Muhammad Nasir Ibrahim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Muhammad Nasir Ibrahim has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Mariani Idroas
Faculty of Chemical and Energy Engineering, University Teknologi Malaysia, 81310 Johor Bahru, Johor
7 shared publicationsM. Idroas
5 shared publications- Mariani Idroas
Faculty of Chemical & Natural Resources Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor, Malaysia
5 shared publications - Mohd Hafiz Fazalul Rahiman
Faculty of Electrical Engineering & Technology Universiti Malaysia Perlis, Pauh Putra Campus 02600 Arau, Perlis, Malaysia
4 shared publications - Norhafizah Ramli
Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
3 shared publications - Ruzairi Abdul Rahim
Universiti Teknologi Malaysia
3 shared publications
Latest Publications
- Open Access
- 20 January 2017
- Published by ZIbeline International Publishing in Earth Science Malaysia
- Vol. 1 (1) , 32-35
X-Ray Differaction Analysis For The Interpretation of Clay Minerals Paragenesis in The Neogene Sediments of Mang and Vicinity, Sub-Himalayas, Pakistan
- 20 January 2017
- Published by ZIbeline International Publishing in Earth Science Malaysia
- Vol. 1 (1) , 32-35
Open AccessX-Ray Differaction Analysis For The Interpretation of Clay Minerals Paragenesis in The Neogene Sediments of Mang and Vicinity, Sub-Himalayas, Pakistan
- Open Access
- 27 July 2016
- Published by Indian Society for Education and Environment in Indian Journal of Science and Technology
- Vol. 9 (28)
Hardware Development for Optical Tomography System based on Complementary Metal Oxide Semiconductor Linear Image Sensor
Nowadays, particle characterization such as size, count and shape, has been widely used in industrial processes to provide better understanding on their products. An optical tomography system has proven to be a useful approach in characterizing particles due to its ability to determine the content of a closed system without any physical contact. Thus, this paper presents the use of Complementary Metal Oxide Semiconductor linear image sensor in the development of optical tomography system, where the system is used for solid particle characterization. The developed system used the CMOS S10077 Linear Image Sensor as the optical detector, and Arduino Nano microcontroller to control the sensor’s operation and to provide a data acquisition system for the CMOS S10077. The Data Display Serial Port application is used to display data from the sensor in a numeric array to allow pattern plotting of its result. Particle characterization experiments based on count is conducted after the completion of the hardware and software setup. The experimental results are collected and analyzed. The verification of the experimental and actual results is determined based on the analysis of the particle counts.
- 27 July 2016
- Published by Indian Society for Education and Environment in Indian Journal of Science and Technology
- Vol. 9 (28)
Open AccessHardware Development for Optical Tomography System based on Complementary Metal Oxide Semiconductor Linear Image Sensor
Nowadays, particle characterization such as size, count and shape, has been widely used in industrial processes to provide better understanding on their products. An optical tomography system has proven to be a useful approach in characterizing particles due to its ability to determine the content of a closed system without any physical contact. Thus, this paper presents the use of Complementary Metal Oxide Semiconductor linear image sensor in the development of optical tomography system, where the system is used for solid particle characterization. The developed system used the CMOS S10077 Linear Image Sensor as the optical detector, and Arduino Nano microcontroller to control the sensor’s operation and to provide a data acquisition system for the CMOS S10077. The Data Display Serial Port application is used to display data from the sensor in a numeric array to allow pattern plotting of its result. Particle characterization experiments based on count is conducted after the completion of the hardware and software setup. The experimental results are collected and analyzed. The verification of the experimental and actual results is determined based on the analysis of the particle counts.
- 1 December 2015
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 220, 75-80
Imaging particles in solid/air flows using an optical tomography system based on complementary metal oxide semiconductor area image sensors
- 1 December 2015
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 220, 75-80
Imaging particles in solid/air flows using an optical tomography system based on complementary metal oxide semiconductor area image sensors
- Open Access
- 2 July 2015
- Published by Indian Society for Education and Environment in Indian Journal of Science and Technology
- Vol. 8 (13)
Imaging of Solid Particle in Air using Optical Tomography based on CMOS Area Image Sensor
This paper presents the use of Complementary Metal Oxide Semiconductor (CMOS) area image sensor in an optical tomographic instrumentation system to image solid particle in air. The image reconstruction is based on two (2) projections with two CMOS area image sensors configured around a flow pipe. The CMOS area image sensor provides 1280x1024 pixels with a pixel size of 5.2 micron x 5.2 micron, which will provide a high resolution image. The advantage of applying a CMOS area image sensor as an optical sensor is it will minimize the time of getting multiple slices of reconstructed images. Thus, it can generate a 3D reconstructed image of the object easier and faster.
