Radek Prochazka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Radek Prochazka has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Jan Hlavacek
Faculty of Electrical Engineering, Czech Technical University in Prague, Czech Republic
9 shared publications Martin Knenicky
Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic
9 shared publicationsKarel Draxler
Czech Technical University in Prague, Department of Measurement, Prague, Czech Republic
6 shared publicationsRenata Styblikova
Czech Metrology Institute, Department of Electromagnetic Quantities, Brno, Czech Republic
5 shared publicationsOndrej Sefl
Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic
2 shared publications- Ondřej Šefl
Institute for Power Systems and High Voltage Technology, ETH Zurich, 8092 Zurich, Switzerland
2 shared publications
Latest Publications
- 2 September 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Lightning geolocation accuracy as the dominant error source in evaluating strike-prediction models for transmission lines
- 2 September 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Lightning geolocation accuracy as the dominant error source in evaluating strike-prediction models for transmission lines
- Open Access
- 2 June 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 364
Dispatch optimization and sizing of molten-salt power-to-heat systems in balancing electricity markets for industrial heat electrification
- 2 June 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 364
Open AccessDispatch optimization and sizing of molten-salt power-to-heat systems in balancing electricity markets for industrial heat electrification
- 30 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 16 (4) , 645-654
Development of Piezoelectric Polymer Composites for Stereolithography
This study focused on the preparation and characterization of piezoelectric composite materials fabricated using stereolithography (SLA) 3D printing. The composite material was developed by incorporating lead zirconate titanate (PZT) ceramic powder into a commercial photopolymer resin. The preparation process was optimized through ultrasonic mixing, careful adjustment of printing parameters—such as layer exposure time and thickness—and refinement of post-processing conditions. The maximum filler content successfully achieved was 35 wt.%, as higher concentrations caused difficulties in printability and proper dispersion. The addition of the piezoelectric ceramic filler significantly affected the dielectric properties of the resin - the relative permittivity doubled its original value. At the same time, tensile strength decreased with increasing filler content, with the 15 wt.% composite showing about a 35 % reduction in tensile strength compared to pure resin. Despite using a deliberately simple formulation—without dispersants, binders, or other additives—the composites achieved a piezoelectric charge coefficient (d₃₃) of up to 1.39 pC/N. Additionally, this work explored different polarization techniques, including variations in electrode geometry, polarization duration, and electric field strength, supported by numerical simulations to assess field distribution. By optimizing these factors within a straightforward fabrication approach, this study demonstrates that functional piezoelectric properties can be integrated into SLA-printed parts, contributing valuable knowledge for future development of energy harvesters, sensors, and smart device applications.
- 30 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 16 (4) , 645-654
Development of Piezoelectric Polymer Composites for Stereolithography
This study focused on the preparation and characterization of piezoelectric composite materials fabricated using stereolithography (SLA) 3D printing. The composite material was developed by incorporating lead zirconate titanate (PZT) ceramic powder into a commercial photopolymer resin. The preparation process was optimized through ultrasonic mixing, careful adjustment of printing parameters—such as layer exposure time and thickness—and refinement of post-processing conditions. The maximum filler content successfully achieved was 35 wt.%, as higher concentrations caused difficulties in printability and proper dispersion. The addition of the piezoelectric ceramic filler significantly affected the dielectric properties of the resin - the relative permittivity doubled its original value. At the same time, tensile strength decreased with increasing filler content, with the 15 wt.% composite showing about a 35 % reduction in tensile strength compared to pure resin. Despite using a deliberately simple formulation—without dispersants, binders, or other additives—the composites achieved a piezoelectric charge coefficient (d₃₃) of up to 1.39 pC/N. Additionally, this work explored different polarization techniques, including variations in electrode geometry, polarization duration, and electric field strength, supported by numerical simulations to assess field distribution. By optimizing these factors within a straightforward fabrication approach, this study demonstrates that functional piezoelectric properties can be integrated into SLA-printed parts, contributing valuable knowledge for future development of energy harvesters, sensors, and smart device applications.
