Sanjay M. Mallya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sanjay M. Mallya has a total of 150 co-authors. Here are the top co-authors by number of shared publications:
- Andrew Arnold
University of Connecticut School of Medicine
4 shared publications Aruna Ramesh
Professor, Division of Oral and Maxillofacial Radiology, Tufts University School of Dental Medicine, Boston, MA
4 shared publicationsSotirios Tetradis
Section of Oral and Maxillofacial Radiology, School of Dentistry, University of California Los Angeles, 10833 Le Conte Avenue, Los Angeles, CA 90095-1668, USA
4 shared publications- Sven Kreiborg
University of Copenhagen
4 shared publications - Hiroaki Shimamoto
Department of Oral and Maxillofacial Radiology, Graduate School of Dentistry, The University of Osaka, Suita, Japan
3 shared publications Kirsten Saucier
B Center for Molecular Medicine , University of Connecticut School of Medicine , Farmington , CT , USA
3 shared publications
Latest Publications
- Open Access
- 4 May 2026
- Published byĀ Springer NatureĀ inĀ Oral Radiology
- Vol.Ā 42 Ā (4) , 935-942
A novel dual-energy cone beam computed tomography device for assessment of jaw bone density
Objectives: Cone beam computed tomography (CBCT) provides morphological details of the dental hard tissues and bone. However, the relationship between object density and CBCT grey values is unreliable and limits application of CBCT for quantitative evaluation of bone density. This single center, open-label clinical trial investigated the validity of novel dual-energy CBCT device (DE-CBCT) to assess jaw bone density. Methods: The study analyses comprised 24 subjects who were examined with DE-CBCT and multidetector CT (MDCT)āan established standard for bone density assessment. MDCT and DE-CBCT scans of each subject were analyzed in the vendorās software application for assessment of bone density at 10 discrete sites in the jaws. Two independent assessments were made. Results: The mean bone density assessed by DE-CBCT and MDCT were not significantly different (0.46 ± 0.36 g/cc versus 0.48 ± 0.31 g/cc, respectively). Bone density assessments from DE-CBCT correlated well with MDCT assessments (Pearsonās correlation r = 0.92, p < 0.0001). Bland-Altman analyses demonstrated higher agreement between the two techniques at densities great than 0.6 g/cm 3 . However, at lower densities the limits of agreement were broad. Conclusions: DE-CBCT is a promising approach to assess bone density in the jaw bones. The investigational device performs best in well-trabeculated and cortical bone, with reduced reliability in sparsely trabeculated regions. Future refinements in this technology will be needed to expand the range of reliability for reliable assessment of bone density. Clinical trials registration: The study is registered in clinical trials.gov, NCT04686084.
- 4 May 2026
- Published byĀ Springer NatureĀ inĀ Oral Radiology
- Vol.Ā 42 Ā (4) , 935-942
Open AccessA novel dual-energy cone beam computed tomography device for assessment of jaw bone density
Objectives: Cone beam computed tomography (CBCT) provides morphological details of the dental hard tissues and bone. However, the relationship between object density and CBCT grey values is unreliable and limits application of CBCT for quantitative evaluation of bone density. This single center, open-label clinical trial investigated the validity of novel dual-energy CBCT device (DE-CBCT) to assess jaw bone density. Methods: The study analyses comprised 24 subjects who were examined with DE-CBCT and multidetector CT (MDCT)āan established standard for bone density assessment. MDCT and DE-CBCT scans of each subject were analyzed in the vendorās software application for assessment of bone density at 10 discrete sites in the jaws. Two independent assessments were made. Results: The mean bone density assessed by DE-CBCT and MDCT were not significantly different (0.46 ± 0.36 g/cc versus 0.48 ± 0.31 g/cc, respectively). Bone density assessments from DE-CBCT correlated well with MDCT assessments (Pearsonās correlation r = 0.92, p < 0.0001). Bland-Altman analyses demonstrated higher agreement between the two techniques at densities great than 0.6 g/cm 3 . However, at lower densities the limits of agreement were broad. Conclusions: DE-CBCT is a promising approach to assess bone density in the jaw bones. The investigational device performs best in well-trabeculated and cortical bone, with reduced reliability in sparsely trabeculated regions. Future refinements in this technology will be needed to expand the range of reliability for reliable assessment of bone density. Clinical trials registration: The study is registered in clinical trials.gov, NCT04686084.