- 2 July 2015
- Published by Indian Society for Education and Environment in Indian Journal of Science and Technology
- Vol. 8 (13)
Open AccessImaging of Solid Particle in Air using Optical Tomography based on CMOS Area Image Sensor
This paper presents the use of Complementary Metal Oxide Semiconductor (CMOS) area image sensor in an optical tomographic instrumentation system to image solid particle in air. The image reconstruction is based on two (2) projections with two CMOS area image sensors configured around a flow pipe. The CMOS area image sensor provides 1280x1024 pixels with a pixel size of 5.2 micron x 5.2 micron, which will provide a high resolution image. The advantage of applying a CMOS area image sensor as an optical sensor is it will minimize the time of getting multiple slices of reconstructed images. Thus, it can generate a 3D reconstructed image of the object easier and faster.
- 18 March 2015
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 73 (3)
Hardware Development of Reflection Mode Ultrasonic Tomography System for Monitoring Flaws on Pipeline
Hardware Development of Reflection Mode Ultrasonic Tomography System for Monitoring Flaws on Pipeline
- 18 March 2015
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 73 (3)
Hardware Development of Reflection Mode Ultrasonic Tomography System for Monitoring Flaws on Pipeline
Hardware Development of Reflection Mode Ultrasonic Tomography System for Monitoring Flaws on Pipeline
- 8 September 2014
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 70 (3)
The Use of Reflection Mode Ultrasonic Transceiver Sensor in Pipeline Inspection Guage to Monitor Pipeline Internal Corrosion
Aging gas transmission pipelines are prone to internal corrosion due to the presence of carbon dioxide and hydrogen sulphide in the natural gas constituents. Commonly, the in-line inspection tool known as Pipeline Inspection Gauge (PIG) is applied to perform the corrosion inspection of the pipeline. This paper describes an ultrasonic instrumentation system for PIG to monitor internal corrosion of pipeline. The system consists of ultrasonic transceiver sensor, ultrasonic driving circuitry and data acquisition system. The hardware is equipped with a sensor carrier which is propelled along the test pipeline. The time of flight (TOF) of the ultrasonic wave is measured and was used to evaluate the internal corrosion of pipeline. An initial experimental instrument was set up to perform the distance measurement test at a frequency of 390 kHz, to simulate the changes of pipe wall thickness due to corrosion effect. Surface anomalies were created at different positions to simulate the changes of pipe wall thickness due to the corrosion effect. Variation in measured distances implied the existence of the surface anomalies. The results of the simulated surface anomalies showed that the percentage error was less than + 5%. The large value of average DC voltage gave indication of distance increment due to the depth of the surface anomalies. The developed ultrasonic instrumentation system is capable to monitor the internal corrosion of pipeline.
- 8 September 2014
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 70 (3)
The Use of Reflection Mode Ultrasonic Transceiver Sensor in Pipeline Inspection Guage to Monitor Pipeline Internal Corrosion
Aging gas transmission pipelines are prone to internal corrosion due to the presence of carbon dioxide and hydrogen sulphide in the natural gas constituents. Commonly, the in-line inspection tool known as Pipeline Inspection Gauge (PIG) is applied to perform the corrosion inspection of the pipeline. This paper describes an ultrasonic instrumentation system for PIG to monitor internal corrosion of pipeline. The system consists of ultrasonic transceiver sensor, ultrasonic driving circuitry and data acquisition system. The hardware is equipped with a sensor carrier which is propelled along the test pipeline. The time of flight (TOF) of the ultrasonic wave is measured and was used to evaluate the internal corrosion of pipeline. An initial experimental instrument was set up to perform the distance measurement test at a frequency of 390 kHz, to simulate the changes of pipe wall thickness due to corrosion effect. Surface anomalies were created at different positions to simulate the changes of pipe wall thickness due to the corrosion effect. Variation in measured distances implied the existence of the surface anomalies. The results of the simulated surface anomalies showed that the percentage error was less than + 5%. The large value of average DC voltage gave indication of distance increment due to the depth of the surface anomalies. The developed ultrasonic instrumentation system is capable to monitor the internal corrosion of pipeline.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Tomographic image reconstruction of monitoring flaws on gas pipeline based on reverse ultrasonic tomography
The capability of a technique to reconstruct a tomographic image of flaws existence on gas pipeline via reverse ultrasonic tomography is presented. The ultrasonic tomography system is developed to monitor flaws circumferentially on pipeline with contactless measurement of distance from sensors to the pipe. In oil and gas industry, the applications of ultrasonic tomography technique for flaw detection in pipeline are limited as this technology is still in its infancy. The design of the ultrasonic tomography system consists of ultrasonic sensing system, data acquisition and image reconstruction system. A reflection mode of ultrasonic sensor is used where the output ultrasonic signal reflected from the pipe to the sensor is acquired. The collected data will be used in image reconstruction system to visualize the image. In image reconstruction process, a linear back projection algorithm is used in order to reconstruct the image of the pipe profile with flaws existence. The back projection algorithm is derived by the mathematical relationship of forward and inverse problem. This reconstruction algorithm is implemented in Matlab software to analyze the performance of the technique for different projection and arrays. Through the simulated result, the reconstructed image based on four projections is found to be less smeared compared to the image based on two projections. The effect of aliasing on the image is also reduced as the number of projection is increased. Several images of pipe with flaws existence are reconstructed based on four projections, with 7 × 7 arrays of pixels and twenty-eight of ultrasonic sensors.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Tomographic image reconstruction of monitoring flaws on gas pipeline based on reverse ultrasonic tomography
