Peter Blümler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Peter Blümler has a total of 124 co-authors. Here are the top co-authors by number of shared publications:
- Dmitry Budker
Helmholtz Institute Mainz
3 shared publications Friederike Schmid
Institute of Physics, University of Mainz, Mainz, Germany
3 shared publicationsOlga Baun
Institute of Physics, Johannes Gutenberg-University Mainz, Mainz, 55128, Germany
3 shared publicationsWerner Heil
Institute of Physics , University of Mainz , 55122 Mainz , Germany
3 shared publications- Werner Heil
Institut für Physik Johannes Gutenberg-Universität 55128 Mainz Germany
3 shared publications - A. Glen Birdwell
DEVCOM Army Research Laboratory
2 shared publications
Latest Publications
- Open Access
- 20 October 2026
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 57 (11-12) , 68
Correction: Bernhard Blümich: On the Occasion of His 70th Birthday
- 20 October 2026
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 57 (11-12) , 68
Open AccessCorrection: Bernhard Blümich: On the Occasion of His 70th Birthday
- Open Access
- 11 June 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (6)
Toward a temperature-insensitive composite diamond clock
Frequency references based on solid-state spins promise simplicity, compactness, robustness, multifunctionality, ease of integration, and high densities of emitters. Nitrogen-vacancy (NV) centers in diamond are a natural candidate, but the electronic zero-field splitting ( D ≈ 2.87 GHz ) exhibits a large fractional temperature dependence (around 25 ppb / mK ), which has precluded its use as a stable clock transition. Here we show that this limitation can be overcome by forming a composite frequency reference that combines measurements of the electronic splitting D with the nuclear quadrupole splitting ( Q ≈ 4.94 MHz ) of the 14 N nuclear spin intrinsic to the NV center. We further benchmark this composite approach against alternative strategies for mitigating temperature sensitivity, including cryogenic operation, temperature compensation, and active stabilization. By implementing a specially designed pulse sequence with an eight-phase control scheme that suppresses pulse imperfections, we interleave measurements of D and Q in a high-density NV ensemble and demonstrate a temperature-compensated composite frequency reference. The stability of this composite diamond clock is characterized over a 10-day period at room temperature through a comparison to a Rb vapor-cell clock, yielding a fractional instability below 5 × 10 − 9 for an averaging time of τ = 200 s and below 1 × 10 − 8 at τ = 2 × 10 5 s , corresponding to measured improvements by a factor of approximately 4 and approximately 200 , respectively, over a clock based purely on the single frequency D for the same periods. By characterizing the residual sensitivity to magnetic fields, optical power, and radio-frequency drive amplitudes, we find that temperature is no longer the dominant source of instability. These results establish complementary electron- and nuclear-spin transitions in diamond as a viable route to thermally robust frequency metrology, providing a pathway toward compact, multifunctional solid-state clocks and quantum sensors.
- 11 June 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (6)
Open AccessToward a temperature-insensitive composite diamond clock
Frequency references based on solid-state spins promise simplicity, compactness, robustness, multifunctionality, ease of integration, and high densities of emitters. Nitrogen-vacancy (NV) centers in diamond are a natural candidate, but the electronic zero-field splitting ( D ≈ 2.87 GHz ) exhibits a large fractional temperature dependence (around 25 ppb / mK ), which has precluded its use as a stable clock transition. Here we show that this limitation can be overcome by forming a composite frequency reference that combines measurements of the electronic splitting D with the nuclear quadrupole splitting ( Q ≈ 4.94 MHz ) of the 14 N nuclear spin intrinsic to the NV center. We further benchmark this composite approach against alternative strategies for mitigating temperature sensitivity, including cryogenic operation, temperature compensation, and active stabilization. By implementing a specially designed pulse sequence with an eight-phase control scheme that suppresses pulse imperfections, we interleave measurements of D and Q in a high-density NV ensemble and demonstrate a temperature-compensated composite frequency reference. The stability of this composite diamond clock is characterized over a 10-day period at room temperature through a comparison to a Rb vapor-cell clock, yielding a fractional instability below 5 × 10 − 9 for an averaging time of τ = 200 s and below 1 × 10 − 8 at τ = 2 × 10 5 s , corresponding to measured improvements by a factor of approximately 4 and approximately 200 , respectively, over a clock based purely on the single frequency D for the same periods. By characterizing the residual sensitivity to magnetic fields, optical power, and radio-frequency drive amplitudes, we find that temperature is no longer the dominant source of instability. These results establish complementary electron- and nuclear-spin transitions in diamond as a viable route to thermally robust frequency metrology, providing a pathway toward compact, multifunctional solid-state clocks and quantum sensors.