- 22 July 2025
- Published by Elsevier in Ceramics International
- Vol. 51 (25) , 45542-45554
Characterization of BTO ceramic composite photocurable resin for dielectric applications
- 22 July 2025
- Published by Elsevier in Ceramics International
- Vol. 51 (25) , 45542-45554
Characterization of BTO ceramic composite photocurable resin for dielectric applications
- Open Access
- 13 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5455
Classification of Multiple Partial Discharge Sources Using Time-Frequency Analysis and Deep Learning
Partial discharge (PD) analysis is critical for diagnosing insulation degradation in high-voltage equipment. While conventional methods struggle with multi-source PD classification due to signal overlap and noise, this study proposes a hybrid approach combining five time–frequency analysis (TFA) techniques with deep learning (GoogLeNet for simulation, ResNet50 for experiments). PD data are generated through Finite Element Method (FEM) simulations and validated via laboratory experiments. The Scatter Wavelet Transform (SWT) achieves 96.67% accuracy (F1-score: 0.967) in simulation and perfect 100% accuracy (F1-score: 1.000) in experiments, outperforming other TFAs like HHT (70.00% experimental accuracy). The Wigner–Ville Distribution (WVD) also shows strong experimental performance (94.74% accuracy, AUC: 0.947), though its computational complexity limits real-time use. These results demonstrate the SWT’s superiority in handling real-world noise and multi-source PD signals, providing a robust framework for insulation diagnostics in power systems.
- 13 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5455
Open AccessClassification of Multiple Partial Discharge Sources Using Time-Frequency Analysis and Deep Learning
Partial discharge (PD) analysis is critical for diagnosing insulation degradation in high-voltage equipment. While conventional methods struggle with multi-source PD classification due to signal overlap and noise, this study proposes a hybrid approach combining five time–frequency analysis (TFA) techniques with deep learning (GoogLeNet for simulation, ResNet50 for experiments). PD data are generated through Finite Element Method (FEM) simulations and validated via laboratory experiments. The Scatter Wavelet Transform (SWT) achieves 96.67% accuracy (F1-score: 0.967) in simulation and perfect 100% accuracy (F1-score: 1.000) in experiments, outperforming other TFAs like HHT (70.00% experimental accuracy). The Wigner–Ville Distribution (WVD) also shows strong experimental performance (94.74% accuracy, AUC: 0.947), though its computational complexity limits real-time use. These results demonstrate the SWT’s superiority in handling real-world noise and multi-source PD signals, providing a robust framework for insulation diagnostics in power systems.
- 12 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 53-56
Study on Aging Rate of XLPE and its Nanocomposites under Nonstandard Voltage Stresses
Long-term aging tests of XLPE and 1wt%, 3wt%, and 5wt% XLPE-Al 2 O 3 nanocomposites under two different types of electric stresses were carried out. The first stress type represented the ideal sinusoidal waveform, whereas the second one represented a waveform polluted by supraharmonics. The obtained data were treated by Weibull statistics per IEC 62539 / IEEE 930 standard to obtain characteristic lifetimes. Subsequently, the lifetime – electric stress data points were fitted by lifelines using the inverse power law. The results indicated that the 1wt% and 3wt% nano-XLPE samples degraded faster than the unmodified XLPE, especially under the nonstandard supraharmonic stress. Conversely, the 5wt% nano-XLPE seemingly degraded slower. No significant increase in the aging rate of the unmodified XLPE samples was observed at lower stress levels under the supraharmonic electric stress.
- 12 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 53-56
Study on Aging Rate of XLPE and its Nanocomposites under Nonstandard Voltage Stresses
Long-term aging tests of XLPE and 1wt%, 3wt%, and 5wt% XLPE-Al 2 O 3 nanocomposites under two different types of electric stresses were carried out. The first stress type represented the ideal sinusoidal waveform, whereas the second one represented a waveform polluted by supraharmonics. The obtained data were treated by Weibull statistics per IEC 62539 / IEEE 930 standard to obtain characteristic lifetimes. Subsequently, the lifetime – electric stress data points were fitted by lifelines using the inverse power law. The results indicated that the 1wt% and 3wt% nano-XLPE samples degraded faster than the unmodified XLPE, especially under the nonstandard supraharmonic stress. Conversely, the 5wt% nano-XLPE seemingly degraded slower. No significant increase in the aging rate of the unmodified XLPE samples was observed at lower stress levels under the supraharmonic electric stress.
- 17 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (3) , 1882-1891
Impact of High-Frequency Voltage Distortion Emitted by Large Photovoltaic Power Plant on Medium Voltage Cable Systems
Switching processes of voltage source converters can emit significant high-frequency distortions of frequencies between 5 to 20 kHz. Furthermore, the distortions can partly propagate from the place of their origin into a medium voltage system via capacitive coupling of power transformers. The origin, parameters, and propagation process of distortions were clarified by a numerical simulation of a 1-MW photovoltaic power plant connected to the medium voltage distribution grid. The determined results provided input data for the following accelerated aging test setup. The main idea behind the accelerated aging tests was to confirm the effect of the high-frequency distortions on the degradation rate of cable insulation systems. The tests were performed on cable samples, with terminations mounted on each end, which were split into three groups. The first sample group was stressed by increased power frequency voltage and by maximum operating temperature. The second group was stressed similarly, but with superposed high-frequency distortions present. The last group was not stressed to provide reference values for the other groups. Partial discharge, dissipation factor, and breakdown voltage measurements were carried out on both aged groups. The results indicate that cable insulation degradation progresses faster under power frequency voltage with superposed high-frequency distortions.
