KHKevin Cecil Hewitt

Kevin Cecil Hewitt

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kevin Cecil Hewitt has a total of 149 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Liver Discard Rate Attributable to Conservative Estimations of Steatosis: An Inference-based Approach

    by Hao Guo, Boris L. Gala-Lopez, Ian P.J. Alwayn, Kevin C. Hewitt

    Background. On-site conservative estimations of steatosis could result in the unnecessary discard of donor livers. This study applied the body mass index as an independent statistical indicator to determine the extent of this problem. We aimed to quantitatively evaluate if decisions based nonbiopsy donor liver assessments are more conservative (inclined to reject marginal fatty livers) than biopsy-based evaluations. Methods. The study processed intradatabase comparisons using 177 081 datasets from Organ Procurement and Transplantation Network spanning 2004 to 2022 September in the United States. Postmatching body mass index was applied as an independent indicator of statistical risk of hepatic steatosis (HS). Results. A total of 7420, 4990, 5994, and 7523 pair of donors with/without biopsy records were matched in 2004–2010, 2011–2014, 2015–2018, and 2019–2022 September, respectively. Consistent with our hypothesis, absent biopsies and evaluations before and during organ procurement were observed to be more conservative, leading to the discard of 16.4% (2004–2010), 16.9% (2011–2014), 10.6% (2015–2018), and 10.3% (2019–2022 September) of potential donor livers. Conclusions. The study concludes that there was a significant (10.3%–16.9%) disparity caused by on-site nonbiopsy assessments of HS, leading to the unnecessary discard of potential donor livers. The findings emphasize the need to develop more accurate intraoperative techniques for assessing HS to optimize donor liver procurement. Export


  • Open Access

    Canadian physics counts: an exploration of the diverse identities of physics students and professionals in Canada

    by Eden J. Hennessey, Anastasia Smolina, Skye Hennessey, Adrianna Tassone, Alex Jay, Shohini Ghose, Kevin Hewitt

    The lack of diversity in physics remains a worldwide problem. Despite being a quantitative discipline relying on measurements, there is a paucity of data on the demographic characteristics of underrepresented groups. We present findings from Canadian Physics Counts: the first national survey of equity, diversity, and inclusion in the Canadian physics community. Our intersectional approach provides a wealth of information on gender identity, sexual orientation, race, disability, and more. Analyses revealed key findings, including the first comprehensive Canadian data on nonbinary or gender diverse physicists, and the first data on Black (1.2%) and Indigenous (0.3%) physicists, who were least represented. Assessing representation across roles and career stages, BIPOC (Black, Indigenous, and People of Colour), representation fell precipitously (by one-half) between under/graduate to professional roles, while White women’s representation remained relatively stable, and White men’s representation steadily increased. One in four BIPOC respondents from gender diverse backgrounds identified as disabled, and the proportion of sexually diverse students with disabilities was more than three times higher than the proportion of heterosexual students with disabilities, underscoring the necessity of intersectional analyses. Students were more demographically diverse than professionals, highlighting the importance of acting today to retain the diverse physicists of tomorrow


  • Open Access

    Evaluation of Minimum‐to‐Severe Global and Macrovesicular Steatosis in Human Liver Specimens: A Portable Ambient Light‐Compatible Spectroscopic Probe

    by Hao Guo, Ashley E. Stueck, Jason B. Doppenberg, Yun Suk Chae, Alexey B. Tikhomirov, Haishan Zeng, Marten A. Engelse, Boris L. Gala‐Lopez, Anita Mahadevan‐Jansen, Ian P. J. Alwayn, et al.

    Background and Aims: Hepatic steatosis (HS), particularly macrovesicular steatosis (MaS), influences transplant outcomes. Accurate assessment of MaS is crucial for graft selection. While traditional assessment methods have limitations, non‐invasive spectroscopic techniques like Raman and reflectance spectroscopy offer promise. This study aimed to evaluate the efficacy of a portable ambient light‐compatible spectroscopic system in assessing global HS and MaS in human liver specimens.Methods: A two‐stage approach was employed on thawed snap‐frozen human liver specimens under ambient room light: biochemical validation involving a comparison of fat content from Raman and reflectance intensities with triglyceride (TG) quantifications and histopathological validation, contrasting Raman‐derived fat content with evaluations by an expert pathologist and a “Positive Pixel Count” algorithm. Raman and reflectance intensities were combined to discern significant (≥ 10%) discrepancies in global HS and MaS.Results: The initial set of 16 specimens showed a positive correlation between Raman and reflectance‐derived fat content and TG quantifications. The Raman system effectively differentiated minimum‐to‐severe global and macrovesicular steatosis in the subsequent 66 specimens. A dual‐variable prediction algorithm was developed, effectively classifying significant discrepancies (> 10%) between algorithm‐estimated global HS and pathologist‐estimated MaS.Conclusion: Our study established the viability and reliability of a portable spectroscopic system for non‐invasive HS and MaS assessment in human liver specimens. The compatibility with ambient light conditions and the ability to address limitations of previous methods marks a significant advancement in this field. By offering promising differentiation between global HS and MaS, our system introduces an innovative approach to real‐time and quantitative donor HS assessments. The proposed method holds the promise of refining donor liver assessment during liver recovery and ultimately enhancing transplantation outcomes.