- 4 May 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (5)
Discretized Halbach spheres: Icosahedral symmetry for optimal field homogeneity
- 4 May 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (5)
Discretized Halbach spheres: Icosahedral symmetry for optimal field homogeneity
- Open Access
- 7 April 2026
- Published by Springer Nature in Research Square
Microtubules are not passive load-bearing elements in axon growth
Axons are sensitive to piconewton (pN) forces, yet the cellular mechanisms underlying this mechanosensitivity remain poorly understood. Axonal mechanotransduction has traditionally been attributed to molecular clutches and mechanosensitive ion channels, whereas cytoskeletal microtubules (MTs) have been regarded primarily as passive load-bearing structures. Here, we propose MTs as active elements in signal mechanotransduction. Using nano-pulling to apply controlled, directional pN forces to hippocampal neurons, we show that force induces axon elongation only when applied along the intrinsic polarity of axonal MTs. Live imaging of the MT plus-end marker EB3 reveals modulation of MT dynamics and enhanced MT growth when force is applied along MT polarity, but not in the opposite direction. Strikingly, restricting force generation to the axolemma, thereby uncoupling mechanical inputs from the axonal cytoskeleton, abolishes force-induced axon elongation.
- 7 April 2026
- Published by Springer Nature in Research Square
Open AccessMicrotubules are not passive load-bearing elements in axon growth
Axons are sensitive to piconewton (pN) forces, yet the cellular mechanisms underlying this mechanosensitivity remain poorly understood. Axonal mechanotransduction has traditionally been attributed to molecular clutches and mechanosensitive ion channels, whereas cytoskeletal microtubules (MTs) have been regarded primarily as passive load-bearing structures. Here, we propose MTs as active elements in signal mechanotransduction. Using nano-pulling to apply controlled, directional pN forces to hippocampal neurons, we show that force induces axon elongation only when applied along the intrinsic polarity of axonal MTs. Live imaging of the MT plus-end marker EB3 reveals modulation of MT dynamics and enhanced MT growth when force is applied along MT polarity, but not in the opposite direction. Strikingly, restricting force generation to the axolemma, thereby uncoupling mechanical inputs from the axonal cytoskeleton, abolishes force-induced axon elongation.
- 11 June 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 23 (6)
Analytic approach to creating homogeneous fields with finite-size magnets
- 11 June 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 23 (6)
Analytic approach to creating homogeneous fields with finite-size magnets
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
Precision magnetometry at cryogenic temperatures with gaseous 3He NMR probes
We report on compact, gaseous 3He Nuclear Magnetic Resonance (NMR) probes for precision magnetometry of magnetic fields B > 0.1 T in the temperature range from ambient temperatures down to 4 K. The gas is polarized at thermal equilibrium under pressures up to 100 bars to provide a high nuclear spin density. To achieve sensor readout rates of O (Hz), paramagnetic substances and/or silica gel with high specific surface area were added to reduce the otherwise long T1 relaxation time of pure 3He gas and to reach thermal polarization equilibrium. Sensitivity limits, which cover the range from 10−11 < δB/B < 10−7, are accessible in a single-pulse NMR measurement and can be further improved through signal averaging in accumulated NMR scans.
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
Precision magnetometry at cryogenic temperatures with gaseous 3He NMR probes
We report on compact, gaseous 3He Nuclear Magnetic Resonance (NMR) probes for precision magnetometry of magnetic fields B > 0.1 T in the temperature range from ambient temperatures down to 4 K. The gas is polarized at thermal equilibrium under pressures up to 100 bars to provide a high nuclear spin density. To achieve sensor readout rates of O (Hz), paramagnetic substances and/or silica gel with high specific surface area were added to reduce the otherwise long T1 relaxation time of pure 3He gas and to reach thermal polarization equilibrium. Sensitivity limits, which cover the range from 10−11 < δB/B < 10−7, are accessible in a single-pulse NMR measurement and can be further improved through signal averaging in accumulated NMR scans.