- 17 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (3) , 1882-1891
Impact of High-Frequency Voltage Distortion Emitted by Large Photovoltaic Power Plant on Medium Voltage Cable Systems
Switching processes of voltage source converters can emit significant high-frequency distortions of frequencies between 5 to 20 kHz. Furthermore, the distortions can partly propagate from the place of their origin into a medium voltage system via capacitive coupling of power transformers. The origin, parameters, and propagation process of distortions were clarified by a numerical simulation of a 1-MW photovoltaic power plant connected to the medium voltage distribution grid. The determined results provided input data for the following accelerated aging test setup. The main idea behind the accelerated aging tests was to confirm the effect of the high-frequency distortions on the degradation rate of cable insulation systems. The tests were performed on cable samples, with terminations mounted on each end, which were split into three groups. The first sample group was stressed by increased power frequency voltage and by maximum operating temperature. The second group was stressed similarly, but with superposed high-frequency distortions present. The last group was not stressed to provide reference values for the other groups. Partial discharge, dissipation factor, and breakdown voltage measurements were carried out on both aged groups. The results indicate that cable insulation degradation progresses faster under power frequency voltage with superposed high-frequency distortions.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Partial Discharge Patterns during Accelerated Aging of Medium Voltage Cable System
Measurement of partial discharges (PDs) and its phase resolved patterns ($\varphi -\mathrm {q}-\mathrm {n}$ characteristics) is one of the most important diagnostic tools for testing of electrical insulation systems. Degradation mechanisms and identification of defects in electrical insulation systems have not been fully cleared yet. Development of knowledge about processes of PDs changes during aging of complex insulation systems is the next desired step. This paper concerns the measurement of the time dependence of phase-resolved PD (PRPD) patterns and PD parameters during combined thermal and electrical accelerated aging of medium voltage cable systems. The ensuing discussion tries to describe PRPD patterns changes. A comparison with PRPD patterns measured by others on insulation samples with internal voids or electrical trees has been carried out as well. PRPD patterns could be classified into four stages in this paper, including “rabbit-like pattern” in the second stage and “turtlelike pattern” in the fourth stage. Changes in PRPD patterns could be linked to initialization and development of electrical treeing. Creation of electrical trees was detected on the XLPE insulation and outer semiconducting layer interface in cable terminations, confirming the weakness part of medium and high voltage cable systems.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Partial Discharge Patterns during Accelerated Aging of Medium Voltage Cable System
Measurement of partial discharges (PDs) and its phase resolved patterns ($\varphi -\mathrm {q}-\mathrm {n}$ characteristics) is one of the most important diagnostic tools for testing of electrical insulation systems. Degradation mechanisms and identification of defects in electrical insulation systems have not been fully cleared yet. Development of knowledge about processes of PDs changes during aging of complex insulation systems is the next desired step. This paper concerns the measurement of the time dependence of phase-resolved PD (PRPD) patterns and PD parameters during combined thermal and electrical accelerated aging of medium voltage cable systems. The ensuing discussion tries to describe PRPD patterns changes. A comparison with PRPD patterns measured by others on insulation samples with internal voids or electrical trees has been carried out as well. PRPD patterns could be classified into four stages in this paper, including “rabbit-like pattern” in the second stage and “turtlelike pattern” in the fourth stage. Changes in PRPD patterns could be linked to initialization and development of electrical treeing. Creation of electrical trees was detected on the XLPE insulation and outer semiconducting layer interface in cable terminations, confirming the weakness part of medium and high voltage cable systems.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Partial Discharges Activity within an Internal Void at AC Voltage Disturbed by High Frequency Components
Frequent use of power electronics in electrical power systems imposes significant impulse and harmonic voltage stresses on various insulation systems. These systems are stressed by very fast and repetitive voltage distortions, which are superimposed on the power frequency voltage. The shape of voltage distortions is usually given by mutual interaction between switching pulses, emitted by power electronics, and passive parameters of power distribution grid. The lifetime of an insulation system is influenced by partial discharge activity that is a consequence of long-term stresses or manufacturing imperfections. It has been proven that the intensity of partial discharges significantly depends on the operating voltage waveform. The paper deals with the experimental measurement of partial discharges on the physical model of an internal void in a solid dielectric under above mentioned voltage stress conditions. The designed and realized high voltage test circuit consists of a high voltage test transformer and a high-frequency high voltage transformer, to generate the superposition of power frequency high voltage and harmonics up to 15 kV or impulses with various repetition and oscillation frequencies. Gathered patterns and parameters of partial discharges were analyzed and evaluated to determine whether there exists any influence of higher harmonics content on the lifetime of the insulation system. The presented results show that the presence of high frequency oscillations on power frequency voltage have the direct impact on the partial discharge activity. These findings can be significant for the insulation design and insulation lifetime assessment in the power systems containing power electronic switching devices.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Partial Discharges Activity within an Internal Void at AC Voltage Disturbed by High Frequency Components
