Philippe Martin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Philippe Martin has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
Pierre Rouchon
Centre Automatique et Systèmes, MINES ParisTech, PSL Research University, Paris, France
22 shared publications- Pierre Rouchon
Laboratoire de Physique de l'Ecole Normale Supérieure
15 shared publications P. Rouchon
Centre Automatique et Systèmes, MINES ParisTech, PSL Research University, France
13 shared publicationsLionel Rosier
Centre Automatique et Systèmes, MINES ParisTech, PSL Research University, 75006 Paris, France
9 shared publicationsAl Kassem Jebai
Schneider Toshiba Inverter Europe, 27120 Pacy-sur-Eure, France
8 shared publicationsM. Fliess
Centre de Math. et de Leurs Appl., Ecole Normale Superieure de Cachan, France
7 shared publications
Latest Publications
- Open Access
- 6 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 5445-5448
Error Estimates in Second-Order Continuous-Time Sigma-Delta Modulators
Continuous-time Sigma-Delta (CT-ΔΣ) modulators are oversampling Analog-to-Digital converters that may provide higher sampling rates and lower power consumption than their discrete counterpart. Whereas approximation errors are established for high-order discrete time ΔΣ modulators, theoretical analysis of the error between the filtered output and the input remain scarce. This paper presents a general framework to study this error: under regularity assumptions on the input and the filtering kernel, we prove for a second-order CT-ΔΣ that the error estimate may be in o(1/N)2, where N is the oversampling ratio. The whole theory is validated by numerical experiments.
- 6 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 5445-5448
Open AccessError Estimates in Second-Order Continuous-Time Sigma-Delta Modulators
Continuous-time Sigma-Delta (CT-ΔΣ) modulators are oversampling Analog-to-Digital converters that may provide higher sampling rates and lower power consumption than their discrete counterpart. Whereas approximation errors are established for high-order discrete time ΔΣ modulators, theoretical analysis of the error between the filtered output and the input remain scarce. This paper presents a general framework to study this error: under regularity assumptions on the input and the filtering kernel, we prove for a second-order CT-ΔΣ that the error estimate may be in o(1/N)2, where N is the oversampling ratio. The whole theory is validated by numerical experiments.
- 17 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Towards an industrially implementable PWM-injection scheme
We show how the rotor position of a PWM-fed PMSM can be recovered, even at low velocity or standstill, from the measured currents. The method is based on the excitation created by the PWM, without the need for an external probing signal. One originality of the approach is that we directly process the bitstream output by a Sigma-Delta modulator, hence do not require special derivative current sensors nor fast multibit ADCs, thereby opening the way for an effective implementation in an industrial drive.
- 17 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Towards an industrially implementable PWM-injection scheme
We show how the rotor position of a PWM-fed PMSM can be recovered, even at low velocity or standstill, from the measured currents. The method is based on the excitation created by the PWM, without the need for an external probing signal. One originality of the approach is that we directly process the bitstream output by a Sigma-Delta modulator, hence do not require special derivative current sensors nor fast multibit ADCs, thereby opening the way for an effective implementation in an industrial drive.
- Open Access
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2692-2698
Adding virtual measurements by PWM-induced signal injection
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2692-2698
Open AccessAdding virtual measurements by PWM-induced signal injection
- Open Access
Controllability of the 1D Schrödinger equation using flatness
We derive in a direct way the exact controllability of the 1D free Schr\"odinger equation with Dirichlet boundary control. We use the so-called flatness approach, which consists in parametrizing the solution and the control by the derivatives of a "flat output". This provides an explicit and very regular control achieving the exact controllability in the energy space.
Open AccessControllability of the 1D Schrödinger equation using flatness
We derive in a direct way the exact controllability of the 1D free Schr\"odinger equation with Dirichlet boundary control. We use the so-called flatness approach, which consists in parametrizing the solution and the control by the derivatives of a "flat output". This provides an explicit and very regular control achieving the exact controllability in the energy space.