- Top Cited PapersOpen Access
- 3 February 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-8
Optical widefield nuclear magnetic resonance microscopy
Microscopy enables detailed visualization and understanding of minute structures or processes. While cameras have significantly advanced optical, infrared, and electron microscopy, imaging nuclear magnetic resonance (NMR) signals on a camera has remained elusive. Here, we employ nitrogen-vacancy centers in diamond as a quantum sensor, which converts NMR signals into optical signals that are subsequently captured by a high-speed camera. Unlike traditional magnetic resonance imaging, our method records the NMR signal over a wide field of view in real space. We demonstrate that our optical widefield NMR microscopy can image NMR signals in microfluidic structures with a ~10 μm resolution across a ~235 × 150 μm2 area. Crucially, each camera pixel records an NMR spectrum providing multicomponent information about the signal’s amplitude, phase, local magnetic field strengths, and gradients. The fusion of optical microscopy and NMR techniques enables multifaceted imaging applications in the physical and life sciences.
- 3 February 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-8
Top Cited PapersOpen AccessOptical widefield nuclear magnetic resonance microscopy
Microscopy enables detailed visualization and understanding of minute structures or processes. While cameras have significantly advanced optical, infrared, and electron microscopy, imaging nuclear magnetic resonance (NMR) signals on a camera has remained elusive. Here, we employ nitrogen-vacancy centers in diamond as a quantum sensor, which converts NMR signals into optical signals that are subsequently captured by a high-speed camera. Unlike traditional magnetic resonance imaging, our method records the NMR signal over a wide field of view in real space. We demonstrate that our optical widefield NMR microscopy can image NMR signals in microfluidic structures with a ~10 μm resolution across a ~235 × 150 μm2 area. Crucially, each camera pixel records an NMR spectrum providing multicomponent information about the signal’s amplitude, phase, local magnetic field strengths, and gradients. The fusion of optical microscopy and NMR techniques enables multifaceted imaging applications in the physical and life sciences.
- Open Access
- 14 October 2024
- Published by IOP Publishing in Journal of Physics G: Nuclear and Particle Physics
- Vol. 51 (11) , 115103
τSPECT: a spin-flip loaded magnetic ultracold neutron trap for a determination of the neutron lifetime
The confinement of ultracold neutrons (UCNs) in three-dimensional magnetic field gradient or magneto-gravitational traps allows for a measurement of the free neutron lifetime τ n with superior control over loss channels related to UCNs interacting with material surfaces. The most precise measurement τ n has been achieved using a magneto-gravitational trap, in which UCN are prevented from escaping at the top of their trap by gravity. More compact horizontal confinement geometries with variable energy acceptance ranges can be obtained by using steep magnetic field gradients in all spatial directions, generated by combinations of either permanent or (variable) superconducting magnets. In this paper, we present the first successful implementation of a pulsed spin-flip based loading scheme to fill a three-dimensional magnetic trap with externally produced UCN. The measurements with the τSPECT experiment were performed at the pulsed UCN source of the research reactor TRIGA Mainz. The extracted neutron storage time constant of τ = 859(16) s is compatible with the most precise determinations of τ n . We report on detailed, but statistically limited, investigations of major systematic effects influencing the neutron storage time. The statistical limitations are mitigated by the relocation of the experiment to a stronger UCN source.
- 14 October 2024
- Published by IOP Publishing in Journal of Physics G: Nuclear and Particle Physics
- Vol. 51 (11) , 115103
Open AccessτSPECT: a spin-flip loaded magnetic ultracold neutron trap for a determination of the neutron lifetime
The confinement of ultracold neutrons (UCNs) in three-dimensional magnetic field gradient or magneto-gravitational traps allows for a measurement of the free neutron lifetime τ n with superior control over loss channels related to UCNs interacting with material surfaces. The most precise measurement τ n has been achieved using a magneto-gravitational trap, in which UCN are prevented from escaping at the top of their trap by gravity. More compact horizontal confinement geometries with variable energy acceptance ranges can be obtained by using steep magnetic field gradients in all spatial directions, generated by combinations of either permanent or (variable) superconducting magnets. In this paper, we present the first successful implementation of a pulsed spin-flip based loading scheme to fill a three-dimensional magnetic trap with externally produced UCN. The measurements with the τSPECT experiment were performed at the pulsed UCN source of the research reactor TRIGA Mainz. The extracted neutron storage time constant of τ = 859(16) s is compatible with the most precise determinations of τ n . We report on detailed, but statistically limited, investigations of major systematic effects influencing the neutron storage time. The statistical limitations are mitigated by the relocation of the experiment to a stronger UCN source.