- 21 January 2026
- Published byĀ Oxford University Press (OUP)Ā inĀ Dentomaxillofacial Radiology
Craniofacial measurements using zero echo time magnetic resonance imaging
Objectives: Radiation exposure remains a major concern in dentomaxillofacial imaging, especially for children and young adults who require repeated examinations. A precise, non-ionizing alternative for craniofacial measurement would have significant implications for clinical practice. Computed tomography (CT) and cephalometry are widely used but expose patients to ionizing radiation. Zero Echo Time Magnetic Resonance Imaging (ZTE-MRI) enables visualization of short-T2 tissues, including cortical bone, without radiation by minimizing TE towards zero; however, clinical head-and-neck use has been limited. The goal of the present study was to investigate the possibility of performing precise 3D measurements of the craniofacial regions using ZTE-MRI. Methods: Twenty-nine participants (mean age 32.14 ± 17.09 years; 23 female, 6 male) underwent MDCT and ZTE-MRI. Standard cephalometric landmarks were identified, yielding 27 linear and 21 angular variables. For each variable, linear regression analysis was performed for the results on MDCT (Multi-Detector CT) images and ZTE-MRI. Results: Nineteen linear and eight angular variables had regression coefficients between 0.9 and 1.1, and 28 of the linear and 16 of the angular variables had R2 values of 0.81 or higher. Twenty-five linear and 16 angular variables showed Cohenās effect sizes within the ±0.8 range. Conclusions: Variables derived from skeletal reference points showed clinically acceptable results, indicating that ZTE-MRI is useful for these measurements. In contrast, variables involving dental reference points demonstrated lower agreement, making accurate measurement in these regions difficult. Advances in knowledge: To our knowledge, this study is the first to show that ZTE-MRI allows feasible linear and angular craniofacial measurements used in dental practice and demonstrates good agreement with MDCT for major skeletal landmarks. These findings support its potential future clinical applicability for radiation-free bone assessment; however, further research is warranted to establish its performance across all measurements.
- 21 January 2026
- Published byĀ Oxford University Press (OUP)Ā inĀ Dentomaxillofacial Radiology
Craniofacial measurements using zero echo time magnetic resonance imaging
Objectives: Radiation exposure remains a major concern in dentomaxillofacial imaging, especially for children and young adults who require repeated examinations. A precise, non-ionizing alternative for craniofacial measurement would have significant implications for clinical practice. Computed tomography (CT) and cephalometry are widely used but expose patients to ionizing radiation. Zero Echo Time Magnetic Resonance Imaging (ZTE-MRI) enables visualization of short-T2 tissues, including cortical bone, without radiation by minimizing TE towards zero; however, clinical head-and-neck use has been limited. The goal of the present study was to investigate the possibility of performing precise 3D measurements of the craniofacial regions using ZTE-MRI. Methods: Twenty-nine participants (mean age 32.14 ± 17.09 years; 23 female, 6 male) underwent MDCT and ZTE-MRI. Standard cephalometric landmarks were identified, yielding 27 linear and 21 angular variables. For each variable, linear regression analysis was performed for the results on MDCT (Multi-Detector CT) images and ZTE-MRI. Results: Nineteen linear and eight angular variables had regression coefficients between 0.9 and 1.1, and 28 of the linear and 16 of the angular variables had R2 values of 0.81 or higher. Twenty-five linear and 16 angular variables showed Cohenās effect sizes within the ±0.8 range. Conclusions: Variables derived from skeletal reference points showed clinically acceptable results, indicating that ZTE-MRI is useful for these measurements. In contrast, variables involving dental reference points demonstrated lower agreement, making accurate measurement in these regions difficult. Advances in knowledge: To our knowledge, this study is the first to show that ZTE-MRI allows feasible linear and angular craniofacial measurements used in dental practice and demonstrates good agreement with MDCT for major skeletal landmarks. These findings support its potential future clinical applicability for radiation-free bone assessment; however, further research is warranted to establish its performance across all measurements.
