation between TSD and RGB (red, green and blue) intensities of protein concentration tup to 60 h ± 4.5 h was found to be TSD = 6.27E2+1.41*RGB intensity. The proposed method provides a smart, rapid and sensitive, as well as cost effective, TSD determination via VH protein.
- 4 April 2017
- Published by Taylor & Francis in Australian Journal of Forensic Sciences
- Vol. 51 (1) , 78-94
A real-time smartphone-enabled time since death estimation from vitreous humour protein
This study reports on a smartphone-based application for the determination of time since death (TSD) from vitreous humour (VH) protein via recognition and quantification using a simple biuret method for on-the-spot analysis. In basic pH, in the presence of protein, the biuret reagent forms a protein-biuret complex resulting in a colour change that is measurable using a UV-vis spectrophotometer. The limit of detection (LOD) for Bovine serum albumin (BSA) was found to be 8 μg/ml and the limit of quantification (LOQ) was found to be 10 μg/ml. The developed method was further validated and applied for TSD determination from VH samples in the range of 3–60 h. The results showed that there is a linear correlation between the VH protein concentration and TSD, as the protein concentration decreases up to 60 h, with the equation TSD = 33.72 + (–0.27) × concentration. Further, in the present study smart approach was applied for the TSD determination. The results obtained showed that the current method proves to have a great utility up to 60 h. The linear regression equation between TSD and RGB (red, green and blue) intensities of protein concentration tup to 60 h ± 4.5 h was found to be TSD = 6.27E2+1.41*RGB intensity. The proposed method provides a smart, rapid and sensitive, as well as cost effective, TSD determination via VH protein.
- 1 January 2017
- Published by ScopeMed in European Journal of Forensic Sciences
- Vol. 4 (2) , 1
Stature Estimation from Footprint: A Study on Central Indian Population
- 1 January 2017
- Published by ScopeMed in European Journal of Forensic Sciences
- Vol. 4 (2) , 1
Stature Estimation from Footprint: A Study on Central Indian Population
- 1 January 2017
- Published by Elsevier in Forensic Science International
- Vol. 270, 146-152
Isolation of PCR ready-human DNA using copper nanoparticles from skeletal remains
- 1 January 2017
- Published by Elsevier in Forensic Science International
- Vol. 270, 146-152
Isolation of PCR ready-human DNA using copper nanoparticles from skeletal remains
- 1 December 2016
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 86, 115-121
Smart platform for the time since death determination from vitreous humor cystine
- 1 December 2016
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 86, 115-121
Smart platform for the time since death determination from vitreous humor cystine
- Open Access
- 1 June 2016
- Published by Springer Nature in Egyptian Journal of Forensic Sciences
- Vol. 6 (2) , 126-134
Facial soft tissue thickness database of Gujarati population for forensic craniofacial reconstruction
- 1 June 2016
- Published by Springer Nature in Egyptian Journal of Forensic Sciences
- Vol. 6 (2) , 126-134
Open AccessFacial soft tissue thickness database of Gujarati population for forensic craniofacial reconstruction
- 14 December 2015
- Published by Taylor & Francis in Australian Journal of Forensic Sciences
- Vol. 49 (1) , 22-30
Novel approach to determine post-mortem interval from ATPase activity
A recurring problem in forensic medicine is the need to fix the time of death within the limits of probability. Errors in overestimating and underestimating the post-mortem interval based on body cooling is common. Post-mortem biochemistry has become a potent additional procedure in forensic death investigation. However, in our experiment, to determine the post-mortem interval we investigated the ATPase activity. The investigation was performed on the liver tissue of 25 corpses (21 men and four women) of age ranging between 40–60 years. The study of ATPase enzymatic activity shows that there is a considerable drop in the levels of ATPase activity with increasing post-mortem interval up to 24 h and this is one of the most reliable methods for estimating time of death.
- 14 December 2015
- Published by Taylor & Francis in Australian Journal of Forensic Sciences
- Vol. 49 (1) , 22-30
Novel approach to determine post-mortem interval from ATPase activity
A recurring problem in forensic medicine is the need to fix the time of death within the limits of probability. Errors in overestimating and underestimating the post-mortem interval based on body cooling is common. Post-mortem biochemistry has become a potent additional procedure in forensic death investigation. However, in our experiment, to determine the post-mortem interval we investigated the ATPase activity. The investigation was performed on the liver tissue of 25 corpses (21 men and four women) of age ranging between 40–60 years. The study of ATPase enzymatic activity shows that there is a considerable drop in the levels of ATPase activity with increasing post-mortem interval up to 24 h and this is one of the most reliable methods for estimating time of death.
- 11 September 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (21) , 9084-9091
Lab-on-phone citrate-capped silver nanosensor for lidocaine hydrochloride detection from a biological matrix
In the present investigation, we applied the application potential of nanomaterials and smartphone analysis to develop a specific, sensitive and portable method. In this study, we report a silver nanoparticles-based colorimetric nanosensor for the determination of lidocaine hydrochloride (LHC) up to 0.05 ng mL−1 with good linear correlation in the range from 0.1 to 4.5 ng mL−1 with a correlation coefficient of 0.9914. Coexisting substances, including acetaminophen, diazepam, nitrazepam, lorazepam, zolpidem, atropine, bupivacaine, clonazepam and morphine did not interfere in the determination of LHC. The developed sensor proved to be a smart alternative lab-on-phone device, which would help in the on-the-spot determination of LHC in forensic toxicological drug screening. Herein, we utilized easily accessible vitreous humor, which is often unnoticed for toxicological drug screening along with blood for real sample analysis.
- 11 September 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (21) , 9084-9091
Lab-on-phone citrate-capped silver nanosensor for lidocaine hydrochloride detection from a biological matrix
In the present investigation, we applied the application potential of nanomaterials and smartphone analysis to develop a specific, sensitive and portable method. In this study, we report a silver nanoparticles-based colorimetric nanosensor for the determination of lidocaine hydrochloride (LHC) up to 0.05 ng mL−1 with good linear correlation in the range from 0.1 to 4.5 ng mL−1 with a correlation coefficient of 0.9914. Coexisting substances, including acetaminophen, diazepam, nitrazepam, lorazepam, zolpidem, atropine, bupivacaine, clonazepam and morphine did not interfere in the determination of LHC. The developed sensor proved to be a smart alternative lab-on-phone device, which would help in the on-the-spot determination of LHC in forensic toxicological drug screening. Herein, we utilized easily accessible vitreous humor, which is often unnoticed for toxicological drug screening along with blood for real sample analysis.