- 22 April 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 21 (4) , 044039
Microwave-free wide-field magnetometry using nitrogen-vacancy centers
A wide-field magnetometer utilizing nitrogen-vacancy (N-) centers in diamond that does not require microwaves is demonstrated. It is designed for applications where microwaves need to be avoided, such as magnetic imaging of biological or conductive samples. The system exploits a magnetically sensitive feature of N- centers near the ground-state level anticrossing (GSLAC). An applied test field from a wire has been mapped over an imaging area of . Analysis of the ground-state level anticrossing (GSLAC) lineshape allows us to extract the vector information of the applied field. The device allows micrometer-scale magnetic imaging at a spatial resolution dominated by the thickness of the N- layer (here, ). For a pixel size of , the estimated photon-shot-noise-limited sensitivity is . Two modalities for visualizing the magnetic fields, static and temporal, are presented, along with a discussion of technical limitations and future extensions of the method.- 22 April 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 21 (4) , 044039
Microwave-free wide-field magnetometry using nitrogen-vacancy centers
A wide-field magnetometer utilizing nitrogen-vacancy (N-) centers in diamond that does not require microwaves is demonstrated. It is designed for applications where microwaves need to be avoided, such as magnetic imaging of biological or conductive samples. The system exploits a magnetically sensitive feature of N- centers near the ground-state level anticrossing (GSLAC). An applied test field from a wire has been mapped over an imaging area of . Analysis of the ground-state level anticrossing (GSLAC) lineshape allows us to extract the vector information of the applied field. The device allows micrometer-scale magnetic imaging at a spatial resolution dominated by the thickness of the N- layer (here, ). For a pixel size of , the estimated photon-shot-noise-limited sensitivity is . Two modalities for visualizing the magnetic fields, static and temporal, are presented, along with a discussion of technical limitations and future extensions of the method.- Open Access
- 3 April 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-13
A comprehensive approach to characterize navigation instruments for magnetic guidance in biological systems
Achieving non-invasive spatiotemporal control over cellular functions, tissue organization, and behavior is a desirable aim for advanced therapies. Magnetic fields, due to their negligible interaction with biological matter, are promising for in vitro and in vivo applications, even in deep tissues. Particularly, the remote manipulation of paramagnetic (including superparamagnetic and ferromagnetic, all with a positive magnetic susceptibility) entities through magnetic instruments has emerged as a promising approach across various biological contexts. However, variations in the properties and descriptions of these instruments have led to a lack of reproducibility and comparability among studies. This article addresses the need for standardizing the characterization of magnetic instruments, with a specific focus on their ability to control the movement of paramagnetic objects within organisms. While it is well known that the force exerted on magnetic particles depends on the spatial variation (gradient) of the magnetic field, the magnitude of the field is often overlooked in the literature. Therefore, we comprehensively analyze and discuss both actors and propose a novel descriptor, termed ‘effective gradient’, which combines both dependencies. To illustrate the importance of both factors, we characterize different magnet systems and relate them to experiments involving superparamagnetic nanoparticles. This standardization effort aims to enhance the reproducibility and comparability of studies utilizing magnetic instruments for biological applications.
- 3 April 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-13
Open AccessA comprehensive approach to characterize navigation instruments for magnetic guidance in biological systems
Achieving non-invasive spatiotemporal control over cellular functions, tissue organization, and behavior is a desirable aim for advanced therapies. Magnetic fields, due to their negligible interaction with biological matter, are promising for in vitro and in vivo applications, even in deep tissues. Particularly, the remote manipulation of paramagnetic (including superparamagnetic and ferromagnetic, all with a positive magnetic susceptibility) entities through magnetic instruments has emerged as a promising approach across various biological contexts. However, variations in the properties and descriptions of these instruments have led to a lack of reproducibility and comparability among studies. This article addresses the need for standardizing the characterization of magnetic instruments, with a specific focus on their ability to control the movement of paramagnetic objects within organisms. While it is well known that the force exerted on magnetic particles depends on the spatial variation (gradient) of the magnetic field, the magnitude of the field is often overlooked in the literature. Therefore, we comprehensively analyze and discuss both actors and propose a novel descriptor, termed ‘effective gradient’, which combines both dependencies. To illustrate the importance of both factors, we characterize different magnet systems and relate them to experiments involving superparamagnetic nanoparticles. This standardization effort aims to enhance the reproducibility and comparability of studies utilizing magnetic instruments for biological applications.