Junbo Deng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Junbo Deng has a total of 179 co-authors. Here are the top co-authors by number of shared publications:
- Guanjun Zhang
Xi’an Jiaotong University
26 shared publications - Jianyi Xue
Hefei University of Technology
8 shared publications - Wen-Dong Li
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
8 shared publications - Aixuan Zhao
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University 1 , Xi’an, Shaanxi 710049, P.R. China
7 shared publications - Junhong Chen
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou, Fujian, China
7 shared publications Shurong Li
7 shared publications
Latest Publications
- Open Access
Back Feeding Energization Transients in a 500 kV Gas-Insulated Switchgear: Field Tests and Electromagnetic Transient Analysis
The special back feeding energization process involves several stages, including tie-transformer energization, GIS-busbar energization, and no-load line energization. These operations can generate transient overvoltages and impose considerable stress on equipment insulation. To investigate the associated transient characteristics, field tests were conducted at a 500 kV GIS substation. Transient signals were recorded during tie-transformer energization and GIS-busbar switching, and the responses at different stages were analyzed. An electromagnetic transient model was subsequently developed in PSCAD/EMTDC and validated against the field measurements. The validated model was then used to investigate the key factors affecting no-load line energization through a GIS outgoing bay. The results show that tie-transformer energization is dominated by nonlinear core excitation. As the system operating state is progressively established, the transient responses during GIS-busbar and transmission line energization are governed mainly by network parameters and switching conditions. During no-load line energization, the closing phase angle and closing resistor condition are the dominant factors affecting switching overvoltage. Degradation of the closing resistor weakens transient suppression and increases the insulation stress on connected equipment. These findings provide a technical basis for evaluating energization transients and optimizing operating conditions during the commissioning of 500 kV GIS installations.
Open AccessBack Feeding Energization Transients in a 500 kV Gas-Insulated Switchgear: Field Tests and Electromagnetic Transient Analysis
The special back feeding energization process involves several stages, including tie-transformer energization, GIS-busbar energization, and no-load line energization. These operations can generate transient overvoltages and impose considerable stress on equipment insulation. To investigate the associated transient characteristics, field tests were conducted at a 500 kV GIS substation. Transient signals were recorded during tie-transformer energization and GIS-busbar switching, and the responses at different stages were analyzed. An electromagnetic transient model was subsequently developed in PSCAD/EMTDC and validated against the field measurements. The validated model was then used to investigate the key factors affecting no-load line energization through a GIS outgoing bay. The results show that tie-transformer energization is dominated by nonlinear core excitation. As the system operating state is progressively established, the transient responses during GIS-busbar and transmission line energization are governed mainly by network parameters and switching conditions. During no-load line energization, the closing phase angle and closing resistor condition are the dominant factors affecting switching overvoltage. Degradation of the closing resistor weakens transient suppression and increases the insulation stress on connected equipment. These findings provide a technical basis for evaluating energization transients and optimizing operating conditions during the commissioning of 500 kV GIS installations.
- Open Access
- 1 February 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (2)
A computational study on the charge-trapping characteristics of nano-silica-doped polydimethylsiloxane composites
Widely used as an insulating material in power cables, polydimethylsiloxane (PDMS) requires improved dielectric properties. Doping with nanoparticles is recognized as a feasible modification method, in which changes in charge-trapping characteristics are considered to be the key factor. However, the physical mechanism by which nanoparticles affect the charge-trapping characteristics of polymers is not yet fully understood. Using molecular dynamics, quantum chemistry, and first-principles methods, possible ways in which silica nanoparticles could affect the charge-trapping characteristics of PDMS are explored here. The results demonstrate that structural disorder in undoped PDMS results in electron traps of <0.4 eV and hole traps of <0.65 eV. After doping with silica nanoparticles, the changes in PDMS molecular structures are much smaller than those caused by the intrinsic structural disorder of PDMS. Therefore, the indirect effect by which silica nanoparticles change the charge-trapping characteristics of the polymer by affecting the structures of adjacent PDMS molecules is relatively weak. The results of first-principles calculations show that a 0.8 eV conduction band offset and a 1.4 eV valence band offset exist at the silica/PDMS interface region. These band offsets act as charge traps to block the charge transport process and change the charge-trapping characteristics of PDMS composites.
- 1 February 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (2)
Open AccessA computational study on the charge-trapping characteristics of nano-silica-doped polydimethylsiloxane composites
Widely used as an insulating material in power cables, polydimethylsiloxane (PDMS) requires improved dielectric properties. Doping with nanoparticles is recognized as a feasible modification method, in which changes in charge-trapping characteristics are considered to be the key factor. However, the physical mechanism by which nanoparticles affect the charge-trapping characteristics of polymers is not yet fully understood. Using molecular dynamics, quantum chemistry, and first-principles methods, possible ways in which silica nanoparticles could affect the charge-trapping characteristics of PDMS are explored here. The results demonstrate that structural disorder in undoped PDMS results in electron traps of <0.4 eV and hole traps of <0.65 eV. After doping with silica nanoparticles, the changes in PDMS molecular structures are much smaller than those caused by the intrinsic structural disorder of PDMS. Therefore, the indirect effect by which silica nanoparticles change the charge-trapping characteristics of the polymer by affecting the structures of adjacent PDMS molecules is relatively weak. The results of first-principles calculations show that a 0.8 eV conduction band offset and a 1.4 eV valence band offset exist at the silica/PDMS interface region. These band offsets act as charge traps to block the charge transport process and change the charge-trapping characteristics of PDMS composites.