  • Open Access

    Potential of Raman‐Reflectance Combination in Quantifying Liver Steatosis and Fat Droplet Size: Evidence From Monte Carlo Simulations and Phantom Studies

    by Hao Guo, Vanessa S. Zions, Brent A. Law, Kevin C. Hewitt

    This study explores a combined strategy of Raman and reflectance spectroscopy for quantifying liver fat content and fat droplet size, crucial in assessing donor livers. By using Monte Carlo simulations and experimental setups with oil‐in‐water phantoms, our findings indicate that Raman scattering can solely differentiate between varying fat contents. At the same time, reflectance intensity is influenced by both fat content and oil droplet size, with a more pronounced sensitivity to fat droplet size. This study demonstrates the efficacy of combined Raman and reflectance spectroscopy in assessing liver steatosis and fat droplet size, potentially aiding in assessing donor livers for transplantation.


  • Open Access

    Evaluation of minimum-to-severe global and macrovesicular steatosis in human liver specimens: a portable ambient light-compatible spectroscopic probe

    by Hao Guo, Ashley E. Stueck, Jason B. Doppenberg, Yun Suk Chae, Alexey B. Tikhomirov, Haishan Zeng, Marten A. Engelse, Boris L. Gala-Lopez, Anita Mahadevan-Jansen, Ian P.J. Alwayn, et al.

    This study presents a portable spectroscopic system compatible with ambient light to assess hepatic steatosis (HS) and macrovesicular steatosis (MaS) in human liver specimens. Traditional assessment methods for MaS are limited, prompting the need for non-invasive alternatives. The study utilized a two-stage approach on thawed snap-frozen liver specimens. Biochemical validation compared fat content from Raman and reflectance intensities with triglyceride (TG) quantifications, while histopathological validation contrasted Raman-derived fat content with pathologist evaluations and an algorithm. Analysis of 16 specimens showed a positive correlation between spectroscopic data and TG quantifications. The Raman system differentiated various degrees of global HS and MaS in an additional 66 specimens. A dual-variable prediction algorithm classified significant discrepancies (≥10%) between algorithm-estimated global HS and pathologist-estimated MaS. This study demonstrates the viability of a portable spectroscopic system for non-invasive HS and MaS assessment to enhance real-time donor liver assessments during recovery to improve transplantation outcomes.

  • Open Access

    Potential of Raman-reflectance combination to quantify liver steatosis and fat droplet size: evidence from Monte Carlo simulations and phantom studies

    by Hao Guo, Vanessa S. Zions, Brent A. Law, Kevin Hewitt

    This study explores a combined strategy of Raman and reflectance spectroscopy for quantifying liver fat content and fat droplet size, crucial in assessing donor livers. By using Monte Carlo simulations and experimental setups with oil-in-water phantoms, our findings indicate that Raman scattering can solely differentiate between varying fat contents, while reflectance intensity is influenced by both fat content and oil droplet size, with a more pronounced sensitivity to fat droplet size. This study demonstrates the efficacy of combined Raman and reflectance spectroscopy in assessing liver steatosis and fat droplet size, potentially aiding in assessing donor livers for transplantation.


  • Open Access

    Liver discard rate due to conservative estimations of steatosis: an inference-based approach

    by Hao Guo, Boris L. Gala-Lopez, Ian P.J. Alwayn, Kevin C. Hewitt

    Background: On-site conservative estimations of steatosis could result in the unnecessary discard of donor livers. This study applied the body mass index (BMI) as an independent statistical indicator to determine the extent of this problem. We explored two hypotheses: (I) that because of varying levels of expertise and protocols (reputational risk for pathologists), biopsies at transplant centers overestimate hepatic steatosis (HS), and (ii) that non-biopsy donor liver assessments are more conservative than biopsy-based evaluations. Methods: The study processed cross-database and intra-database comparisons using data from the National Health and Nutrition Examination Survey (NHANES) and Organ Procurement and Transplantation Network (OPTN) spanning January 2017 to March 2020 in the United States. Post-matching BMI was applied as an independent indicator of statistical risk of HS. Results: Contrary to our first hypothesis , biopsies at transplant centers did not overestimate HS - biopsy-classified donor livers were found in similar or lower risk categories. Consistent with our second hypothesis , absent biopsies, evaluations before and during organ procurement were observed to be more conservative, leading to the discard of 11.9% (373) of potential donor livers. Conclusions: The study concludes that there was a significant (11.9%) disparity caused by on-site non-biopsy assessments of HS, leading to the unnecessary discard of potential donor livers. The findings emphasize the need to develop more accurate intraoperative techniques for assessing HS to optimize donor liver procurement.