- 15 December 2025
- Published byĀ WileyĀ inĀ Journal of Dental Education
- Vol.Ā 90 Ā (9) , 1342-1349
Artificial Intelligence in Dental Education: A Pilot Study of Caries Detection Accuracy and Instructor Agreement
Purpose: This pilot study evaluated the use of Second Opinion , an artificial intelligence (AI)ābased radiographic evaluation tool, to support instruction in radiographic caries detection by examining its impact on instructor diagnostic performance and interāinstructor agreement, as well as its potential to improve instructional consistency. Methods: This study used data from faculty calibration and examination development for a secondāyear predoctoral dental student instructional module on radiographic caries detection. Instructor diagnostic performanceāincluding sensitivity, specificity, accuracy, precision, and F1 scoreāwas evaluated with and without AIāassisted interpretation across varying carious lesion depths. Results: Instructors demonstrated high baseline diagnostic performance, with group average metrics exceeding 91% across all parameters. There was strong agreement between Second Opinion and instructor assessments, and AIāassisted interpretation led to modest, nonāsignificant improvements in diagnostic performance. Notably, AI use increased the rate of unanimous agreement, particularly for sound surfaces (E0) and earlyātoāmoderate dentinal caries (D1/D2). Conclusions: Second Opinion demonstrated diagnostic performance comparable to that of the instructor group in radiographic caries detection and contributed to improved interāinstructor agreement. These findings support its use in instructor calibration and case selection, highlighting the potential of AIāassisted interpretation to enhance instructional consistency and strengthen assessment reliability in dental radiographic education.
- 15 December 2025
- Published byĀ WileyĀ inĀ Journal of Dental Education
- Vol.Ā 90 Ā (9) , 1342-1349
Artificial Intelligence in Dental Education: A Pilot Study of Caries Detection Accuracy and Instructor Agreement
Purpose: This pilot study evaluated the use of Second Opinion , an artificial intelligence (AI)ābased radiographic evaluation tool, to support instruction in radiographic caries detection by examining its impact on instructor diagnostic performance and interāinstructor agreement, as well as its potential to improve instructional consistency. Methods: This study used data from faculty calibration and examination development for a secondāyear predoctoral dental student instructional module on radiographic caries detection. Instructor diagnostic performanceāincluding sensitivity, specificity, accuracy, precision, and F1 scoreāwas evaluated with and without AIāassisted interpretation across varying carious lesion depths. Results: Instructors demonstrated high baseline diagnostic performance, with group average metrics exceeding 91% across all parameters. There was strong agreement between Second Opinion and instructor assessments, and AIāassisted interpretation led to modest, nonāsignificant improvements in diagnostic performance. Notably, AI use increased the rate of unanimous agreement, particularly for sound surfaces (E0) and earlyātoāmoderate dentinal caries (D1/D2). Conclusions: Second Opinion demonstrated diagnostic performance comparable to that of the instructor group in radiographic caries detection and contributed to improved interāinstructor agreement. These findings support its use in instructor calibration and case selection, highlighting the potential of AIāassisted interpretation to enhance instructional consistency and strengthen assessment reliability in dental radiographic education.