The capability of a technique to reconstruct a tomographic image of flaws existence on gas pipeline via reverse ultrasonic tomography is presented. The ultrasonic tomography system is developed to monitor flaws circumferentially on pipeline with contactless measurement of distance from sensors to the pipe. In oil and gas industry, the applications of ultrasonic tomography technique for flaw detection in pipeline are limited as this technology is still in its infancy. The design of the ultrasonic tomography system consists of ultrasonic sensing system, data acquisition and image reconstruction system. A reflection mode of ultrasonic sensor is used where the output ultrasonic signal reflected from the pipe to the sensor is acquired. The collected data will be used in image reconstruction system to visualize the image. In image reconstruction process, a linear back projection algorithm is used in order to reconstruct the image of the pipe profile with flaws existence. The back projection algorithm is derived by the mathematical relationship of forward and inverse problem. This reconstruction algorithm is implemented in Matlab software to analyze the performance of the technique for different projection and arrays. Through the simulated result, the reconstructed image based on four projections is found to be less smeared compared to the image based on two projections. The effect of aliasing on the image is also reduced as the number of projection is increased. Several images of pipe with flaws existence are reconstructed based on four projections, with 7 × 7 arrays of pixels and twenty-eight of ultrasonic sensors.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 311-317
Electronic Multilingual Arabic Dictionary Based on Root -Word with Self-Assessment
This paper describes an electronic multilingual Arabic dictionary that enables searches based on root words or radical alphabets with added self-assessment to enhance learning of the language for non-native speakers. Without the presence of a teacher as available in a school setting, one can develop a language with self-tutoring by using a well designed dictionary with many entries. This is now implemented effectively in an electronic dictionary. Since the majority of Arabic words are trilateral being derived from three radical alphabets, it lends itself naturally to a rootword based organization. However, it is transparent to students who can search full words in any derivative forms. Once a word is found, all necessary information on its meanings, usage, examples, etymology, audio, and other aids can be added in the future. The developed dictionary also includes quizzes which are designed to facilitate students in learning Arabic in effect creating a vocabulary builder.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 311-317
Electronic Multilingual Arabic Dictionary Based on Root -Word with Self-Assessment
This paper describes an electronic multilingual Arabic dictionary that enables searches based on root words or radical alphabets with added self-assessment to enhance learning of the language for non-native speakers. Without the presence of a teacher as available in a school setting, one can develop a language with self-tutoring by using a well designed dictionary with many entries. This is now implemented effectively in an electronic dictionary. Since the majority of Arabic words are trilateral being derived from three radical alphabets, it lends itself naturally to a rootword based organization. However, it is transparent to students who can search full words in any derivative forms. Once a word is found, all necessary information on its meanings, usage, examples, etymology, audio, and other aids can be added in the future. The developed dictionary also includes quizzes which are designed to facilitate students in learning Arabic in effect creating a vocabulary builder.
- 27 February 2014
- Published by Springer Nature
- p. 205-211
Driving Circuitry of Complementary Metal Oxide Semiconductor (CMOS) Area Image Sensor for Optical Tomography Instrumentation System
- 27 February 2014
- Published by Springer Nature
- p. 205-211
Driving Circuitry of Complementary Metal Oxide Semiconductor (CMOS) Area Image Sensor for Optical Tomography Instrumentation System
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 628-632
Hardware Implementation of Math Module Based on CORDIC Algorithm Using FPGA
This paper discusses the implementation of math hardware module based on CORDIC algorithm to solve trigonometry, hyperbolic and exponential function on FPGA. CORDIC is one of the hardware efficient and iteration based algorithms that is used to implement various transcendental functions such as trigonometry, hyperbolic, exponential and so forth. In addition, by using this algorithm, the hardware requirement and cost are less as only shift registers, adders and ROM are required. Thus, the design is implemented on FPGA since it provides a versatile and inexpensive way for implementation. The design is then further interfaced with 4x4 matrix keypad and 16x2 character LCD to build a simple math hardware module for real time application. The coding of algorithm was written in Verilog HDL and the verification is done firstly by using simulation results of the ModelSim and then using the implementation on Alter a DE1 board with the design interfaced with keypad and LCD to display the results.
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 628-632
Hardware Implementation of Math Module Based on CORDIC Algorithm Using FPGA
This paper discusses the implementation of math hardware module based on CORDIC algorithm to solve trigonometry, hyperbolic and exponential function on FPGA. CORDIC is one of the hardware efficient and iteration based algorithms that is used to implement various transcendental functions such as trigonometry, hyperbolic, exponential and so forth. In addition, by using this algorithm, the hardware requirement and cost are less as only shift registers, adders and ROM are required. Thus, the design is implemented on FPGA since it provides a versatile and inexpensive way for implementation. The design is then further interfaced with 4x4 matrix keypad and 16x2 character LCD to build a simple math hardware module for real time application. The coding of algorithm was written in Verilog HDL and the verification is done firstly by using simulation results of the ModelSim and then using the implementation on Alter a DE1 board with the design interfaced with keypad and LCD to display the results.