  • Open Access

    Evaluation of minimum-to-severe global and macrovesicular steatosis in human liver specimens: a portable ambient light-compatible spectroscopic probe

    by Hao Guo, Ashley E. Stueck, Jason B. Doppenberg, Yun Suk Chae, Alexey B. Tikhomirov, Haishan Zeng, Marten A. Engelse, Boris L. Gala-Lopez, Anita Mahadevan-Jansen, Ian P.J. Alwayn, et al.

    Background & Aims Hepatic steatosis (HS), particularly macrovesicular steatosis (MaS), influences transplant outcomes. Accurate assessment of MaS is crucial for graft selection. While traditional assessment methods have limitations, non-invasive spectroscopic techniques like Raman and reflectance spectroscopy offer promise. This study aimed to evaluate the efficacy of a portable ambient light-compatible spectroscopic system in assessing global HS and MaS in human liver specimens. Methods A two-stage approach was employed on thawed snap-frozen human liver specimens under ambient room light: biochemical validation involving a comparison of fat content from Raman and reflectance intensities with triglyceride (TG) quantifications and histopathological validation, contrasting Raman-derived fat content with evaluations by an expert pathologist and an artificial intelligence (AI) algorithm. Raman and reflectance intensities were combined to discern significant (≥10%) discrepancies in global HS and MaS. Results The initial set of 16 specimens showed a positive correlation between Raman and reflectance-derived fat content and TG quantifications. The Raman system effectively differentiated minimum-to-severe global and macrovesicular steatosis in the subsequent 66 specimens. A dual-variable prediction algorithm, was developed, effectively classifying significant discrepancies (>10%) between AI-estimated global HS and pathologist-estimated MaS. Conclusion Our study established the viability and reliability of a portable spectroscopic system for non-invasive HS and MaS assessment in human liver specimens. The compatibility with ambient light conditions and the ability to address limitations of previous methods marks a significant advancement in this field. By offering promising differentiation between global HS and MaS, our system introduces an innovative approach to real-time and quantitative donor HS assessments. The proposed method holds promise of refining donor liver assessment during liver recovery and ultimately elevating transplantation outcomes. Lay Summary This research explored a portable ambient light-compatible spectroscopic probe to non-invasively assess global and macrovesicular steatosis in human liver specimens. Our findings suggest that this method can be a reliable tool to aid surgeons’ decision-making on a liver’s suitability for transplantation. Highlights We introduced a portable ambient light-compatible spectroscopic probe which could non-invasively analyze Raman scattering and reflectance of human liver specimens. Both biochemical and histopathological approaches were applied to validate the spectroscopic probe. Histopathological evaluation covered minimum-to-severe global and macrovesicular steatosis, surpassing previous spectroscopic studies. A dual-variable prediction for precise differentiation between global and macrovesicular steatosis offers the potential for enhanced, real-time, and quantitative liver assessments in clinical settings.


  • Evaluation of Steatosis in Human Liver Specimens Using an Ambient Light-compatible Raman Spectroscopy Approach

    by Hao Guo, Ashley E. Stueck, Alexey B. Tikhomirov, Haishan Zeng, Ian P.J. Alwayn, Boris L. Gala-Lopez, Anita Mahadevan-Jansen, Andrea K. Locke, Kevin C. Hewitt

    We analyzed 70 human liver tissue samples using a filter-based 1064-nm Raman system and Oil Red O staining. The system effectively differentiated low/high-risk liver macrosteatosis, with an area under the operating characteristic curve of 0.92.


  • Real-time assessment of liver fat content using a filter-based Raman system operating under ambient light through lock-in amplification

    by Hao Guo, Alexey B. Tikhomirov, Alexandria Mitchell, Ian Patrick Joseph Alwayn, Haishan Zeng, Kevin C. Hewitt

    During liver procurement, surgeons mostly rely on their subjective visual inspection of the liver to assess the degree of fatty infiltration, for which misclassification is common. We developed a Raman system, which consists of a 1064 nm laser, a handheld probe, optical filters, photodiodes, and a lock-in amplifier for real-time assessment of liver fat contents. The system performs consistently in normal and strong ambient light, and the excitation incident light penetrates at least 1 mm into duck fat phantoms and duck liver samples. The signal intensity is linearly correlated with MRI-calibrated fat contents of the phantoms and the liver samples.