- Open Access
- 1 January 2025
- Published byĀ Wolters Kluwer HealthĀ inĀ Journal of Indian Academy of Oral Medicine and Radiology
- Vol.Ā 37 Ā (1) , 3-4
Beyond the Image: Adding Value to the Radiology Report with Actionable Insights
- 1 January 2025
- Published byĀ Wolters Kluwer HealthĀ inĀ Journal of Indian Academy of Oral Medicine and Radiology
- Vol.Ā 37 Ā (1) , 3-4
Open AccessBeyond the Image: Adding Value to the Radiology Report with Actionable Insights
- Open Access
- 31 October 2023
- Published byĀ ElsevierĀ inĀ The Journal of the American Dental Association
- Vol.Ā 155 Ā (1) , 48-58
Applying the American Association of Endodontists and American Academy of Oral and Maxillofacial Radiology guidelines for cone-beam computed tomography prescription
- 31 October 2023
- Published byĀ ElsevierĀ inĀ The Journal of the American Dental Association
- Vol.Ā 155 Ā (1) , 48-58
Open AccessApplying the American Association of Endodontists and American Academy of Oral and Maxillofacial Radiology guidelines for cone-beam computed tomography prescription
- 27 October 2023
- Published byĀ ElsevierĀ inĀ The Journal of the American Dental Association
- Vol.Ā 154 Ā (12) , 1046-1047
Authorsā Response
- 27 October 2023
- Published byĀ ElsevierĀ inĀ The Journal of the American Dental Association
- Vol.Ā 154 Ā (12) , 1046-1047
Authorsā Response
- Open Access
- 1 August 2023
- Published byĀ ElsevierĀ inĀ The Journal of the American Dental Association
- Vol.Ā 154 Ā (9) , 826-835.e2
Patient shielding during dentomaxillofacial radiography
- 1 August 2023
- Published byĀ ElsevierĀ inĀ The Journal of the American Dental Association
- Vol.Ā 154 Ā (9) , 826-835.e2
Open AccessPatient shielding during dentomaxillofacial radiography
- Open Access
- 1 January 2023
- Published byĀ MRE PressĀ inĀ Journal of Oral & Facial Pain and Headache
- Vol.Ā 37 Ā (1) , 7-15
Recommendations for Imaging of the Temporomandibular Joint. Position Statement from the American Academy of Oral and Maxillofacial Radiology and the American Academy of Orofacial Pain
Sanjay M. Mallya, BDS, MDS, PhD/Mansur Ahmad, BDS, PhD/Joseph R. Cohen, DDS/Ghabi Kaspo, DDS/Aruna Ramesh, BDS, DMD, MS: This position statement was developed by an ad hoc committee of the American Academy of Oral and Maxillofacial Radiology and the American Academy of Orofacial Pain. The committee reviewed the pertinent literature and drafted recommendations for imaging. This joint statement provides evidence-based recommendations and clinical guidance for applying appropriate diagnostic imaging to evaluate the temporomandibular joint (TMJ). This manuscript guides the design of TMJ imaging examinations, addresses in-office CBCT imaging, and provides timely evidence-based recommendations to evaluate the TMJ bony components, also addressing the use of MRI and other modalities to evaluate TMJ involvement in different pathologic conditions.
- 1 January 2023
- Published byĀ MRE PressĀ inĀ Journal of Oral & Facial Pain and Headache
- Vol.Ā 37 Ā (1) , 7-15
Open AccessRecommendations for Imaging of the Temporomandibular Joint. Position Statement from the American Academy of Oral and Maxillofacial Radiology and the American Academy of Orofacial Pain
Sanjay M. Mallya, BDS, MDS, PhD/Mansur Ahmad, BDS, PhD/Joseph R. Cohen, DDS/Ghabi Kaspo, DDS/Aruna Ramesh, BDS, DMD, MS: This position statement was developed by an ad hoc committee of the American Academy of Oral and Maxillofacial Radiology and the American Academy of Orofacial Pain. The committee reviewed the pertinent literature and drafted recommendations for imaging. This joint statement provides evidence-based recommendations and clinical guidance for applying appropriate diagnostic imaging to evaluate the temporomandibular joint (TMJ). This manuscript guides the design of TMJ imaging examinations, addresses in-office CBCT imaging, and provides timely evidence-based recommendations to evaluate the TMJ bony components, also addressing the use of MRI and other modalities to evaluate TMJ involvement in different pathologic conditions.
- 16 August 2022
- Published byĀ ElsevierĀ inĀ Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol.Ā 134 Ā (3) , e82-e83
Applying ADA/ANSI Standard 1094: Impact of image adjustments and display device on subjective assessments
- 16 August 2022
- Published byĀ ElsevierĀ inĀ Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol.Ā 134 Ā (3) , e82-e83
Applying ADA/ANSI Standard 1094: Impact of image adjustments and display device on subjective assessments
- 16 August 2022
- Published byĀ ElsevierĀ inĀ Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol.Ā 134 Ā (3) , e75
Effectiveness of image optimization in digital intraoral radiographic systems
- 16 August 2022
- Published byĀ ElsevierĀ inĀ Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol.Ā 134 Ā (3) , e75
Effectiveness of image optimization in digital intraoral radiographic systems