Frequent use of power electronics in electrical power systems imposes significant impulse and harmonic voltage stresses on various insulation systems. These systems are stressed by very fast and repetitive voltage distortions, which are superimposed on the power frequency voltage. The shape of voltage distortions is usually given by mutual interaction between switching pulses, emitted by power electronics, and passive parameters of power distribution grid. The lifetime of an insulation system is influenced by partial discharge activity that is a consequence of long-term stresses or manufacturing imperfections. It has been proven that the intensity of partial discharges significantly depends on the operating voltage waveform. The paper deals with the experimental measurement of partial discharges on the physical model of an internal void in a solid dielectric under above mentioned voltage stress conditions. The designed and realized high voltage test circuit consists of a high voltage test transformer and a high-frequency high voltage transformer, to generate the superposition of power frequency high voltage and harmonics up to 15 kV or impulses with various repetition and oscillation frequencies. Gathered patterns and parameters of partial discharges were analyzed and evaluated to determine whether there exists any influence of higher harmonics content on the lifetime of the insulation system. The presented results show that the presence of high frequency oscillations on power frequency voltage have the direct impact on the partial discharge activity. These findings can be significant for the insulation design and insulation lifetime assessment in the power systems containing power electronic switching devices.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Life-Time of Oil Filled Insulation Paper under Nonstandard Voltage Stresses
In the recent years, technological development gave rise to numerous systems that utilize power semiconductor devices. As much as these devices improve the performance of electrical systems, they also pollute the network with voltage distortions. A mutual interaction between switching pulses, emitted by power electronics, and passive parameters of power system produce high-frequency harmonics and oscillating impulses. Although there are quite strict rules that define the maximum levels of such distortions, they are still theoretically able to increase the electrical stress of some parts of the power network. The distortions could, therefore, accelerate the aging process of insulation systems, which would, among others, pose a threat to the stability of electrical networks. Recently, a new aging model that respects nonsinusoidal voltage stresses has been developed. The model introduces a trio of specific parameters to describe the shape of applied voltage stress. This model has been applied to polymeric insulation, but the validity of this model for other insulation materials has not been verified yet. For this purpose, laboratory measurements with oil filled transformer paper insulation samples were carried out in our research. Voltage-time characteristics of transformer insulation paper were measured and evaluated by Weibull distribution. Parameters of Weibull distribution were determined and discussed. The increased effect of nonstandard voltage stress on a life-time of paper insulation was detected. The experimental results were discussed with the calculated results of the theoretical aging model. Specific parameters of the mentioned model were also calculated and compared with other available research publications.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Life-Time of Oil Filled Insulation Paper under Nonstandard Voltage Stresses
In the recent years, technological development gave rise to numerous systems that utilize power semiconductor devices. As much as these devices improve the performance of electrical systems, they also pollute the network with voltage distortions. A mutual interaction between switching pulses, emitted by power electronics, and passive parameters of power system produce high-frequency harmonics and oscillating impulses. Although there are quite strict rules that define the maximum levels of such distortions, they are still theoretically able to increase the electrical stress of some parts of the power network. The distortions could, therefore, accelerate the aging process of insulation systems, which would, among others, pose a threat to the stability of electrical networks. Recently, a new aging model that respects nonsinusoidal voltage stresses has been developed. The model introduces a trio of specific parameters to describe the shape of applied voltage stress. This model has been applied to polymeric insulation, but the validity of this model for other insulation materials has not been verified yet. For this purpose, laboratory measurements with oil filled transformer paper insulation samples were carried out in our research. Voltage-time characteristics of transformer insulation paper were measured and evaluated by Weibull distribution. Parameters of Weibull distribution were determined and discussed. The increased effect of nonstandard voltage stress on a life-time of paper insulation was detected. The experimental results were discussed with the calculated results of the theoretical aging model. Specific parameters of the mentioned model were also calculated and compared with other available research publications.