SPShashwat Pathak

Shashwat Pathak

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shashwat Pathak has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Low-latency and High-Reliability FBMC Modulation scheme using Optimized Filter design for enabling NextG Real-time Smart Healthcare Applications

    by Abhinav Adarsh, Shashwat Pathak, Digvijay Singh Chauhan, Basant Kumar

    This paper presents a prototype filter design using the orthant optimization technique to assist a filter bank multicarrier (FBMC) modulation scheme of a NextG smart e-healthcare network framework. Low latency and very high reliability are one of the main requirements of a real-time e-healthcare system. In recent times, FBMC modulation has gotten more attention due to its spectral efficiency. The characteristics of a filter bank are determined by t’s, prototype filter. A prototype filter cannot be designed to achieve an arbitrary time localization (for low latency) and frequency localization (spectral efficiency), as time and frequency spreading are conflicting goals. Hence, an optimum design needed to be achieved. In this paper, a constraint for perfect or nearly perfect reconstruction is formulated for prototype filter design and an orthant-based enriched sparse ℓ1-optimization method is applied to achieve the optimum performance in terms of higher availability of subcarrier spacing for the given requirement of signal-to-interference ratio. Larger subcarrier spacing ensures lower latency and better performance in real-time applications. The proposed FBMC system, based on an optimum design of the prototype filter, also supports a higher data rate as compared to traditional FBMC and OFDM systems, which is another requirement of real-time communication. In this paper, the solution for the different technical issues of physical layer design is provided. The presented modulation scheme through the proposed prototype filter-based FBMC can suppress the side lobe energy of the constituted filters up to large extent without compromising the recovery of the signal at the receiver end. The proposed system provides very high spectral efficiency; it can sacrifice large guard band frequencies to increase the subcarrier spacing to provide low-latency communication to support the real-time e-healthcare network.


  • Development of portable and robust cataract detection and grading system by analyzing multiple texture features for Tele-Ophthalmology

    by Shashwat Pathak, Rahul Raj, Kartik Singh, Pawan Kumar Verma, Basant Kumar

    This paper presents a low cost, robust, portable and automated cataract detection system which can detect the presence of cataract from the colored digital eye images and grade their severity. Ophthalmologists detect cataract through visual screening using ophthalmoscope and slit lamps. Conventionally a patient has to visit an ophthalmologist for eye screening and treatment follows the course. Developing countries lack the proper health infrastructure and face huge scarcity of trained medical professionals as well as technicians. The condition is not very satisfactory with the rural and remote areas of developed nations. To bridge this barrier between the patient and the availability of resources, current work focuses on the development of portable low-cost, robust cataract screening and grading system. Similar works use fundus and retinal images which use costly imaging modules and image based detection algorithms which use much complex neural network models. Current work derives its benefit from the advancements in digital image processing techniques. A set of preprocessing has been done on the colored eye image and later texture information in form of mean intensity, uniformity, standard deviation and randomness has been calculated and mapped with the diagnostic opinion of doctor for cataract screening of over 200 patients. For different grades of cataract severity edge pixel count was calculated as per doctor’s opinion and later these data are used for calculating the thresholds using hybrid k-means algorithm, for giving a decision on the presence of cataract and grade its severity. Low value of uniformity and high value of other texture parameters confirm the presence of cataract as clouding in eye lens causes the uniformity function to take lower value due to presence of coarse texture. Higher the edge pixel count value, this confirms the presence of starting of cataract as solidified regions in lens are nonuniform. Lower value corresponds to fully solidified region or matured cataract. Proposed algorithm was initially developed on MATLAB, and tested on over 300 patients in an eye camp. The system has shown more than 98% accuracy in detection and grading of cataract. Later a cloud based system was developed with 3D printed image acquisition module to manifest an automated, portable and efficient cataract detection system for Tele-Ophthalmology. The proposed system uses a very simple and efficient technique by mapping the diagnostic opinion of the doctor as well, giving very promising results which suggest its potential use in teleophthalmology applications to reduce the cost of delivering eye care services and increasing its reach effectively. Developed system is simple in design and easy to operate and suitable for mass screening of cataracts. Due to non-invasive and non-mydriatic and mountable nature of device, in person screening is not required. Hence, social distancing norms are easy to follow and device is very useful in COVID-19 like situation.