- Open Access
Exact controllability of a linear Korteweg-de Vries equation by the flatness approach
We consider a linear Korteweg-de Vries equation on a bounded domain with a left Dirichlet boundary control.The controllability to the trajectories of such a system was proved in the last decade by using Carleman estimates.Here, we go a step further by establishing the exact controllability in a space of analytic functions with the aid of the flatness approach.
Open AccessExact controllability of a linear Korteweg-de Vries equation by the flatness approach
We consider a linear Korteweg-de Vries equation on a bounded domain with a left Dirichlet boundary control.The controllability to the trajectories of such a system was proved in the last decade by using Carleman estimates.Here, we go a step further by establishing the exact controllability in a space of analytic functions with the aid of the flatness approach.
- 26 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automatic Control
- Vol. 63 (10) , 3551-3557
Delay-Robust Control Design for Two Heterodirectional Linear Coupled Hyperbolic PDEs
We detail in this article the importance of a change of strategy for the delay-robust control of systems composed of two linear first order hyperbolic equations. One must go back to the classical trade-off between convergence rate and delay-robustness. More precisely, we prove that, for systems with strong reflections, canceling the reflection at the actuated boundary will yield zero delay-robustness. Indeed, for such systems, using a backstepping-controller, the corresponding target system should preserve a small amount of this reflection to ensure robustness to a small delay in the loop. This implies, in some cases, giving up finite time convergence.
- 26 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automatic Control
- Vol. 63 (10) , 3551-3557
Delay-Robust Control Design for Two Heterodirectional Linear Coupled Hyperbolic PDEs
We detail in this article the importance of a change of strategy for the delay-robust control of systems composed of two linear first order hyperbolic equations. One must go back to the classical trade-off between convergence rate and delay-robustness. More precisely, we prove that, for systems with strong reflections, canceling the reflection at the actuated boundary will yield zero delay-robustness. Indeed, for such systems, using a backstepping-controller, the corresponding target system should preserve a small amount of this reflection to ensure robustness to a small delay in the loop. This implies, in some cases, giving up finite time convergence.
- 24 October 2017
- Published by Springer Nature
- p. 345-351
Global Exponential Attitude and Gyro Bias Estimation from Vector Measurements
- 24 October 2017
- Published by Springer Nature
- p. 345-351
Global Exponential Attitude and Gyro Bias Estimation from Vector Measurements
- Open Access
Obtaining the Current-Flux Relations of the Saturated PMSM by Signal Injection
This paper proposes a method based on signal injection to obtain the saturated current-flux relations of a PMSM from locked-rotor experiments. With respect to the classical method based on time integration, it has the main advantage of being completely independent of the stator resistance; moreover, it is less sensitive to voltage biases due to the power inverter, as the injected signal may be fairly large.
Open AccessObtaining the Current-Flux Relations of the Saturated PMSM by Signal Injection
This paper proposes a method based on signal injection to obtain the saturated current-flux relations of a PMSM from locked-rotor experiments. With respect to the classical method based on time integration, it has the main advantage of being completely independent of the stator resistance; moreover, it is less sensitive to voltage biases due to the power inverter, as the injected signal may be fairly large.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Modeling and identification of synchronous reluctance motors
The goal of this paper is to propose a model of the (cross-)saturated SynRM suitable for sensorless control purposes, together with an identification procedure suitable for reasonably easy use in the field: the model contains about ten parameters, which are identified from only the drive current measurements, in experiments where the rotor is locked in a known position. The experimental procedure relies on signal injection to produce data that can be used for parameter identification.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Modeling and identification of synchronous reluctance motors
The goal of this paper is to propose a model of the (cross-)saturated SynRM suitable for sensorless control purposes, together with an identification procedure suitable for reasonably easy use in the field: the model contains about ten parameters, which are identified from only the drive current measurements, in experiments where the rotor is locked in a known position. The experimental procedure relies on signal injection to produce data that can be used for parameter identification.