- 31 December 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 254
Analysis of VFTO triggered by disconnector switching in 750 kV air-insulated substation
- 31 December 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 254
Analysis of VFTO triggered by disconnector switching in 750 kV air-insulated substation
- 4 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Separation of Multi-Source Partial Discharges Based on Continuous Wavelet Transform and Uniform Manifold Approximation and Projection
Partial discharge (PD) detection is one of the most effective methods for assessing the insulation condition of electrical equipment. In practical applications, multiple defects may coexist within the insulation, resulting in multi-source PDs, which complicates the localization and identification of these defects. Therefore, the separation of multi-source PD signals is essential. In this paper, a novel method combining continuous wavelet transform (CWT) and uniform manifold approximation and projection (UMAP) is proposed to separate PD signals from different defect types. Firstly, CWT is employed to convert the time-domain PD waveform into a time-frequency diagram, from which amplitude information is extracted as PD features. Subsequently, the UMAP algorithm is employed to reduce the dimensionality of the high-dimensional feature to two dimensions. Finally, these two parameters are plotted in a two-dimensional plane, forming a separation map. Experimental results involving single-source PDs from four types of defects and multi-source PDs from two types of defects validate the effectiveness of the proposed method. Compared to conventional approaches, the proposed method offers superior separation performance, providing significant practical value, particularly for offline PD detection.
- 4 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Separation of Multi-Source Partial Discharges Based on Continuous Wavelet Transform and Uniform Manifold Approximation and Projection
Partial discharge (PD) detection is one of the most effective methods for assessing the insulation condition of electrical equipment. In practical applications, multiple defects may coexist within the insulation, resulting in multi-source PDs, which complicates the localization and identification of these defects. Therefore, the separation of multi-source PD signals is essential. In this paper, a novel method combining continuous wavelet transform (CWT) and uniform manifold approximation and projection (UMAP) is proposed to separate PD signals from different defect types. Firstly, CWT is employed to convert the time-domain PD waveform into a time-frequency diagram, from which amplitude information is extracted as PD features. Subsequently, the UMAP algorithm is employed to reduce the dimensionality of the high-dimensional feature to two dimensions. Finally, these two parameters are plotted in a two-dimensional plane, forming a separation map. Experimental results involving single-source PDs from four types of defects and multi-source PDs from two types of defects validate the effectiveness of the proposed method. Compared to conventional approaches, the proposed method offers superior separation performance, providing significant practical value, particularly for offline PD detection.
- 23 October 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 252
A novel reflection coefficient estimation method to improve cable defect diagnostic accuracy based on beat signal
- 23 October 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 252
A novel reflection coefficient estimation method to improve cable defect diagnostic accuracy based on beat signal
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Subsynchronous Stability Analysis of DFIG-Based Wind Farm Considering the Error of Current Measuring System
Although many scholars have made a comprehensive explanation of the mechanism of subsynchronous oscillation (SSO), there still exist unexplained events in actual wind farms. Therefore, from the perspective of input signal of current controller, this article proposes an equivalent model of doubly fed induction generators (DFIGs) connected to series-compensated transmission line that considers the influence of the current measuring system. The mathematical model of the current measuring system is established by a$\Gamma $ -type circuit and a$\pi $ -type circuit equivalent to the electromagnetic current transformer and the power cable, respectively. Then, the oscillation mechanism of DFIGs in critical stability is explained from the perspective of Nyquist criterion. Meanwhile, the impact regulations of the proposed current measuring system on the SSO occurrence in wind farm are verified by PSCAD and compared with field tests. Finally, the transfer characteristics of the proposed model are explored within a wide frequency range, illustrating the necessity to consider the current measuring system when analyzing the stability of SSO.- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Subsynchronous Stability Analysis of DFIG-Based Wind Farm Considering the Error of Current Measuring System
Although many scholars have made a comprehensive explanation of the mechanism of subsynchronous oscillation (SSO), there still exist unexplained events in actual wind farms. Therefore, from the perspective of input signal of current controller, this article proposes an equivalent model of doubly fed induction generators (DFIGs) connected to series-compensated transmission line that considers the influence of the current measuring system. The mathematical model of the current measuring system is established by a$\Gamma $ -type circuit and a$\pi $ -type circuit equivalent to the electromagnetic current transformer and the power cable, respectively. Then, the oscillation mechanism of DFIGs in critical stability is explained from the perspective of Nyquist criterion. Meanwhile, the impact regulations of the proposed current measuring system on the SSO occurrence in wind farm are verified by PSCAD and compared with field tests. Finally, the transfer characteristics of the proposed model are explored within a wide frequency range, illustrating the necessity to consider the current measuring system when analyzing the stability of SSO.- 25 July 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 249
Transient electric field analysis of 750 kV GIS breaker under lightning impulse delivery test
- 25 July 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 249
Transient electric field analysis of 750 kV GIS breaker under lightning impulse delivery test