  • Basics of Python Programming

    by Vijay Kumar Sharma, Vimal Kumar, Swati Sharma, Shashwat Pathak

    To start with writing any program in Python, a user must be aware of variables, declarations, data types, libraries, functions, and their proper representation. To recognize the variables, identifiers are used, and Python has an inbuilt function to determine the class of input and output as well. Conversion of data from one base to another base and transforming the data type of a value into another data type are some common operations that are presented in this chapter. Data representation and their combination in the form of fixed and variable sets and in various other forms is explained. The chapter concludes with information regarding the escape characters, which are used in relation to the special meaning and math module that supports various functions for performing various mathematical operations. Readers will be able to declare variables, choose data type, and perform base conversions and mathematical and logical operations, after reading this chapter.


  • Strings

    by Vijay Kumar Sharma, Vimal Kumar, Swati Sharma, Shashwat Pathak

    This chapter presents a vital element called strings. In many complex conditions, it is much easier to work with Python because the string structure is well defined. To help the reader understand its usage, the method for creating a string is presented. After creation, different operations such as changing the size of the string, appending with some particular value, and different other manipulations have been presented. Logical operations, discussed in the previous chapter have been presented, to be implemented on strings and some intrinsic string specific operations have been discussed that determine the membership of a string. A reader will be able to understand the full in-depth analysis of defining and performing logical operations, and defining every part of a string for useful analysis.


  • Wireless Teleophthalmology: A Novel, Low-Cost, Flexible Network Architecture and Its Performance Evaluation for Remote Eye Care Solutions

    by Shashwat Pathak, Basant Kumar

    Introduction: This article proposes a novel, cost-effective, flexible, and easy-to-deploy wireless teleophthalmology network architecture and performance evaluation for its potential use in remote areas. This study has used practical telecommunication standards, which is widely deployed throughout India. Methods: In the proposed scenario, patient's eye images are obtained using a specified imaging modality, and then sent to a server at the primary eye care centre (PECC) using ZigBee a short-range wireless network. It is linked to the main server at the base eye hospital (BEH) through a GSM/UMTS (3G)/WiMAX (Worldwide Interoperability for Microwave Access) network. After diagnostic evaluation of the eye image using various automated diagnostic software, data are sent to a physician in an urban center for further validation, which is connected through GSM/UMTS (3G)/WiMAX network. Performance evaluation of these wireless networks is carried out for their use in teleophthalmology application based on network parameters, namely throughput, average end-to-end delay, and average jitter. It is found that end-to-end delay is the most critical network parameter affecting overall quality of service (QoS) of the proposed teleophthalmology network. Results and Conclusions: The results demonstrate that WiMAX is the most suitable network among the considered networks for connecting PECC nodes with BEH main server, and further connecting main server with a doctor on the move. It is also deduced that for a given set of QoS parameters, WiMAX supports a load capacity of 22,000 packets at center nodes and the main server and it performs well even when the mobility speed of doctor exceeds 200 KPH.


  • A novel cataract detection algorithm using clinical data mapping

    by Shashwat Pathak, Shubham Gupta, Basant Kumar

    This paper proposes and evaluates an algorithm to automatically detect the cataracts from color images. Currently, methods available for cataract detection are based on the use of either fundus camera or DSLR camera; both are very expensive. The main motive behind this work is to develop an inexpensive, robust and convenient algorithm which in conjugation with suitable devices will be able to diagnose the presence of cataract from the true color images of eye. An algorithm is proposed for Cataract Screening based on texture features: uniformity, intensity and standard deviation. These features are first computed and mapped with diagnostic opinion by the eye expert to define the basic threshold of screening system later tested on real subjects in eye clinic.


  • Open Access

    A Robust Automated Cataract Detection Algorithm Using Diagnostic Opinion Based Parameter Thresholding for Telemedicine Application

    by Shashwat Pathak, Basant Kumar

    This paper proposes and evaluates an algorithm to automatically detect the cataracts from color images in adult human subjects. Currently, methods available for cataract detection are based on the use of either fundus camera or Digital Single-Lens Reflex (DSLR) camera; both are very expensive. The main motive behind this work is to develop an inexpensive, robust and convenient algorithm which in conjugation with suitable devices will be able to diagnose the presence of cataract from the true color images of an eye. An algorithm is proposed for cataract screening based on texture features: uniformity, intensity and standard deviation. These features are first computed and mapped with diagnostic opinion by the eye expert to define the basic threshold of screening system and later tested on real subjects in an eye clinic. Finally, a tele-ophthamology model using our proposed system has been suggested, which confirms the telemedicine application of the proposed system.